Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “moving mirrors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Crack growth in single-crystal silicon

Crack growth in single-crystal silicon at room temperature in air was evaluated by double torsion (DT) load-relaxation method and monitored by acoustic emission (AE) technique. Both DT and AE methods indicated lack of subcritical crack growth in silicon. At the critical stress intensity factor, the crack front was found to be jumping several times in a 'mirror' region and then followed by fast crack growth in a 'hackle' region. Hackle marks were found to be associated with plastic deformation at the tip of the fast moving crack. No dislocation etch pits were found in the 'mirror' region, in which crack growth may result from interatomic bonds broken at the crack tip under stress without any plastic deformation. Acoustic emission appears to be spontaneously generated from both interatomic bonds broken and dislocation generation at the moving crack tip during the crack growth in single-crystal silicon.

Chen, C. P.↗

Resolution enhanced sound detecting apparatus

An apparatus is described for enhancing the resolution of a sound detector of the type which includes an acoustic mirror for focusing sound from an object onto a microphone to enable the determination of the location from which the sound arises. The enhancement apparatus includes an enclosure which surrounds the space between the mirror and microphone, and contains a gas heavier than air, such as Freon, through which sound moves slower and therefore with a shorter wavelength than in air, so that a mirror of given size has greater resolving power. An acoustically transparent front wall of the enclosure which lies forward of the mirror, can include a pair of thin sheets with pressured air between them, to form an end of the region of heavy gas into a concave shape.

Kendall, J. M.↗

Decay of equatorial ring current ions and associated aeronomical consequences

The decay of the major ion species which constitute the ring current is studied by solving the time evolution of their distribution functions during the recovery phase of a moderate geomagnetic storm. In this work, only equatorially mirroring particles are considered. Particles are assumed to move subject to E x B and gradient drifts. They also experience loses along their drift paths. Two loss mechanisms are considered: charge exchange with neutral hydrogen atoms and Coulomb collisions with thermal plasma in the plasmasphere. Thermal plasma densities are calculated with a plasmaspheric model employing a time-dependent convection electric field model. The drift-loss model successfully reproduces a number of important and observable features in the distribution function. Charge exchange is found to be the major loss mechanism for the ring current ions; however the important effects of Coulomb collisions on both the ring current and thermal populations are also presented. The model predicts the formation of a low-energy (less than 500 eV) ion population as a result of energy degradation caused by Coulomb collision of the ring current ions with the plasmaspheric electrons; this population may be one source of the low-energy ions observed during active and quiet periods in the inner magnetosphere. The energy transferred to plasmaspheric electrons through Coulomb collisions with ring current ions is believed to be the energy source for the electron temperature enhancement and the associated 6300 A (stable auroral red (SAR) arc) emission in the subauroral region. The calculated energy deposition rate is sufficient to produce a subauroral electron temperature enhancement and SAR arc emissions that are consistent with observations of these quantities during moderate magnetic activity levels.

Fok, M.-C.↗

System and method for tracking a signal source

A system for tracking moving signal sources is disclosed which is particularly adaptable for use in tracking stage performers. A miniature transmitter is attached to the person or object to be tracked and emits a detectable signal of a predetermined frequency. A plurality of detectors positioned in a preset pattern sense the signal and supply output information to a phase detector which applies signals representing the angular orientation of the transmitter to a computer. The computer provides command signals to a servo network which drives a device such as a motor driven mirror reflecting the beam of a spotlight, to track the moving transmitter.

Mogavero, L. N.↗

Localized Ionospheric Particle Acceleration and Wave Acceleration of Auroral Ions: Amicist Data Set

