Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “monochromators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

106 records · Page 6

Electron Energy-Loss Spectroscopy and Differential Phase Contrast Imaging with Active Decision in Multimodal Electron Microscopy: Isotopic detection at the atomic scale

Isotopic engineering provides a powerful route to control phonon behavior in crystalline solids, enabling fundamental studies of lattice dynamics and heat transport at the atomic scale. Here, we directly visualize isotope-dependent phonon propagation in epitaxial Cr 2 O 3 using aberration-corrected scanning transmission electron microscopy (STEM) combined with monochromated, high-energy-resolution electron energy-loss spectroscopy (EELS). Guided by ab initio phonon calculations, we demonstrate that optical phonon modes above 70 meV are predominantly oxygen-derived and exhibit measurable redshifts upon substitution of natural 16 O by enriched 18 O. Spatially resolved vibrational spectrum imaging reveals isotope-enriched tracer layers within Cr 2 O 3 thin films, correlating isotope concentration with phonon intensity variations and vibrational energy shifts. At the nanometer and atomic scales, vibrational EELS mapping uncovers coherent phonon propagation across isotopic interfaces, consistent with theoretical phonon density of states and dispersion relations. These results establish vibrational EELS as a quantitative probe for isotope-dependent phonon transport in materials, opening new possibilities for studying energy dissipation and lattice dynamics.

36 MATERIALS SCIENCE↗

Spectral Radiative Properties of Polydispersed SiO 2 Particle Beds

The focus of this work is on the measurement and analysis of the radiative properties of polycrystalline SiO 2 particle beds with various layer thicknesses. The particles are polydispersed with average diameters of 222, 150, and 40 μm . The spectral, directional–hemispherical reflectance and transmittance of the particle bed are measured at wavelengths from 0.4 to 1.8 μm using a monochromator, and the reflectance measurement is extended to 15 μm using a Fourier-transform infrared spectrometer. Particles are closely packed between two transparent windows for measuring the radiative properties. In the visible and near-infrared region up to 1.8 μm, the inverse adding–doubling method yields the effective absorption and scattering coefficients. The results suggest that short wavelength absorption needs to be included in modeling the behavior of particle beds due to multiple scattering. A discrete-scale Monte Carlo ray-tracing method is developed to model the radiative properties by assuming monodispersed spherical particles, and the simulated results compare well with measurements. The effective absorption and scattering coefficients of the particle beds obtained from the independent scattering theory are compared to those from the inverse method. As a result, the impact of dependent scattering on the packed beds is observed for smaller-sized particles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-Stage Wildlife Event Classification for Edge Deployment

Camera-based wildlife monitoring is often overwhelmed by non-target triggers and slowed by manual review or cloud-dependent inference, which can prevent timely intervention for high stakes human–wildlife conflicts. Our key contribution is a deployable, fully offline edge vision sensor that achieves near-real-time, highly accurate wildlife event classification by combining detector-based empty-image suppression with a lightweight classifier trained with a staged transfer-learning curriculum. Specifically, Stage 1 uses a pretrained You Only Look Once (YOLO)-family detector for permissive animal localization and empty-trigger suppression, and Stage 2 uses a lightweight EfficientNet-based binary classifier to confirm puma on detector crops and gate downstream actions. Our design is robust to low-quality nighttime monochrome imagery (motion blur, low contrast, illumination artifacts, and partial-body captures) and operates using commercially available components in connectivity-limited settings. In field deployments running since May 2025, end-to-end latency from camera trigger to action command is approximately 4 s. Ablation studies using a dataset of labeled wildlife images (pumas, not pumas) show that the two-stage approach substantially reduces false alarms in identifying pumas relative to a full-image classifier while maintaining high recall. On the held-out test set (N = 1434 events), the proposed two-stage cascade achieves precision 0.983, recall 0.975, F1 0.979, accuracy 0.986, and balanced accuracy 0.983, with only 8 false positives and 12 false negatives. The system can be easily adapted for other species, as demonstrated by rapid retraining of the second stage to classify ringtails. Downstream responses (e.g., notifications and optional audio/light outputs) provide flexible actuation capabilities that can be configured to support intervention.

