Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multichannel analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Satellite microwave and in situ observations of the Weddell Sea ice cover and its marginal ice zone

The radiative and physical characteristics of the Weddell Sea ice cover and its marginal ice zone are analyzed using multichannel satellite passive microwave data and ship and helicopter observations obtained during the 1983 Antarctic Marine Ecosystem Research. Winter and spring brightness temperatures are examined; spatial variability in the brightness temperatures of consolidated ice in winter and spring cyclic increases and decrease in brightness temperatures of consolidated ice with an amplitude of 50 K at 37 GHz and 20 K at 18 GHz are observed. The roles of variations in air temperature and surface characteristics in the variability of spring brightness temperatures are investigated. Ice concentrations are derived using the frequency and polarization techniques, and the data are compared with the helicopter and ship observations. Temporal changes in the ice margin structure and the mass balance of fresh water and of biological features of the marginal ice zone are studied.

Comiso, J. C.↗

Field test results with the targeted search MCSA

In April 1985, a 74,000 channel prototype of the multichannel spectrum analyzer (MCSA) that NASA plans to use in a systematic search for extraterrestrial intelligence (SETI) was installed at DSS13, a 26 meter R&D antenna facility at the Goldstone Deep Space Network (DSN) site. Since that time the instrumentation has been used to validate the performance of signal detection algorithms using locally injected signals and the weak carriers from distant spacecraft. This paper describes results from the Goldstone Field Tests and plans to move the prototype equipment to other sites where SETI may be conducted in the future.

Tarter, J. C.↗

OPAD 1991

The Optical Plume Anomaly Detection Program, an experimental study in the attempt to create a rocket engine health monitor based on detection and possible quantification of anomalous atomic and molecular species in the exhaust plume, has been in existence for several years. The instruments developed to monitor the exhaust plumes are presented. Two optical instruments are employed: the polychromator and the spectrometer. The polychromator is a 16 channel spectroradiometer having independent channels individually adjustable for center wavelength and pass bandwidth. Those values may be mechanically reset, with the aid of certain lab equipment. The spectrometer is a multichannel spectral analyzer having two 2048 element linear photodiode arrays at the exit plane of the dispersing instrument, which, like the 16 channel device, is a 1/2 meter grating spectrograph. These instruments are equipped with ultraviolet grade multifiber optical input cables, allowing the instruments to be placed in a benign environment. Telescopes mounted on the test stand observe the plume keeping the shock structure in view. The data acquisition and control system consist of four 80386-33 MHz computers: two at the test stand for instrument control and data preconditioning, and two in the test support building providing data archiving, display, and system control. Further descriptions of the instrumentation are provided.

Powers, W. T.↗

Design and Calibration of an Airborne Multichannel Swept-Tuned Spectrum Analyzer

This paper describes the design and calibration of a four-channel, airborne, swept-tuned spectrum analyzer used in two hypersonic flight experiments for characterizing dynamic data up to 25 kHz. Built mainly from commercially available analog function modules, the analyzer proved useful for an application with limited telemetry bandwidth, physical weight and volume, and electrical power. The authors discuss considerations that affect the frequency and amplitude calibrations, limitations of the design, and example flight data.

Hamory, Philip J.↗

Sensitive detection of narrowband pulses

Highly monochromatic signals, such as TV carriers, can be detected sensitively by using a narrow filter (b < or = 1 Hz) and performing power accumulation on its output. If instead a low-duty-cycle pulsed signal of the same total energy is present, the sensitivity of a square law device, followed by a thresholding operation (to eliminate most samples containing only noise), followed by the algorithm to be described, is greater by about 7 dB in typical cases. This is particularly interesting to SETI because such a pulsed signal is exactly what is sent by a rotating beacon with a directional antenna. Such a pulsed signal is, therefore, a good candidate for an extraterrestrial beacon. Software for detecting this signal type is now ready for field testing with the NASA Multichannel Spectrum Analyzer (MCSA).

NASA Discipline Number 52-60↗

A multichannel dual-mixer stability analyzer: progress report

A stability analyzer is being developed for frequency standards in JPL's Deep Space Network. Prototype hardware and software have been built. Initial tests on 100-MHz sources show an Allan deviation noise floor of about 7 X 10(sup -15) at 1 second for a dual-mixer channel.

frequency time stability dual mixer↗

Pulsed, Photonuclear-induced, Neutron Measurements of Nuclear Materials with Composite Shielding

