Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microfluidic flow cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Are those bugs reflective? Non-destructive biofilm imaging with white light interferometry

White light interferometry (WLI) is not typically used to image bacterial biofilms that are immersed in water because there is insufficient refractive index contrast to induce reflection from the biofilm’s interface. The soft structure and water-like bulk properties of hydrated biofilms make them difficult to characterize in situ by any means, especially in a non-destructive manner. Here we describe a new method for measuring and monitoring the thickness and topology of live biofilms using a WLI microscope. A microfluidic system was used to create a reflective interface on the surface of biofilms. Live biofilm samples were monitored non-destructively over time. The method enables surface metrology measurements (roughness, surface area) and a novel approach to measuring thickness of the thin hydrated biofilms. Increase in surface roughness preceded observable increase in biofilm thickness, indicating that this measure may be used to predict future development of biofilms. We have also developed a flow cell that enables WLI biofilm imaging in a dynamic environment. We have used this flow cell to observe changes in biofilm structure in response to changes in environmental conditions - flow velocity, availability of nutrients, and presence of biocides.

bacteria↗

MicroRaman measurements for nuclear fuel reprocessing applications

Treatment and reuse of used nuclear fuel is a key component in closing the nuclear fuel cycle. Solvent extraction reprocessing methods that have been developed contain various steps tailored to the separation of specific radionuclides, which are highly dependent upon solution properties. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. Our group has been investigating the use of optical spectroscopy for the on-line monitoring of actinides, lanthanides, and acid strength within fuel reprocessing streams. This paper will focus on the development and application of a new MicroRaman probe for on-line real-time monitoring of the U(VI)/nitrate ion/nitric acid in solutions relevant to used nuclear fuel reprocessing. Previous research has successfully demonstrated the applicability on the macroscopic scale, using sample probes requiring larger solution volumes. In an effort to minimize waste and reduce dose to personnel, we have modified this technique to allow measurement at the microfluidic scale using a Raman microprobe. Under the current sampling environment, Raman samples typically require upwards of 10 mL and larger. Using the new sampling system, we can sample volumes at 10 μL or less, which is a scale reduction of over 1,000 fold in sample size. Finally, this paper will summarize our current work in this area including: comparisons between the macroscopic and microscopic probes for detection limits, optimized channel focusing, and application in a flow cell with varying levels of HNO 3 , and UO 2 (NO 3 ) 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-membrane micro fuel cell

An in-membrane micro fuel cell comprises an electrically-insulating membrane that is permissive to the flow of cations, such as protons, and a pair of electrodes deposited on channels formed in the membrane. The channels are arranged as conduits for fluids, and define a membrane ridge between the channels. The electrodes are porous and include catalysts for promoting the liberation of a proton and an electron from a chemical species and/or or the recombination of a proton and an electron with a chemical specie. The fuel cell may be provided a biosensor, an electrochemical sensor, a microfluidic device, or other microscale devices fabricated in the fuel cell membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lattice Boltzmann simulation of asymmetric flow in nematic liquid crystals with finite anchoring

Liquid crystals (LCs) display many of the flow characteristics of liquids but exhibit long range orientational order. In the nematic phase, the coupling of structure and flow leads to complex hydrodynamic effects that remain to be fully elucidated. Here, we consider the hydrodynamics of a nematic LC in a hybrid cell, where opposite walls have conflicting anchoring boundary conditions, and we employ a 3D lattice Boltzmann method to simulate the time-dependent flow patterns that can arise. Due to the symmetry breaking of the director field within the hybrid cell, we observe that at low to moderate shear rates, the volumetric flow rate under Couette and Poiseuille flows is different for opposite flow directions. At high shear rates, the director field may undergo a topological transition which leads to symmetric flows. Here, by applying an oscillatory pressure gradient to the channel, a net volumetric flow rate is found to depend on the magnitude and frequency of the oscillation, as well as the anchoring strength. Taken together, our findings suggest several intriguing new applications for LCs in microfluidic devices.

