241-AY-102 Leak detection pit drain line visual inspection - 15678

In October 2012, Washington River Protection Solutions LLC (WRPS) determined that waste had leaked into the annulus of Tank 241-AY-102. WRPS conducted an extensive review of Tank AY-102 and increased both inspection and monitoring of the tank; however, the precise cause and location of the leak could not be determined. In parallel with the leak in the primary tank, the Tank AY-102 leak detection pit (LDP) was accumulating water through the drain system external to the secondary tank liner. Liquid collecting in the LDP is suspected to be from water intrusion and collects at a rate such that the LDP must be pumped routinely. Following a routine pumping event on June 20, 2013, elevated radiation dose rates were noted on the transfer hose and surface contamination readings were found on the transfer pump when it was removed from the Tank AY-102 LDP. These two field readings suggested that tank waste from a secondary liner breach could be leaking into the LDP. As a result, WRPS initiated a plan to ascertain the integrity of the secondary tank liner including a robotic inspection of the LDP. To perform the robotic visual inspection, a custom robotic crawler with a deployment device was designed, built, and operated by IHI Southwest for WRPS to inspect the 6 in (152 mm) leak detection pit drain line. To ensure success when deployed in the field, the inspection equipment was demonstrated at both the IHI facility in Denver, Colorado, and the Hanford Site using full scale piping mockups. On November 20, 2013 WRPS inspected the 6 in (152 mm) diameter drain line. The deployment device successfully attached to the drain line, and the crawler entered the drain line and traversed to within approximately 7 ft (2.1 m) of the central sump located under the center of the tank before losing traction. Crawler performance was satisfactory, and the quality of the camera image and lighting provided sufficient detail to document the current condition of the visible regions of the pipe. The inspection showed that the majority of the drain line was dry. Two wet areas were observed, a portion of the line nearest the LDP and a portion near the center of the tank. The portion nearest the LDP was under water prior to pumping on November 14, 2013. Although sediment and debris were seen during the inspection, it is believed to be construction debris and corrosion products. No material was found in the inspection that looked like tank waste or the material seen in the Tank AY-102 annulus (i.e., no greenish or yellowish deposits or dark fluids, dried salt deposits, or crystalline material). The contamination levels seen on the crawler were consistent with past values seen on LDP pumping equipment. Sampling and analysis of the recovered residues from the crawlers did not find material consistent with tank waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Percutaneous Therapy of Ureteral Obstructions and Leak After Renal Transplantation: Long-Term Results

The purpose of this study was to evaluate the long-term outcome of percutaneous therapy of ureteral complications after renal transplantation. Between January 2000 and June 2006 we percutaneously treated 26 renal transplant patients with ureteral obstruction (n=19) and leak (n=7). Obstructions were classified as early (<2 months after transplantation) or late (>2 months). Patients with leak were treated with nephro-ureteral catheter placement and subsequent double-J stenting. Balloon dilatation, stent placement, and basket extraction were used to treat ureteral obstructions. Patients were followed with ultrasonography. No major procedure-related complication occurred. The mean follow-up time was 34.3 months (range: 6 to 74 months). Initial clinical success was achieved in all 19 patients with obstruction and 6 of 7 patients with leak. Four of 9 early obstructions and 4 of 10 late obstructions recurred during the follow-up. All recurrences were initially managed again with percutaneous methods, including cutting balloon technique and metallic stent placement. Although there was no recurrence in patients with successfully treated leak, stricture was seen at the previous leak site in two patients. These strictures were also successfully managed percutaneously. We conclude that in the treatment of ureteral obstruction and leak following renal transplantation, percutaneous therapy is an effective alternative to surgery. However, further interventions are usually needed to maintain long-term patency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Covered Biodegradable Stent: New Therapeutic Option for the Management of Esophageal Perforation or Anastomotic Leak