Active measurements were performed using a 10-MeV electron accelerator with inspection objects containing various nuclear and nonnuclear materials available at the Idaho National Laboratory’s Zero Power Physics Reactor (ZPPR) facility. The inspection objects were assembled from ZPPR reactor plate materials to evaluate the measurement technologies for the characterization of plutonium, depleted uranium or highly enriched uranium shielded by both nuclear and non-nuclear materials. A series of pulsed photonuclear, time-correlated measurements were performed with unshielded calibration materials and then compared with the more complex composite shield configurations. The measurements used multiple 3He detectors that are designed to detect fission neutrons between pulses of an electron linear accelerator. The accelerator produced 10-MeV bremsstrahlung X-rays at a repetition rate of 125 Hz (8 ms between pulses) with a 4-us pulse width. All inspected objects were positioned on beam centerline and 100 cm from the X-ray source. The time-correlated data was collected in parallel using both a Los Alamos National Laboratory-designed list-mode acquisition system and a commercial multichannel scaler analyzer. A combination of different measurement configurations and data analysis methods enabled the identification of each object. This paper describes the experimental configuration, the ZPPR inspection objects used, and the various measurement and analysis results for each inspected object.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance of the Zeeman analyzer system of the McDonald Observatory 2.7 meter telescope

The paper describes a multichannel photoelectric Zeeman analyzer at the coude spectrograph of the McDonald 2.7 m reflector. A comparison of Lick and McDonald observations of HD 153882 reveals no significant difference in slopes or zero points of the two magnetic fields indicating that the systematic scale difference of 30-40% is probably instrumental in origin. Observations of the magnetic variable beta Cor Bor revealed a more nearly sinusoidal magnetic curve with less internal scatter than the photographically determined field measures of the Lick and Mauna Kea Zeeman systems. Investigation of periodicity in the secularly varying magnetic minima of beta Cor Bor did not yield evidence of previously noted periodicities other than that expected from the time structure of the data sampling.

Vogt, S. S.↗

Multichannel effects near confinement-induced resonances in harmonic waveguides

We analyze the impact of multichannel scattering in harmonic waveguides on the positions and widths of confinement-induced resonances for both isotropic and anisotropic transversal confinement. Multichannel scattering amplitudes and transmission coefficients are calculated and used to characterize the resonant behavior of atomic collisions with varying anisotropy. A mechanism is established which leads to a splitting of the confinement-induced resonance in the presence of anisotropy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

R-matrix Analysis of Reactions in the {sup 9}B Compound System

Recent activity in solving the ‘lithium problem’ in big bang nucleosynthesis has focused on the role that putative resonances may play in resonance-enhanced destruction of {sup 7}Li. Particular attention has been paid to the reactions involving the {sup 9}B compound nuclear system, d+{sup 7}Be→{sup 9}B. These reactions are analyzed via the multichannel, two-body unitary R-matrix method using the code EDA developed by Hale and collaborators. We employ much of the known elastic and reaction data, in a four-channel treatment. The data include elastic {sup 3}He+{sup 6}Li differential cross sections from 0.7 to 2.0 MeV, integrated reaction cross sections for energies from 0.7 to 5.0 MeV for {sup 6}Li({sup 3}He,p){sup 8}Be{sup *} and from 0.4 to 5.0 MeV for the {sup 6}Li({sup 3}He,d){sup 7}Be reaction. Capture data have been added to an earlier analysis with integrated cross section measurements from 0.7 to 0.825 MeV for {sup 6}Li({sup 3}He,γ){sup 9}B. The resulting resonance parameters are compared with tabulated values, and previously unidentified resonances are noted. Our results show that there are no near d+{sup 7}Be threshold resonances with widths that are 10's of keV and reduce the likelihood that a resonance-enhanced mass-7 destruction mechanism, as suggested in recently published work, can explain the {sup 7}Li problem.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct determination of lead-210 by liquid-scintillation counting

Soft betas, the internal conversion electrons, and unconverted gamma rays from lead-210 are efficiently detected in a liquid scintillation counting system with efficiency of 97 percent. The counter is interfaced with a multichannel pulse height analyzer. The spectra obtained is stored on paper tape and plotted on an x-y plotter.

Fairman, W. D.↗

A magnetic study of spotted UV Ceti flare stars and related late-type dwarfs

A multichannel photoelectric Zeeman analyzer has been used to investigate the magnetic nature of the spotted UV Ceti flare stars. Magnetic observations were obtained on a sample of 19 program objects, of which 5 were currently spotted dKe-dMe stars, 7 were normal dK-dM stars, 7 were UV Ceti flare stars, and 1 was a possible post-T Tauri star. Contrary to most previously published observations and theoretical expectations, no magnetic fields were detected on any of these objects from either the absorption lines or the H-alpha emission line down to an observational uncertainty level of 100-160 gauss (standard deviation).

Vogt, S. S.↗

Method and apparatus for mapping the distribution of chemical elements in an extended medium

Contaminants in an extended medium such as the wall of a building are mapped by locating neutron excitation source on one side of the wall and a gamma ray spectrometer, including a gamma ray detector on the opposite side of the wall facing the excitation source. The source and detector are moved in unison in discrete steps over opposing wall surfaces so as to determine the chemical composition of the elements in a hemispheric region of the wall adjacent the detector with the radius of the region being substantially that of the mean free path distance of gamma rays emitted from elements interacting with neutrons on the detector side of the wall. The source and detector are reversed for relatively thick walls for mapping the distribution of elements on the other side of the wall thickness. The output of the detector is fed to a multichannel pulse height analyzer where the intensity of the various gamma ray spectral lines are indicated relative to a dominant constituent element such as silicon. Resolution of anomalies such as the presence of voids and/or determining the bulk density of the medium is achieved by substituting a gamma ray source technique is also applied to metal alloys, such as iron alloys, in either the solid or molten state.

