Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

BOREAS Level-3b Landsat TM Imagery: At-sensor Radiances in BSQ Format

For BOREAS, the level-3b Landsat TM data, along with the other remotely sensed images, were collected in order to provide spatially extensive information over the primary study areas. This information includes radiant energy, detailed land cover, and biophysical parameter maps such as FPAR and LAI. Although very similar in content to the level-3a Landsat TM products, the level-3b images were created to provide users with a directly usable at-sensor radiance image. Geographically, the level-3b images cover the BOREAS NSA and SSA. Temporally, the images cover the period of 22-Jun-1984 to 09-Jul-1996. The images are available in binary, image format files.

Hall, Forrest G.↗

Low volume packaging for a microinstrumentation system

A folding, multi-platform assembly has been developed for the packaging of a multi-chip microinstrumentation system. The assembly includes three solid platforms connected by flexible micromachined ribbon cables and it can be populated by sensors and electronics from a variety of technologies including surface mount and integrated circuit (IC) processes. The entire structure is fabricated from a four-inch silicon wafer using a simple four mask process and a post-process EDP etch. The micromachined ribbon cables allow the platform assembly to be folded into a three level structure with control electronics on the bottom level, microsensors and interface electronics on the second level, and sensors that need environmental access on the top level. Using the silicon multi-platform assembly, a prototype microinstrumentation system has been developed that includes a microcontroller unit and sensors for measuring temperature, barometric pressure, humidity, altitude, and acceleration as well as a telemetry device for wireless communication. When folded in the three level structure, this microsystem occupies only 5 cc and can be placed in an outer case the size of a wristwatch.

Mason, A.↗

Measurements of upper atmosphere water vapor made in situ with a new moisture sensor

A new thin-film aluminum oxide sensor, Aquamax II, has been developed for the measurement of stratospheric and upper tropospheric water vapor levels. The sensor is briefly described with attention given to its calibration and performance. Data obtained from six balloon flights are presented; almost all the results show a constant water vapor mixing ratio, in agreement with other data from midlatitude regions.

Chleck, D.↗

STS-114: Discovery Post MMT Press Conference

Bruce Buckingham from NASA Public Affairs introduces the panel who consists of: Wayne Hale, Space Shuttle Program Deputy Manager; John Muratore, Manager, Space Shuttle Systems and Integration; and Mike Wetmore, Director of Shuttle Processing. Hale begins with a video presentation of the point sensor box (black box) and discusses the troubleshooting plans that are in place to fix the low level fuel sensor inside the External Tank of the Space Shuttle Discovery. Muratore talks about exploring conditions that may be causing the problem and Wetmore discusses completing scrub securing. Questions from the news media pertaining to solutions to the sensor problem, risks involved, and anomalies are addressed.

Source record↗

Specific failure identification algorithms for the F-8

Analytical redundancy is applied to the pitch axis of an aircraft to enhance sensor fault detection. Three different designs based on monitoring Kalman filter residuals or likelihood functions were developed. Sensor failures were simulated to evaluate the performance of the algorithms on a nonlinear simulation of an F-8C aircraft. Based on requirements for sensor fault detection and preliminary simulator performance it is concluded that these algorithms have the potential for reducing the level of sensor redundancy in a digital flight control system without compromising performance.

Hartmann, G. L.↗

Advanced detection, isolation and accommodation of sensor failures: Real-time evaluation

The objective of the Advanced Detection, Isolation, and Accommodation (ADIA) Program is to improve the overall demonstrated reliability of digital electronic control systems for turbine engines by using analytical redundacy to detect sensor failures. The results of a real time hybrid computer evaluation of the ADIA algorithm are presented. Minimum detectable levels of sensor failures for an F100 engine control system are determined. Also included are details about the microprocessor implementation of the algorithm as well as a description of the algorithm itself.

Merrill, Walter C.↗

Advanced detection, isolation, and accommodation of sensor failures - Real-time evaluation

The objective of the Advanced Detection, Isolation, and Accommodation (ADIA) program is to improve the overall demonstrated reliability of digital electronic control systems for turbine engines by using analytical redundancy to detect sensor failures. The results of a real-time hybrid computer evaluation of the ADIA algorithm are presented. Minimum detectable levels of sensor failures for an F100 engine control system are determined. Also included are details about the microprocessor implementation of the algorithm as well as a description of the algorithm itself.