36 MATERIALS SCIENCE↗

PREPARATION OF CLAY-COATED GLASS SURFACES FOR MICROFLUIDICS-BASED STUDY ON CLAY-FLUID INTERACTIONS

Unique characteristics of clay, even though make any clay abundant shales a good source of adsorbed gas, make them equally difficult to produce. The clay-water interaction can cause significant swelling and fines migration in the shale formation, both of which can significantly impair the overall hydrocarbon recovery from shale. Geomaterial micromodels, developed by functionalizing traditional glass or PDMS surface with geomaterials (e.g., calcite, quartz, clay) can represent the physico-chemical properties of the natural porous media and have been used during the last few years to understand and evaluate the solid-fluid physicochemical interactions. This study focuses on developing a clay-coated geomaterial surface and investigates the effect of base fluid's salinity on clay adsorption to the glass surface. Glass capillary tubes and straight channel borosilicate glass micromodels are coated with Illite clay minerals to represent the pore-scale clay chemistry of Caney Shale, a Mississippian unconventional play in Southern Oklahoma, USA. 10 wt.% of Illite clay slurries made with brines of four different salinities are used to coat the glass-capillary tubes to understand the effect of salinity in clay adsorption on the glass surface and overall coating quality. To achieve a stable coating and evaluate the impact of heat treatment on coating's stability, straight channel glass flow cells coated with Illite clay are heat-treated at low (25 °C) and high temperature (125 °C). Dynamic flooding tests were carried out with brines on the coated surface to evaluate the stability of the coating. The experiments' outcome indicated a strong relationship between the brine's salinity and the adsorption of clay particles on the glass surface. An increase in brine concentration resulted in improved adsorption of clay particles on the glass surface. Experiments involving heat treating the glass surface following the coating demonstrated significant improvement in the stability of the coating.

02 PETROLEUM↗

Single microbe trap and release in sub-microfluidics

Lab-on-a-chip systems have substantially impacted the way life-sciences are explored; life on earth, however, comprises mostly of microbes, which due to their sub-micron dimensions and high mobility are more challenging to dynamically manipulate on-a-chip. To address this challenge, we developed a high resolution microfluidic system (submicrofluidics) fabricated by direct electron beam lithography that is capable of trapping single microbes and releasing them upon demand. The fabrication method enabled the integration of sub-micron indentations (400 nm) with millimetre-scale fluidic channels rapidly in a single processing step. The larger channels deliver the cell suspension and reagents, while the sub-micron indentations immobilize the cells by locally increasing the hydrodynamic resistance. By volume exclusion, single cell trapping was possible in this system without any surface treatment. By increasing the flow rate, the microbes overcome the trap barrier and pass through the narrow indentation without undergoing lysis with kinetics that depend on their size. The fabrication method and its performance are described, along with microbial characterisations using E. coli.

59 BASIC BIOLOGICAL SCIENCES↗

Separation of Yeast Cells from MS2 Viruses Using Acoustic Radiation Force

We report a rapid and robust separation of Saccharomyces cerevisiae and MS2 bacteriophage using acoustic focusing in a microfluidic device. A piezoelectric transducer (PZT) generates acoustic standing waves in the microchannel. These standing waves induce acoustic radiation force fields that direct microparticles towards the nodes (i.e., pressure minima) or the anti-nodes (i.e., pressure maxima) of the standing waves depending on the relative compressidensity between the particle and the suspending liquid.[1] For particles larger than 2 {micro}m, the transverse velocities generated by these force fields enable continuous, high throughput separation. Extensive work in the last decade [2-4] has demonstrated acoustic focusing for manipulating microparticles or biological samples in microfluidic devices. This prior work has primarily focused on experimental realization of acoustic focusing without modeling or with limited one-dimensional modeling estimates. We recently developed a finite element modeling tool to predict the two-dimensional acoustic radiation force field perpendicular to the flow direction in microfluidic devices.[1] Here we compare results from this model with experimental parametric studies including variations of the PZT driving frequencies and voltages as well as various particle sizes and compressidensities. These experimental parametric studies also provide insight into the development of an adjustable 'virtual' pore-size filter as well as optimal operating conditions for various microparticle sizes. Figure 1 shows a typical experimental acoustic focusing result for microparticles (diameter = 2.0 {micro}m) in a 500 {micro}m wide by 200 {micro}m deep microchannel. In this case, the PZT driving frequency and voltage are, respectively, 1.459 MHz and 6.6 V. The microparticles tightly focus (full width half maximum (FWHM) {approx}30 {micro}m) less than 30 s after the initiation of the acoustic field. We simulated the same geometry and operating conditions for comparison. The surface plot in Figure 2 illustrates the two-dimensional pressure field orthogonal to the flow direction (x-direction) from the simulation. The superimposed vector plot shows the acoustic radiation force in this plane. The dark regions and the light regions respectively represent the nodes and anti-nodes of the acoustic pressure field. The corresponding force field predicts acoustic focusing at the center of the microchannel, which is confirmed by the experimental results shown in Figure 1. We demonstrated the separation of Saccharomyces cerevisiae (typical cell size of 4-6 {micro}m depending on the cell growth stage, measured using a Coulter counter) and MS2 bacteriophage (typical diameter {approx}30 nm [5]) using acoustic focusing (Figure 3). A mixture of S. cerevisiae and MS2 labeled with Ribogreen was prepared and injected into one inlet of the microchip (i.e., half of the microchannel was filled with the sample). We varied driving voltages from 1.96 to 4.76 V, while fixing the driving frequency at 1.459 MHz and flow rate at 20 {micro}l/min. The acoustic radiation force did not affect the MS2 viruses, and their concentration profile remained unchanged. Increased driving voltages enhanced the acoustic focusing of the yeast cells thereby achieving good separation. We are able to achieve yields of > 80% and sample purities of > 90% in this continuous-flow sample preparation device.

