Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modulation transfer function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A liquid crystal adaptive lens

Creation of an electronically controlled liquid crystal lens for use as a focusing mechanism in a multi-element lens system or as an adaptive optical element is analyzed. Varying the index of refraction is shown to be equivalent to the shaping of a solid refracting material. Basic characteristics of liquid crystals, essential for the creation of a lens, are reviewed. The required variation of index of refraction is provided by choosing appropriate electrode voltages. The configuration required for any incoming polarization is given and its theoretical performance in terms of modulation transfer function derived.

Kowel, S. T.↗

Intagliated phosphor screen image tube project

The production and evaluation of a magnetic focus image tube for astronomical photography that has an intagliated phosphor screen is described. The modulation transfer function of such a tube was measured by electronic means and by film tests, and the results compared with tubes of more conventional construction. The physical properties of the image tube and film combination, the analytical model of the optical interface, and the salient features of the intagliated screen tube are described. The results of electronic MTF tests of the intagliated image tube and of the densitometry of the tube and film test samples are presented. It is concluded that the intagliated screen is a help, but that the thickness of the photographic film is also important.

Hertzel, R. J.↗

The development and applications of charge-coupled devices for space astronomy

The developments in charge-coupled device technology over the past decade are reviewed, with emphasis on the relevance of these developments to astronomical applications. The characteristics and limitations of current commercial devices are described, and the future requirements on CCDs for space astronomy are summarized for the X-ray and near UV, optical, and infrared wavelength ranges. Emphasis is placed on the commonality of technological development which is called for, including the issues of quantum detection efficiency (photon entrance and depletion depth), charge transfer efficiency, modulation transfer function, output noise level, and array size. The system requirements on focal plane instrumentation for space astronomy are summarized, and shown to have much in common for the different wavelength bands. These requirements are discussed in terms of CCD mosaicing, cryogenic cooling, and electronics. The overlap in CCD developments in the defense, astronomical and commercial arenas is summarized.

Griffiths, R. E.↗

Precise Measurement of Effective Focal Length

Computerized instrument measures effective focal lengths to 0.01 percent accuracy. Laser interferometers measure mirror angle and stage coordinate y in instrument for accurate measurment of focal properties of optical systems. Operates under computer control to measure effective focal length, focal surface shape, modulation transfer function, and astigmatism.

Wise, T. D.↗

Low-Earth orbit satellite servicing economics

Servicing economics of low Earth orbit satellites were studied. The following topics are examined: the economic importance of the repair missions; comparison of mission cost as opposed to satellite modulation transfer functions over a 10 year period; the effect of satellite flight rate change due to changes in satellite failure rate; estimated satellite cost reduction with shuttle operation projects from the 1960's to the 1970's; design objectives of the multimission modular spacecraft; and the economic importance of the repair mission.

Davis, R. F.↗

TM report

Key spectral, radiometric, and geometric characteristics of the TM sensor are examined. Spectrally, band 5 is slightly wider than specified and its upper edge at 50% of miximum of 1784 nm includes some unintended overlap with water absorption bands. Thermal band 6 is half the expected width. Radiometrically, the TM has extreme linearity and stability in comparison with previous MSS photomultiplier systems. Forward and reverse scans on TM show some unexplained radiometric differences of up to four digital levels. Primary focal plane bands show a monotomic decrease in gain of about 5% in the five months since launch. The relative internal gains of bands 5 and 7 varied with a period of about 60 days and an amplitude of about 6%. Radiometric calibration must be applied before histogram equalization algorithms to preserve radiometric accuracy. Geometrically, channel 4 in band 2 has a smaller modulation transfer function than desired. There is apparent misregistration of .75 pixels along scan and 0.2 pixels across scan.

Barker, J. L.↗

MTF analysis of LANDSAT-4 Thematic Mapper

The spatial radiance distribution of a ground target must be known to a resolution at least four to five times greater than that of the system under test when measuring a satellite sensor's modulation transfer function. Calibration of the target requires either the use of man-made special purpose targets with known properties, e.g., a small reflective mirror or a dark-light linear pattern such as line or edge, or use of relatively high resolution underflight imagery to calibrate an arbitrary ground scene. Both approaches are to be used in addition a technique that utilizes an analytical model for the scene spatial frequency power spectrum is being investigated as an alternative to calibration of the scene.