Merrill, Walter C.↗

Ten Years of VIIRS On-Orbit Geolocation Calibration and Performance

The first innovative Visible Infrared Imaging Radiometer Suite (VIIRS) sensor aboard the Suomi National Polar-orbiting Partnership (SNPP) satellite has been in operation for 10 years since its launch on 28 October 2011. The second VIIRS sensor aboard the first Join Polar Satellite System (JPSS-1) satellite has been in operation for 4 years since its launch on 18 November 2017, which became NOAA-20. Well-geolocated and radiometrically calibrated Level-1 sensor data records (SDRs) from VIIRS are crucial to numerical weather prediction (NWP) and Level-2+ environmental data record (EDR) algorithms and products. The high quality of Level-2+ EDRs is a requirement for the continuity of NASA Earth science data records (ESDRs) and climate data records (CDRs), one of the two objectives of the SNPP mission and one of the three elements in the JPSS mission objective. The other objective of the SNPP mission is risk reduction for the follow-on JPSS missions. This paper summarizes the on-orbit geolocation calibration and validation (Cal/Val) activities for both VIIRS sensors onboard SNPP and NOAA-20 in the past 10 years. These activities include nominal geolocation Cal/Val activities, risk reduction activities, and improvements for the on-orbit VIIRS sensor operations. After these activities, sub-pixel geolocation accuracy is achieved. Nadir equivalent geolocation uncertainty is generally within 75 m (1-σ), or 20% imagery band pixels, in either the along-scan or along-track direction for both SNPP and NOAA-20 VIIRS sensors. The worst 16-day measured geolocation errors (radial, 3-σ) are 280 m and 267 m, respectively, in the latest SNPP and NOAA-20 VIIRS data collections, which are better than the required accuracy of 375 m (radial, 3-σ). The risk reduction activities also improved VIIRS builds for JPSS-3 and JPSS-4 satellites, and provide lessons learned for other VIIRS-like sensor builds.

VIIRS↗

Full-scale engine demonstration of an advanced sensor failure detection, isolation and accommodation algorithm: Preliminary results

The objective of the advanced detection, isolation, and accommodation (ADIA) program is to improve the overall demonstrated reliability of digital electronic control systems for turbine engines. For this purpose, algorithms were developed which detect, isolate, and accommodate sensor failures using analytical redundancy. Preliminary results of a full scale engine demonstration of the ADIA algorithm are presented. Minimum detectable levels of sensor failures for an F100 turbofan engine control system are determined and compared to those obtained during a previous evaluation of this algorithm using a real-time hybrid computer simulation of the engine.

Merrill, Walter C.↗

Full-scale engine demonstration of an advanced sensor failure detection isolation, and accommodation algorithm - Preliminary results

The objective of the advanced detection, isolation, and accommodation (ADIA) program is to improve the overall demonstrated reliability of digital electronic control systems for turbine engines. For this purpose, algorithms were developed which detect, isolate, and accommodate sensor failures using analytical redundancy. Preliminary results of a full scale engine demonstration of the ADIA algorithm are presented. Minimum detectable levels of sensor failures for an F100 turbofan engine control system are determined and compared to those obtained during a previous evaluation of this algorithm using a real-time hybrid computer simulation of the engine.

Merrill, Walter C.↗

A densely spaced array of sea level monitors for the detection of vertical crustal deformation in the Shumagin seismic gap, Alaska

A network of sea level gauges has been installed with about 40 km spacing in the Shumagin Islands in order to detect relative vertical motion, in particular, possible crustal motion precursory to an expected major earthquake. This required the development and deployment of a pressure sensor sea level gauge suitable for installation on remote and harsh coastlines. Data are collected in near-real-time via satellite, both in order to exploit fully any precursors that may be observed and to provide continuous information on the status of the instruments. Using Wiener filtering techniques, it has been determined conservatively that no relative vertical crustal motion greater than 0.1 m between stations has occurred during 1981-1985. This is consistent with independent geodetic leveling and trilateration data, though evidence exists for more rapid deformation during 1978-1980. The sea level data collected so far have an rms noise level of about 0.04 m after processing; this is limited in part by the pressure sensor and associated electronics. Improved prressure gauges with better long-term stability have recently been installed. A short-baseline tiltmeter operating in a tunnel has demonstrated that suitably designed and located land-based tiltmeters have a lower noise level, and hence better precursor detection characteristics than the sea level gauges, at monthly and shorter periods.

