Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Analytical and numerical studies of dark current in radiofrequency structures for short-pulse high-gradient acceleration

High-gradient acceleration is a key research area that could enable compact linear accelerators for future colliders, light sources, and other applications. In the pursuit of high-gradient operation, rf breakdown limits the attainable accelerating gradient in normal-conducting rf structures. Recent experiments at the Argonne Wakefield Accelerator suggest a promising approach: using short rf pulses with durations of a few nanoseconds. Experimental studies show that these 𝒪⁡(1⁢ ⁢ns) rf pulses can mitigate breakdown limitations, resulting in higher gradients. For example, an electric field of nearly 400 MV/m was achieved in an 𝑋-band photoemission gun driven by 6-ns-long rf pulses, with rapid rf conditioning and low dark current observed. Despite these promising results, the short-pulse regime remains an underexplored parameter space, and rf breakdown physics under nanosecond-long pulses requires further investigation. In this paper, we present analytical and numerical simulations of dark current dynamics in accelerating cavities operating in the short-pulse regime. We study breakdown-associated processes spanning different time scales, including field emission, multipacting, and plasma formation, using simulations of the 𝑋-band photogun cavities. The results reveal the advantages of using short rf pulses to reduce dark current and mitigate rf breakdown, offering a path toward a new class of compact accelerators with enhanced performance and reduced susceptibility to breakdown.

Linear accelerators↗

Theory of photoemission from cathodes with disordered surfaces

Linear-accelerator-based applications like x-ray free electron lasers, ultrafast electron diffraction, electron beam cooling, and energy recovery linacs use photoemission-based cathodes in photoinjectors for electron sources. Most of these photocathodes are typically grown as polycrystalline materials with disordered surfaces. In order to understand the mechanism of photoemission from such cathodes and completely exploit their photoemissive properties, it is important to develop a photoemission formalism that properly describes the subtleties of these cathodes. Here, the Dowell–Schmerge (D–S) model often used to describe the properties of such cathodes gives the correct trends for photoemission properties like the quantum efficiency (QE) and the mean transverse energy (MTE) for metals; however, it is based on several unphysical assumptions. In the present work, we use Spicer’s three-step photoemission formalism to develop a photoemission model that results in the same trends for QE and MTE as the D–S model without the need for any unphysical assumptions and is applicable to defective thin-film semiconductor cathodes along with metal cathodes. As an example, we apply our model to Cs 3 Sb thin films and show that their near-threshold QE and MTE performance is largely explained by the exponentially decaying defect density of states near the valence band maximum.

43 PARTICLE ACCELERATORS↗

Geant4 Simulations on Faraday Cup Design for PIP-II Laser Wire Scanner System

The Proton Improvement Plan-II (PIP-II) accelerator upgrade at Fermilab represents a groundbreaking leap forward in high-energy physics research. This ambitious initiative involves enhancing Fermilab's accelerator complexby replacing the current linear accelerator (linac) with awarm front end (WFE) capable of accelerating H- beamsup to 2.1 MeV. Subsequently, a superconducting linac further accelerates these beams up to 800 MeV. To preciselymeasure the transverse beam profile, a combination of traditional wire scanners at the WFE section and Laser wirescanners along the superconducting linac are planned forimplementation. This investigation is centered on refiningthe Faraday cup design for the PIP-II Laser wire scannersby utilizing GEANT4, a Monte Carlo simulation toolkit.Leveraging this method enables a comprehensive analysisof particle trajectories, energy deposition, secondary particle emission, backscattering, etc., facilitating optimizationthrough adjustments to cup geometries, materials, andplacement to maximize its efficacy in beam diagnostics.

43 PARTICLE ACCELERATORS↗

Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator

X-ray generators, producing radiation in MeV range, are a critical tool for radiography, non-destructive testing and security applications. Field operation of such source requires them to be hand-portable, autonomous and allow parameter adjustability. RF linear accelerators can serve as a flexible, reliable, and robust radiation generator alternative to dangerous radioisotopes and bulky betatrons that are currently used for field radiography if their size, weight, cost, and imaging performance are matched to these sources. Here, in this paper, we present the design and test results of a 2 MeV Ku-band electron linac for a hand-portable X-ray generator system for field radiography being developed by RadiaBeam. The dramatic scale of miniaturization and cost-reduction is achieved thanks to the implementation of innovative technologies such as air-cooled Ku-band air-traffic control magnetrons, a split accelerating structure fabrication technique, and solid-state Marx modulators. This paper presents the design of the first prototype of the accelerator, its operation from Li-Ion batteries, as well as high-power and beam measurements.

43 PARTICLE ACCELERATORS↗

Three-Dimensional Particle-in-Cell Analysis of Mechanical Design Tolerances of the Scorpius Injector With Warp

Here, this article examines the mechanical design tolerances for the Scorpius injector using a 3-D particle-in-cell (PIC) code. In order to meet its objective as a high-fidelity, multipulse flash X-ray source, the accelerator has requirements for the electron beam in order to minimize the spot size of the beam focused onto a foil target to create high fluence X-rays at energies greater than 10 MeV. The requirements for alignment of the cathode, anode beam pipe, focusing solenoids, and transport solenoids specified using Trak and AMBER are independently verified using a 3-D electrostatic/magnetostatic model of the Scorpius injector, including transverse magnetic field errors that arise from mechanical alignment errors. It is predicted that the injector will meet the performance requirements for radiographic operation and has a design margin to correct for potentially unforeseen operating conditions.

