An alternate method for achieving temperature control in the -130 C to 75 C range

Thermal vacuum testing often requires temperature control of chamber shrouds and heat exchangers within the -130 C to 75 C range. There are two conventional methods which are normally employed to achieve control through this intermediate temperature range: (1) single-pass flow where control is achieved by alternately pulsing hot gaseous nitrogen (GN2) and cold LN2 into the feed line to yield the setpoint temperature; and (2) closed-loop circulation where control is achieved by either electrically heating or LN2 cooling the circulating GN2 to yield the setpoint temperature. A third method, using a mass flow ratio controller along with modulating control valves on GN2 and LN2 lines, provides excellent control but equipment for this method is expensive and cost-prohibitive for all but long-term continuous processes. The single-pass method provides marginal control and can result in unexpected overcooling of the test article from even a short pulse of LN2. The closed-loop circulation method provides excellent control but requires an expensive blower capable of operating at elevated pressures and cryogenic temperatures. Where precise control is needed (plus or minus 2 C), single-pass flow systems typically have not provided the precision required, primarily because of overcooling temperature excursions. Where several individual circuits are to be controlled at different temperatures, the use of expensive cryogenic blowers for each circuit is also cost-prohibitive, especially for short duration of one-of-a-kind tests. At JPL, a variant of the single-pass method was developed that was shown to provide precise temperature control in the -130 C to 75 C range while exhibiting minimal setpoint overshoot during temperature transitions. This alternate method uses a commercially available temperature controller along with a GN2/LN2 mixer to dampen the amplitude of cold temperature spikes caused by LN2 pulsing. The design of the GN2/LN2 mixer, the overall control system configuration, the operational procedure, and the prototype system test results are described.

Johnson, Kenneth R.↗

The 24 Million Kilometer Optical Link with the Mercury Laser Altimeter

A recent experiment has been completed at NASA Goddard Geophysical and Astronomical Observatory (GGAO) where an optical link has been achieved with the Mercury laser altimeter (MLA) instrument about the Messenger spacecraft on its way to Mercury. A pulsed laser source at 1 micron based on Earth has been recorded on MLA. Simultaneously, the spacecrafts altimeter has been properly aimed and laser pulses transmitted to earth where they were detected and recorded at the same facility. This optical link was used to calibrate and verify operation of the MLA instrument and onboard laser, as well as to gain valuable information with the methods and means of very long range optical communication pointing and receiving techniques. An overview of this experiment, the hardware, and data products will be presented.

Coyle, Donald B.↗

A low-power battery ampere-hour meter

A digital device has been developed to meter the current drain of a battery in ampere hours. The device consists of a voltage controlled oscillator (VCO), a frequency divider, an accumulator, and a liquid crystal display. A voltage proportional to load current is converted into a clock signal whose pulse rate is scaled by the frequency divider to the desired engineering units. Final output pulses are counted and displayed. The use of MOSFET and CMOS integrated circuits allows continuous battery-powered operation over a 3-month time period to an accuracy of +/- 2 percent. The instrument will find application where accurate monitoring of battery charge/discharge status is required over long time intervals.

Tripp, John S.↗

Sensors and sensor systems for guidance and navigation II; Proceedings of the Meeting, Orlando, FL, Apr. 22, 23, 1992

Topics discussed in this volume include aircraft guidance and navigation, optics for visual guidance of aircraft, spacecraft and missile guidance and navigation, lidar and ladar systems, microdevices, gyroscopes, cockpit displays, and automotive displays. Papers are presented on optical processing for range and attitude determination, aircraft collision avoidance using a statistical decision theory, a scanning laser aircraft surveillance system for carrier flight operations, star sensor simulation for astroinertial guidance and navigation, autonomous millimeter-wave radar guidance systems, and a 1.32-micron long-range solid state imaging ladar. Attention is also given to a microfabricated magnetometer using Young's modulus changes in magnetoelastic materials, an integrated microgyroscope, a pulsed diode ring laser gyroscope, self-scanned polysilicon active-matrix liquid-crystal displays, the history and development of coated contrast enhancement filters for cockpit displays, and the effect of the display configuration on the attentional sampling performance.