42 ENGINEERING↗

Harnessing surface-bound enzymatic reactions to organize microcapsules in solution

By developing new computational models, we examine how enzymatic reactions on an underlying surface can be harnessed to direct the motion and organization of reagent-laden microcapsules in a fluid-filled microchannel. In the presence of appropriate reagents, surface-bound enzymes can act as pumps, which drive large-scale fluid flows. When the reagents diffuse through the capsules’ porous shells, they can react with enzymatic sites on the bottom surface. The ensuing reaction generates fluid density variations, which result in fluid flows. These flows carry the suspended microcapsules and drive them to aggregate into “colonies” on and near the enzyme-covered sites. This aggregation continues until the reagent has been depleted and the convection stops. Here, we show that the shape of the assembled colonies can be tailored by patterning the distribution of enzymes on the surface. This fundamental physicochemical mechanism could have played a role in the self-organization of early biological cells (protocells) and can be used to regulate the autonomous motion and targeted delivery of microcarriers in microfluidic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preparation of illite coated geomaterial microfluidic surfaces: Effect of salinity and heat treatment

Unique characteristics of clay (e.g., high surface area, deficiency in positive charges) make any clay abundant shales a good source of adsorbed gas. However, the presence of clay in porous media can also affect shale rock's producibility. The clay-water interaction can cause significant swelling and fines migration in the formation and impair the overall hydrocarbon recovery from shale. Geomaterial micromodels, developed by functionalizing traditional glass or PDMS surfaces with geomaterials (e.g., calcite, Quartz, clay), can represent the physicochemical properties of the natural porous media and have been used during the last few years to understand and evaluate the solid-fluid physicochemical interactions. Here, this study focuses on developing a clay-coated geomaterial surface and investigates the effect of base fluid's salinity on clay adsorption to the glass surface. Glass capillary tubes and straight channel borosilicate glass micromodels are coated with Illite clay to represent the pore-scale clay chemistry of Caney Shale, a Mississippian unconventional play in Southern Oklahoma, USA. 10 wt% of Illite clay slurries made with brines of four different salinities are used to coat the glass-capillary tubes to understand the effect of salinity in clay adsorption on the glass surface and overall coating quality. To achieve a stable coating and evaluate the impact of heat treatment on coating's stability, straight channel glass flow cells coated with Illite clay are heat-treated at low (25 °C) and high temperature (125 °C), and the results are compared with an untreated coated surface. Flooding tests were carried out with brines of different salinities on the coated surface to evaluate the stability of the coating. The experimental results indicated a strong relationship between the brine's salinity and the adsorption of clay particles on the glass surface. An increase in brine concentration resulted in improved adsorption of clay particles on the glass surface. Experiments involving heat treating the glass surface following the coating demonstrated significant improvement in the stability of the coating.

02 PETROLEUM↗

On-demand generation of aqueous two-phase microdroplets with reversible phase transitions

Aqueous two-phase systems contained entirely within microdroplets enable a bottom-up approach to mimicking the dynamic microcompartmentation of biomaterial that naturally occurs within the cytoplasm of cells. Here, we demonstrate the on-demand generation of femtolitre aqueous two-phase droplets within a microfluidic oil channel. Gated pressure pulses were used to generate individual, stationary two-phase microdroplets with a well-defined time zero for carrying out controlled and sequential phase transformations over time. Reversible phase transitions between single-phase, two-phase, and core-shell microgel states were obtained via evaporation-induced dehydration and on-demand water rehydration. In contrast to other microfluidic aqueous two-phase droplets, which require continuous flows and high-frequency droplet formation, our system enables the controlled isolation and reversible transformation of a single microdroplet and is expected to be useful for future studies in dynamic microcompartmentation and affinity partitioning.

