Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loss reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Bat Smart Curtailment: Efficacy and Operational Testing

Curtailment, or blanket curtailment, is a leading method to mitigate the impacts to bats from operating wind turbines. Although this strategy results in considerable decreases in bat fatalities, it also results in decreased energy production. In 2019, Natural Power was awarded funding by the Department of Energy to assess the readiness of the informed smart curtailment technology, EchoSense (formerly referred to as Detection and Active Response Curtailment, [DARC]). The research undertaken by this project expands the understanding of alternative methods, known as smart curtailment, to maintain a reduction in bat fatalities while simultaneously recovering lost energy associated with blanket curtailment. The overall project was composed of three major tasks; Task 1 was focused on cybersecurity compliance of the EchoSense system in accordance with the North American Electric Reliability Corporation Critical Infrastructure Protection (“NERC CIP”) standards, Task 2 assessed the mechanical loads exerted on turbines when operating under a smart curtailment regime, and Task 3 assessed the efficacy of the EchoSense system at an operational wind farm. Regarding Task 1, an external review by the National Renewable Energy Laboratory determined that the EchoSense system did not create any new cybersecurity weaknesses and was compliant with the NERC CIP standards. As a result of this process, Natural Power developed some best practices (10.1) for wind- wildlife technology developers. In conjunction with the National Renewable Energy Laboratory, the results (10.2) of the loads testing demonstrated that the periodic curtailment and release of turbines by the EchoSense system did not have any detrimental impact on the mechanical components of a wind turbine (Task 2). During the late summer to fall of 2020 and 2021, Natural Power demonstrated that the use of the EchoSense smart curtailment system resulted in no significant difference in bat fatalities compared to blanket curtailment with cut-in speeds at 6.9 m/s (2020) and 5.0 m/s (2021) while resulting in a significant difference in decreased lost energy (Task 3). This translates to an average of 41% (2020) and 56% (2021) reduction in per turbine energy loss compared to blanket curtailment. The reduction in energy loss that would have been achieved by EchoSense curtailment compared to blanket curtailment, if applied across all 69 turbines, is roughly equivalent to having an additional turbine on site. These results are notable for finding a balance between the environmental impact of wind energy and the economic feasibility in energy production associated with mitigating that impact. https://www.naturalpower.com/us/expertise/service/engineering-operations/echosense

17 WIND ENERGY↗

Spectral changes in conifers subjected to air pollution and water stress: Experimental studies

The roles of leaf anatomy, moisture and pigment content, and number of leaf layers on spectral reflectance in healthy, pollution-stressed, and water-stressed conifer needles were examined experimentally. Jeffrey pine (Pinus jeffreyi) and giant sequoia (Sequoiadendron gigantea) were exposed to ozone and acid mist treatments in fumigation chambers; red pine (Pinus resinosa) needles were artificially dried. Infrared reflectance from stacked needles rose with free water loss. In an air-drying experiment, cell volume reductions induced by loss of turgor caused near-infrared reflectance (TM band 4) to drop after most free water was lost. Under acid mist fumigation, stunting of tissue development similarly reduced band 4 reflectance. Both artificial drying and pollutant fumigation caused a blue shift of the red edge of spectral reflectance curves in conifers, attributable to chlorophyll denaturation. Thematic mapper band ratio 4/3 fell and 5/4 rose with increasing pollution stress on artificial drying. Loss of water by air-drying, freeze-drying, or oven-drying enhanced spectral features, due in part to greater scattering and reduced water absorption. Grinding of the leaf tissue further enhanced the spectral features by increasing reflecting surfaces and path length. In a leaf-stacking experiment, an asymptote in visible and infrared reflectance was reached at 7-8 needle layers of red pine.

Westman, Walter E.↗

Process for Making Carbon-Carbon Turbocharger Housing Unit for Intermittent Combustion Engines

An improved. lightweight, turbine housing unit for an intermittent combustion reciprocating internal combustion engine turbocharger is prepared from a lay-up or molding of carbon-carbon composite materials in a single-piece or two-piece process. When compared to conventional steel or cast iron, the use of carbon-carbon composite materials in a turbine housing unit reduces the overall weight of the engine and reduces the heat energy loss used in the turbo-charging process. This reduction in heat energy loss and weight reduction provides for more efficient engine operation.