Welch, Sharon S.↗

NASA's Radio Frequency Bolt Monitor: A Lifetime of Spinoffs

This story begins in the 1970s, when Dr. Joseph Heyman, a young scientist at NASA s Langley Research Center, was asked to support the investigation of a wind tunnel accident at a sister center. Although the work was outside of his physics background, it sparked a research focus that guided his lengthy NASA career and would earn him a slew of accolades, including NASA s highest award medals for Exceptional Leadership, Exceptional Achievement, and Exceptional Service; the coveted Silver Snoopy Astronaut Award for Space Shuttle Return to Flight; and the Arthur Fleming Award for being one of the Top Ten Federal Scientists in Government Service. He won 30 additional NASA awards, including the Agency s Invention of the Year and the Agency s highest award for technology transfer, and was the only person to ever win 4 R&D 100 Awards. Back in 1973, though, Heyman was a young civil servant with a background in physics who was asked to sit on an accident review panel. The panel met at Ames Research Center, in Moffet Field, California, and after considerable investigation, concluded that a high-pressure pebble heater used for heating gas had failed, due to improperly tightened bolts in a 1,000-pound gate valve control section. The accident showered the facility with incendiary ceramic spheres and nearly a ton of metal, but, luckily, caused no injuries. Heyman returned to Langley and began work on a solution. He developed an ultrasonic device that would measure bolt elongation, as opposed to torque, the factor typically measured in testing bolt preload or tension. Torque measurement can lead to load errors, with miscalculations as high as 80 percent that can be passed over during installation. Bolt stretch, however, is nearly always accurate to 1 percent or better. Within 1 month, he had an acoustic resonance solution that accurately determined bolt elongation. He assumed his work on this project had ended, but it was actually the start of nearly 15 years of work perfecting, improving, inventing, and modifying the "bolt monitor", all the while, filing numerous patents, presenting papers, and holding demonstrations as the technology matured. Industry engineers challenged Heyman s inventiveness, and reminded the physicist that most bolts are not perfect resonators, and that early devices required that the bolt have reasonably flat and parallel faces. The U.S. Geological Survey asked NASA for help in determining the load in mine roof bolts, which are 8- to 10-feet-long and rough cut. To solve that problem, Heyman modified the original device to operate at a lower frequency and to generate propagation modes that could be used to "lock" the instrument on a particular mode. Further work in this vein led to the development of the Pulsed Phase Locked Loop (P2L2) that worked on the mine bolts. The next set of problems involved high-strength bolts with head markings. For this solution, Heyman invented a modified P2L2 that tracked a specific phase point in the measurement wave. This class of instrumentation, well suited to measuring small changes in acoustic velocity, won the NASA "Invention of the Year" award in 1982. Other scientists and engineers have continued the evolution of this technology both inside NASA and outside of the Agency. Within NASA, the technology has been improved for medical applications, with a particular focus on intercranial pressure (ICP) monitoring.

Source record↗

Aerosol analysis techniques and results from micro pulse lidar

The effect of clouds and aerosol on the atmospheric energy balance is a key global change problem. Full knowledge of aerosol distributions is difficult to obtain by passive sensing alone. Aerosol and cloud retrievals in several important areas can be significantly improved with active remote sensing by lidar. Micro Pulse Lidar (MPL) is an aerosol and cloud profilometer that provides a detailed picture of the vertical structure of boundary layer and elevated dust or smoke plume aerosols. MPL is a compact, fully eyesafe, ground-based, zenith pointing instrument capable of full-time, long-term unattended operation at 523 nm. In October of 1993, MPL began taking full-time measurements for the Atmospheric Radiation Measurement (ARM) program at its Southern Great Plains (SGP) site and has since expanded to ARM sites in the Tropical West Pacific (TWP) and the North Slope of Alaska (NSA). Other MPL's are moving out to some of the 60 world-wide Aerosol Robotic Network (AERONET) sites which are already equipped with automatic sun-sky scanning spectral radiometers providing total column optical depth measurements. Twelve additional MPL's have been purchased by NASA to add to the aerosol and cloud database of the EOS ground validation network. The original MPL vertical resolution was 300 meters but the newer versions have a vertical resolution of 30 meters. These expanding data sets offer a significant new resource for atmospheric radiation analysis. Under the direction of Jim Spinhirne, the MPL analysis team at NASA/GSFC has developed instrument correction and backscatter analysis techniques for ARM to detect cloud boundaries and analyze vertical aerosol structures. A summary of MPL applications is found in Hlavka (1997). With the aid of independent total column optical depth instruments such as the Multifilter Rotating Shadowband Radiometer (MFRSR) at the ARM sites or sun photometers at the AERONET sites, the MPL data can be calibrated, and time-resolved vertical profiles of aerosol optical depth as well as aerosol extinction can be calculated. The techniques used to calibrate the lidar, calculate the aerosol extinction-to-backscatter ratio, and produce profiles of aerosol extinction and aerosol optical depths, will be described. Results using these techniques will be presented for case studies at the ARM site in the Tropical West Pacific and later in the Southern Great Plains.