Boreyko, Jonathan B↗

A widefield fluorescence microscope with a linear image sensor for image cytometry of biospecimens: Considerations for image quality optimization

Linear image sensors have been widely used in numerous research and industry applications to provide continuous imaging of moving objects. Here, we present a widefield fluorescence microscope with a linear image sensor used to image translating objects for image cytometry. First, a calibration curve was characterized for a custom microfluidic chamber over a span of volumetric pump rates. Image data were also acquired using 15 μm fluorescent polystyrene spheres on a slide with a motorized translation stage in order to match linear translation speed with line exposure periods to preserve the image aspect ratio. Aspect ratios were then calculated after imaging to ensure quality control of image data. Fluorescent beads were imaged in suspension flowing through the microfluidics chamber being pumped by a mechanical syringe pump at 16 μl min{sup −1} with a line exposure period of 150 μs. The line period was selected to acquire images of fluorescent beads with a 40 dB signal-to-background ratio. A motorized translation stage was then used to transport conventional glass slides of stained cellular biospecimens. Whole blood collected from healthy volunteers was stained with 0.02% (w/v) proflavine hemisulfate was imaged to highlight leukocyte morphology with a 1.56 mm × 1.28 mm field of view (1540 ms total acquisition time). Oral squamous cells were also collected from healthy volunteers and stained with 0.01% (w/v) proflavine hemisulfate to demonstrate quantifiable subcellular features and an average nuclear to cytoplasmic ratio of 0.03 (n = 75), with a resolution of 0.31 μm pixels{sup −1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A transmissive concentrator photovoltaic module with cells directly cooled by silicone oil for solar cogeneration systems

Hybrid concentrator photovoltaic-thermal systems can cogenerate electricity and heat by beam-splitting incoming concentrated light onto photovoltaic cells and a thermal receiver to increase total conversion efficiency and potentially reduce system cost. To demonstrate this, we have designed and prototyped a transmissive spectrum-splitting concentrator photovoltaic module that maximizes solar energy conversion by utilizing the entire solar spectrum. Visible light is collected using infrared-transmissive triple-junction photovoltaic cells to achieve an in-band module efficiency of 43.3% for light of wavelength λ < 873 nm, while 44.2% of out-of-band light with λ > 873 nm is transmitted through for collection by a thermal receiver. During testing on a dual-axis tracked parabolic concentrator dish at up to 166 suns, cell temperatures were maintained at 119 °C or below via a novel active cooling method. This cooling system strictly flows silicone oil directly across both sides of the cells, without inhibiting optical transmission, as verified through experimentation and simulation. The module was validated outdoors for 572 sun·hrs, and achieved a maximum thermal receiver temperature of 180 °C. 86.1% of incident solar power is collected at 166 suns average concentration collectively among the electrical, cooling, and thermal receiver subsystems. The remaining 13.9% is lost to mirror reflectivity, dish shadowing, receiver reflection, and thermal losses. The ability to directly cool the cells with an inert silicone oil offers the potential for reduced system cost relative to previous transmissive hybrid concentrator photovoltaic-thermal systems, including microfluidic-cooled designs. This solar cogeneration capability is valuable in a wide range of commercial and industrial applications.

14 SOLAR ENERGY↗

Hybridization and Selective Release of DNA Microarrays

DNA microarrays contain sequence specific probes arrayed in distinct spots numbering from 10,000 to over 1,000,000, depending on the platform. This tremendous degree of multiplexing gives microarrays great potential for environmental background sampling, broad-spectrum clinical monitoring, and continuous biological threat detection. In practice, their use in these applications is not common due to limited information content, long processing times, and high cost. The work focused on characterizing the phenomena of microarray hybridization and selective release that will allow these limitations to be addressed. This will revolutionize the ways that microarrays can be used for LLNL's Global Security missions. The goals of this project were two-fold: automated faster hybridizations and selective release of hybridized features. The first study area involves hybridization kinetics and mass-transfer effects. the standard hybridization protocol uses an overnight incubation to achieve the best possible signal for any sample type, as well as for convenience in manual processing. There is potential to significantly shorten this time based on better understanding and control of the rate-limiting processes and knowledge of the progress of the hybridization. In the hybridization work, a custom microarray flow cell was used to manipulate the chemical and thermal environment of the array and autonomously image the changes over time during hybridization. The second study area is selective release. Microarrays easily generate hybridization patterns and signatures, but there is still an unmet need for methodologies enabling rapid and selective analysis of these patterns and signatures. Detailed analysis of individual spots by subsequent sequencing could potentially yield significant information for rapidly mutating and emerging (or deliberately engineered) pathogens. In the selective release work, optical energy deposition with coherent light quickly provides the thermal energy to single spots to release hybridized DNA. This work leverages LLNL expertise in optics, microfluids, and bioinformatics.