Purpose: This study was designed to evaluate our experience with the treatment of postoperative anastomotic leaks and benign esophageal perforations with covered biodegradable stents. Materials and Methods: From 2008 to 2010, we treated five men with either an anastomotic leak or benign esophageal perforation by implanting of covered biodegradable Ella-BD stents. The average age of the patients was 60 (range, 38-74) years. Postoperative anastomotic leaks were treated in four patients (1 after esophagectomy, 1 after resection of diverticulum, 2 after gastrectomy). In one patient, perforation occurred as a complication of the treatment of an esophageal rupture (which occurred during a balloon dilatation of benign stenosis) with a metallic stent. Results: Seven covered biodegradable stents were implanted in five patients. Primary technical success was 100%. Clinical success (leak sealing) was achieved in four of the five patients (80%). Stent migration occurred in three patients. In two of these patients, the leak had been sealed by the time of stent migration, therefore no reintervention was necessary. In one patient an additional stent had to be implanted. Conclusion: The use of biodegradable covered stents for the treatment of anastomotic leaks or esophageal perforations is technically feasible and safe. The initial results are promising; however, larger number of patients will be required to evaluate the capability of these biodegradable stents in the future. The use of biodegradable material for coverage of the stent is essential.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lymphatic Leak Occurring After Surgical Lymph Node Dissection: A Preliminary Study Assessing the Feasibility and Outcome of Lymphatic Embolization

PurposeTo analyze imaging findings of lymphatic leakage associated with surgical lymph node dissection on lymphangiography and assess the outcome of lymphatic embolization.Materials and MethodsThis retrospective study comprised 21 consecutive patients who were referred for lymphatic intervention between March 2014 and April 2015 due to postsurgical lymphatic leaks. Lymphangiography was performed through inguinal lymph nodes to identify the leak. When a leak was found, lymphatic embolization was performed by fine-needle injection of N-butyl cyanoacrylate into the site of leakage or into an inflow lymphatic vessel or into a pelvic lymph node located below the leakage. Electronic medical records and imaging studies were reviewed to assess the outcome.ResultLymphangiography revealed single or multiple leaks in all but one patient. Lymphatic embolization was performed in 20 patients with leaks. Including the patient who did not undergo embolization, 17 patients (81.0 %) showed initial response to treatment. Three patients underwent repeated embolization with successful results. The overall success rate was 95.2 %. The mean duration of hospitalization after lymphatic intervention was 5.9 days. During a mean follow-up period of 11 months, two patients developed localized swelling in the groin following lipiodol injection. There were no complications related to lymphatic embolization. Three patients were found to have developed small, asymptomatic lymphoceles on CT or MRI that did not require further treatment.ConclusionLymphangiography is useful for detecting lymphatic leakage occurring after lymph node dissection. Furthermore, lymphatic embolization is feasible, effective, and safe for managing leaks demonstrated on lymphangiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methane Leaks from Natural Gas Systems Follow Extreme Distributions

Future energy systems may rely on natural gas as a low-cost fuel to support variable renewable power. However, leaking natural gas causes climate damage because methane (CH 4 ) has a high global warming potential. In this study, we use extreme-value theory to explore the distribution of natural gas leak sizes. By analyzing ~15,000 measurements from 18 prior studies, we show that all available natural gas leakage datasets are statistically heavy-tailed, and that gas leaks are more extremely distributed than other natural and social phenomena. A unifying result is that the largest 5% of leaks typically contribute over 50% of the total leakage volume. While prior studies used lognormal model distributions, we show that lognormal functions poorly represent tail behavior. Our results suggest that published uncertainty ranges of CH 4 emissions are too narrow, and that larger sample sizes are required in future studies to achieve targeted confidence intervals. Additionally, we find that cross-study aggregation of datasets to increase sample size is not recommended due to apparent deviation between sampled populations. Finally, understanding the nature of leak distributions can improve emission estimates, better illustrate their uncertainty, allow prioritization of source categories, and improve sampling design. Also, these data can be used for more effective design of leak detection technologies.

03 NATURAL GAS↗

Distributed wireless sensing for fugitive methane leak detection

Large scale environmental monitoring requires dynamic optimization of data transmission, power management, and distribution of the computational load. In this work, we demonstrate the use of a wireless sensor network for detection of chemical leaks on gas oil well pads. The sensor network consist of chemi-resistive and wind sensors and aggregates all the data and transmits it to the cloud for further analytics processing. The sensor network data is integrated with an inversion model to identify leak location and quantify leak rates. We characterize the sensitivity and accuracy of such system under multiple well controlled methane release experiments. It is demonstrated that even 1 hour measurement with 10 sensors localizes leaks within 1 m and determines leak rate with an accuracy of 40%. This integrated sensing and analytics solution is currently refined to be a robust system for long term remote monitoring of methane leaks, generation of alarms, and tracking regulatory compliance.

04 OIL SHALES AND TAR SANDS↗

Chokes For Leak Testing High Pressure Systems

The purpose of this note is to describe the operation and use of a gas flow choke for leak detection. Newly installed vacuum systems and systems that experience a component failure, commonly have leaks which are above the highest test range of current helium mass spectrometer leak detectors, but below the detection range of sonic leak detectors. In many cases of new construction or maintenance large leaks are part of the initial testing of the vacuum system. The use of a gas flow choke will allow the operation of a leak detector at a much higher pressure.