Hlavka, Dennis L.↗

Unseeded Scalar Velocity Measurements for Propulsion Flows

Unseeded molecular tagging methods based on single-photon processes that produce long tag lines (>50 mm) have been recently developed and demonstrated by the Combustion Laser Diagnostics Group (Mechanical Engineering Department) at Vanderbilt University [1,2]. In Ozone Tagging Velocimetry (OTV) a line of ozone (O3) is produced by a single photon from a pulsed narrowband argon fluoride (ArF) excimer laser operating at - 193 nm. After a known time delay, t, the position of the displaced (convected in the flow field) O3 tag line is revealed by photodissociation of O3 and subsequent fluorescence of O2, caused by a pulsed laser sheet from a krypton fluoride (KrF) excimer laser operating at - 248 nm. Intensified CCD camera images of the fluorescence are taken from the initial and final tag line locations thus providing unobtrusive means of establishing a velocity profile in the interrogated flow field. The O3 lines are "written" and subsequently "read" by the following reactions:

Pitz, Robert W.↗

Modeling of Initial Detonation-mode Acceleration in Pulsed Plasma and Magnetoplasmadynamic Thrusters

Gas-fed electromagnetic pulsed plasma accelerators operate by discharging electrical energy into a gas, subsequently ionizing and electromagnetically accelerating propellant. Many efforts to model pulsed accelerators have assumed that the discharge is either short and completely transient, accelerating the gas like a shock by entraining it in a moving current sheet, or that the discharge is relatively long, establishing a stable quasi-steady current distribution through which plasma flows and is accelerated. This idealization encounters problems when thrusters possess some qualities associated with both short and long-pulse-length thrusters. To capture all possible scenarios, a model is presented based upon the idea that all pulsed plasma accelerators first form an accelerating current sheet (detonation mode accelerator) and then, depending upon the pulse length and the manner in which the plasma reaches the thruster exit, it can transition to the quasi-steady acceleration configuration (deflagration mode accelerator). In the present work the detonation mode is investigated, varying controllable parameters to determine their effects on the plasma acceleration process. The primary driver affecting current sheet acceleration is the amount of gas that the plasma encounters and entrains as it moves towards the thruster exit. The amount of neutral gas the plasma entrains affects the time it takes the plasma to reach the end of the accelerator and changes the corresponding electrical discharge parameters at the end of detonation mode acceleration.

Polzin, Kurt A.↗

A Multi-Faceted Approach to Demonstrating Multi-Functional Integrated Medical Devices to Advance Earth-Independent Medical Operations

INTRODUCTION TO MIM DEVICES Multi-functional Integrated Medical (MIM) devices conveniently incorporate multiple medical system capabilities within one device. The NASA Exploration Medical Integrated Product Team (XM-IPT) sponsored a market survey and trade study which identified the Tempus ProTM and the LifeBot 10® as the MIM devices that best met the evaluation criteria of the trade study. The Tempus ProTM (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) and LifeBot 10® (LifeBot Health, Chicago, IL) both provide vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature along with ultrasound imaging. A video laryngoscopy capability is unique to the Tempus ProTM, while the LifeBot 10® supports connectivity with a digital stethoscope, otoscope, eye exam camera, and dermatoscope. Both devices include procedural guidance capabilities and have various data transmission and report generation features. TECHNOLOGY DEMONSTRATIONS NASA’s exploration-class missions will have severe resource constraints, long return trip durations, significant communication delays, and limited resupply opportunities. The medical systems of these missions will need to fit within an Earth-Independent Medical Operations (EIMO) construct. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. Evaluations are underway to determine if it will be beneficial to include MIM devices within exploration medical systems by conducting a series of planned technical demonstrations. Exploration Atmosphere Chamber studies are being performed to determine MIM functionality in a high oxygen concentration atmosphere. A side-by-side comparison of the Tempus ProTM and LifeBot 10® will be performed during ground-based demonstrations. Use of the MIM devices within an EIMO medical scenario simulation will be practiced during ground-based demonstrations in preparation for International Space Station (ISS) demonstrations of the MIM device. These various demonstrations are designed to gather evidence for or against the inclusion of MIM devices within an EIMO medical system. EXPECTED DEMONSTRATION OUTCOMES Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis. Information will also be collected about performance differences as available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities, which take the EIMO construct into consideration.