58 GEOSCIENCES↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Visualization of Thermal and Strain Dynamics in X-ray Optics by Time-Resolved Rocking Curve Imaging

The absorption of intense X-ray pulses from free-electron lasers by X-ray crystal optics triggers rapid thermal and mechanical responses, including lattice compression, expan- sion, and strain-wave propagation, which dynamically modify diffraction conditions and wavefront properties. These effects pose significant challenges for next-generation high- repetition-rate X-ray sources, particularly for crystal monochromators used in XFEL beam- lines and self-seeding. Here, we demonstrate time-resolved rocking curve imaging (TrRCI) of X-ray Bragg optics with high spatial resolution (6.4 μm) and sub-1-μrad angular resolu- tion, enabling direct visualization of lattice dynamics from nanoseconds to microseconds. By combining a high-flux beamline at SPring-8, a scintillator-coupled sCMOS detector, and a synchronized femtosecond laser system, we capture lattice dynamics induced by tran- sient laser heating with a strain sensitivity on the order of 10−6 . Our results reveal transient lattice deformation and the propagation of laser-induced strain waves over millimeter-scale distances. This approach provides experimental benchmarks for understanding heat-load effects in high-repetition-rate X-ray optics.

Source record↗

Low‐Loss Tunable Infrared Plasmons in the High‐Mobility Perovskite (Ba,La)SnO 3

Abstract BaSnO 3 exhibits the highest carrier mobility among perovskite oxides, making it ideal for oxide electronics. Collective charge carrier oscillations known as plasmons are expected to arise in this material, thus providing a tool to control the nanoscale optical field for optoelectronics applications. Here, the existence of relatively long‐lived plasmons supported by high‐mobility charge carriers in La‐doped BaSnO 3 (BLSO) is demonstrated. By exploiting the high spatial and energy resolution of electron energy‐loss spectroscopy with a focused beam in a scanning transmission electron microscope, the dispersion, confinement ratio, and damping of infrared localized surface plasmons (LSPs) in BLSO nanoparticles are systematically investigated. It is found that LSPs in BLSO exhibit a high degree of spatial confinement compared to those sustained by noble metals and have relatively low losses and high quality factors with respect to other doped oxides. Further analysis clarifies the relation between plasmon damping and carrier mobility in BLSO. The results support the use of nanostructured degenerate semiconductors for plasmonic applications in the infrared region and establish a solid alternative to more traditional plasmonic materials.

36 MATERIALS SCIENCE↗

A versatile Johansson-type tender x-ray emission spectrometer

We present a high energy resolution x-ray spectrometer for the tender x-ray regime (1.6–5.0 keV) that was designed and operated at Stanford Synchrotron Radiation Lightsource. The instrument is developed on a Rowland geometry (500 mm of radius) using cylindrically bent Johansson analyzers and a position sensitive detector. By placing the sample inside the Rowland circle, the spectrometer operates in an energy-dispersive mode with a subnatural line-width energy resolution (~0.32 eV at 2400 eV), even when an extended incident x-ray beam is used across a wide range of diffraction angles (~30° to 65°). The spectrometer is enclosed in a vacuum chamber, and a sample chamber with independent ambient conditions is introduced to enable a versatile and fast-access sample environment (e.g., solid/gas/liquid samples, in situ cells, and radioactive materials). The design, capabilities, and performance are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron characterization of high-Z, current-mode x-ray detectors

Fast x-ray detectors are critical tools in pulsed power and fusion applications, where detector impulse response of a nanosecond or better is often required. Semiconductor detectors can create fast, sensitive devices with extensive operational flexibility. There is typically a trade-off between detector sensitivity and speed, but higher atomic number absorbers can increase hard x-ray absorption without increasing the charge collection time, provided carriers achieve high velocity. This paper presents x-ray pulse characterization conducted at the Advanced Photon Source of x-ray absorption efficiency and temporal impulse response of current-mode semiconductor x-ray detectors composed of Si, GaAs, and CdTe.

