Spatial correlation and molecular properties in extended Hartree-Fock calculations.
Spatial correlation and molecular properties in extended Hartree-Fock calculations, deriving first and second order density matrices for ground state of H, Li and F
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Spatial correlation and molecular properties in extended Hartree-Fock calculations, deriving first and second order density matrices for ground state of H, Li and F
Conversion process and ESR in gamma-irradiated dihydrothymine noting reaction rate
Electronic, vibrational and rotational temperatures in laser-produced flames measured spectroscopically
Permafrost layer existence beneath lunar surface, noting possible detection techniques
Moleuclar band spectra of CN emission assuming Gaussian rotational line profile
Microwave spectra of 1-methylpentaborane /9/ noting vibration-rotation interactions, molecular structure and dipole moment
Lowest valence and Rydberg states assigned to ungerade singlet states in dipole allowed absorption spectrum of molecular nitrogen
Carbon dioxide electron impact energy loss spectrum and molecular orbit calculations, discussing fourth positive bands production in Mars upper atmosphere UV dayglow
The performance of an upconversion system is examined for observation of astronomical sources in the low to middle infrared spectral range. Theoretical values for the performance parameters of an upconversion system for astronomical observations are evaluated in view of the conversion efficiencies, spectral resolution, field of view, minimum detectable source brightness and source flux. Experimental results of blackbody measurements and molecular absorption spectrum measurements using a lithium niobate upconverter with an argon-ion laser as the pump are presented. Estimates of the expected optimum sensitivity of an upconversion device which may be built with the presently available components are given.
Absolute reflectivity reductions are presented for spectrophotometric observations of seven spatially-resolved regions on the disk of Saturn in the 3000-6000 A region. An asymmetry is found between northern and southern hemisphere data, in the equivalent width of the CH4, 5430-A band and in the continuum reflectivity. In addition, the spectra are found not to include the 4700 A reflectivity peak found by Bergstralh et al (1981), and to exhibit general agreement with the Podolack and Danielson (1977) model. The blue and visual spectral region continuum reflectivity of a planetary atmosphere provides constraints for determining aerosol particle single-scattering albedo and vertical distribution, which are in turn important to an understanding of planetary energy balance, atmospheric dynamics, and planetary molecular absorption spectrum interpretation.
The molecular rotational spectrum of ozone is quite rich in the mm-wave region from 50 to 300 GHz. An apparatus, which was developed primarily for detection and measurement of stratospheric ClO and other trace molecules, is found to be well suited also for the observation of ozone lines. The collecting antenna of the apparatus is a simple mm-waveguide feedhorn. The detector is a superheterodyne mixer using a special high frequency Schottky diode and a klystron local oscillator. The spectrometer is a 256 channel filter bank with 1 MHz resolution per channel. The apparatus is believed to be the first ground-based mm-wave instrument having the capability of obtaining data of sufficient quality to make use of the inversion technique. The ground based radio technique is most sensitive to changes in vertical distribution in the region above 25 km, a region which is difficult to sample by other techniques.
It is suggested that the Planck h = m(sub k)c Lambda(sub k) and the Boltzmann k = m(sub k)c nu(sub k)Constants have stochastic foundation. It is further suggested that a body of fluid at equilibrium is composed of a spectrum of molecular clusters (energy levels) the size of which are governed by the Maxwell-Boltzmann distribution function. Brownian motions are attributed to equilibrium between suspensions and molecular clusters. Atomic (molecular) transition between different size atomic- (molecular-) clusters (energy levels) is shown to result in emission/absorption of energy in accordance with Bohr's theory of atomic spectra. Physical space is identified as a tachyonic fluid that is Dirac's stochastic ether or de Broglie's hidden thermostat. Compressibility of physical space, in accordance with Planck's compressible ether, is shown to result in the Lorentz-Fitzgerald contraction, thus providing a causal explanation of relativistic effect in accordance with the perceptions of Poincare and Lorentz. The invariant Schrodinger equation is derived from the invariant Bernoulli equation for incompressible potential flow. Following Heisenberg a temporal uncertainty relation is introduced as Delta(nu(sub Beta)) Delta(Rho(sub Beta)) > = k.
Under a Small Business Innovation Research (SBIR) contract to Kennedy Space Center, EIC Laboratories invented a Raman Spectrograph with fiber optic sampling for space applications such as sensing hazardous fuel vapors and making on-board rapid analyses of chemicals and minerals. Raman spectroscopy is a laser-based measurement technique that provides through a unique vibrational spectrum a molecular 'fingerprint,' and can function in aqueous environments. EIC combined optical fiber technology with Raman methods to develop sensors that can be operated at a distance from the spectrographic analysis instruments and the laser excitation source. EIC refined and commercialized the technology to create the Fiber Optic Raman Spectrograph and the RamanProbe. Commercial applications range from process control to monitoring hazardous materials.