Evans, L. G.↗

Simulated measurement of power flow in structures near to simple sources and simple boundaries

Advances in electronics technology along with the advent of low cost multichannel Fast Fourier analyzers have made it practical to use higher order central difference formulas to measure power flow in 1- and 2-D structures. The method discussed uses five point differencing for the spatial derivatives in 1-D and a thirteen point difference pattern for the spatial derivatives in 2-D plates and shells. It is assumed that the measuring transducers are accelerometers. An analytical study of the higher order differencing method and the conventional two accelerometer method was performed as a preliminary to the application of these methods to actual aircraft structures. Some classical problems were analyzed in order to simulate and compare the performance of the two methods under near field measurement conditions. These near field conditions include examples of power flows near simple sources and simple boundaries. The estimates produced by the two methods were compared to the exact solution in each example. Presented are the theory and selected results of the study, which indicate that the bias errors of the two accelerometer method under near field measurement conditions may be much larger than previous studies have suggested.

Mcgary, Michael C.↗

An integrated radiation physics computer code system.

An integrated computer code system for the semi-automatic and rapid analysis of experimental and analytic problems in gamma photon and fast neutron radiation physics is presented. Such problems as the design of optimum radiation shields and radioisotope power source configurations may be studied. The system codes allow for the unfolding of complex neutron and gamma photon experimental spectra. Monte Carlo and analytic techniques are used for the theoretical prediction of radiation transport. The system includes a multichannel pulse-height analyzer scintillation and semiconductor spectrometer coupled to an on-line digital computer with appropriate peripheral equipment. The system is geometry generalized as well as self-contained with respect to material nuclear cross sections and the determination of the spectrometer response functions. Input data may be either analytic or experimental.

Steyn, J. J.↗

Effect of vegetation on soil moisture sensing observed from orbiting microwave radiometers

The microwave radiometric measurements made by the Skylab 1.4 GHz radiometer and by the 6.6 GHz and 10.7 GHz channels of the Nimbus-7 Scanning Multichannel Microwave Radiometer were analyzed to study the large-area soil moisture variations of land surfaces. Two regions in Texas, one with sparse and the other with dense vegetation covers, were selected for the study. The results gave a confirmation of the vegetation effect observed by ground-level microwave radiometers. Based on the statistics of the satellite data, it was possible to estimate surface soil moisture in about five different levels from dry to wet conditions with a 1.4 GHz radiometer, provided that the biomass of the vegetation cover could be independently measured. At frequencies greater than about 6.6 GHz, the radiometric measurements showed little sensitivity to moisture variation for vegetation-covered soils. The effects of polarization in microwave emission were studied also.

Wang, J. R.↗

NASA Tech Briefs, June 2005

Topics covered include: Apparatus Characterizes Transient Voltages in Real Time; Measuring Humidity in Sealed Glass Encasements; Adaptable System for Vehicle Health and Usage Monitoring; Miniature Focusing Time-of-Flight Mass Spectrometer; Cryogenic High-Sensitivity Magnetometer; Wheel Electrometer System; Carbon-Nanotube Conductive Layers for Thin-Film Solar Cells; Patch Antenna Fed via Unequal-Crossed-Arm Aperture; LC Circuits for Diagnosing Embedded Piezoelectric Devices; Nanowire Thermoelectric Devices; Code for Analyzing and Designing Spacecraft Power System Radiators; Decision Support for Emergency Operations Centers; NASA Records Database; Real-Time Principal- Component Analysis; Fuzzy/Neural Software Estimates Costs of Rocket- Engine Tests; Multicomponent, Rare-Earth-Doped Thermal-Barrier Coatings; Reactive Additives for Phenylethynyl-Containing Resins; Improved Gear Shapes for Face Worm Gear Drives; Alternative Way of Shifting Mass to Move a Spherical Robot; Parylene C as a Sacrificial Material for Microfabrication; In Situ Electrochemical Deposition of Microscopic Wires; Improved Method of Manufacturing SiC Devices; Microwave Treatment of Prostate Cancer and Hyperplasia; Ferroelectric Devices Emit Charged Particles and Radiation; Dusty-Plasma Particle Accelerator; Frozen-Plug Technique for Liquid-Oxygen Plumbing; Shock Waves in a Bose-Einstein Condensate; Progress on a Multichannel, Dual-Mixer Stability Analyzer; Development of Carbon- Nanotube/Polymer Composites; Thermal Imaging of Earth for Accurate Pointing of Deep-Space Antennas; Modifications of a Composite-Material Combustion Chamber; Modeling and Diagnostic Software for Liquefying- Fuel Rockets; and Spacecraft Antenna Clusters for High EIRP.

Source record↗