Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Occupant-driven end use load models for demand response and flexibility service participation of residential grid-interactive buildings

As demand response becomes increasingly used as a tool to support improved grid flexibility, it is important to consider that there are many potential types of energy end uses that may be used to support such flexibility. Residential appliances, often accounting for 30 % or more of residential energy use, are a currently untapped source of demand flexibility, particularly when aggregated together across homes. To date there has been very limited analysis of residential appliances for use as grid-interactive loads. As such, this research uses disaggregated energy end use data for 564 households, to model the electricity demand flexibility potential of the use of residential dishwashers, clothes washers, clothes dryers, ovens, and ranges (oven + stovetop) on both weekdays and weekends. This includes both at the building level, as well as aggregated to the grid level, specifically the Midcontinent Independent System Operator (MISO) region. This study was divided into two parts. Part 1 focuses on determining appliance-level loads, and Part 2, which involves aggregation to the grid. Findings suggest that among the studied appliances, clothes dryers provide the greatest demand reduction potential for most times of the day, followed by dishwashers and clothes washers. The maximum potential reduction for clothes dryers is found to be approximately at 11:00 a.m. and this potential sustains throughout most of the daytime period. When considering the willingness of households to participate, based on a survey of households in the Midwest region, clothes dryers still have the most potential for demand reduction. The availability of appliances for load modulation on weekdays and weekends indicates similar load reduction potential for all appliances. Overall, the results of this study suggest that there is an opportunity for shifting appliance usage to optimize grid efficiency and enhance demand response strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GPR Robotic Assisted Non-Destructive Evaluation of Concrete Structures - 20196

Reinforced concrete structures are always under exposure of internal or external deteriorations due to many factors such as environmental, nuclear radiation or even construction deficiencies. The use of nondestructive test is one of the reliable methods to inspect structural members. In this case, GPR has a good capability to detect inside deteriorations of concrete structures. However, in many cases it is hard to inspect structural members by hand due to safety issues or inaccessibility. Thus, an alternative way to reduce such risks is to employ robot to carry nondestructive equipment. In this research, twelve reinforced concrete RC beams (8 x 16 x 96, width, height and length) are cast in the lab. Three RC beams have no defect and nine others various defects such as corrosion, de-bonded bars, void, delamination and honeycombing. The one-point load is applied at the center of the RC beam. The loading level is carried out at three levels: 50%, 75% and 100% of maximum load and total load-displacement diagram are performed. The load is held at each level and the robotic GPR is used to scan the side of RC beams. Then, RADAN software is employed to find out any defects at different loading conditions and visualize the crack propagation. The RADAN results show that the pattern of crack propagation for corrosion and debonding are same. Also, the load-displacement results present that inside defect cause reduction of load-capacity of RC beam. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Airfoil leading edge blowing to control bow shock waves

Abstract This manuscript presents a detailed characterization of active control of bow shock waves via leading edge injection, including subsonic coolant ejection and the appearance of Coanda effects. The flow phenomena occurring at steady and pulsating flow injection regimes were analyzed using steady and unsteady two-dimensional Reynolds-Averaged Navier Stokes, leading to a precise evaluation of the thermal load and drag reductions. Steady supersonic injection yields the largest abatement in thermal load and aerodynamic drag, while subsonic or fluctuating ones can also provide significant improvements at reduced cooling mass flow rates. Furthermore, a Coanda effect, causing a non-symmetric flow topology, was observed and analyzed for reduced injection port size. This Coanda effect is due to the sudden expansion happening from the injection port to the main flow and it causes the flow topology at the leading edge to become non-symmetric despite the complete symmetry of the problem. This is the first time in the literature such a phenomenon is documented for a supersonic airfoil leading edge injection. Furthermore, it enables the design of novel flow control strategies for the leading edge shock topology and flow structures in supersonic flows.