47 OTHER INSTRUMENTATION↗

High-precision chemical quantum sensing in flowing monodisperse microdroplets

A method is presented for high-precision chemical detection that integrates quantum sensing with droplet microfluidics. Using nanodiamonds (ND) with fluorescent nitrogen-vacancy (NV) centers as quantum sensors, rapidly flowing microdroplets containing analyte molecules are analyzed. A noise-suppressed mode of optically detected magnetic resonance is enabled by pairing controllable flow with microwave control of NV electronic spins, to detect analyte-induced signals of a few hundredths of a percent of the ND fluorescence. Using this method, paramagnetic ions in droplets are detected with low limit-of-detection using small analyte volumes, with exceptional measurement stability over >10 3 s. In addition, these droplets are used as microconfinement chambers by co-encapsulating ND quantum sensors with various analytes such as single cells, suggesting wide-ranging applications including single-cell metabolomics and real-time intracellular measurements from bioreactors. Important advances are enabled by this work, including portable chemical testing devices, amplification-free chemical assays, and chemical imaging tools for probing reactions within microenvironments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrodynamics of a multicomponent vesicle under strong confinement

Herein we numerically investigate the hydrodynamics and membrane dynamics of a multicomponent vesicle in two strongly confined geometries. This serves as a simplified model for red blood cells undergoing large deformations while traversing narrow constrictions. We propose a new parameterization for the bending modulus that remains positive for all lipid phase parameter values. For a multicomponent vesicle passing through a stenosis, we establish connections between various properties: lipid phase coarsening, size and flow profile of the lubrication layers, excess pressure, and the tank-treading velocity of the membrane. For a multicomponent vesicle passing through a contracting channel, we find that the lipid always phase separates so that the vesicle is stiffer in the front as it passes through the constriction. For both cases of confinement we find that lipid coarsening is arrested under strong confinement, and resumes at a high rate upon relief from extreme confinement. The results may be useful for efficient sorting lipid domains using microfluidic flows by controlled release of vesicles passing through strong confinement.

97 MATHEMATICS AND COMPUTING↗

Nonequilibrium Physics of Multiphase Flow in Porous Media: Wettability and Disorder

Carbon capture and geologic storage, dissociation of methane hydrates in permafrost, enhanced oil recovery, and water dropout in low-temperature fuel cells, all have something in common: two or more fluids flow simultaneously through a porous medium; and the displacement of one fluid by another is often unstable (either due to gravity or viscous forces). Yet, our ability to model multiphase flow in porous media has remained a challenge. The traditional equations are unable to predict, explain, or even reproduce, the formation of the complex patterns observed in experiments. The overarching goal of the project is to develop new physical understanding of the role of wettability and disorder in multiphase flow through permeable media, and to develop new mathematical and computational models at the pore scale and at the continuum scale.

58 GEOSCIENCES↗

NASA Tech Briefs, September 2010

Topics covered include: Instrument for Measuring Thermal Conductivity of Materials at Low Temperatures; Multi-Axis Accelerometer Calibration System; Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems; Autonomous System for Monitoring the Integrity of Composite Fan Housings; A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation; Adaptation of the Camera Link Interface for Flight-Instrument Applications; High-Performance CCSDS Encapsulation Service Implementation in FPGA; High-Performance CCSDS AOS Protocol Implementation in FPGA; Advanced Flip Chips in Extreme Temperature Environments; Diffuse-Illumination Systems for Growing Plants; Microwave Plasma Hydrogen Recovery System; Producing Hydrogen by Plasma Pyrolysis of Methane; Self-Deployable Membrane Structures; Reactivation of a Tin-Oxide-Containing Catalys; Functionalization of Single-Wall Carbon Nanotubes by Photo-Oxidation; Miniature Piezoelectric Macro-Mass Balance; Acoustic Liner for Turbomachinery Applications; Metering Gas Strut for Separating Rocket Stages; Large-Flow-Area Flow-Selective Liquid/Gas Separator; Counterflowing Jet Subsystem Design; Water Tank with Capillary Air/Liquid Separation; True Shear Parallel Plate Viscometer; Focusing Diffraction Grating Element with Aberration Control; Universal Millimeter-Wave Radar Front End; Mode Selection for a Single-Frequency Fiber Laser; Qualification and Selection of Flight Diode Lasers for Space Applications; Plenoptic Imager for Automated Surface Navigation; Maglev Facility for Simulating Variable Gravity; Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection; High-Speed Operation of Interband Cascade Lasers; 3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events; Charge-Spot Model for Electrostatic Forces in Simulation of Fine Particulates; Hidden Statistics Approach to Quantum Simulations; Reconstituted Three-Dimensional Interactive Imaging; Determining Atmospheric-Density Profile of Titan; Digital Microfluidics Sample Analyzer; Radiation Protection Using Carbon Nanotube Derivatives; Process to Selectively Distinguish Viable from Non-Viable Bacterial Cells; and TEAMS Model Analyzer.