43 PARTICLE ACCELERATORS↗

Model 9975 O Ring Fixture LongTerm Leak Performance (FY2021 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 19 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 9.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 11.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 26 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗

Superfluid helium leak sealant study

Twenty-one leak specimens were fabricated in the ends of stainless steel and aluminum tubes. Eighteen of these tubes were coated with a copolymer material to seal the leak. The other three specimens were left uncoated and served as control specimens. All 21 tubes were cold shocked in liquid helium 50 times and then the leak rate was measured while the tubes were submerged in superfluid helium at 1.7 K. During the cold shocks two of the coated specimens were mechanically damaged and eliminated from the test program. Of the remaining 16 coated specimens one suffered a total coating failure and resulting high leak rate. Another three of the coated specimens suffered partial coating failures. The leak rates of the uncoated specimens were also measured and reported. The significance of various leak rates is discussed in view of the infrared astronomical satellite (IRAS) Dewar performance.

Vorreiter, J. W.↗

Viscous flow effects on hydrogen leaks from cracks in the Orbiter Challenger main engines

An analytical model was developed to provide additional insight and understanding of the factors that influence the simulation and prediction of leak rates from small cracks in pressurized containers. Specifically, the analysis was aimed at developing an analytical model capable of predicting the hydrogen leak rates from a crack in the combustion chamber coolant discharge manifold on main engine 1 of the Orbiter Challenger that was discovered during flight readiness firings 1 and 2. This model was based on viscous pipe flow analyses and calibrated for the crack geometry by using helium leak-rate data obtained from both low- and high-pressure tests used to simulate the flight readiness firing test conditions. In addition, this model includes the effects of crack width changes caused by different working stresses associated with the different test conditions. Because of the combination of the small crack dimensions and the wide range of pressures used for the test conditions, either laminar or turbulent viscous effects dominated the flows at all test conditions. This model was used to illustrate the sensitivity of the predicted leak rates to considerations of test conditions, viscous flow effects, and geometric features of the crack. In addition, the model was certified by comparing the hydrogen leak-rate prediction for the flight readiness firing test condition to the actual measured leak rate. The prediction was within 9 percent of the measured value.

Goodrich, W. D.↗

Hazardous Gas Leak Analysis in the Space Shuttle

Helium tests of the main propulsion system in the Space Shuttle and on hydrogen leaks are examined. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers (MS) to monitor the shuttle environment for leaks. The mass spectrometers are fed by long tubes to sample gas from the payload bay, mid-body, aft engine compartment, and external tank. The purpose is to improve the HGDS, especially in its potential for locating cryogen leaks. Pre-existing leak data was analyzed for transient information to determine if the leak location could be pinpointed from test data. A rapid response leak detection experiment was designed, built, and tested. Large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MS was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MS data. One conclusion is that the backup HGDS sampling frequency should be increased above the present rate of 1 sample per second.

Barile, Ronald G.↗

A Hydrogen Leak Detection System for Aerospace and Commercial Applications

Leaks on the space shuttle while on the launch pad have generated interest in hydrogen leak monitoring technology. Microfabricated hydrogen sensors are being fabricated at Case Western Reserve University (CWRU) and tested at NASA Lewis Research Center (LeRC). These sensors have been integrated into hardware and software designed by Aerojet. This complete system allows for multipoint leak monitoring designed to provide leak source and magnitude information in real time. The monitoring system processes data from the hydrogen sensors and presents the operator with a visual indication of the leak location and magnitude. Although the leak monitoring system was designed for hydrogen propulsion systems, the possible applications of this monitoring system are wide ranged. This system is in operation in an automotive application which requires high sensitivity to hydrogen.

Hunter, Gary W.↗

Automated Hydrogen Gas Leak Detection System

The Gencorp Aerojet Automated Hydrogen Gas Leak Detection System was developed through the cooperation of industry, academia, and the Government. Although the original purpose of the system was to detect leaks in the main engine of the space shuttle while on the launch pad, it also has significant commercial potential in applications for which there are no existing commercial systems. With high sensitivity, the system can detect hydrogen leaks at low concentrations in inert environments. The sensors are integrated with hardware and software to form a complete system. Several of these systems have already been purchased for use on the Ford Motor Company assembly line for natural gas vehicles. This system to detect trace hydrogen gas leaks from pressurized systems consists of a microprocessor-based control unit that operates a network of sensors. The sensors can be deployed around pipes, connectors, flanges, and tanks of pressurized systems where leaks may occur. The control unit monitors the sensors and provides the operator with a visual representation of the magnitude and locations of the leak as a function of time. The system can be customized to fit the user's needs; for example, it can monitor and display the condition of the flanges and fittings associated with the tank of a natural gas vehicle.