B. E. Lewandowski↗

Lidar Measurements of Methane and Applications for Aircraft and Spacecraft

Atmospheric methane levels have remained relatively constant over the last decade around 1.78 parts per million (ppm) but observations since 2007 show that levels may be increasing. This trend may be caused by increased fossil fuel production, rice farming, livestock and landfills, but the underlying causes are quite uncertain. One hypothesis is that reservoirs of carbon trapped in the permafrost regions of northern Canada, Europe, and Siberia thaw as global temperatures rise and are releasing increasing amounts of methane. Another hypothesis points to increased production of methane by microbes as the permafrost warms. Currently most observations of greenhouse gases are limited to in-situ (surface and tower sites) and limited airborne in-situ measurements. Space column density measurements are starting to become available from the GOSAT mission. Although methane survives for a shorter time in the atmosphere than CO2, its impact on climate change per molecule is about 23 times than that of CO2. Accurate global observations of several greenhouse gases, including methane, are urgently needed in order to better understand climate change processes and to reduce the uncertainty in the carbon budget. Differential absorption lidar is a well-established technique to measure atmospheric gases, and methane has optical absorption bands near 1.65,2.2,3.4 and 7.8 micron. The near infrared overtones lines of CH4 near 1650 nm are relatively free of interference from other species. There are absorption lines near 1651 nm which are both temperature insensitive and have line strengths well suited for lidar measurements. We have developed a laser and demonstrated lidar measurements of CH4 using lines in this band. Our laser uses a narrow linewidth 1064 nm laser pulse passing through a nonlinear crystal. We generate the tunable laser signals near 1651 nm by using the optical parametric amplification (OPA) process. Inside the crystal the 1064 nm beam overlaps with an injection seed laser near 1651 nm from a wavelength tunable diode laser. Incident photons from the pump laser pulse are converted into two photons, with one at the wavelength of the injection seeder. The wavelength of the OPA output is tuned via the wavelength of diode laser. Our laser is tunable, operates near 1651 nm and generates approximately 4 uJ/pulse at 6 KHz. We vary the emission wavelengths within this band by tuning the diode laser's wavelength. We have used this OPA transmitter to make measurements of CH4 at various pressures in a gas cell and over open outdoor horizontal paths. We have measured the lineshape of methane in a 6 cm long cell at various energy levels with this transmitter, with excellent agreement with the lineshape calculated by HITRAN. We have also measured the absorption lineshape of atmospheric methane in an open 3 km outdoor path. The agreement between the measurements and HITRAN, for 1746 ppb and 760 Torr was quite good. We have also made pulsed two wavelength lidar measurements of methane line absorption in the column to a tower at 1.5 km range. These used on- and off-line wavelengths of 1650.957 nm, and 1651.072 nm, and a 20 cm diameter receiver telescope with an infrared PMT detector. The absorption of the on-line photons was 30%. The methane column absorption was estimated via HITRAN, and was in good agreement with the expected methane absorption for a concentration of 1750 ppm. Finally we have calculated the measurement performance of an airborne methane lidar using this transmitter, as well as the energy and telescope scaling needed for a lidar for space. These results, and more details of our experiments will be described in the presentation.

Riris, Haris↗

Development of Mesospheric Sodium Laser Beacon for Atmospheric Adaptive Optics

A solid-state source of long pulse length, sodium-resonance radiation was developed for the purpose of generating an artificial star in the earth's mesospheric sodium layer. This radiation is generated by sum-frequency mixing the output of a 1.064 micron Nd:YAG laser with the output of a 1.319-micron Nd:YAG laser. By operating these lasers at wavelengths very close to the peak of their tuning curves, it is possible to match the wavelength of the sum-frequency radiation to that of the sodium D2 adsorption wavelength. Two pulsed laser systems were constructed, one producing as much as 0.6 J of sodium resonance radiation at a 10-Hz repetition rate and another producing as much as 24 mJ at a 840-Hz repetition rate. In both laser systems, the 1.06-micron and 1.32-micron Nd:YAG lasers are configured as mode-locked master oscillators followed by power amplifiers. Other aspects of this project are presented.