Research supported by this grant covered two main topics: auroral ion acceleration from ELF-band wave activity, and from VLF-spikelet (lower hybrid solitary structure) wave activity. Recent auroral sounding rocket data illustrate the relative significance of various mechanisms for initiating auroral ion outflow. Two nightside mechanisms are shown in detail. The first mechanism is ion acceleration within lower hybrid solitary wave events. The new data from this two payload mission show clearly that: (1) these individual events are spatially localized to scales approximately 100 m wide perpendicular to B, in agreement with previous investigations of these structures, and (2) that the probability of occurrence of the events is greatest at times of maximum VLF wave intensity. The second mechanism is ion acceleration by broadband, low frequency electrostatic waves, observed in a 30 km wide region at the poleward edge of the arc. The ion fluxes from the two mechanisms are compared and it is shown that while lower hybrid solitary structures do indeed accelerate ions in regions of intense VLF waves, the outflow from the electrostatic ion wave acceleration region is dominant for the aurora investigated by this sounding rocket, AMICIST. The fluxes are shown to be consistent with DE-1 and Freja outflow measurements, indicating that the AMICIST observations show the low altitude, microphysical signatures of nightside auroral outflow. In this paper, we present a review of sounding rocket observations of the ion acceleration seen nightside auroral zone lower hybrid solitary structures. Observations from Topaz3, Amicist, and Phaze2 are presented on various spatial scales, including the two-point measurements of the Amicist mission. From this collection of observations, we will demonstrate the following characteristics of transverse ion acceleration (TAI) in LHSS. The ion acceleration process is narrowly confined to 90 degrees pitch angle, in spatially confined regions of up to a few hundred meters across B. The acceleration process does not affect the thermal core of the ambient distribution, and does not directly create a measurable effect on the ambient ion population outside the LHSS themselves. Within the LHSS region, it creates a high energy tail beginning at a few times the thermal ion speed. The ion acceleration events are closely associated with localized wave events. Accelerated ions bursts are also seen without a concurrent observation of a localized wave event, for two possible reasons. In some cases, the pitch angles of the accelerated tail ions are elevated above perpendicular; that is to say, the acceleration occurred below the observer and the mirror force has begun to act upon the distribution, moving it upward from the source. In other cases, the accelerated ion structure is spatially larger than the wave event structure, and the observation catches only the ion event. The occurrence rate of these ion acceleration events is related to the ambient environment in two ways: (1) its altitude dependence can be modelled with the parameter B(exp2)/n(sub e), (2) and it is highest in regions of intense VLF activity. The end result of this study of auroral ion acceleration processes is a manuscript entitled "Auroral Ion Acceleration from Lower Hybrid Solitary Structures: A Summary of Sounding Rocket Observations", by Lynch, Arnoldy, Kintner, Schuck, Bonnell, and Coffey. This manuscript has been submitted for publication to the Journal of Geophysical Research.

Lynch, Kristina A.↗

AXAF Coordinate Transformation at XRCF

Coordinate transformation between focal plane and detector pixel systems must be handled carefully at the X-ray Calibration Facility (XRCF) as it will be during flight. The High Resolution Mirror Assembly (HRMA) X-ray Detection System (HXDS) stage dithers, and the five-axis mount (FAM) attachment points underwent various types of motion during testing. At the XRCF when the FAM moved, the Science Instrument Module (SIM) travel direction was not necessarily aligned with the mirror axis motion, and, in addition, an arbitrary position offset had to be calibrated. Misalignment from the mirror axis was assessed by measuring its displacement from the boresight configuration of the default FAM frame, and the HXDS stage was monitored for motion from the default FAM reference point. Mirror position, prescribed in a mirror modal coordinate system, was measured in HRMA pitch and yaw axes. Prior to corrections for dithering and FAM movement, the coordinate data at XRCF also had to be corrected for possible misalignments of the mirror mount relative to XRCF and the default FAM axes due to the movement of the FAM feet. Those misalignments were processed in terms of yaw-pitch-roll Euler angles in the mirror nodal coordinate, and in the default FAM frame, respectively. An AXAF Science Center (ASC) coordinate library, pixlib, has been built to support these coordinate transformations and was used during x-ray calibration at the George C. Marshall Space Flight Center, Huntsville, AL. The design and implementation of this library will be discussed.

He, Helen↗

The parathyroid hormone circadian rhythm is truly endogenous--a general clinical research center study

While circulating levels of PTH follow a diurnal pattern, it has been unclear whether these changes are truly endogenous or are dictated by external factors that themselves follow a diurnal pattern, such as sleep-wake cycles, light-dark cycles, meals, or posture. We evaluated the diurnal rhythm of PTH in 11 normal healthy male volunteers in our Intensive Physiologic Monitoring Unit. The first 36 h spent under baseline conditions were followed by 28-40 h of constant routine conditions (CR; enforced wakefulness in the strict semirecumbent position, with the consumption of hourly snacks). During baseline conditions, PTH levels followed a bimodal diurnal rhythm with an average amplitude of 4.2 pg/mL. A primary peak (t1max) occurred at 0314 h, and the secondary peak (t2max) occurred at 1726 h, whereas the primary and secondary nadirs (t1min and t2min) took place, on the average, at 1041 and 2103 h, respectively. This rhythm was preserved under CR conditions, albeit with different characteristics, thus confirming its endogenous nature. The serum ionized calcium (Cai) demonstrated a rhythm in 3 of the 5 subjects studied that varied widely between individuals and did not have any apparent relation to PTH. Urinary calcium/creatinine (UCa/Cr), phosphate/Cr (UPO4/Cr), and sodium/Cr (UNa/Cr) ratios all followed a diurnal rhythm during the baseline day. These rhythms persisted during the CR, although with different characteristics for the first two parameters, whereas that of UNa/Cr was unchanged. In general, the temporal pattern for the UCa/Cr curve was a mirror image of the PTH curve, whereas the UPO4/Cr pattern moved in parallel with the PTH curve. In conclusion, PTH levels exhibit a diurnal rhythm that persists during a CR, thereby confirming that a large component of this rhythm is an endogenous circadian rhythm. The clinical relevance of this rhythm is reflected in the associated rhythms of biological markers of PTH effect at the kidney, namely UCa/Cr and UPO4/Cr.