Source record↗

An Experimental Investigation of Leak Rate Performance of a Subscale Candidate Elastomer Docking Space Seal

A novel docking seal was developed for the main interface seal of NASA s Low Impact Docking System (LIDS). This interface seal was designed to maintain acceptable leak rates while being exposed to the harsh environmental conditions of outer space. In this experimental evaluation, a candidate docking seal assembly called Engineering Development Unit (EDU58) was characterized and evaluated against the Constellation Project leak rate requirement. The EDU58 candidate seal assembly was manufactured from silicone elastomer S0383-70 vacuum molded in a metal retainer ring. Four seal designs were considered with unique characteristic heights. The leak rate performance was characterized through a mass point leak rate method by monitoring gas properties within an internal control volume. The leakage performance of the seals were described herein at representative docking temperatures of -50, +23, and +50 C for all four seal designs. Leak performance was also characterized at 100, 74, and 48 percent of full closure. For all conditions considered, the candidate seal assemblies met the Constellation Project leak rate requirement.

Garafolo, Nicholas G.↗

Local Leak Detection and Health Monitoring of Pressurized Tanks

An optical gas-detection sensor safely monitors pressurized systems (such as cryogenic tanks) and distribution systems for leaks. This sensor system is a fiber-coupled, solid optical body interferometer that allows for the miniaturized sensing element of the device to be placed in the smallest of recesses, and measures a wide range of gas species and densities (leaks). The deflection of the fringe pattern is detected and recorded to yield the time-varying gas density in the gap. This technology can be used by manufacturers or storage facilities with toxic, hazardous, or explosive gases. The approach is to monitor the change in the index of refraction associated with low-level gas leaks into a vacuum environment. The completion of this work will provide NASA with an enabling capability to detect gas system leaks in space, and to verify that pressurized systems are in a safe (i.e. non-leaking) condition during manned docking and transit operations. By recording the output of the sensor, a time-history of the leak can be constructed to indicate its severity. Project risk is mitigated by having several interferometric geometries and detection techniques available, each potentially leveraging hardware and lessons learned to enhance detectability.

Polzin, Kurt↗

Distributed wireless sensing for methane leak detection technology

Large scale environmental monitoring requires dynamic optimization of data transmission, power management, and distribution of the computational load. In this work, we demonstrate the use of a wireless sensor network for detection of chemical leaks on gas oil well pads. The sensor network consist of chemi-resistive and wind sensors and aggregates all the data and transmits it to the cloud for further analytics processing. The sensor network data is integrated with an inversion model to identify leak location and quantify leak rates. We characterize the sensitivity and accuracy of such system under multiple well controlled methane release experiments. It is demonstrated that even 1 hour measurement with 10 sensors localizes leaks within 1 m and determines leak rate with an accuracy of 40%. This integrated sensing and analytics solution is currently refined to be a robust system for long term remote monitoring of methane leaks, generation of alarms, and tracking regulatory compliance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gaining Real-Time Water Leak Detection

Devens Reserve Forces Training Area is a United States Army Reserve (USAR) Installation that struggles with severe water leaks, often causing significant damage to the facility and requiring major renovation. Traditional water use is highly dependent on occupancy, so it can be difficult to benchmark a facility’s water use. It can be exceptionally difficult when occupancy is transient and/or varies. Pacific Northwest National Laboratory (PNNL) collaborated with Devens to implement real-time monitoring of their water consumption by utilizing the smart meter data from their existing 23 water meters. PNNL created a simple algorithm to calculate hourly water consumption and trigger an alert to be instantly emailed to Devens’ personnel when there appears to be a water leak in any building with a smart water meter. Here, this approach is expected to save hundreds of thousands of dollars in unnecessary water consumption costs and damages from leaks and was implemented with little-to-no costs or service disruptions. Next steps for this project include slow leak detection through nighttime monitoring and to extrapolate this water leak approach to the remainder 360 water meters on USAR’s Enterprise Building Control System so USAR sites across the country can be instantly notified of potential water leaks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