Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Shape Evolution of C75 Large-Grain Niobium Half-Cells During Cavity Fabrication

The largely anisotropic deformation of large-grain Nb discs during deep drawing into half-cells poses a challenge for achieving a desired shape accuracy. Two 5-cell cavities for the C75 CEBAF cryomodule rework program have been fabricated at Jefferson Lab from large-grain Nb discs directly sliced from an ingot. The shape of the inner surface of eight half-cells has been inspected using a FARO Edge laser scanner during the fabrication process and compared to the reference shape. On average, approximately 63% of the half-cell inner surface was found to be within 0.1 mm of the reference shape and ~90% to be within 0.2 mm, after the final equator machining. Several 5-cell C75 cavities have also been fabricated at Research Instruments, Germany, and measurements of the shape accuracy using a Zeiss 3D coordinate measuring machine gave similar results. One half-cell was measured both at Research Instruments and Jefferson Lab for comparison.

Ciovati, G.↗

New capability for neutron transmission measurements at LANSCE: The DICER instrument

A new capability for neutron transmission measurements has been developed at the Los Alamos Neutron Science Center (LANSCE). The DICER (Device for Indirect Capture Experiments on Radionuclides) instrument is designed to tightly constrain neutron-capture cross sections for short-lived radionuclides that are beyond the reach of direct techniques, via measurement and analysis of neutron transmission resonances on these same radionuclides. The innovative DICER apparatus enables simultaneous sample-in and sample-out measurements, thus minimizing the amount of sample material needed and reducing the measurements time by half. A description of the current status of the new transmission station, along with a performance overview and results from known reactions, will be presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Smart System for the Contactless Measurement of Energy Expenditure

Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO 2 production, VCO 2 (mL/min), and/or O 2 consumption, VO 2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO 2 from a room’s ambient CO 2 concentration transients was evaluated. Resting EE (REE) and exercise VCO 2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration’s influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using known room’s air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE’s measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects’ VCO 2 and λ for CO 2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO 2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).

47 OTHER INSTRUMENTATION↗

Automated tape-target centering based on template matching for construction measurement tasks using robotic total station

Robotic total stations have transformed surveying and construction mapping through precise, efficient, and automated measurements. These instruments integrate a theodolite, which measures horizontal and vertical angles, with an electronic distance measurement (EDM) unit to determine distances, allowing accurate 3D measurement of observable points. Traditionally, users manually aimed the total station at a target. Recent advancements in robotic motor control and integration of cameras now enable automatic rotation and aiming, typically requiring only a single operator to position the target. Automated aiming is commonly performed using retroreflector prisms, which reflect light back to the source with minimal scattering, enabling high-precision measurements over long distances. However, retroreflectors, especially those designed for 360 degree, can be expensive and impractical for certain applications. This paper presents an algorithm for automating the center detection of low-cost disposable tape targets using the total station's onboard camera and a template matching algorithm. The algorithm identifies the target's center pixel in the image, and the instrument is commanded to aim at that location. We evaluated the performance of this template-matching-based centering method under various distances, angles, lighting conditions, and field environments, comparing its results to both manual aiming and conventional automated aiming of tape targets. Manual aiming was used as the baseline operational reference in the absence of an independent ground-truth measurement. The proposed approach achieves target centering results comparable to the manual baseline. This method provides a cost-effective alternative for high-precision applications where retroreflector targets are constrained by budget or logistics.

Harrington, Joshua [ORNL]↗

A Novel Optical Instrument for On-Line Measurement of Particle Size Distribution—Application to Clean Coal Technologies

A flow cell is a critical measurement interface for many optical instruments. However, the flows are often sampled under harsh conditions, such as under high pressure and/or high temperature, in the presence of particles, moisture, vapors with high dew points or corrosive gases. Therefore, obtaining a high-optical-quality flow cell that does not perturb the measurement is a significant challenge. To address this challenge, we proposed a new flow cell that employs a unique laminar coaxial flow field (for the purge and sample flows). A test system was built to conduct particle size distribution (PSD) measurements with no sampling bias using a state-of-the-art analyzer (Malvern Panalytical Insitec). The results revealed that the measurement zone is well defined solely by the sample flow, and the optical windows are well protected by the purge flow, with minimal risk of any depositions from the sample flow. Using this flow cell, the Insitec can successfully measure PSD under high pressure and temperature under moist, corrosive conditions without generating any sampling bias. Importantly, we successfully applied this flow cell for on-line PSD measurement for the flue gas of a 100 kWth pressurized oxy-coal combustor operating at 15 bara.

Cheng, Mao (ORCID:0000000213273900)↗

Wind Energy Instrumentation Development Roadmap

The instrumentation development roadmap provides a guide on which measurements, and instruments, are important for future field campaigns to meet both the science objects and validation plans for their successful execution. The roadmap ensures the measurements are of sufficient type and resolution to meet science objectives and validation needs essential to the campaigns. The roadmap includes measurement categories ranging from instruments that need to be created to existing instruments essential to the field campaigns. The creation of the instrumentation development roadmap builds upon the previous Atmospheric to Electrons (A2e) validation work and formation of the American WAKE experimeNt (AWAKEN) science objectives.