The topics covered include: 1) Replaceable Sensor System for Bioreactor Monitoring; 2) Unitary Shaft-Angle and Shaft-Speed Sensor Assemblies; 3) Arrays of Nano Tunnel Junctions as Infrared Image Sensors; 4) Catalytic-Metal/PdO(sub x)/SiC Schottky-Diode Gas Sensors; 5) Compact, Precise Inertial Rotation Sensors for Spacecraft; 6) Universal Controller for Spacecraft Mechanisms; 7) The Flostation - an Immersive Cyberspace System; 8) Algorithm for Aligning an Array of Receiving Radio Antennas; 9) Single-Chip T/R Module for 1.2 GHz; 10) Quantum Entanglement Molecular Absorption Spectrum Simulator; 11) FuzzObserver; 12) Internet Distribution of Spacecraft Telemetry Data; 13) Semi-Automated Identification of Rocks in Images; 14) Pattern-Recognition Algorithm for Locking Laser Frequency; 15) Designing Cure Cycles for Matrix/Fiber Composite Parts; 16) Controlling Herds of Cooperative Robots; 17) Modification of a Limbed Robot to Favor Climbing; 18) Vacuum-Assisted, Constant-Force Exercise Device; 19) Production of Tuber-Inducing Factor; 20) Quantum-Dot Laser for Wavelengths of 1.8 to 2.3 micron; 21) Tunable Filter Made From Three Coupled WGM Resonators; and 22) Dynamic Pupil Masking for Phasing Telescope Mirror Segments.
The Fabry-Perot interferometer is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating flow properties such as gas velocity and temperature. Rayleigh scattered light from a focused laser beam can be directly imaged through a solid Fabry-Perot etalon onto a CCD detector to provide the spectral content of the scattered light. The spatial resolution of the measurements is governed by the locations of interference fringes. The location of the fringes can be changed by altering the etalon?s physical characteristics, such as thickness and index of refraction. For a fused silica solid etalon the physical properties can be adjusted by changing the etalon temperature; hence changing the order of the interference pattern and the physical fringe locations. Controlling the temperature of the etalon can provide for a slow time-response spatial scanning method for this type of etalon system. A custom designed liquid crystal Fabry-Perot (LCFP) can provide for a fast time-response method of scanning the etalon system. Voltage applied to the liquid crystal interface sets the etalon?s properties allowing Rayleigh measurements to be acquired at varying spatial locations across the image of the laser beam over a very short time period. A standard fused silica etalon and a tunable LCFP etalon are characterized to select the system that is best suited for Rayleigh scattering measurements in subsonic and supersonic flow regimes. A frequency-stabilized laser is used to investigate the apparent frequency stability and temperature sensitivity of the etalon systems. Frequency stability and temperature sensitivity data of the fused silica and LCFP etalon systems are presented in this paper, along with measurements of the LCFP etalon?s tuning capabilities. Rayleigh scattering velocity measurements with both etalon systems are presented, in an effort to determine which etalon is better suited to provide optical flow measurements of velocity, temperature, and density.
Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous density, velocity, and temperature measurements. The Fabry-Perot interferometer or etalon is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating these flow properties. This paper investigates the use of a tunable liquid crystal (LC) Fabry-Perot etalon in Rayleigh scattering experiments at NASA Glenn Research Center. The LC etalon provides a robust interferometry system that can be tuned rapidly by adjusting the voltage applied to the liquid crystal interface. Tuning the interferometer is often necessary to control the physical locations of the concentric interference fringes when Rayleigh light is imaged through the LC etalon. The LC etalon diagnostic system was tested in a 1-cm diameter nozzle flow in two different scattering configurations to evaluate its usefulness for Rayleigh measurements compared to a traditional non-tunable fused silica Fabry-Perot etalon.
Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous velocity, density, and temperature measurements. The Fabry-Perot interferometer or etalon is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating these flow properties. This paper investigates the use of an acousto-optic frequency shifting device to improve measurement accuracy in Rayleigh scattering experiments at the NASA Glenn Research Center. The frequency shifting device is used as a means of shifting the incident or reference laser frequency by 1100 MHz to avoid overlap of the Rayleigh and reference signal peaks in the interference pattern used to obtain the velocity, density, and temperature measurements, and also to calibrate the free spectral range of the Fabry-Perot etalon. The measurement accuracy improvement is evaluated by comparison of Rayleigh scattering measurements acquired with and without shifting of the reference signal frequency in a 10 mm diameter subsonic nozzle flow.
Photosynthesis produces signs of life we can see from space: the absorbance spectrum of surface photosynthetic pigments and, with oxygenic photosynthesis, atmospheric oxygen. Since the first discovery of a planet in another solar system in 1989, there has been an explosion in the detection of exoplanets (over 1849 as of 7 November 2014) and we are getting ever closer to finding that Goldilocks planet that might harbour life. With telescope observations of these planets, oxygenic photosynthesis has been considered our most robust target 'biosignature' that would not appear on a lifeless planet. Since anoxygenic photosynthetic organisms do not produce unambiguously biogenic gases, there is interest in their pigments serving as spectral indicators of life. But will they look the same as on Earth, can we distinguish them from the abiotic, and what will dominate on another planet? Examples from Earth provide us with the potential to extrapolate some rules for photosynthesis to predict its signature on another planet, but there are yet things we must answer about life here to improve our confidence. In particular, given the combination of the available stellar spectrum and molecular constraints on photon energy use, can we predict the pigment spectral features that will dominate, which reductant will match, and what biogenic gases would result? We take clues from the diversity of anoxygenic photosynthetic metabolisms and three very recent examples of oxygenic photosynthesis utilizing other reaction centre (RC) chlorophylls in addition to chlorophyll a (Chl a).