Source record↗

rHealth One Demonstration Aboard ISS: A Microfluidic Bioanalyzer Based on Sheath/Hydrodynamic Focusing Flow Cytometry

The Exploration Medical Capability (ExMC) element aims to provide astronauts with the means for their own health monitoring, diagnosis, and treatment during exploration missions. As space flight ventures further from earth, the need for autonomous medical care increases under greater constraints on size, mass, and resources. One pillar for diagnosis that crew would be separated from is laboratory analysis. Even now on ISS, blood samples must be collected and returned to earth for testing. In response, ExMC is assessing how assays for hematology, bone health, radiation exposure etc. could be addressed through commercial-off-the-shelf (COTS) and Small Business Innovation Research (SBIR) funded bioanalyzers that are miniaturizing lab technology. Since missions will reach distances where there are no timely replacements, validation on the International Space Station (ISS) is a necessary part of that assessment. In partnership with NASA Johnson Space Center (JSC) Immunology Lab and the Research Operations and Integration (ROI) element, ExMC conducted a technology demonstration on ISS of the rHEALTH ONE, a flow cytometry based bioanalyzer, to assess future devices based on this design. In flow cytometry, there are predominantly three ways to focus the cells (or particles) into a single file stream: hydrodynamic focusing, microcapillary, and acoustic focusing. The rHEALTH ONE utilizes the commercial standard, sheath-based hydrodynamic focusing. rHEALTH itself represents both a company and a suite of medical tools NASA has funded through SBIR grants towards the development of a promising diagnosis instrument for exploration missions. rHEALTH ONE is the interim version of the technology, functional as a benchtop analyzer and test bed for the next generation of rHEALTH in development. Several modifications were made to the rHEALTH ONE analyzer for operation in microgravity. For function, fluid management was key. A sheath-based analyzer uses sheath fluid to flow the sample, cleaning fluid to prevent biological contamination, and a reservoir to collect the liquid waste. The rHEALTH ONE analyzer uses bottles dependent on gravity to separate the air and liquid pathways and keep the liquids contained. It uses only 1 psig of air pressure to directly push the liquid through the device, requiring little-to-no resistance at inlet and outlet. A microtubing assembly with self-sealing luer connectors was designed – featuring 0.014 mm thick durable medical balloons to hold water inside the supply bottles – to create safe containment and easy access for the crew while maintaining the analyzer’s function. For safety, copper tape was added to the interior of the plastic housing to reduce electromagnetic interference, fluid and electrical connections were secured against vibration and leaks, and gaps were further sealed to ensure containment of the optical block and lasers. Water as the sheath and cleaning fluid and TOX 0 samples were used to reduce the biohazard risk to the crew. In May 2022, European Space Agency astronaut Samantha Cristoforetti demonstrated the rHEALTH ONE aboard ISS for its sample loading, flow cytometry, and data collection capability in microgravity. The JSC Immunology Lab provided flow cytometry expertise, designed the sample test protocol, and manufactured and benchmarked the flight samples on a ‘gold-standard’ flow cytometer. The analyzer was primed with water, purged of air, and four calibration solutions of polystyrene microparticles were tested to characterize its performance. Tightly controlled procedures and excellent execution prevented air bubble interference during air/water separation, fluid transfer, sample mixing and loading. Data showed a slight increase in signal noise on 3 of 5 channels and an anomaly of fluorophores migrating in one sample (confirmed by JSC post-flight). Flight results correctly detected the change in sample, matched the analyzer’s ground performance, and were consistent with the gold-standard’s ground results. Although areas were noted for improvement, these outcomes signified complete mission success.

R. S. Miller↗