Northam, G. Burton↗

Performance of a Cylindrical Hall-Effect Thruster with Magnetic Field Generated by Permanent Magnets

While Hall thrusters can operate at high efficiency at kW power levels, it is difficult to construct one that operates over a broad envelope down to 100W while maintaining an efficiency of 45- 55%. Scaling to low power while holding the main dimensionless parameters constant requires a decrease in the thruster channel size and an increase in the magnetic field strength. Increasing the magnetic field becomes technically challenging since the field can saturate the miniaturized inner components of the magnetic circuit and scaling down the magnetic circuit leaves very little room for magnetic pole pieces and heat shields. An alternative approach is to employ a cylindrical Hall thruster (CHT) geometry. Laboratory model CHTs have operated at power levels ranging from the order of 50 Watts up to 1 kW. These thrusters exhibit performance characteristics which are comparable to conventional, annular Hall thrusters of similar size. Compared to the annular Hall thruster, the CHT has a lower insulator surface area to discharge chamber volume ratio. Consequently, there is the potential for reduced wall losses in the channel of a CHT, and any reduction in wall losses should translate into lower channel heating rates and reduced erosion. This makes the CHT geometry promising for low-power applications. Recently, a CHT that uses permanent magnets to produce the magnetic field topology was tested. This thruster has the promise of reduced power consumption over previous CHT iterations that employed electromagnets. Data are presented for two purposes: to expose the effect different controllable parameters have on the discharge and to summarize performance measurements (thrust, Isp, efficiency) obtained using a thrust stand. These data are used to gain insight into the thruster's operation and to allow for quantitative comparisons between the permanent magnet CHT and the electromagnet CHT.

Polzin, Kurt A.↗

Performance of a Cylindrical Hall-Effect Thruster Using Permanent Magnets

While annular Hall thrusters can operate at high efficiency at kW power levels, it is difficult to construct one that operates over a broad envelope from 1 kW down to 100 W while maintaining an efficiency of 45-55%. Scaling to low power while holding the main dimensionless parameters constant requires a decrease in the thruster channel size and an increase in the magnetic field strength. Increasing the magnetic field becomes technically challenging since the field can saturate the miniaturized inner components of the magnetic circuit and scaling down the magnetic circuit leaves very little room for magnetic pole pieces and heat shields. In addition, the central magnetic pole piece defining the interior wall of the annular channel can experience excessive heat loads in a miniaturized Hall thruster, with the temperature eventually exceeding the Curie temperature of the material and in extreme circumstances leading to accelerated erosion of the channel wall. An alternative approach is to employ a cylindrical Hall thruster (CHT) geometry. Laboratory model CHTs have operated at power levels ranging from 50 W up to 1 kW. These thrusters exhibit performance characteristics that are comparable to conventional, annular Hall thrusters of similar size. Compared to the annular Hall thruster, the CHTs insulator surface area to discharge chamber volume ratio is lower. Consequently, there is the potential for reduced wall losses in the channel of a CHT, and any reduction in wall losses should translate into lower channel heating rates and reduced erosion, making the CHT geometry promising for low-power applications. This potential for high performance in the low-power regime has served as the impetus for research and development efforts aimed at understanding and improving CHT performance. Recently, a 2.6 cm channel diameter permanent magnet CHT (shown in Fig. 1) was tested. This thruster has the promise of reduced power consumption over previous CHT iterations that employed electromagnets. Data are presented to expose the effect different controllable parameters have on the discharge and to summarize performance measurements (thrust, Isp, efficiency) obtained using a thrust stand. In addition, beam current data are presented to show the effect of the magnetic field topology on the plume profile and current utilization and to gain insight into the thruster s operation. These data extend and improve upon the results previously presented by the authors in Ref. [1].

