Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microgrid components”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

CRADA Final Report: Open Microgrid Platform

Current microgrid control technology is mostly proprietary, expensive, and inflexible. An open-source, vendor-neutral, publish-subscribe controller will significantly lower the barrier to entry for new technologies and market entrants: inverter, battery, and load control manufacturers; cloud and services providers; and energy aggregators. An OpenFMB controller can significantly reduce the acquisition, integration, and ongoing operating and maintenance costs and increase revenue opportunities for energy producers and consumers. It allows distributed energy resource (DER) owners to replace individual DER components as richer-function, lower-cost devices become available or to incorporate new forecast and optimization algorithms as they are developed. A standard, secure, full-function DER field controller will also provide a low-cost means for grid operators to effectively manage the variability and uncertainty of solar photovoltaics (PV). Under the terms of this CRADA, ORNL has worked with Open Energy Solutions (OES) to advance the transition of ORNL’s existing open-source microgrid controller into a platform geared toward mainstream implementation. Using a more prevalent and memory-safe programming language, Rust, OES has converted ORNL’s current generation on-grid optimization into an application more suitable for industry use. The results of the ported optimization were analyzed by inputting the same arguments in both the current-generation and next-generation optimizers and verifying that the results were equivalent.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A New Distributed Model-Free Control Strategy to Diminish Distribution System Voltage Violations

This paper proposes a new distributed model-free control (MFC) strategy for dynamic voltage control to diminish distribution systems' voltage violations. The objective is to maintain all critical load bus voltages within the acceptable ANSI Range A (+/- 5% of nominal). The distributed MFC strategy, which only requires local voltage measurements from designated load buses, controls online the reactive power generation of available synchronous generator (SG)-based and photovoltaic (PV)-based distributed generators (DGs). The distributed MFC strategy is computationally efficient and does not require modelling of the different system components and disturbances. Time-domain dynamic simulations are conducted for the 21-bus test distribution system fed by multiple DGs to verify the performance of the proposed MFC strategy, and the results are compared against the conventional model-based microgrid voltage stabilizer (MGVS) control strategy. The simulation results show that the distributed MFC strategy provides minimal voltage violations and achieves the dynamic voltage stability of the system under diverse disturbances.

Hatipoglu, Kenan↗

NASA Lunar Surface Operations & Power Grid

The National Aeronautics and Space Administration (NASA) Artemis Program is developing, testing, and demonstrating new capabilities and technologies required to support a sustainable human presence on the lunar surface and a longer-term vision of sending astronauts to Mars. Artemis lunar surface operations will begin with robotically exploring the lunar south polar regions for locations suitable for harvesting lunar surface resources. Over time activities on the lunar surface will expand beyond robotic operations to human lunar surface operations with the delivery of a lunar habitat and in-situ resource utilization (ISRU) assets increasing the need for highly reliable and available electrical power. As operations move beyond the Artemis technology demonstrations and exploration activities towards full commercial lunar surface activities, the ability to expand the original envisioned Artemis power system and repurpose power system components to support commercial activities will be crucial. One technology that will be necessary to support commercial lunar operations is a power grid. A lunar surface power grid would offer the ability to integrate various power sources to maximize power availability, including fission surface power (nuclear), solar arrays, batteries, and regenerative fuel cells. Newly designed terrestrial microgrids are flexible and can be designed to allow for islanded operation, where power is utilized near the loads to minimize power distribution losses or in a power sharing mode where power is transmitted longer distances. This capability is crucial during failures where overall power availability is reduced, and load demand exceeds generation/storage capability. These terrestrial microgrids will also allow for the power system to grow and evolve over time, meeting the need to expand beyond initial lunar surface activities. This presentation will discuss the NASA Artemis plans, potential power system architectures, and power distribution options that will enable growth from initial technology demonstrations towards a lunar economy with a lunar surface power grid that offers many of the advantages of terrestrial microgrids.