17 WIND ENERGY↗

Nephelometer Instrument Handbook

The Integrating Nephelometer (Figure 1) is an instrument that measures aerosol light scattering. It measures aerosol optical scattering properties by detecting (with a wide angular integration – from 7 to 170°) the light scattered by the aerosol and subtracting the light scattered by the carrier gas, the instrument walls and the background noise in the detector (zeroing). Zeroing is typically performed for 5 minutes every day at midnight UTC. The scattered light is split into red (700 nm), green (550 nm), and blue (450 nm) wavelengths and captured by three photomultiplier tubes. The instrument can measure total scatter as well as backscatter only (from 90 to 170°) (Heintzenberg and Charlson 1996; Anderson et al. 1996; Anderson and Ogren 1998; TSI 3563 2015) At ARM (Atmospheric Radiation Measurement), two identical Nephelometers are usually run in series with a sample relative humidity (RH) conditioner between them. This is possible because Nephelometer sampling is non-destructive and the sample can be passed on to another instrument. The sample RH conditioner scans through multiple RH values in cycles, treating the sample. This kind of setup allows to study how aerosol particles’ light scattering properties are affected by humidification (Anderson et al. 1996). For historical reasons, the two Nephelometers in this setup are labeled “wet” and “dry”, with the “dry” Nephelometer usually being the one before the conditioner and sampling ambient air (the names are switched for the MAOS measurement site due to the high RH of the ambient air).

47 OTHER INSTRUMENTATION↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

Entanglement Throughput Measurements and Capacity Estimates for Aerial-Inground Fiber

The throughput of entangled qubit pairs per second (eqps) is a basic performance metric of quantum networks that provide the entanglement distribution capability. Over fiber connections, it is measured using specialized instruments, including photonic entanglement sources and single-photon detectors. Extensive theory has been developed to estimate the capacity of a generic quantum channel, which in turn is applied to estimate the maximum achievable eqps over a fiber connection. However, there is a gap in relating these two performance metrics, in part due to their disparate nature, namely, mathematical formulae of the channel capacity and specialized instrumentation for eqps measurements. We describe eqps measurements collected over testbed connections composed of aerial and inground fiber of lengths up to 45 km. We estimate the normalized capacity using the transmissivity parameter derived from single photon detector measurements. These estimates are then converted to capacity bounds on the connection's eqps using the source eqps rate derived from co-located detector measurements. The results indicate a consistency between eqps measurements and their capacity estimates, and provide insights into relating the parameters of analytic capacity estimates to physical measurements.

Rao, Nageswara [ORNL] (ORCID:0000000234085941)↗

Targeted Mobile Measurements to Isolate the Impacts of Aerosols and Meteorology on Deep Convection

One of the main goals of the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Tracking Aerosol Convection Interactions Experiment (TRACER) field campaign near Houston, TX was to improve understanding of meteorology and aerosol effects on deep convective storms. To help TRACER achieve its goals of disentangling aerosol-cloud interactions from meteorology, the Texas A&M University (TAMU) team deployed the new fully mobile Rapid Onsite Atmospheric Measurement Van (ROAM-V) carrying instruments to measure aerosol and atmospheric properties that was moved to multiple locations on a deployment day of isolated convection initiated by the sea breeze.

54 ENVIRONMENTAL SCIENCES↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 uBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Assessment of Portable Optical Particle Spectrometer (POPS)

Accurate representation of atmospheric aerosol properties is a long-standing problem in atmospheric research. Modern pilotless aerial systems provide a new platform for atmospheric in situ measurement. However, small airborne platforms require miniaturized instrumentation due to apparent size, power, and weight limitations. A Portable Optical Particle Spectrometer (POPS) is an emerged instrument to measure ambient aerosol size distribution with high time and size resolution, designed for deployment on a small unmanned aerial system (UAS) or tethered balloon system (TBS) platforms. This study evaluates the performance of a POPS with an upgraded laser heater and additional temperature sensors in the aerosol pathway. POPS maintains its performance under different environmental conditions as long as the laser temperature remains above 25 °C and the aerosol flow temperature inside the optical chamber is 15 °C higher than the ambient temperature. The comparison between POPS and an Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) suggests that the coincidence error is less than 25% when the number concentration is less than 4000 cm –3 . The size distributions measured by both of them remained unaffected up to 15,000 cm –3 . While both instruments’ sizing accuracy is affected by the aerosol chemical composition and morphology, the influence is more profound on the POPS.