42 ENGINEERING↗

Electrochemical Nutrient Recovery for the Food–Energy–Water Nexus at Municipal Wastewater Facilities: Multivariate Analyses of Seasonal Sampling and Reactor Performance

Digester-equipped municipal wastewater facilities generate recycle streams with high nutrient loads that increase energy consumption and can cause environmental pollution. The reduction of these loads through electrochemical nutrient recovery (ENR) could enhance the food–energy–water nexus by producing fertilizer (struvite). This study investigated the recovery process through a 1 year sampling of recycle streams and the implementation of nutrient recovery. Time series analyses showed that P (as orthophosphate) concentration was time-variant in digester effluent streams, while N (as ammonia) concentration was time-variant in only the aerobic system. Furthermore, these two nutrient concentrations did not correlate in any of the recycle streams. Subsequent multivariate screening analyses identified anode type, NH 4 + concentration, cathodic potential, P concentration, and temperature as most significant for ENR. Finally, the optimum conditions of cathodic potential, anode area-to-volume ratio, and temperature applied to a real recycle stream resulted in 95% P recovery with 0.03 kWh/kg P. This energy consumption is significantly lower than process energy for conventional P fertilizers (1.1 kWh/kg P) and chemical recovery processes at scale (1.7–12.9 kWh/kg P). Overall, this study recommended specific process controls for nutrient recovery, expanded the variables evaluated for ENR, and demonstrated the ability to significantly impact energy demand associated with P-based fertilizers.

36 MATERIALS SCIENCE↗

Reducing Commercial Building Process Loads and Refrigeration Unit Energy Consumption

This resource provides guidance on larger PPLs, many of which are hardwired. Examples include elevators, enterprise servers, freezers, and water fountains with chillers, which are often collectively referred to as "process loads." This resource also outlines how to assess process loads in a building, describes the procedure for identifying which loads to target for reduction, and provides an overview of reduction strategies. In this resource, process loads are broken into five categories - food handling, refrigeration, internal mobility, data center and information technology, and water handling.

commercial buildings↗

Heliostat Consortium: Gap Analysis on State of the Art in Wind Load Design

Wind loads are a major driver of heliostat cost. Standardized methods and tools are needed for a more detailed understanding of the static and dynamic loads of a heliostat design. This will enable cost reduction of wind-dependent heliostats to avoid unnecessarily conservative heliostat designs and increase field efficiency and reliability to reduce the risk of component failures due to high-wind events. Gaps related to wind load include lack of site characterization for wind measurements, insufficient critical load cases for heliostat design, insufficient understanding of turbulence impacts on heliostat tracking error, lack of knowledge on wind load under various heliostat array configurations, and underexplored heliostat field wind-load reduction and operating strategies. Recommended pathway forward is to develop wind load and site characterization guidelines for heliostat design and develop heliostat field wind-load models with optical performance impacts.

aerodynamics↗

Influence of Photovoltaic Shading on Rooftop Heat Transfer, Building Energy Loads, and Photovoltaic Power Output

Photovoltaic (PV) modules on building rooftops provide shade from summer heating, leading to a reduction in cooling load during hot seasons. However, PV shading also reduces passive solar heating during winter months, leading to an increase in the building heating load during cold seasons. In this study, the heat transfer performance of an enclosure formed by adjacent PV modules is analyzed for three locations in the United States, comparing the daily heat flux through rooftops for the case of a PV-shaded rooftop as well as an unshaded roof. Several result metrics are developed as part of this work, including the saved energy load (SEL), or the energy conserved by adding PV-shading to the rooftop, and the additional energy load (AEL), or the supplemental building energy required to replace shaded solar heating. Lastly, this work calculates the utility factor, being the ratio of SEL and PV power output to AEL as a metric of PV effectiveness. SELs are 5.2, 6.2, and 11.7 kWh/m 2 · year for Dayton, Boise, and Phoenix, respectively, while the AELs for the same locations are 1.6, 1.5, and 2.1 kWh/m 2 · year. The utility factors for the same three locations are 61, 71, and 79. In general, locations with hot, non-cloudy summers and clear skies in winter see the largest utility factor. Further, it is shown that PV shading can conserve building energy during the winter months by preventing radiative losses to cold winter skies.

13 HYDRO ENERGY↗

Field‐scale analysis of miscanthus production indicates climate change may increase the opportunity for water quality improvement in a key Iowa watershed

Abstract The Raccoon River Basin is the primary source for drinking water in Iowa's largest city and plays a major role in the Mississippi River Basin's high nutrient exports. Future climate change may have major impacts on the biological, physiological, and agronomic processes imposing a threat to ecosystem services. Efforts to reduce nitrogen (N) loads within this basin have included local litigation and the implementation of the Iowa Nutrient Reduction Strategy, which suggest incorporating bioenergy crops (i.e., miscanthus) within the current corn–soybean landscape to reach a 41% reduction in nitrate loads. This study focuses on simulating N export for historical and future land use scenarios by using an agroecosystem model (Agro‐IBIS) and a hydrology model (THMB) at the 500‐m resolution, similar to the scale of agricultural fields. Model simulations are driven by CMIP5 climate data for historical, mid‐century, and late‐century under the RCP 4.5 and 8.5 warming projections. Using recent crop profit analyses for the state of Iowa, profitability maps were generated and nitrogen leaching thresholds were used to determine where miscanthus should replace corn–soybean area to maximize reductions in N pollution. Our results show that miscanthus inclusion on low profit and high N leaching areas can result in a 4% reduction of N loss under current climate conditions and may reduce N loss by 21%–26% under future climate conditions, implying that water quality has the potential continue to improve under future climate conditions when strategically implemented conservation practices are included in future farm management plans.