Schowengerdt, R.↗

Different atmospheric effects in remote sensing of uniform and nonuniform surfaces

The atmospheric effect on the radiance of sunlight scattered from the earth-atmosphere system is greatly dependent on the surface reflectance pattern, the contrast between adjacent fields, and the optical properties of the atmosphere. In addition, the atmospheric effect is described by the range and magnitude of the adjacency effects, the atmospheric modulation transfer function, and the apparent spatial resolution of remotely sensed imagery. This paper discusses the atmospheric effect on classification of surface features and shows that surface nonuniformity can be used for developing procedures to remove the atmospheric effect from the satellite imagery.

Kaufman, Y. J.↗

LANDSAT-4 sensor performance

Preflight and in-orbit sensor and data measurements indicate that TM meets or exceeds most specifications. Measured spectral band edges meet instrument specifications in 12 out of 14 cases; there is ample dynamic range. The signal-to-noise ratio exceeds specifications, except for band 3, channel 4; and band 7 channel 7 is very noisy but still meets specifications. The modulation transfer function of channel 4, band 2, is smaller than specified. Registration errors between the primary focal plane (PFP) and the cold focal plane (CFP) are about 0.75 pixels along-scan and 0.2 pixels across scan. Forward and reverse scan discontinuities, are well within ground-processing capabilities to rectify. Instrument gain variability, up to 7% for band 5, requires use of the internal calibration (IC) system to assure radiometric accuracy. Preliminary applications evaluation of image contents indicates that TM provides much better definition of edges than MSS.

Barker, J. L.↗

An improved logarithmic amplifier circuit for PDS microdensitometers

A high speed logarithmic amplifier circuit for the Perkin-Elmer PDS microdensitometer is discussed. The circuit is designed around an Analog Devices 757p log-amp module. The amplifier produces undistorted profiles of rapidly changing, dense ( 4) images over the available range of scanning speeds. The circuit board was designed to replace directly the manufacturer supplied unit; neither electrical nor mechanical modifications of the basic PDS are required. The performance of the circuit is illustrated through its effects on the overall modulation transfer function of the instrument and by scans of a well exposed stellar image. Circuit diagrams and parts lists a mechanism for obtaining either circuit board layout art work or finished circuit boards are presented.

Anderson, C. M.↗

MTF Analysis of LANDSAT-4 Thematic Mapper

A research program to measure the LANDSAT 4 Thematic Mapper (TM) modulation transfer function (MTF) is described. Measurement of a satellite sensor's MTF requires the use of a calibrated ground target, i.e., the spatial radiance distribution of the target must be known to a resolution at least four to five times greater than that of the system under test. A small reflective mirror or a dark light linear pattern such as line or edge, and relatively high resolution underflight imagery are used to calibrate the target. A technique that utilizes an analytical model for the scene spatial frequency power spectrum will be investigated as an alternative to calibration of the scene. The test sites and analysis techniques are also described.

Schowengerdt, R.↗

Preliminary Evaluation of Thematic Mapper Image Data Quality

Thematic Mapper (TM) data from Mississippi County, Arkansas, and Webster County, Iowa, were examined for the purpose of evaluating the image data quality of the TM which was launched on board the LANDSAT-4 spacecraft. Preliminary clustering and principal component analysis indicates that the middle infrared and thermal infrared data of TM appear to add significant information over that of the near IR and visible bands of the multispectral scanner data. Moreover, the higher spatial resolution of TM appears to provide better definition of the edges and the within variability of agricultural fields. The geometric performance of TM data, without ground control correction, was found to exceed expectations. The modulation transfer function for the 1.65 m band was found to agree with prelaunch specifications when the effects of the GSFC cubic convolution and the atmosphere were removed. The band to band registration for the bands within the noncooled focal plane was found to be better than specified. However, the middle infrared and thermal infrared, which are on a separate cooled focal plane were found to be misregistered and were significantly worse than prelaunch specifications.

Macdonald, R. B.↗

Investigation of several aspects of LANDSAT 4/5 data quality

A second quadrant from the Sacramento, CA scene 44/33 acquired by LANDSAT-4 was tested for band to band resolution. Results show that all measured misregistrations are within 0.03 pixels for similar band pairs. Two LANDSAT-5 scenes (one from Corpus Christi, TX and the other from Huntsville, AL) were also tested for band to band resolution. All measured misregistrations in the Texas scene are less than 0.03 pixels. The across scan misregistration Alabama scene is -0.66 pixels and thus needs correction. A 512 x 512 pixel area of the Pacific Ocean was corrected for the pixel offsets. Modulation transfer function analysis of the San Mateo Bridge using data from the San Francisco scene was accomplished.