42 ENGINEERING↗

RPI LINAC refurbishment and upgrade project

The Electron Linear Accelerator at Rensselaer Polytechnic Institute (RPI) was constructed in the late 1950s and started operation in 1961 [1]. The facility was designed and used primarily for measurements of Nuclear Data (ND) with emphasis on the resonance energy region. As such it was designed to produce short pulses of neutrons (5-5000 ns) and equipped with detection stations at different neutron flight path distances from the source (15 m-250 m). When the LINAC started operation it was one of the most powerful accelerators in the world for high energy-resolution measurements in the resonance region. The original LINAC with some upgrades is still in operation but no longer provides world class capabilities for measurements with short pulses. In 2011 discussions between the RPI ND group, Naval Reactors, and the Nuclear Criticality Safety Program about the future of the LINAC concluded that maintaining the capability to perform world-class nuclear data measurements at RPI was desirable. To that end, it was decided to refurbish the facility and upgrade the accelerator capabilities to enable high accuracy measurement in the resonance region with narrow neutron pulse and high electron beam power. Located at a major US technical university, this project provides a needed US nuclear data capability for both research and education, and also includes external users and industrial applications.

43 PARTICLE ACCELERATORS↗

Development and Optimization of a Purification Process to Recover 99 Mo from Low-enriched Uranium

Supported by the DOE-NNSA Office of Material Management & Minimization (M3), a number of domestic entities are pursuing non-highly enriched uranium (non-HEU) production of 99 Mo. As the production technologies of 99Mo pivot toward low-enriched uranium (LEU) or molybdenum targets, new reaction channels and accelerators are being evaluated. Superconducting electron linear accelerators (LINACs) with high-Z converter targets can generate bremsstrahlung photons and neutron fluxes that are capable of inducing photonuclear reactions and LEU fission. A particular advantage of a LINAC is that it does not rely on HEU-fueled reactor cores (which are currently slated for LEU conversion) and can operate on an almost continuous basis. Regarding the chemical purification of 99 Mo from irradiated uranium targets under acidic digestion, there exists a procedure known as Cintichem or modifications thereof with respect to LEU (LEU Modified Cintichem process, LMC). The process relies on a number of selective precipitation steps and column chromatography to purify Mo. It is important to note that LMC prescribes the addition of stable Mo to carry 99 Mo on alpha benzoin oxime, which reduces the specific activity of 99 Mo. This is especially important for processing 99 Mo batches with lower activities (~33 Ci of 99 Mo per batch).

07 ISOTOPE AND RADIATION SOURCES↗

GEANT4 Simulations on Faraday Cup Design for PIP-II Laser Wire Scanner System

The PIP-II accelerator upgrade at Fermilab represents a groundbreaking leap forward in high-energy physics research. This ambitious initiative involves enhancing Fermilab's accelerator complex by replacing the current linear accelerator with a warm front end (WFE) capable of accelerating H- beams up to 2.1 MeV. Subsequently, a superconducting linac further accelerates these beams up to 800 MeV. To precisely measure the transverse beam profile, a combination of traditional wire scanners at the WFE section and Laser wire scanners along the superconducting linac are planned for implementation. This investigation centers on refining the Faraday cup design for the PIP-II Laser wire scanners by utilizing GEANT4, a Monte Carlo simulation toolkit. Leveraging this method enables a comprehensive analysis of particle trajectories, energy deposition, secondary electron emission, backscattering, etc., facilitating optimization through adjustments to cup geometries, materials, and placement to maximize its efficiency.

43 PARTICLE ACCELERATORS↗

Geant4-based Analysis of Faraday Cup Performance for PIP-II Laser Wire Scanner System

The Proton Improvement Plan-II (PIP-II) accelerator upgrade at Fermilab marks a significant advancement in high-energy physics research. This initiative aims to enhance Fermilab's accelerator complex by replacing the existing linear accelerator (linac) with a warm front end (WFE) capable of accelerating H- beams up to 2.1 MeV. Subsequently, a superconducting linac (SCL), that further accelerates these beams up to 800 MeV. To accurately measure the transverse beam profile, traditional wire scanners will be utilized in the WFE section, while Laser wire scanners will be implemented along the SCL. The Faraday cup for the Laser wire scanners has been designed using the GEANT4 simulation toolkit. This poster presents a detailed analysis of its performance along the SCL, focusing on electron absorption, secondary electron emission, backscattering, etc.

Wijethunga, S. A.K.↗

Accelerator commissioning and rare isotope identification at the Facility for Rare Isotope Beams

In 2008, Michigan State University was selected to establish the Facility for Rare Isotope Beams (FRIB). Construction of the FRIB accelerator was completed in January 2022. Phased accelerator commissioning with heavy ion beams started in 2017 with the normal-conducting ion source and radio-frequency quadrupole. In April 2021, the full FRIB driver linear accelerator (linac) was commissioned, with heavy ion beams accelerated to energies above 200 MeV/nucleon by 324 superconducting radiofrequency (SRF) resonators operating at 2 K and 4 K with liquid-helium cooling. Further, in preparation for high-power operation, a liquid lithium charge stripper was commissioned with heavy ion beams up to uranium-238, followed by the simultaneous acceleration of multiple-charge-state heavy ion beams to energies above 200 MeV/nucleon. In December 2021, selenium-84 was produced with the FRIB target using a krypton-86 primary beam, demonstrating FRIB’s capability for scientific discovery.

07 ISOTOPE AND RADIATION SOURCES↗