Microgrids↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Traveling Wave Signatures in Medium-Voltage Distribution Systems for Fault Detection and Location

Protection systems are a critical feature for the proper operation of a power grid. Protection systems should be able to quickly detect, identify, locate, and isolate the faults within a time frame that prevents damage to grid components and reduces customer outages. As more inverter-based photovoltaics (PV) are integrated into the grid, phasor domain based protection schemes become more inaccurate due to low levels of fault current from inverters or respond too slowly to accurately identify fault conditions. This points to the need to identify and develop novel protection approaches for distribution systems with high penetration of inverter based PV. The main objective of the project is to develop new time domain-based protection schemes to enable more accurate and faster detection, identification and location of faults in distribution systems and/or microgrids with high penetration of inverter-based PV. Our approach aims to exploit the traveling waves that are generated during a fault or other disturbances in the grid.

14 SOLAR ENERGY↗

Quantitative Evaluation of Reliability Improvement: Case Study on a Self-healing Distribution System

In this work, we develop a methodology and tool to quantitatively evaluate the reliability of a self-healing system that considers practical distribution system features such as the distributed energy resources, microgrids, and service restoration strategies. Also, this paper addresses various practical issues when being applied to an actual Duke Energy distribution system, including the design of feasible and practical service restoration strategies that are used to identify the customer interruptions after a fault, and the incorporation of the utility’s historical reliability indices that are used to calibrate the failure rate and repair time of distribution system components such as overhead lines and underground cables. This case study demonstrates the effectiveness of the proposed method.

Dong, Jiaojiao↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Quantitative Evaluation of Reliability Improvement: Case Study on a Self-healing Distribution System

In this work, we develop a methodology and tool to quantitatively evaluate the reliability of a self-healing system that considers practical distribution system features such as the distributed energy resources, microgrids, and service restoration strategies. Also, this paper addresses various practical issues when being applied to an actual Duke Energy distribution system, including the design of feasible and practical service restoration strategies that are used to identify the customer interruptions after a fault, and the incorporation of the utility's historical reliability indices that are used to calibrate the failure rate and repair time of distribution system components such as overhead lines and underground cables. This case study demonstrates the effectiveness of the proposed method.

Dong, Jiaojiao↗

Review of Graphite Properties Relevant to Micro-Reactor Design

Microreactors are advanced reactors that are designed to be small, scalable, and portable with up to 20 MW power. These reactors could operate independently, or as part of a microgrid, without need of a frequent refueling. Micro-reactors are designed to be deployable to provide electric power in remote locations, therefore providing greater flexibility. Several micro-reactors are under development in the US. These reactors are based on advanced gas-cooled or heat-pipe concepts. While Graphite can be found in various applications, some high-temperature reactors plan to employ Graphite in their core components due to its role as a moderator and its ability to maintain its structural integrity when subjected to elevated temperatures and high neutron fluence. Although there is significant experience with use of Graphite in nuclear applications, there are still unknowns that should be addressed. Graphite properties depend on the graphite type and affected by the fabrication procedures. Material properties are functions of the temperature and irradiation dose. The fundamental properties also affected by the oxidation environment. Therefore, in-depth understanding of graphite properties, including the effect of irradiation, oxidation and other influencing parameters are required to evaluate the design accurately. This draft aims to provide a comprehensive review of material properties for Graphite relevant to micro reactor design. For this work, two distinct grades of graphite were considered, namely IG-110 and Mersen-2114. Physical, thermal, and mechanical properties for these grades were comparatively evaluated. The properties that are discussed in this draft aim to serve as a basis for design and safety analysis.

42 ENGINEERING↗

Advanced Distributed Wind Turbine Controls Series: Part 2-Wind Energy in Isolated Grids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In an isolated grid, wind turbines are typically deployed to provide energy to maximize energy production, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, advanced wind turbine controls that can be employed to support higher contributions of wind in isolated grids, and to demonstrate ways that wind can play a role in supporting stability of an isolated grid. This isolated grid used in these desktop simulations is comprised of a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a simulated diesel generator (2 MW) and various types of loads (critical, dynamic). We developed a model of the subsystems in MATLAB/Simulink and validated them with available data from real-world components on NREL's Flatirons Campus. These validated models are then configured for various case studies. We compare the output of the desktop simulation with a baseline case with the diesel generator. Active and reactive power control of the wind turbine can help improve frequency and voltage responses in the isolated grid, respectively. By utilizing a small integrated battery energy storage system in the DC-link of the wind turbine, we also demonstrate that wind turbines can help blackstart a critical load comparable to its rated power and support other renewables (e.g. solar PV) come online and pick up an additional load. This report illustrates some of these reliability and resilience services a wind turbine can provide in an isolated grid.