Polzin, Kurt A.↗

Results from a wake-steering experiment at a commercial wind plant: investigating the wind speed dependence of wake-steering performance

Wake steering is a wind farm control strategy in which upstream wind turbines are misaligned with the wind to redirect their wakes away from downstream turbines, thereby increasing the net wind plant power production and reducing fatigue loads generated by wake turbulence. In this paper, we present results from a wake-steering experiment at a commercial wind plant involving two wind turbines spaced 3.7 rotor diameters apart. During the 3-month experiment period, we estimate that wake steering reduced wake losses by 5.6% for the wind direction sector investigated. After applying a long-term correction based on the site wind rose, the reduction in wake losses increases to 9.3%. As a function of wind speed, we find large energy improvements near cut-in wind speed, where wake steering can prevent the downstream wind turbine from shutting down. Yet for wind speeds between 6–8 m/s, we observe little change in performance with wake steering. However, wake steering was found to improve energy production significantly for below-rated wind speeds from 8–12 m/s. By measuring the relationship between yaw misalignment and power production using a nacelle lidar, we attribute much of the improvement in wake-steering performance at higher wind speeds to a significant reduction in the power loss of the upstream turbine as wind speed increases. Additionally, we find higher wind direction variability at lower wind speeds, which contributes to poor performance in the 6–8 m/s wind speed bin because of slow yaw controller dynamics. Further, we compare the measured performance of wake steering to predictions using the FLORIS (FLOw Redirection and Induction in Steady State) wind farm control tool coupled with a wind direction variability model. Although the achieved yaw offsets at the upstream wind turbine fall short of the intended yaw offsets, we find that they are predicted well by the wind direction variability model. When incorporating the expected yaw offsets, estimates of the energy improvement from wake steering using FLORIS closely match the experimental results.

17 WIND ENERGY↗

Hot Hydrogen Exposure of U x Zr 1-x C y Nuclear Fuel: The Effect of Additional Carbon

Nuclear thermal propulsion (NTP) using hydrogen as propellant in a solid-state fission reactor to reach temperatures of up to 3000K can achieve significantly higher specific impulse than chemical propulsion. A promising fuel that is again considered for NTP is U x Zr 1-x C y . To reduce the overall mass loss as well as the uranium fuel loss, a range of experiments using additional carbon in hot hydrogen (2600 K, 6 SLPM flow rate) were performed for up to 5-6 h. Both a CH 4 addition (0.1 and 0.2 vol%) in the hydrogen stream and the use of sacrificial graphite pieces upstream of the samples were tested, with sample compositions from 5 at% UC to 30 at% UC. The results showed a strong reduction of mass loss, up to a factor of 3, as well as a reduction of surface uranium losses in the presence of additional carbon in the atmosphere. Even with additional carbon in the atmosphere, material with 30 at% UC was not stable, but material with 20 at% UC was stable for up to 6h. The sample surfaces showed texturing after processing, possibly by grain growth on the surface. This led to a separation into grains with high uranium content close to the (100)-orientation, and with low uranium content in grains close to the (111)-orientation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Conversion Losses In GaAs Schottky-Barrier Diodes

Parasitic losses reduced with lightly doped epitaxial layers of proper thickness. Report presents calculations of conversion losses in Schottky-barrier diodes. Theoretical work directed toward reduction of parasitic losses through proper design of space-charge layers; possible, to reduce barrier capacitances and contributions to barrier resistances from undepleted epitaxial layers.

Von Roos, Oldwig↗

Soft Switching Over the Entire Line Cycle for a Quadruple Active Bridge DCX in a DC to Three-Phase AC Module

This paper is focused on a transformer-isolated quadruple active bridge (QAB) dc-dc converter loaded by three full-bridge dc-ac inverters. The QAB functions as a "DC trans-former" (DCX) in the dc-to-three-phase ac module. The QAB outputs provide time-varying power at twice the line frequency, which presents challenges in maintaining zero voltage switching (ZVS) on the secondary sides during low-power portions of the line cycle. It is shown how ZVS can be achieved in a phase, even at zero-power transfer, using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. The approach is particularly effective in high-voltage applications using SiC MOSFETs, where reductions in switching loss outweigh additional conduction losses due to the circulating currents. A detailed analysis of ZVS switching waveforms at the zero power transfer is presented, including effects of nonlinear device capacitances. Analytical expressions are given for the optimal values of the magnetizing inductance and dead times of the QAB primary and secondary bridges. The approach is verified by experimental results on a 600 V, 4 kW prototype, demonstrating greater than 98.5% efficiency from 1 kW to 4 kW, with a peak efficiency of 99.0%. Compared to conventionally operated prototype, a 54% reduction in total loss is achieved at rated power.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Localization and reduction of superconducting quantum coherent circuit losses