Jeys, T. H.↗

Performance of A Real-Time Photon Counting Optical Receiver in the Presence of Emulated Channel Fading

Free-space optical communication links with terrestrial ground stations experience fading due to atmospheric scintillation and beam pointing. Fiber-coupled receiver systems experience additional fading at the interface between the fiber and free-space optics of the telescope. The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has characterized a real-time photon-counting optical ground receiver system with an atmospheric fade emulation system. The receiver system is comprised of a fiber interconnect, an array of superconducting nanowire single photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Two fiber interconnect/detector architectures have been studied. One architecture uses a 70-mode photonic lantern coupled to seven single pixel SNSPDs. The other architecture uses a 10-mode few-mode fiber (FMF) coupled to a 15-pixel SNSPD array. The receiver system complies with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency Coding and Synchronization Standard, which uses serially concatenated convolutionally coded pulse-position modulation (SCPPM). The CCSDS standard is designed for use in low photon flux missions, including the Orion Artemis-II Optical (O2O) communications demonstration. The standard utilizes a convolutional symbol interleaver which can be resized to mitigate different fades. The fade emulation system employed in this work emulates scintillation-induced, pointing-induced, and coupling-induced fading. This paper gives an overview of the real-time optical receiver system and the fade emulation system. It presents tests results which show the impact of fading on the performance on the receiver. The test results show that in the presence of channel fading, the 70-mode photonic lantern outperforms the 10-mode FMF under higher (D/r_0=9) turbulence conditions due to high fiber-coupling-induced fading and fiber coupling loss on the 10-mode FMF. When operating in lower turbulence (D/r_0=4), the 10-mode FMF outperforms the 70-mode photonic lantern. The paper also shows a larger convolutional interleaver improves the system performance as long as the receiver does not lose acquisition.

optical communications↗

Performance of a real-time photon counting optical receiver in the presence of emulated channel fading

Free-space optical communication links with terrestrial ground stations experience fading due to atmospheric scintillation and beam pointing. Fiber-coupled receiver systems experience additional fading at the interface between the fiber and free-space optics of the telescope. The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has characterized a real-time photon-counting optical ground receiver system with an atmospheric fade emulation system. The receiver system is comprised of a fiber interconnect, an array of superconducting nanowire single photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Two fiber interconnect/detector architectures have been studied. One architecture uses a 70-mode photonic lantern coupled to seven single pixel SNSPDs. The other architecture uses a 10-mode few-mode fiber (FMF) coupled to a 15-pixel SNSPD array. The receiver system complies with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency Coding and Synchronization Standard, which uses serially concatenated convolutionally coded pulse-position modulation (SCPPM). The CCSDS standard is designed for use in low photon flux missions, including the Orion Artemis-II Optical (O2O) communications demonstration. The standard utilizes a convolutional symbol interleaver which can be resized to mitigate different fades. The fade emulation system employed in this work emulates scintillation-induced, pointing-induced, and coupling-induced fading. This paper gives an overview of the real-time optical receiver system and the fade emulation system. It presents tests results which show the impact of fading on the performance on the receiver. The test results show that in the presence of channel fading, the 70-mode photonic lantern outperforms the 10-mode FMF under higher (D/r_0=9) turbulence conditions due to high fiber-coupling-induced fading and fiber coupling loss on the 10-mode FMF. When operating in lower turbulence (D/r_0=4), the 10-mode FMF outperforms the 70-mode photonic lantern. The paper also shows a larger convolutional interleaver improves the system performance as long as the receiver does not lose acquisition.

optical communications↗

Inductive Pulsed Plasma Thruster Development and Testing at NASA-MSFC

THE inductive pulsed plasma thruster (IPPT) is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged producing a high current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. In the present work, we present a summary of the IPPT research and development conducted at NASA's Marshall Space Flight Center (MSFC). As a higher-power, still relatively low readiness level system, there are many issues associated with the eventual deployment and use of the IPPT as a primary propulsion system on spacecraft that remain to be addressed. The present program aimed to fabricate and test hardware to explore how these issues could be addressed. The following specific areas were addressed within the program and will be discussed within this paper. a) Conical theta-pinch IPPT geometry thruster configuration. b) Repetition-rate multi-kW thruster pulsing. c) Long-lifetime pulsed gas valve. d) Fast pulsed gas valve driver and controller. e) High-voltage, repetitive capacitor charging power processing unit. During the course of testing, a number of specific tests were conducted, including several that, to our knowledge, have either never been previously conducted (such as multi-KW repetition-rate operation) or have not been performed since the early 1990s (direct IPPT thrust measurements).2 Conical theta-pinch IPPT thrust stand measurements are presented in Fig. 1 while various time-integrated and time

Polzin, Kurt A.↗

James Webb Space Telescope Mid Infra-Red Instrument Pulse-Tube Cryocooler Electronics

