Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Enhancement of Cognitive Processing by Multiple Sclerosis Patients Using Liquid Cooling Technology: A Case Study

Recent neuropsychological studies demonstrate that cognitive dysfunction is a common symptom in patients with multiple sclerosis. In many cases the presence of cognitive impairment affects the patient's daily activities to a greater extent than would be found due to their physical disability alone. Cognitive dysfunction can have a significant impact on the quality of life of both the patient and that of their primary caregiver. Two cognitively impaired male MS patients were given a visual discrimination task before and after a one hour cooling period. The subjects were presented a series of either red or blue circles or triangles. One of these combinations, or one fourth of the stimuli, was designated as the "target" presentation. EEG was recorded from 20 scalp electrodes using a Tracor Northern 7500 EEG/ERP system. Oral and ear temperatures were obtained and recorded manually every five minutes during the one hour cooling period. The EEG ERP signatures from each series of stimuli were analyzed in the energy density domain to determine the locus of neural activity at each EEG sampling time. The first subject's ear temperature did not decrease during the cooling period. It was actually elevated approximately 0.05 C by the end of the cooling period compared to his mean of control period value. In turn, Subject One's discrimination performance and cortical energy remained essentially the same after body cooling. In contrast, Subject Two's ear temperature decreased approx. 0.8 C during his cooling period. Subject Two's ERROR score decreased from 12 during the precooling control period to 2 after cooling. His ENERGY value increased approximately 300%, from a precooling value of approximately 200 to a postcooling value of nearly 600. These findings might be interpreted by the following three-part hypothesis: (1) the general cognitive impairment of MS patients may be a result of low or unfocused metabolic energy conversion in the cortex; (2) such differences show up most strongly in reduced energy in the occipital region during the initial processing of the precooling period visual stimulus which may indicate impaired early visual processing; and (3) increased postcooling activation in the le ft angular gyrus may result in enhanced higher-level reasoning related to processing visual task information. By this hypothesis the superior performance of Subject Two following body cooling may be a result of increased neural activation in his early visual recognition and processing centers.

Montgomery, Leslie D.↗

Select Variables Affecting Thermal System Design of a Liquid-Cooled Stator

NASA Glenn Researchers have endeavored to create a high-power-density, efficient electric motor called the High Efficiency Megawatt Motor (HEMM) with a goal of exceeding 98% efficiency and 1.46 MW of power. These aggressive goals were set because increasing the power density and efficiency of electric machines (motors and generators) is integral to bringing electrified aircraft (EA) to commercial realization. Resistive losses in the stator windings are by far the largest (34%) contributor to this design’s total energy losses. Previous testing of a HEMM-like stator test article (statorette) showed good agreement between measured performance and model predictions. Therefore, a foundation was provided to test other engineering parameters that are encountered when designing an electric machine. Of particular interest are the effects of changes to the thickness of the epoxy from the potting process, changes in the fluid volume/flow path around the end windings, and changes in the viscosity of the cooling fluid on the overall thermal performance of the unit. The impact of those parameters as revealed through a third-generation build, test, and finite element model analysis of a statorette test section is the focus of this paper.

EAP↗

Mixing-induced fluid destratification and ullage condensation

In many applications, on-orbit storage and transfer of cryogens will require forced mixing to control tank pressure without direct venting to space. During a no-vent transfer or during operation of a thermodynamic vent system in a cryogen storage tank, pressure control is achieved by circulating cool liquid to the liquid-vapor interface to condense some of the ullage vapor. To measure the pressure and temperature response rates in mixing-induced condensation, an experiment has been developed using Freon 11 to simulate the two-phase behavior of a cryogen. A thin layer at the liquid surface is heated to raise the tank pressure, and then a jet mixer is turned on to circulate the liquid, cool the surface, and reduce the pressure. Many nozzle configurations and flow rates are used. Tank pressure and the temperature profiles in the ullage and the liquid are measured. Initial data from this ground test are shown correlated with normal-gravity and drop-tower dye-mixing data. Pressure collapse times are comparable to the dye-mixing times, whereas the times needed for complete thermal mixing are much longer than the dye-mixing times.

Meserole, Jere S.↗

Microfabricated Liquid Rocket Motors

Under NASA Glenn Research Center sponsorship, MIT has developed the concept of micromachined, bipropellant, liquid rocket engines. This is potentially a breakthrough technology changing the cost-performance tradeoffs for small propulsion systems, enabling new applications, and redefining the meaning of the term low-cost-access-to-space. With this NASA support, a liquid-cooled, gaseous propellant version of the thrust chamber and nozzle was designed, built, and tested as a first step. DARPA is currently funding MIT to demonstrate turbopumps and controls. The work performed herein was the second year of a proposed three-year effort to develop the technology and demonstrate very high power density, regeneratively cooled, liquid bipropellant rocket engine thrust chamber and nozzles. When combined with the DARPA turbopumps and controls, this work would enable the design and demonstration of a complete rocket propulsion system. The original MIT-NASA concept used liquid oxygen-ethanol propellants. The military applications important to DARPA imply that storable liquid propellants are needed. Thus, MIT examined various storable propellant combinations including N2O4 and hydrazine, and H2O2 and various hydrocarbons. The latter are preferred since they do not have the toxicity of N2O4 and hydrazine. In reflection of the newfound interest in H2O2, it is once again in production and available commercially. A critical issue for the microrocket engine concept is cooling of the walls in a regenerative design. This is even more important at microscale than for large engines due to cube-square scaling considerations. Furthermore, the coolant behavior of rocket propellants has not been characterized at microscale. Therefore, MIT designed and constructed an apparatus expressly for this purpose. The report details measurements of two candidate microrocket fuels, JP-7 and JP-10.

Epstein, Alan H.↗

A comparison of three liquid-ventilation cooling garments during treadmill exercise

A comparative study was made of the heat transfer performance and physiological effects of three different cooling garments used under sealed garments (simulating space suits) on five male subjects, during treadmill exercise. The mean exercise metabolic rate while walking at 0.9 m/s (2 mph) was 464 plus or minus 33 W. An equilibrium condition was never reached during the uncooled suited control runs and the subjects lost approximately two percent of body weight during the exercises. The mean weight loss with an Apollo-type garment was 0.35 plus or minus 0.10 kg, and 0.26 plus or minus 0.11 kg with the full-body cooling patch garment (garment 2). With the partial-coverage cooling patch (garment 3), the weight loss was 0.52 plus or minus 0.12 kg. The data showed an increase in the leg blood flow when the working muscles were not cooled by liquid flow (garment 3), and the arm blood flow remained unchanged with and without liquid cooling to the arms.

Webbon, B.↗

Improved liquid film cooling concept.

Foamed liquid as potential coolants in rocket engine to overcome low efficiency and streaky coverage of conventional liquid film cooling

Burge, H. L.↗