54 ENVIRONMENTAL SCIENCES↗

Measuring Flexibility through Reduction Potential

As electrical loads, electric vehicles (EVs) are distinguished in many cases by their substantial flexibility. Harnessing this flexibility, however, requires a precise characterization of its timing and degree. Current approaches to flexibility characterization tend to be limited either by the complexity of their representation or their inability to capture aggregate flexibility across multiple vehicles. In this paper, we present the reduction potential matrix, a novel metric capturing fleet-level EV load flexibility while being both straightforward to calculate and intuitive to interpret. We use the metric to quantify flexibility for two operationally distinct commercial groups: freight vehicles and transit buses. While we find that both vehicle groups have substantial flexibility, its timing, magnitude, and duration varies across the groups. We describe how this variability translates into variation in the each group's role as a grid resource, and conclude with a discussion of how system planners, fleet operators, and other stakeholders can use the novel metric to cultivate symbiosis between vehicles and the grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Universal Solvent Viscosity Reduction via Hydrogen Bonding Disruptors

Liquid Ion Solutions LLC (DBA RoCo Global) in partnership with Carnegie Mellon University and Carbon Capture Scientific LLC, has performed lab-scale development and evaluation of novel additives that lower the viscosity of water-lean amine solvents for post-combustion carbon dioxide capture. This project focuses on developing additives that minimize the formation of long-range electrostatic and hydrogen bonding (HB) networks, decreasing the solvent viscosity, improving diffusion, and improving the process economics. The project objectives included: 1) performing computer simulation to understand the molecular interactions of the additive molecules in water-lean CO 2 capture solvents, 2) design and synthesis of HB disruptors additives, 3) performance testing with additive molecules on model amine solvents, and 4) demonstration of the effectiveness of the optimized additives in the presence of synthetic flue gas. To meet the abovementioned objectives, the project team utilized a holistic approach that combines molecular simulation, experimental testing, and economic analysis studies. The project team developed ab initio molecular model and then perform computer simulation to develop relationship between hydrogen bonding, viscosity, and performed quantitative analysis of additive on the viscosity of the solvent. The team completed computational comparative study on a range of organic functional groups such as ethers, esters, cyclic carbonates, alkanes, and ammonium salts for their effect on viscosity gaining key insights into molecular interactions and the impact of various functional groups and molecular shapes on viscosity. Assisted with molecular simulation insights, the project team conducted additive synthesis and testing, including a proof-of-concept study, additive screening, optimization, and synthetic flue gas testing. The experimental proof-of-concept study proved that the hydrogen bonding acceptors result in significant decrease of viscosities. Detailed additive screening (exploring various functionalities and molecular structures) has been performed. Several promising additives showed excellent reduction in viscosity (30-41%) at 5% additive loading, and over 50% viscosity reduction at 10% additive loading for the model solvents. The team also performed complex screening studies on additive loadings and mixing effect among additives using the design of experiments. Based on multiple screening experiments, one additive-solvent candidate was down-selected for synthetic flue gas testing. A 100-hour continuous absorption/desorption study was conducted under simulated flue gas using a lab-scale continuous capture and separation system. No degradation (for both solvent and additive) was observed based on the GC results of the solvent samples collected from the continuous study. The team conducted preliminary engineering analyses and cost-benefit analyses to quantify the potential economic benefits of the additive approach for solvent viscosity reduction. Based on the experimental data, CO 2 capture cost savings from the capital and operating cost savings are estimated at $\$$4.7/tonne and $\$$0.3/tonne CO 2 captured, respectively. Considering the additive cost, the net benefit is estimated to be between $\$$4.32~$\$$4.86/tonne CO 2 captured.