Quantum sensing and computation can be realized with superconducting microwave circuits. Qubits are engineered quantum systems of capacitors and inductors with non-linear Josephson junctions. They operate in the single-excitation quantum regime, photons of $27 \mu$eV at 6.5 GHz. Quantum coherence is fundamentally limited by materials defects, in particular atomic-scale parasitic two-level systems (TLS) in amorphous dielectrics at circuit interfaces.[1] The electric fields driving oscillating charges in quantum circuits resonantly couple to TLS, producing phase noise and dissipation. We use coplanar niobium-on-silicon superconducting resonators to probe decoherence in quantum circuits. By selectively modifying interface dielectrics, we show that most TLS losses come from the silicon surface oxide, and most non-TLS losses are distributed throughout the niobium surface oxide. Through post-fabrication interface modification we reduced TLS losses by 85% and non-TLS losses by 72%, obtaining record single-photon resonator quality factors above 5 million and approaching a regime where non-TLS losses are dominant. [1]M\"uller, C., Cole, J. H. & Lisenfeld, J. Towards understanding two-level-systems in amorphous solids: insights from quantum circuits. Rep. Prog. Phys. 82, 124501 (2019)

Altoé, M Virginia P↗

A three-dimensional Navier-Stokes stage analysis of the flow through a compact radial turbine

A steady, three dimensional Navier-Stokes average passage computer code is used to analyze the flow through a compact radial turbine stage. The code is based upon the average passage set of equations for turbomachinery, whereby the flow fields for all passages in a given blade row are assumed to be identical while retaining their three-dimensionality. A stage solution is achieved by alternating between stator and rotor calculations, while coupling the two solutions by means of a set of axisymmetric body forces which model the absent blade row. Results from the stage calculation are compared with experimental data and with results from an isolated rotor solution having axisymmetric inlet flow quantities upstream of the vacated stator space. Although the mass-averaged loss through the rotor is comparable for both solutions, the details of the loss distribution differ due to stator effects. The stage calculation predicts smaller spanwise variations in efficiency, in closer agreement with the data. The results of the study indicate that stage analyses hold promise for improved prediction of loss mechanisms in multi-blade row turbomachinery, which could lead to improved designs through the reduction of these losses.

Heidmann, James D.↗

A three-dimensional Navier-Stokes stage analysis of the flow through a compact radial turbine

A steady, three-dimensional Navier-Stokes average passage computer code is used to analyze the flow through a compact radial turbine stage. The code is based upon the average passage set of equations for turbomachinery, whereby the flow fields for all passages in a given blade row are assumed to be identical while retaining their three-dimensionality. A stage solution is achieved by alternating between stator and rotor calculations, while coupling the two solutions by means of a set of axisymmetric body forces which model the absent blade row. Results from the stage calculation are compared with experimental data and with results from an isolated rotor solution having axisymmetric inlet flow quantities upstream of the vacated stator space. Although the mass-averaged loss through the rotor is comparable for both solutions, the details of the loss distribution differ due to stator effects. The stage calculation predicts smaller spanwise variations in efficiency, in closer agreement with the data. The results of the study indicate that stage analyses hold promise for improved prediction of loss mechanisms in multi-blade row turbomachinery, which could lead to improved designs through the reduction of these losses.

Heidmann, James D.↗

Evaluation of induction motor performance using an electronic power factor controller

The concept of reducing the losses in an induction motor by electronically controlling the time interval between the zero crossing of the applied voltage and the zero crossing of the armature current was evaluated. The effect on power losses and power factor of reducing the applied sinusoidal voltages below the rated value was investigated experimentally. The reduction in power losses was measured using an electronic controller designed and built at MSFC. Modifications to the MSFC controller are described as well as a manually controlled electronic device which does not require that the motor be wye connected and the neutral available. Possible energy savings are examined.