47 OTHER INSTRUMENTATION↗

Time-domain self-broadened and air-broadened nitrogen S-branch Raman linewidths at 80–200 K recorded in an underexpanded jet

We report pure-rotational N 2 –N 2 , N 2 –air, and O 2 –air S-branch linewidths for temperatures of 80–200 K by measuring the time-dependent decay of rotational Raman coherences in an isentropic free-jet expansion from a sonic nozzle. We recorded pure-rotational hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) spectra along the axial centerline of the underexpanded jet, within the barrel shock region upstream of the Mach disk. The dephasing of the pure-rotational Raman coherence was monitored using probe-time-delay scans at different axial positions in the jet, corresponding to varying local temperatures and pressures. The local temperature was obtained by fitting CARS spectra acquired at zero probe time delay, where the impact of collisions was minimal. The measured decay of each available Raman transition was fit to a dephasing constant and corrected for the local pressure, which was obtained from the CARS-measured static temperature and thermodynamic relationships for isentropic expansion from the known stagnation state. Nitrogen self-broadened transitions decayed more rapidly than those broadened in air for all temperatures, corresponding to higher Raman linewidths. In general, the measured S-branch linewidths deviated significantly in absolute and relative magnitudes from those predicted by extrapolating the modified exponential gap model to low temperatures. The temperature dependence of the Raman linewidth for each measured rotational state of nitrogen (J ≤ 10) and oxygen (N ≤ 11) was fit to a temperature-dependent power law over the measurable temperature domain (80–200 K) and extrapolated to both higher rotational states and room temperature. Furthermore, the measured and modeled low-temperature linewidth data provided here will aid low temperature gas-phase pressure measurements with fs/ps CARS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ARM Shortwave Spectral Radiometry Strategy Review Report

A meeting of experts in shortwave (SW) spectral measurements was held in February 2019 to discuss the current state of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrumentation and the potential scientific impact of these measurements. Instrument mentors and users reported significant progress in hyperspectral measurement quality, with good-quality data sets now possible at several field campaigns and fixed sites. Ongoing filter-based measurement improvements, including addition of the 1.6-micron channel to the multifilter rotating shadowband radiometer (MFRSR) and lunar tracking mode of the Cimel sun photometers, were also lauded as exciting developments to improve retrievals of aerosol radiative properties and size distributions.

54 ENVIRONMENTAL SCIENCES↗

ARM Shortwave Spectral Radiometry Strategy Review Report

A meeting of experts in shortwave (SW) spectral measurements was held in February 2019 to discuss the current state of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrumentation and the potential scientific impact of these measurements. Instrument mentors and users reported significant progress in hyperspectral measurement quality, with good-quality data sets now possible at several field campaigns and fixed sites. Ongoing filter-based measurement improvements, including addition of the 1.6-micron channel to the multifilter rotating shadowband radiometer (MFRSR) and lunar tracking mode of the Cimel sun photometers, were also lauded as exciting developments to improve retrievals of aerosol radiative properties and size distributions.

54 ENVIRONMENTAL SCIENCES↗

High-resolution electron time-of-flight spectrometers for angle-resolved measurements at the SQS Instrument at the European XFEL

A set of electron time-of-flight spectrometers for high-resolution angle-resolved spectroscopy was developed for the Small Quantum Systems (SQS) instrument at the SASE3 soft X-ray branch of the European XFEL. The resolving power of this spectrometer design is demonstrated to exceed 10 000 (E/ΔE), using the well known Ne 1s –1 3p resonant Auger spectrum measured at a photon energy of 867.11 eV at a third-generation synchrotron radiation source. At the European XFEL, a width of ~0.5 eV full width at half-maximum for a kinetic energy of 800 eV was demonstrated. It is expected that this linewidth can be reached over a broad range of kinetic energies. An array of these spectrometers, with different angular orientations, is tailored for the Atomic-like Quantum Systems endstation for high-resolution angle-resolved spectroscopy of gaseous samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Instrumented Capsule Design to Measure Thermal Conductivity in Miniature UO2 Specimens

Numerous separate effects irradiations of miniature nuclear fuel specimens have been conducted in the High Flux Isotope Reactor (HFIR) under the experimental platform designated as MiniFuel. MiniFuel is a static irradiation capability in which microstructural evolution and fuel performance phenomena are observed during postirradiation examination thereby offering a snapshot of the terminal fuel characteristics. This approach inherently requires fielding an irradiation where the experimental conditions are determined using predictive models and the pertinent outcomes are measured at the end of the test. Static irradiations can provide useful insights to the relationships between fuel performance and the pivotal irradiation conditions, namely temperature and burnup, but the ability to monitor fuel performance in situ would further support fuel development and qualification. To this end, an instrumented experiment design is being developed at Oak Ridge National Laboratory to capture thermal conductivity degradation and fission gas release during HFIR irradiation. These phenomena will be monitored using unique capsule designs that each target a different phenomenon. This paper details the thermal conductivity capsule (TCC) design and its expected performance envelope as determined using computer models. Each TCC will contain a miniature UO2 disc specimen (~0.5 mm thick × 5 mm diameter) sandwiched between metallic slugs with embedded thermocouples. The coupling of in situ temperature measurements, known thermal conductivity of the metallic components, and heat generation rates computed using high-fidelity neutronics models make the thermal conductivity measurement possible. This paper describes the reactor physics and heat transfer models used to predict the capsule’s performance and the methodology for calculating the fuel specimen’s thermal conductivity from the thermocouple measurements.

Gorton, Jacob [ORNL] (ORCID:0000000269806083)↗