NASA Discipline Musculoskeletal↗

LEC System Development

The Lajet Energy Company (LEC) 460 is described. A parabolic dish which incorporates a microprocessor to automatically point it toward the Sun from sunrise to sunset is used. The dish is composed of a set of mirrors (made of reflective polymeric film) which focus and concentrate the Sun's energy on a receiver, producing intense but controlled amounts of heat. The LEC 460 employs a design concept that permits the use of common and low cost materials. All major structural components are fabricated from low carbon, low alloy steel using methods adaptable to mass production. The mirrors are supported on a steel tubing frame. This frame is attached near its center of gravity to a cantilevered support structure. The mirrors and frame are counterbalanced by the weight of the receiver, thus reducing the energy needed to move the collector (parasitic load) and allowing movement on two axes. Each LEC 460 solar concentrator contains a reflective array consisting of twenty four 60 inch diameter mirrors.

Halbert, D. D.↗

Visual imaging control systems of the Mariner to Jupiter and Saturn spacecraft

Design and fabrication of optical systems for the Mariner Jupiter Saturn (Voyager) mission is described. Because of the long distances of these planets from the sun, the spacecraft was designed without solar panels with the electricity generated on-board by radio-isotope thermal generators (RTG). The presence of RTG's and Jupiter radiation environment required that the optical systems be fabricated out of radiation stabilized materials. A narrow angle and a wide angle camera are located on the spacecraft scan platform, with the narrow angle lens a modification of the Mariner 10 lens. The optical system is described, noting that the lens was modified by moving the aperture correctors forward and placing a spider mounted secondary mirror in the original back surface of the second aperture corrector. The wide angle lens was made out of cerium doped, radiation stabilized optical glass with greatest blue transmittance, which would be resistant to RTG and Jupiter radiation.

Larks, L.↗

Compensating For Movement Of Eye In Laser Surgery

Conceptual system for laser surgery of retina includes subsystem that tracks position of retina. Tracking signal used to control galvanometer-driven mirrors keeping laser aimed at desired spot on retina as eye moves. Alternatively or additionally, indication of position used to prevent firing of laser when eye moved too far from proper aiming position.

Juday, Richard D.↗

Vibration Pattern Imager (VPI): A control and data acquisition system for scanning laser vibrometers

The Vibration Pattern Imager (VPI) system was designed to control and acquire data from scanning laser vibrometer sensors. The PC computer based system uses a digital signal processing (DSP) board and an analog I/O board to control the sensor and to process the data. The VPI system was originally developed for use with the Ometron VPI Sensor, but can be readily adapted to any commercially available sensor which provides an analog output signal and requires analog inputs for control of mirror positioning. The sensor itself is not part of the VPI system. A graphical interface program, which runs on a PC under the MS-DOS operating system, functions in an interactive mode and communicates with the DSP and I/O boards in a user-friendly fashion through the aid of pop-up menus. Two types of data may be acquired with the VPI system: single point or 'full field.' In the single point mode, time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and is stored by the PC. The position of the measuring point (adjusted by mirrors in the sensor) is controlled via a mouse input. The mouse input is translated to output voltages by the D/A converter on the I/O board to control the mirror servos. In the 'full field' mode, the measurement point is moved over a user-selectable rectangular area. The time series data is sampled by the A/D converter on the I/O board (at a user-defined sampling rate for a selectable number of samples) and converted to a root-mean-square (rms) value by the DSP board. The rms 'full field' velocity distribution is then uploaded for display and storage on the PC.