The latest generation of long life, space pulse-tube cryocoolers require electronics capable of controlling self-induced vibration down to a fraction of a newton and coldhead temperature with high accuracy down to a few kelvin. Other functions include engineering diagnostics, heater and valve control, telemetry and safety protection of the cryocooler subsystem against extreme environments and operational anomalies. The electronics are designed to survive the thermal, vibration, shock and radiation environment of launch and orbit, while providing a design life in excess of 10 years on-orbit. A number of our current generation high reliability radiation-hardened electronics units are in various stages of integration on several space flight payloads. This paper describes the features and performance of our latest flight electronics designed for the pulse-tube cryocooler that is the pre-cooler for a closed cycle Joule-Thomson cooler providing 6K cooling for the James Webb Space Telescope (JWST) Mid Infra-Red Instrument (MIRI). The electronics is capable of highly accurate temperature control over the temperature range from 4K to 15K. Self-induced vibration is controlled to low levels on all harmonics up to the 16th. A unique active power filter controls peak-to-peak reflected ripple current on the primary power bus to a very low level. The 9 kg unit is capable of delivering 360W continuous power to NGAS's 3-stage pulse-tube High-Capacity Cryocooler (HCC).

thermometry↗

Preliminary design for a Zero Gravity Test Facility (ZGTF). Volume 1: Technical

The functional requirements and best conceptual design of a test facility that simulates weightless operating conditions for a high gain antenna systems (HGAS), that will broadcast to the Tracking Data Relay Satellites were defined. The typical HGAS defined is mounted on a low Earth orbiting satellite, and consists of an antenna with a double gimbal pointing system mounted on a 13 foot long mast. Typically, the gimbals are driven by pulse modulated dc motors or stepper motors. These drivers produce torques on the mast, with jitter that excites the satellite and may cause disturbances to sensitive experiments. The dynamic properties of the antenna support structure (mast), including flexible mode characteristics were defined. The torque profile induced on the spacecraft by motion of the high gain antenna was estimated. Gain and phase margins of the servo control loop of the gimbal drive electronics was also verified.

Germain, A.↗

25-LBF GO2/GH2 space station thruster

Multiple 25-lbf oxygen/gaseous hydrogen thruster assemblies for the Space Station propulsion application were designed and fabricated by Rocketdyne and endurance tested at the NASA/Marshall Space Flight Center. The thrusters incorporate a regeneratively cooled thrust chamber with a nozzle area ratio of 30, a 12-element coaxial injector, an ignition system, and close-coupled propellant valves. The various thruster configurations comprised of mating different injectors and thrust chambers. Over 2 million lbf-sec of impulse was demonstrated at mixture ratios from 3 to 8.4 at vacuum conditions. A thruster was subjected to over 10,000 pulses during which minimum impulse bits of less than 0.5 lb/sec were repeatedly and reliably demonstrated. A total operating time of 25.6 hr was accumulated on the thruster assemblies with one 6.1-hr. continuous firing duration. The thrusters operated between a thrust range of 11.2 and 36.6 lbf. The test results indicate that all major technology issues for long-life gaseous oxygen/gaseous hydrogen thrusters for the Space Station application have been resolved.

Finden, L. E.↗

INPIStron switched pulsed power for dense plasma pinches

The inverse plasma switch INPIStron was employed for 10kJ/40kV capacitor bank discharge system to produce focused dense plasmas in hypocycloidal-pinch (HCP) devices. A single unit and an array of multiple HCP's were coupled as the load of the pulsed power circuit. The geometry and switching plasma dynamics were found advantageous and convenient for commutating the large current pulse from the low impedance transmission line to the low impedance plasma load. The pulse power system with a single unit HCP, the system A, was used for production of high temperature plasma focus and its diagnostics. The radially running down plasma dynamics, revealed in image converter photographs, could be simulated by a simple snow-plow model with a correction for plasma resistivity. The system B with an array of 8-HCP units which forms a long coaxial discharge chamber was used for pumping a Ti-sapphire laser. The intense UV emission from the plasma was frequency shifted with dye-solution jacket to match the absorption band of the Ti crystal laser near 500 nm. An untuned laser pulse energy of 0.6 J/pulse was obtained for 6.4 kJ/40 kV discharge, or near 103 times of the explosion limit of conventional flash lamps. For both systems the advantages of the INPIStron were well demonstrated: a single unit is sufficient for a large current (greater than 50 kA) without increasing the system impedance, highly reliable and long life operation and implied scalability for the high power ranges above I(sub peak) = 1 MA and V(sub hold) = 100 kV.