20 FOSSIL-FUELED POWER PLANTS↗

Utah FORGE: Fault Reactivation Through Fluid Injection Induced Seismicity Laboratory Experiments

Included are results from shear reactivation experiments on laboratory faults pre-loaded close to failure and reactivated by the injection of fluid into the fault. The sample comprises a single-inclined-fracture (SIF) transecting a cylindrical sample of Westerly granite. All experiments are conducted at ambient temperature and follow a similar protocol: (i) application of confining stresses (3MPa) on the fault fully saturated with DI water, (ii) shear-mobilization through the increase of axial loading at a constant displacement rate until a post-peak steady-state condition is reached, (iii) reduction of axial loading and related shear stress to a prescribed fraction of the peak steady-state frictional strength (typically 60% to 90%, representing intermediate to high magnitudes) and (iv), fault reactivation triggered by a stepwise increase of pore pressure on the fault in 0.1 MPa increments held constant for 1-5 minutes. Mechanical data from three ISCO pumps connected to a Temco pressure vessel measure axial, confining, and fault-related parameters, including fluid pressure (kPa), fluid flow rate (mL/min), and axial displacement (mm). See included code for initial data analysis and visualization for select experiments. Resource names represent experiment numbers found in the "Read Me" file, which describes each experimental setup and parameters.

15 GEOTHERMAL ENERGY↗

Analyzing the Impact of Future Weather Data on Energy Consumption in Weatherization Assistant

This study supports the mission of the U.S. Department of Energy’s Weatherization Assistance Program (WAP), which aims to increase the energy efficiency of dwellings and reduce their total residential expenditures. Specifically, we examine how projected future climate conditions may affect residential building energy performance by integrating future weather data into the National Energy Audit Tool (NEAT). Since WAP evaluates the cost-effectiveness of retrofit measures over lifespans of up to 30 years, accounting for evolving climate conditions is increasingly important. To reflect future household energy demands, this study replaces historically based Typical Meteorological Year (TMY3) weather inputs with Future Typical Meteorological Year (fTMY) datasets derived from global climate model (GCM) projections. A simulation-based framework was established to enable NEAT analysis under future weather conditions. This workflow involves converting EPW-format weather files into JSON inputs compatible with NEAT and generating degree-hour metrics needed for load calculations. The fTMY dataset used in this study was developed by Oak Ridge National Laboratory through downscaling of six GCMs under different emission scenarios and covers the period from 2020 to 2100. In contrast, the TMY3 dataset is based on historical weather data from 1961 to 1990. Simulations were conducted for benchmark single-family prototype buildings across ASHRAE climate zones 1–7, which cover all regions of the U.S. except the subarctic Zone 8 in northern Alaska, evaluating both heating and cooling loads under TMY3 and fTMY conditions. Four foundation types were tested, while heating systems were standardized, as NEAT does not differentiate thermal energy load by HVAC system type in its load calculations. Results show that fTMY weather input consistently yield lower heating loads and higher cooling loads across most locations, aligning with expected climate warming trends. Notably, colder regions such as zones 6A, 6B, and 7 experience marked reductions in heating load, while warmer and transitional zones, such as 2A (Lufkin, TX) and 3C (San Francisco, CA), have substantial increases in cooling loads. Although this study does not directly assess the performance of retrofit measures under future climate conditions, it provides a critical foundation for doing so. By quantifying shifts in baseline (i.e., pre-retrofit case) energy loads between historical and future weather files, the study highlights the importance of integrating climate-responsive data into audit tools. These findings will inform future efforts to evaluate the long-term effectiveness and cost-effectiveness of weatherization measures under changing climate conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Development of Low Weight, Titanium Aluminide Airfoils for High Performance Industrial Gas Turbines meeting 65% Combined Cycle Efficiency (Final Report)

This project funded under DOE-FOA-0001816 was performed with the intent of evaluating the potential of utilizing a low density, high specific strength Titanium Aluminide (TiAl) alloy in a large annulus last stage gas turbine blade with the intent of improving combined cycle gas turbine efficiency toward a goal of reaching 65% efficiency. The project consisted of identifying a potentially suitable TiAl material for manufacture of such a large blade by investment casting. This included estimation of design properties for the selected alloy, trade studies using a baseline design created for a nickel based alloy cast in the TiAl alloy to evaluate potential design changes required for the use of this material and optimization of a prototype design for the same baseline application using the selected TiAl alloy. Several rounds of optimization were completed with the intent of meeting the baseline design targets with a resulting design that showed at least equivalent performance in terms of creep, LCF/TMF, HCF and aerodynamic damping potential. While it was found that significant reductions in blade loading on the disk were possible, the design resulting from the optimization met most lifing targets at the baseline size, but showed a reduction in margins in some areas in comparison to the Ni-based baseline design. Additionally, it was found that the low strain tolerance of the TiAl alloy for temperatures at and below the operational temperature of the attachment resulted in marginal, although still acceptable, creep rupture performance of the design. Due to results indicating the reduced potential for increasing turbine annulus compared to expectations a Phase II award was not proposed and it is not recommended to pursue additional design optimization efforts until further material advances with TiAl materials are achieved.