Beavan, John↗

Assessment of MODIS Scan Mirror Reflectance Changes On-Orbit

Since launch, the NASA EOS Terra and Aqua MODIS have operated successfully for more than 8 and 6 years, respectively. MODIS collects data using a two-sided scan mirror over a large scan angular range. The scan mirror is made of a polished, nickel-plated beryllium base coated with high purity silver, which is then over-coated with the Denton proprietary silicon monoxide and silicon dioxide mixture. The scan mirror's reflectance was characterized pre-launch using its witness samples, and the response versus scan angle was measured at the sensor system level. In this study, we present an assessment of MODIS scan mirror on-orbit degradation by examining changes of spectral band response over each sensor's mission lifetime. Results show that the scan mirror's optical properties for both Terra and Aqua MODIS have experienced significant degradation since launch in the VIS spectral region, which is mirror side dependent as well as scan angle dependent. In general, the mirror degradation is more severe for Terra MODIS than Aqua MODIS, especially during recent years. For Terra MODIS, the degradation rate is noticeably different between the mirror sides. On the other hand, there has been little mirror side dependent difference for Aqua MODIS.

Xiong, Xiaoxiong↗

Generalized parity relations for large space structures with uncertain parameters

The generalized parity relations method is a technique that can be used to detect sensor and actuator failures on a large space structure. A model of a grid structure was used to evaluate the performance of these relations. It shows their relative sensitivity to modeling errors. A method using sensor outputs and actuator inputs is required for the design of the generalized parity relations. Three different estimators are studied. The last estimator can generate relations optimized for the detection of a particular failure which are interesting when the level of sensor noise is high.

Dutilloy, J. R.↗

Turbofan engine demonstration of sensor failure detection

In the paper, the results of a full-scale engine demonstration of a sensor failure detection algorithm are presented. The algorithm detects, isolates, and accommodates sensor failures using analytical redundancy. The experimental hardware, including the F100 engine, is described. Demonstration results were obtained over a large portion of a typical flight envelope for the F100 engine. They include both subsonic and supersonic conditions at both medium and full, nonafter burning, power. Estimated accuracy, minimum detectable levels of sensor failures, and failure accommodation performance for an F100 turbofan engine control system are discussed.

Merrill, Walter C.↗

Experiments on active isolation using distributed PVDF error sensors

A control system based on a two-channel narrow-band LMS algorithm is used to isolate periodic vibration at low frequencies on a structure composed of a rigid top plate mounted on a flexible receiving plate. The control performance of distributed PVDF error sensors and accelerometer point sensors is compared. For both sensors, high levels of global reduction, up to 32 dB, have been obtained. It is found that, by driving the PVDF strip output voltage to zero, the controller may force the structure to vibrate so that the integration of the strain under the length of the PVDF strip is zero. This ability of the PVDF sensors to act as spatial filters is especially relevant in active control of sound radiation. It is concluded that the PVDF sensors are flexible, nonfragile, and inexpensive and can be used as strain sensors for active control applications of vibration isolation and sound radiation.

Lefebvre, S.↗

Distributed optical proximity sensor system - HexEYE

A novel optical proximity sensor system, capable of measuring the distance to the orientation and the discontinuity at a local area of an object surface, was designed and evaluated for robotic applications. The sensor system gets its name, Hexagonal Eye, (HexEYE) from its shape where seven identical hexagonal sensing units were configured hexagonally into a compact geometric structure. The seven sensing units were grouped into multiple combinations of three sensing units to measure the surface orientation as well as surface discontinuity. The distinctive features of HexEYE are an order of magnitude increased in distance sensitivity by optimizing the curvature of a conical mirror, the enhanced measurement accuracy based on multiple levels of sensor fusion, and the compactness in size due to a sensing mechanism based on the Gaussian lens law. A prototype of single sensing unit has been built and was evaluated experimentally.

Lee, Sukhan↗

Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

Arkin, C.↗

Sensor noise in low-level flux-gate magnetometers.

The noise mechanism in a well-designed magnetometer is shown to be due to small-scale magnetic moments which are probably small volumes of the core material that are not oriented by the drive field. Design developments include the sense coil radius and the development of a drive waveform which yields considerably improved performance over the commonly used sine wave drive.

Scouten, D. C.↗