17 WIND ENERGY↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis: Preprint

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline- based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive- sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

grid following inverter↗

Best Practices for Resilience in Smart Grid-Interactive Efficient Buildings

The Federal Energy Management Program (FEMP) supports federal agencies' energy decisions with information and guidance on design, funding, and operations to ensure federal buildings are efficient and resilient. The modernization of building infrastructure and the evolution of buildings to support decarbonization involves complex implementation of multiple components across several systems. This includes energy-efficient equipment, on-site energy generation and storage systems, and control systems. These systems have operational modes that can operate more efficiently if they are able to behave responsively to the conditions of the electrical grid. These grid-interactive efficient buildings (GEB) allow facilities to manage power demand according to operational constraints and market signals issued by grid operators. With proper design and planning, these same capabilities have the potential to enable building and facility resilience - coordinating with microgrids, maintaining power on critical circuits to sustain essential operations, and monitoring building health and safety status during an outage. By managing the load of buildings, GEBs can also reduce the cost of backup generation and make better use of renewable power sources on site. This document outlines some of the processes and considerations to guide the design and operation of GEBs in ways that promote facility resilience.

building decarbonization↗

Hierarchical semi-Markov models with duration-aware dynamics for activity sequences

Residential electricity demand at granular scales is driven by what people do and for how long. Accurately forecasting this demand for applications like microgrid management and demand response therefore requires generative models for activities that can produce realistic daily activity sequences, capturing both the timing and duration of human behavior. This paper develops a generative model of human activity sequences using nationally representative time-use diaries at a 10-min resolution. We use this model to quantify which demographic factors are most critical for improving predictive performance. We propose a hierarchical semi-Markov framework that addresses two key modeling challenges. First, a time-inhomogeneous Markov router learns the patterns of “which activity comes next.” Second, a semi-Markov hazard component explicitly models activity durations, capturing “how long” activities realistically last. To ensure statistical stability when data are sparse, the model pools information across related demographic groups and time blocks. The entire framework is trained and evaluated using survey design weights to ensure our findings are representative of the U.S. population. On a held-out test set, we demonstrate that explicitly modeling durations with the hazard component provides a substantial and statistically significant improvement over purely Markovian models. Furthermore, our analysis reveals a clear hierarchy of demographic factors: Sex, Day-Type, and Household Size provide the largest predictive gains, while Region and Season, though important for energy calculations, contribute little to predicting the activity sequence itself. The result is an interpretable and robust generator of synthetic activity traces, providing a high-fidelity foundation for downstream energy systems modeling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Optimal Power Control Strategy for Grid-Following Inverters in a Synchronous Frame

This work proposes a power control strategy based on the linear quadratic regulator with optimal reference tracking (LQR-ORT) for a three-phase inverter-based generator (IBG) using an LCL filter. The use of an LQR-ORT controller increases robustness margins and reduces the quadratic value of the power error and control inputs during transient response. A model in a synchronous reference frame that integrates power sharing and voltage–current (V–I) dynamics is also proposed. This model allows for analyzing closed-loop eigenvalue location and robustness margins. The proposed controller was compared against a classical droop approach using proportional-resonant controllers for the inner loops. Mathematical analysis and hardware-in-the-loop (HIL) experiments under variations in the LCL filter components demonstrate fulfillment of robustness and performance bounds of the LQR-ORT controller. Experimental results demonstrate accuracy of the proposed model and the effectiveness of the LQR-ORT controller in improving transient response, robustness, and power decoupling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Defensive Islanding to Enhance the Resilience of Distribution Systems Against Cyber-Induced Failures

The extensive integration of communication, computation, and control technologies into cyber-physical power systems (CPPSs) has increased the vulnerabilities of CPPSs to cyberattacks. This calls for developing solutions that assess and reduce the impacts of cyber-induced failures on CPPSs. This paper proposes a defensive islanding strategy to isolate impacted parts of the CPPS and form self-sufficient islanded grids with an objective of minimum load curtailment. The defensive islanding aims to split a power system into smaller grids to improve its resilience against a potential extreme event. A clustering approach that leverages the hierarchical spectral clustering method is utilized for the optimal defensive islanding. The proposed approach captures the fragility behavior and loading conditions of power system components due to cyber-induced failures. A graphical-based coupling framework is used to map the impacts of cyber failures into operation of power system components. The proposed method is demonstrated on a modified 33-node distribution feeder system integrated with distributed energy resources. The amount of load curtailment and radiality constraints have been used to evaluate the performance of the proposed clustering strategies. The results show the capability of the proposed algorithm to create islands considering the cyber-induced failures for enhanced resilience.