Rizzi, Stephen A.↗

Assessing the Impact of Mirror Technology on Driver Perception and Safety: Traditional vs. Camera-Based Systems

Camera-based mirror systems (CBMS) are being adopted by commercial fleets based on the potential improvements to operational efficiency through improved aerodynamics, resulting in better fuel economy, improved maneuverability, and the potential improvement for overall safety. Until CBMS are widely adopted it will be expected that drivers will be required to adapt to both conventional glass mirrors and CBMS which could have potential impact on the safety and performance of the driver when moving between vehicles with and without CBMS. To understand the potential impact to driver perception and safety, along with other human factors related to CBMS, laboratory testing was performed to understand the impact of CBMS and conventional glass mirrors. Drivers were subjected to various, nominal driving scenarios using a truck equipped with conventional glass mirrors, CBMS, and both glass mirrors and CBMS, to observe the differences in metrics such as head and eye movement, reaction time, and perception of distance. The finds from this study will serve as the baseline measurements for future research regarding off-nominal driving scenarios and hardware failures of CBMS, as well as inform potential future policy regarding CBMS for the use in commercial vehicles in lieu of conventional glass mirrors.

Siekmann, Adam [ORNL] (ORCID:0000000284653935)↗

Solar power for the lunar night

Providing power over the 354 hour lunar night provides a considerable challenge to solar power concepts for a moonbase. Concepts are reviewed for providing night power for a solar powered moonbase. The categories of solutions considered are electrical storage, physical storage, transmitted power, and innovative concepts. Electrical storage is the most well-developed option. Less developed electrical storage options are capacitors and superconducting inductors. Physical storage options include storage of potential energy and storage of energy in flywheels. Thermal storage has potentially high energy/weight, but problems of conduction and radiation losses during the night need to be addressed. Transmitted power considers use of microwave or laser beams to transmit power either from orbit or directly from the Earth. Finally, innovative concepts proposed include reflecting light from orbital mirrors, locating the moonbase at a lunar pole, converting reflected Earthlight, or moving the moonbase to follow the sun.

Landis, Geoffrey A.↗

Solar power for the lunar night

Providing power over the 354 hour lunar night provides a considerable challenge to solar power concepts for a moonbase. Concepts are reviewed for providing night power for a solar powered moonbase. The categories of solutions considered are electrical storage, physical storage, transmitted power, and innovative concepts. Electrical storage is the most well-developed option. Less developed electrical storage options are capacitors and superconducting inductors. Physical storage options include storage of potential energy and storage of energy in flywheels. Thermal storage has potentially high energy/weight, but problems of conduction and radiation losses during the night need to be addressed. Transmitted power considers use of microwave or laser beams to transmit power either from orbit or directly from the earth. Finally, innovative concepts proposed include reflecting light from orbital mirrors, locating the moonbase at a lunar pole, converting reflected earthlight, or moving the moonbase to follow the sun.

Landis, Geoffrey A.↗

4D Light Field Imaging System Using Programmable Aperture

Complete depth information can be extracted from analyzing all angles of light rays emanated from a source. However, this angular information is lost in a typical 2D imaging system. In order to record this information, a standard stereo imaging system uses two cameras to obtain information from two view angles. Sometimes, more cameras are used to obtain information from more angles. However, a 4D light field imaging technique can achieve this multiple-camera effect through a single-lens camera. Two methods are available for this: one using a microlens array, and the other using a moving aperture. The moving-aperture method can obtain more complete stereo information. The existing literature suggests a modified liquid crystal panel [LC (liquid crystal) panel, similar to ones commonly used in the display industry] to achieve a moving aperture. However, LC panels cannot withstand harsh environments and are not qualified for spaceflight. In this regard, different hardware is proposed for the moving aperture. A digital micromirror device (DMD) will replace the liquid crystal. This will be qualified for harsh environments for the 4D light field imaging. This will enable an imager to record near-complete stereo information. The approach to building a proof-ofconcept is using existing, or slightly modified, off-the-shelf components. An SLR (single-lens reflex) lens system, which typically has a large aperture for fast imaging, will be modified. The lens system will be arranged so that DMD can be integrated. The shape of aperture will be programmed for single-viewpoint imaging, multiple-viewpoint imaging, and coded aperture imaging. The novelty lies in using a DMD instead of a LC panel to move the apertures for 4D light field imaging. The DMD uses reflecting mirrors, so any light transmission lost (which would be expected from the LC panel) will be minimal. Also, the MEMS-based DMD can withstand higher temperature and pressure fluctuation than a LC panel can. Robotics need near complete stereo images for their autonomous navigation, manipulation, and depth approximation. The imaging system can provide visual feedback