47 OTHER INSTRUMENTATION↗

Skyrmion fluctuations at a first-order phase transition boundary

Magnetic skyrmions are topologically protected spin textures with promising prospects for applications in data storage. They can form a lattice state due to competing magnetic interactions and are commonly found in a small region of the temperature—magnetic field phase diagram. Recent work has demonstrated that these magnetic quasi-particles fluctuate at the μeV energy scale. Here, we use a coherent x-ray correlation method at an x-ray free-electron laser to investigate these fluctuations in a magnetic phase coexistence region near a first-order transition boundary where fluctuations are not expected to play a major role. Surprisingly, we find that the relaxation of the intermediate scattering function at this transition differs significantly compared to that deep in the skyrmion lattice phase. The observation of a compressed exponential behavior suggests solid-like dynamics, often associated with jamming. We assign this behavior to disorder and the phase coexistence observed in a narrow field-window near the transition, which can cause fluctuations that lead to glassy behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relationship between charge transfer state electroluminescence and the degradation of organic photovoltaics

The degradation of archetype organic photovoltaics comprising both vacuum and solution-deposited bulk heterojunction active regions is investigated and quantified using a theory based on detailed balance, which relates the open-circuit voltage to the efficiency of charge transfer state emission. To describe this relationship, we account for the difference between electroluminescent external quantum efficiency and the charge transfer emission efficiency. Here, an empirical factor, m, is introduced to distinguish between nonradiative defect sites both within, m = 1, and outside, m >1, of the photoactive heterojunction. The m-factor is used to determine the primary sources of degradation for archetype solution- and vacuum-processed material systems. We conclude that degradation occurs primarily within the donor–acceptor heterojunction for the vacuum-processed devices (where m = 1.020 ± 0.002) and outside of the photoactive heterojunction for the solution-processed devices studied, both with and without an anode buffer layer (where m = 2.93 ± 0.09 and m = 1.90 ± 0.01, respectively).

14 SOLAR ENERGY↗

Photoluminescence and Raman mapping of β-Ga 2 O 3

Semi-insulating single crystal β-Ga 2 O 3 is becoming increasingly useful as a substrate for device fabrication. Fe doping is a method for producing such substrates. Along with Fe dopants, β-Ga 2 O 3 :Fe also contains Cr 3+ . Photoluminescence (PL) emission peaks at 690 nm (1.80 eV) and 696 nm (1.78 eV), as well as a broad feature around 709 nm (1.75 eV), are observed in β-Ga 2 O 3 :Fe. PL mapping of the 690 nm emission showed high and low intensity bands due to impurity striations introduced during crystal growth. PL mapping also revealed surface defects showing broad emissions around 983 nm (1.26 eV) and 886 nm (1.40 eV) that were spatially localized, occurring at discrete spots on the sample surface. Raman mapping of an 886 nm emission center revealed peaks at 2878 and 2930 cm -1 , consistent with an organometallic or hydrocarbon compound. Raman mapping of the 983 nm center showed a peak at 2892 cm -1 . Bright UV emission centers showed Raman peaks at 2910 and 2968 cm -1 , which are attributed to Si-CH 3 groups that may originate from silica polishing compounds or annealing in a silica ampoule.