Wrigley, R. C.↗

An improved logarithmic amplifier circuit for PDS microdensitometers

A high-speed logarithmic-amplifier circuit for a PDS microdensitometer is discussed. The circuit is designed around a 757P log-amp module which replaces the FMI 531 'Negative Log/Anti-log' device of the original. The new amplifier is capable of producing undistorted profiles of rapidly changing, dense images over the available range of scanning speeds. The circuit board has been designed to directly replace the manufacturer supplied unit; neither electrical nor mechanical modifications of the basic PDS are required. The performance of the circuit is illustrated through its effects on the overall Modulation Transfer Function of the instrument and by scans of a well-exposed stellar image. Circuit diagrams and parts lists are presented.

Anderson, C. M.↗

Honeywell multispectral linear array (MLA) instrument design A system overview

In support of NASA's Experimental Land Observing System, a simple, reliable and relatively inexpensive multispectral linear array (MLA) instrument concept has been developed. The design satisfies requirements for multichannel radiometry and wide field imaging. A reflective off-axis anastigmat telescope is mounted in a highly strength-to-weight efficient truss structure, coupled to a solid beamsplitter assembly. Attention is given to the optical design of the MLA instrument, the telescope structure, the detector arrays, detector cooling, on-orbit calibration, signal processing electronics, the spacecraft interfaces, the modulation transfer function, the signal-to-noise ratio, radiometric accuracy, and spatial registration.

Eyring, D.↗

Landsat-4 sensor performance

Preflight and in-orbit sensor and data measurements indicate that TM meets or exceeds most specifications. Measured spectral band edges meet instrument specifications in 12 out of 14 cases; there is ample dynamic range. The signal-to-noise ratio exceeds specifications, except for band 3, channel 4; and band 7 channel 7 is very noisy but still meets specifications. The modulation transfer function of channel 4, band 2, is smaller than specified. Registration errors between the primary focal plane (PFP) and the cold focal plane (CFP) are about 0.75 pixels along-scan and 0.2 pixels across scan. Forward and reverse scan discontinuities are well within ground-processing capabilities to rectify. Instrument gain variability, up to 7 percent for band 5, requires use of the internal calibration (IC) system to assure radiometric accuracy. Preliminary applications evaluation of image contents indicates that TM provides much better definition of edges than MSS.

Barker, J. L.↗

Investigation of several aspects of LANDSAT 4/5 data quality

A technique under development uses a zoom transfer scope to register the photograph of the target with digitally enlarged photographic hardcopy of the TM data using a visual fit to the area surrounding the target. The first attempt using the Sacramento Scene (44/33) of February 1, 1983 indicated that relief displacement in the aerial photography would cause large errors. A second attempt is in progress using the aero-triangulated scene centers which have no relief displacement. Being calculated points, the scene centers have somewhat larger absolute errors in geolocation, approximately 3 meters instead of 1.5 meters. The average TM effective instantaneous field of view (EIFOV) calculated from modulation transfer functions (MTFs) is 52.7 m. This is smaller than the 55 and 65 m EIFOVs reported earlier using noisy MTFs but larger than the EIFOVs from the San Mateo Bridge analysis which ranged from 44.5 to 50.9 m and averaged 47.6 m for the same TM scene.

Wrigley, R. C.↗

Study of alternate optical and fine guidance sensor designs for the space infrared telescope facility (SIRTF)

A unique optical design was developed that compensates for the coma degraded images caused by field chopping in SIRTF. The conic constants of a Cassegrain telescope were altered to compensate for the coma induced by the secondary mirror tilt. The modulation transfer function is essentially independent of secondary mirror tilt, and diffraction limited image quality is maintained over a several arcminute field during chopping. With an untilted secondary mirror, the coma compensated (CC) design has a smaller field than the unchopped Ritchey-Chretien design; but use of relay optics, such as the inverted Cassegrain design developed for the fine guidance sensor (FGS), can increase the CC telescope's field size. A reactionless secondary mirror chopper mechanism that uses superconducting magnets was studied. The heart producing elements are confined to a reaction plate that is not directly viewed by the IR focal plane. A design was also developed for a low moment of inertia, reticulated HIP beryllium secondary mirror consistent with blank fabrication technology and optical finishing requirements.

Wissinger, A.↗