03 NATURAL GAS↗

Ultralow platinum loading for redox-flow battery by electrospinning the electrocatalyst and the ionomer in core-shell fibers

Hydrogen Bromine Redox Flow Batteries (HBRFB) are promising candidates for large scale energy storage, having an excellent balance of system, inexpensive and abundant electrolytes, high power density and near zero kinetic limitations. However, they suffer from corrosion of the hydrogen electrode due to bromine species crossover, which requires a high loading of precious group metal (PGM) electrocatalyst. Herein, a standard catalyst has been used in an electrospun (ES) fiber mat electrode, allowing for a significant (six-fold) reduction in platinum loading from 0.3 mg Pt /cm 2 down to 0.05 mg Pt /cm 2 . At this very low loading, the electrospun electrode attained an impressive specific power of 11.5W/mg Pt , and exhibited excellent durability, with constant power output for 140 charge/discharge cycles. Further, the excellent performance of the electrospun hydrogen electrode is attribute to its unique core-shell nanofiber structure, which improves the stability of the catalyst by preventing bromide species from reaching the catalyst surface.

25 ENERGY STORAGE↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exergy Analysis of a Convective Heat Pump Dryer Integrated with a Membrane Energy Recovery Ventilator

To increase energy efficiency, heat pump dryers and membrane dryers have been proposed to replace conventional fossil fuel dryers. Both conventional and heat pump dryers require substantial energy for condensing and reheating, while “active” membrane systems require vacuum pumps that are insufficiently developed. Lower temperature dehumidification systems make efficient use of membrane energy recovery ventilators (MERVs) that do not need vacuum pumps, but their high heat losses and lack of vapor selectivity have prevented their use in industrial drying. In this work, we propose an insulating membrane energy recovery ventilator for moisture removal from drying exhaust air, thereby reducing sensible heat loss from the dehumidification process and reheating energy. The second law analysis of the proposed system is carried out and compared with a baseline convective heat pump dryer. Irreversibilities in each component under different ambient temperatures (5–35 °C) and relative humidity (5–95%) are identified. At an ambient temperature of 35 °C, the proposed system substantially reduces sensible heat loss (47–60%) in the dehumidification process, resulting in a large reduction in condenser load (45–50%) compared to the baseline system. The evaporator in the proposed system accounts for up to 59% less irreversibility than the baseline system. A maximum of 24.5% reduction in overall exergy input is also observed. The highest exergy efficiency of 10.2% is obtained at an ambient condition of 35 °C and 5% relative humidity, which is more than twice the efficiency of the baseline system under the same operating condition.

Balaraman, Anand (ORCID:0000000218355788)↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

Immunogenicity and protective efficacy of a rhesus adenoviral vaccine targeting conserved COVID-19 replication transcription complex

The COVID-19 pandemic marks the third coronavirus pandemic this century (SARS-CoV-1, MERS, SARS-CoV-2), emphasizing the need to identify and evaluate conserved immunogens for a pan-sarbecovirus vaccine. Here we investigate the potential utility of a T-cell vaccine strategy targeting conserved regions of the sarbecovirus proteome. We identified the most conserved regions of the sarbecovirus proteome as portions of the RNA-dependent RNA polymerase (RdRp) and Helicase proteins, both of which are part of the coronavirus replication transcription complex (RTC). Fitness constraints suggest that as SARS-CoV-2 continues to evolve these regions may better preserve cross-reactive potential of T-cell responses than Spike, Nucleocapsid, or Membrane proteins. We sought to determine if vaccine-elicited T-cell responses to the highly conserved regions of the RTC would reduce viral loads following challenge with SARS-CoV-2 in mice using a rhesus adenovirus serotype 52 (RhAd52) vector. The RhAd52.CoV.Consv vaccine generated robust cellular immunity in mice and led to significant reductions in viral loads in the nasal turbinates following challenge with a mouse-adapted SARS-CoV-2. These data suggest the potential utility of T-cell targeting of conserved regions for a pan-sarbecovirus vaccine.

60 APPLIED LIFE SCIENCES↗