36 MATERIALS SCIENCE↗

The high intensity diffractometer for residual stress analysis (HIDRA), a third generation residual stress mapping neutron diffractometer at the high flux isotope reactor

This paper describes the hardware and software upgrades, operation, and performance of the high intensity diffractometer for residual stress analysis (HIDRA) instrument, a residual stress mapping neutron diffractometer located at the High Flux Isotope Reactor at Oak Ridge National Laboratory in Oak Ridge Tennessee, USA. Following a major upgrade in 2018, the new instrument has a single 3 He multiwire 2D 30 × 30 cm 2 position sensitive detector, yielding a field of view of 17° 2θ. Further, the increase in the field of view (from 4° 2θ) from the previous model instrument has contributed to the tremendous improvement in the out of plane solid angle such that the 3D count rate could be obtained easily. Accordingly, the hardware, software, Data Acquisition System (DAS), and so on have also been updated. Finally, all these enhanced features of HIDRA have been ably demonstrated by conducting multi directional diffraction measurements in the quenched 750-T74 aluminum, and the evolved and improved strain/stress mappings are presented.

3D printing↗

High-sensitivity electronic Stark spectrometer featuring a laser-driven light source

We report developmental details of a high-sensitivity Stark absorption spectrometer featuring a laser-driven light source. The light source exhibits intensity fluctuations of ~0.3% over timescales ranging from 1 min to 12 h, minimal drift (≤0.1%/h), and very little 1/f noise at frequencies greater than 200 Hz, which are comparable to or better than an arc-driven light source. Additional features of the spectrometer include balanced detection with multiplex sampling, which yielded lower noise in A, and constant wavelength or wavenumber (energy) spectral bandpass modes. We achieve noise amplitudes of ~7 × 10 –4 and ~6 × 10 –6 in measurements of single A and ΔA spectra (with 92 data points) taking ~7 and ~19 min, respectively.

47 OTHER INSTRUMENTATION↗

Design of an epithermal neutron velocity selection system for the Penn State Breazeale Reactor

A series of mechanical neutron choppers to operate as a velocity selection system have been developed for the Pennsylvania State Breazeal Reactor (PSBR). This chopper system will provide pulsed epithermal neutrons in the energy range of 0.5–40 eV with 2% or better energy resolution, and with a transmission of 1E-6 or better. Four different chopper geometries have been evaluated for their utility as mechanical neutron choppers. Specifically, Fermi, ring, piston, and disc choppers have been evaluated to assess their potential neutronics performance and mechanical constructability. A series of high-speed disc choppers were selected for the final design, and optimization work was performed to maximize the neutron pulse intensity. It is estimated that the optimized system will produce an epithermal neutron intensity of approximately 96 n/s. This system can also be operated in a time of flight (TOF) configuration such that the neutrons arriving at the source have a white spectrum. This operation can be accomplished by leaving the second stage of choppers in the open position, or by removing it from the beam completely. Such unique source of epithermal neutrons produced by this chopper system will have applications in both prompt and delayed epithermal neutron activation analysis (ENAA), as well as in neutron resonance transmission analysis (NRTA).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thorium model and weak 5f delocalization

Recently, it was demonstrated that an empirical model based on bremsstrahlung isochromat spectroscopy of elemental thorium (Th) could be used to explain the experimental results and unoccupied 5f electronic structure for simple localized actinide systems with n = 2/3, 2, 3, and 5, where n is the 5f occupancy. In this work, the thorium model will be extended to provide an understanding of the observed behavior and unoccupied 5f electronic structure in the uranium monochalcogenide systems of uranium sulfide and uranium telluride, in terms of weak 5f delocalization.

36 MATERIALS SCIENCE↗

Considerations in upconversion: A practical guide to sum-frequency generation spectrometer design and implementation

Here, in this tutorial review, we discuss how the choice of upconversion pulse shape in broadband vibrational sum-frequency generation (SFG) spectrometer design impacts the chemical or physical insights one can obtain from a set of measurements. A time-domain picture of a vibrational coherence being mapped by a second optical field is described and the implications of how this mapping, or upconversion process, takes place are given in the context of several popular and emerging approaches found in the literature. Emphasis is placed on broadband frequency-domain measurements, where the choice of upconversion pulse enhances or limits the information contained in the SFG spectrum. We conclude with an outline for a flexible approach to SFG upconversion using pulse-shaping methods and a simple guide to design and optimize the associated instrumentation.

47 OTHER INSTRUMENTATION↗