cyber-induced failures↗

Recursive Blind Forecasting of Photovoltaic Generation and Consumer Load for Microgrids

Existing forecasting frameworks that predict time-series photovoltaic (PV) generation and consumer load for micro-grids' operation and control assume near-continuous availability of real-time predictors from the field. The incoming data are used to periodically re-train the models and update forecast snapshots over a moving horizon window. However, such frameworks are not resilient to disruptions in data availability caused by losses in communications between the field sensors and data loggers. This paper bridges the shortcoming by leveraging a previously proposed forecasting framework that is resilient to abrupt changes in data quality caused by communication losses. Assuming no availability of real-time field system data, which is typical in extreme weather events such as hurricanes, the framework uses lightweight recursive time-series models to independently forecast solar irradiance, ambient temperature, PV power, and consumer load for three horizon windows: 24 hours, 12 hours, and 1 hour. Four types of ensemble-based regression trees-simple gradient boosted trees (GBR), GBR with an adaptive component (A-GBR), random forests (RF), and extra trees (ExTR)-are leveraged and their performances are compared against a simple historical weekly mean. Numerical results show that A-GBR performs better on average by 32% for 24-hour horizon and 39% for 12-hour horizon, whereas ExTR outdoes the other models on average by 10% for 1-hour horizon.

Sundararajan, Aditya↗

CIE Analysis Process for Engineered Systems

"CIE Analysis Process for Engineered Systems" outlines a comprehensive methodology for integrating Cyber-Informed Engineering (CIE) principles into both new and existing engineered systems. Sponsored by the U.S. Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (DOE CESER), the process aims to achieve cyber-informed decisions by producing functional security requirements for new systems and retrofitting existing systems to mitigate digital risks. The document details a step-by-step approach, including mission and function definition, digital asset awareness, consequence analysis, and mitigation analysis. It emphasizes the importance of documenting mechanical, electrical, programmable, and network components to protect system functions and provides examples and considerations for each step. The ultimate goal is to ensure that engineered systems remain resilient against cyber threats, maintaining safety, performance, and reliability.

42 - ENGINEERING↗

High-Temperature Latent Heat Storage System using Transportable Heat Pipes for Versatile Integration with Emerging Microreactors

With the growing interest in the development of micro nuclear reactors and their application to microgrid, high-temperature thermal energy storage (TES) has also been receiving great attention as a technology to reinforce the energy utilization and profitability of this class of reactors. Given the importance and research needs of the TES technology, a research project is underway at Idaho National Laboratory (INL) to develop high-temperature TES that can be easily interfaced with emerging micro nuclear reactors. Currently under development is the Heat pipe-Integrated Thermal Battery (HITB), a novel latent heat storage design that enables flexible and robust integration with any design of currently considered micro nuclear reactors. The development of detailed design based on the proposed TES concept, HITB, requires not only development and validation of modeling and simulation capabilities, but also research that spans thermal performance analysis, component- and system-scale design optimization, and experimental demonstrations including high-temperature feasibility testing. The current research efforts (and plans) are divided into the following four areas: (i) Thermal and structural modeling and analysis at both system- and component-scales for evaluating performance and conducting design optimization, (ii) Small-scale experimental demonstrations for the key components of the proposed HITB design, (iii) Modelica-based dynamic model development for developing a control strategy under dynamic operation within integrated energy systems configuration, (iv) Integrated experimental testing and demonstration. This paper introduces the overall research efforts that have been and are being conducted to develop and demonstrate the novel design of the high-temperature latent heat storage device, HITB. The key design features, ongoing research efforts including the development of modeling and simulation capabilities, small-scale demonstrations of the HITB’s key functionalities prior to scaled-up experimental demonstration, are discussed. Then, this paper concludes with a remark on the future research plans for this project.

25 ENERGY STORAGE↗