Source record↗

An alternative to Guyan reduction of finite-element models

Structural modeling is a key part of structural system identification for large space structures. Finite-element structural models are commonly used in practice because of their general applicability and availability. The initial models generated by using a standard computer program such as NASTRAN, ANSYS, SUPERB, STARDYNE, STRUDL, etc., generally contain tens of thousands of degrees of freedom. The models must be reduced for purposes of identification. Not only does the magnitude of the identification effort grow exponentially as a function of the number of degrees of freedom, but numerical procedures may also break down because of accumulated round-off errors. Guyan reduction is usually applied after a static condensation. Misapplication of Guyan reduction can lead to serious modeling errors. It is quite unfortunate and disappointing, since the accuracy of the original detailed finite-element model one tries very hard to achieve is lost by the reduction. First, why and how Guyan reduction always causes loss of accuracy is examined. An alternative approach is then introduced. The alternative can be thought of as an improvement of Guyan reduction, the Rayleigh-Ritz method, and in particular the recent algorithm of Wilson, Yuan, and Dickens. Unlike Guyan reduction, the use of the alternative does not need any special insight, experience, or skill for partitioning the structural degrees of freedom. In addition to model condensation, this alternative approach can also be used for predicting analytically, quickly, and economically, what are those structural modes that are excitable by a force actuator at a given trial location. That is, in the excitation of the structural modes for identification, it can be used for guiding the placement of the force actuators.

Lin, Jiguan Gene↗

Direct Prelithiation of Silicon-Based Composite Electrodes via Island-like Thermal Evaporation

Irreversible losses of Li during solid electrolyte interface (SEI) conditioning is a key contributor to the lower specific capacities observed in silicon-containing Li-ion batteries. Herein, thermal evaporation of between 1 and 20 µm of Li onto Si-based composite anodes has been investigated as a prelithiation method to account for such losses. To account for mechanical strain caused by Li-Si alloying during the deposition, a stainless-steel mesh is applied to the electrodes before prelithiation to form “island-like” deposition on the electrode surface. The open circuit potential was also found to decrease as a function of increased Li evaporation, consistent with the potentials of electrochemically prepared LixSi alloys. Prelithiating to account for irreversible Li losses to SEI formation resulted in full cells with a 15.8% increase in initial coulombic efficiency and a 47.8% reduction in irreversible capacity loss after SEI formation cycling. Subsequent C/3 cycling showed up to a 62.9% increase in specific capacity in prelithiated cells. X-ray photoelectron spectroscopy (XPS) revealed differences in the SEI composition that was formed by electrochemical cycling and reactively formed in prelithiated cells upon exposure to Gen2 + 3% FEC electrolyte. The reactively formed SEI from the spontaneous reaction with lithiated silicon was carbonate-rich while the electrochemical SEI formation showed significantly more LiPFx species, which could play a role in overall cycling performance.

Musgrove, Amanda↗

High-Speed Jet Noise Reduction NASA Perspective

History shows that the problem of high-speed jet noise reduction is difficult to solve. the good news is that high performance military aircraft noise is dominated by a single source called 'jet noise' (commercial aircraft have several sources). The bad news is that this source has been the subject of research for the past 50 years and progress has been incremental. Major jet noise reduction has been achieved through changing the cycle of the engine to reduce the jet exit velocity. Smaller reductions have been achieved using suppression devices like mixing enhancement and acoustic liners. Significant jet noise reduction without any performance loss is probably not possible! Recent NASA Noise Reduction Research Programs include the High Speed Research Program, Advanced Subsonic Technology Noise Reduction Program, Aerospace Propulsion and Power Program - Fundamental Noise, and Quiet Aircraft Technology Program.