Bae, Youngsam↗

Range Imaging without Moving Parts

Range-imaging instruments of a type now under development are intended to generate the equivalent of three-dimensional images from measurements of the round-trip times of flight of laser pulses along known directions. These instruments could also provide information on characteristics of targets, including roughnesses and reflectivities of surfaces and optical densities of such semi-solid objects as trees and clouds. Unlike in prior range-imaging instruments based on times of flight along known directions, there would be no moving parts; aiming of the laser beams along the known directions would not be accomplished by mechanical scanning of mirrors, prisms, or other optical components. Instead, aiming would be accomplished by using solid-state devices to switch input and output beams along different fiber-optic paths. Because of the lack of moving parts, these instruments could be extraordinarily reliable, rugged, and long-lasting. An instrument of this type would include an optical transmitter that would send out a laser pulse along a chosen direction to a target. An optical receiver coaligned with the transmitter would measure the temporally varying intensity of laser light reflected from the target to determine the distance and surface characteristics of the target. The transmitter would be a combination of devices for generating precise directional laser illumination. It would include a pulsed laser, the output of which would be coupled into a fiber-optic cable with a fan-out and solid-state optical switches that would enable switching of the laser beam onto one or more optical fibers terminated at known locations in an array on a face at the focal plane of a telescope. The array would be imaged by the telescope onto the target space. The receiver optical system could share the aforementioned telescope with the transmitter or could include a separate telescope aimed in the same direction as that of the transmitting telescope. In either case, light reflected from the target would be focused by the receiver optical system onto an array of optical fibers matching the array in the transmitter. These optical fibers would couple the received light to one or more photodetector( s). Optionally, the receiver could include solid-state optical switches for choosing which optical fiber(s) would couple light to the photodetector(s). This instrument architecture is flexible and can be optimized for a wide variety of applications and levels of performance. For example, it is scalable to any number of pixels and pixel resolutions and is compatible with a variety of ranging and photodetection methodologies, including, for example, ranging by use of modulated (including pulsed and encoded) light signals. The use of fixed arrays of optical fibers to generate controlled illumination patterns would eliminate the mechanical complexity and much of the bulk of optomechanical scanning assemblies. Furthermore, digital control of the selection of the fiber-optic pathways for the transmitted beams could afford capabilities not seen in previous three-dimensional range-imaging systems. Instruments of this type could be specialized for use as, for example, proximity detectors, three-dimensional robotic vision systems, airborne terrain-mapping systems, and inspection systems.

Blair, J. Bryan↗

Dynamic Analyses of the Proposed Habitable Exoplanet Astrophysics Facility

The proposed Habitable Exoplanet (HabEx) astrophysics facility is one of four large such facilities being proposed to the 2020 decadal. It is a large telescope that is sensitive to ultraviolet, optical, and near-infrared photons. The proposed design’s overall length is on the order of 17.2 m and its maximum cross section is on the order of 5.25 X 5.25 m. The primary mirror is 4 m in diameter. A transient dynamic analysis was performed to estimate the order of magnitude of ring down time after moving the telescope and pointing at a new target for science planning purposes. Without uncertainty factors, results from a simple re-pointing maneuver indicate that primary to secondary mirror LOS errors are on the order of 10-4 pico-m after 5 minutes. Also, a frequency response analysis was performed to predict the impact of planned micro-thruster vibrations on required stability. Based on provided noise level associated with the micro-thrusters and loading assumptions and without uncertainty factors, the assessed vibrations do not impact predicted performance requirements.

Knight, J. Brent↗

LDR structural experiment definition

A system study to develop the definition of a structural flight experiment for a large precision segmented reflector on the Space Station was accomplished by the Boeing Aerospace Company for NASA's Langley Research Center. The objective of the study was to use a Large Deployable Reflector (LDR) baseline configuration as the basis for focusing an experiment definition, so that the resulting accommodation requirements and interface constraints could be used as part of the mission requirements data base for Space Station. The primary objectives of the first experiment are to construct the primary mirror support truss and to determine its structural and thermal characteristics. Addition of an optical bench, thermal shield and primary mirror segments, and alignment of the optical components, would occur on a second experiment. The structure would then be moved to the payload point system for pointing, optical control, and scientific optical measurement for a third experiment. Experiment 1 will deploy the primary support truss while it is attached to the instrument module structure. The ability to adjust the mirror attachment points and to attach several dummy primary mirror segments with a robotic system will also be demonstrated. Experiment 2 will be achieved by adding new components and equipment to experiment one. Experiment 3 will demonstrate advanced control strategies, active adjustment of the primary mirror alignment, and technologies associated with optical sensing.

Russell, R. A.↗