Huff, Dennis L.↗

Isokinetic and isometric strength-endurance after 6 hours of immersion and 6 degrees head-down tilt in men

PURPOSE: To determine weight (water) loss levels for onset of muscular strength and endurance changes during deconditioning. METHODS: Seven men (27-40 yr) performed maximal shoulder-, knee-, and ankle-joint isometric (0 degree.s(-1) load) and isokinetic (60 degrees, 120 degrees, 180 degrees.s(-1) velocity) exercise tests during ambulatory control (AC), after 6 h of 6 degrees head-down tilt (HDT; dry-bulb temp. = 23.2 +/- SD 0.6 degrees C, relative humidity = 31.1+/- 11.1%) and after 6 h of 80 degrees foot-down head-out water immersion (WI; water temp. = 35.0 +/- SD 0.1 degree C) treatments. RESULTS: Weight (water) loss after HDT (1.10 +/- SE 0.14 kg, 1.4 +/- 0.2% body wt) and WI (1.54+/- 0.19 kg, 2.0 +/- 0.2% body wt) were not different, but urinary excretion with WI (1,354 +/- 142 ml.6 h(-1)) was 28% greater (p < 0.05) than that of 975 +/- 139 ml.6 h(-1) with HDT. Muscular endurance (total work; maximal flexion-extension of the non-dominant knee at 180 degrees.s(-1) for 30 s) was not different between AC and the WI or HDT treatments. Shoulder-, knee-, and ankle-joint strength was unchanged except for three knee-joint peak torques: AC torque (120 degrees.s(-1), 285 +/- 20 Nm) decreased to 268 +/- 21 Nm (delta = -6%, p < 0.05) with WI; and AC torques (180 degrees.s(-1), 260 +/- 19 Nm) decreased to 236 +/- 15 Nm (delta = -9%, p < 0.01) with HDT, and to 235 +/- 19 Nm (delta = -10%, p < 0.01) with WI. CONCLUSION: Thus, the total body hypohydration threshold level for shoulder- and ankle-joint strength and endurance decrements is more than 2% body weight (water) loss, while significant reduction in knee-joint muscular strength-endurance occurred only at moderate (120 degrees.s(-1) and lighter (180 degrees.s(-1)) loads with body weight loss of 1.4-2.0% following WI or HDT, respectively. These weight (water) losses and knee-joint strength decrements are somewhat less than the mean weight loss of 2.6% and knee-joint strength decrements of 6-20% of American astronauts after Skylab flights to 84 d.

NASA Center ARC↗

Performance Analyses of Supercritical Carbon Dioxide-Based Parabolic Trough Collectors with Double-Glazed Receivers

Supercritical carbon dioxide is becoming a hot research topic as a potential heat transfer fluid in parabolic trough concentrators since it enables operating the solar system at high temperatures for a higher quality of energy. However, the corresponding inflated thermal losses necessitate alternative receiver designs. This work examines four double-glazed receivers, with each annular space being evacuated or non-evacuated, in terms of the absorber tube's diameter (53-80 mm) and the diameter ratios of the two glass shells (1.2-2.0). An analytical model is developed and validated for this purpose, and the four designs are further examined using ground-level solar and meteorological measurements. The results demonstrate higher performance in the case of fully evacuating the receiver and using the smallest possible diameters of the three concentric cylinders, where the energy and exergy efficiencies reach 65.3 and 40.3%, respectively. Yet, evacuating only the inner annular space is sufficient to achieve virtually the same performance level. This energy efficiency decreases to 62% in case of increasing the tube diameter to 80 mm. As the operating temperature increases from 423 to 850 K, the specific thermal losses increase by 3.98-4.34 folds, depending on the receiver design. Double glazing the receivers is favorable only at high operating temperatures of sCO2, where the reduction in thermal losses overcomes the drop in optical efficiency. For an inlet sCO2 temperature of 850 K, thermal losses are reduced by 33.64 and 53.92%, compared to evacuated and non-evacuated single-glazed receivers, respectively. Throughout the year, the fully evacuated and fully non-evacuated double-glazed receivers have energy efficiencies of 54.96 and 52.39%, exergy efficiencies of 33.64 and 32.06%, and thermal losses of 348.8 and 402.5 W/m, respectively.

analytical model↗