Qualification and reliability testing of a microchip laser system for space applications
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The Geoscience Laser Altimeter System (GLAS), launched in January 2003, is a laser altimeter and lidar for the Earth Observing System's (EOS) ICESat mission. GLAS accommodates three, sequentially operated, diode-pumped, solid-state, Nd:YAG laser transmitters. The laser transmitter requirements, design and qualification test results for this space-based remote sensing instrument is summarized and presented
A holographic grating at grazing angle of incidence was used to achieve tunable, narrow bandwidth (0.005 nm) operation of a XeCl oscillator for injection locking of a ring amplifier. The amplifier's narrow bandwidth output energy was constant and equal to the untuned, broadband output (approximately 15 mJ) in regions where injection locking was achieved. Scanning was provided by use of a stepping motor-driven differential micrometer on the tuning mirror. This system was used to produce a laser excitation spectrum of hydroxyl radicals (OH) in a flame.
A program is under way to develop a YAG laser based materials processing workstation to fly in the cargo bay of the Space Shuttle. The system will be capable of cutting and welding steel, aluminum, and Inconel alloys of the type planned for use on Space Station Freedom. As well as demonstrating the ability of a YAG laser to perform remote (fiber-optic delivered) repair and fabrication operations in space, fundamental data will be collected on these interactions for comparison with terrestrial data and models. The flight system, scheduled to fly in 1995, will be constructed as two modules to fit into the standard Get Away Special (GAS) canisters. The first can holds the laser and its power supply, to be constructed by our industrial partner, Lumonics Industrial Processing Division. The second canister has the materials processing workstation and the command and data acquisition subsystems. These components will be provided by groups at the University of Tennessee Space Institute (UTSI) and the University of Waterloo. The cans are linked by a fiber-optic cable which transmits the beam from the laser head to the workstation.
Optical rendezvous guidance system and ground based optical tracking system development
A dual-beam, injection-seeded, Nd:YAG laser has been demonstrated for detecting structural defects. This demonstration was part of an on-going project to use dual-reference-beam holographic interferometry to inspect space propulsion components for cracks, structural failures, structural changes, and gas leaks. Potential subjects for inspection include welds, duct work, casings, turbopumps, blades, composites, and ceramics. The maximum dimension of an inspected area ranges from a few centimeters to a meter. The entire optical inspection system is now ready for a demonstration application.
The Langley Research Center redesigned the cooler test bed hardware for the refrigerator for the purpose of isolating the tunable diode laser (TDL) from the cold tip in a laser heterodyne spectrometer system. Deflection in the lateral and vertical directions were managed on the cold tip and on the TDL. Measurements were analyzed over the frequency range of 0.100 Hz. The results show that the TDL responds approximately one order of magnitude less than that of the cold tip. The redesign of the system provided for adequately isolating the TDL for future operation.
The design features and performance characteristics of a sensitized holmium laser applicable to differential lidar and Doppler windshear measurements are presented, giving attention to the optimal choice of sensitizing/activating dopant ions. This development of a 2-micron region eye-safe laser, where holmium is sensitized by either hulium or erbium, has called for interionic energy transfer processes whose rate will not result in gain-switched pulses that are excessively long for atmospheric lidar and Doppler windshear detection. The application of diamond films for optical component hardening is noted.
For the first time, beam quality improvement of 2 micron laser using a fiber based phase conjugation mirror has been demonstrated. Single frequency operation is necessary to lower threshold. The reflectivity of PCM is approx. 50%.
The advantages of tunable-diode-laser absorption spectrometry (TDLAS) for measuring trace atmospheric gases are universality, positive identification, good sensitivity, and rapid response time. A TDLAS system is described which is capable of making measurements aboard an aircraft. The instrument was employed during the Chemical Instrumentation Test and Evaluation (CITE) 2 program to measure NO2 on 11 flights and HNO3 on five flights. Detection limits were determined to be 25 parts per trillion by volume (pptv) for NO2 and 75 pptv for HNO3 with response times of 3 min. This was sufficient to permit measurements of NO2 in the free troposphere and HNO3 in the continental boundary layer a significant fraction of the time.
This project demonstrated the feasibility of using laser remote sensing technology as a tool for leak survey work in natural gas distribution systems. A laboratory device was assembled using a pair of helium neon (HeNe) lasers to measure methane. One HeNe laser emits radiation at a wavelength of 3.3922 micrometers, which corresponds to a strong absorption feature of methane, while the other emits radiation at a wavelength of 3.3911 micrometers, which corresponds to a weak absorption by methane. As a particular area is scanned for leaks, the laser is pointed at convenient topographic targets within its operating range, about 25 m. A portion of the backscattered radiation is collected by a receiver and focused onto an indium antimonide (InSb) photodetector, cooled to 77K. Methane concentrations were determined from the differential absorption at the two wavelengths for the backscattered radiation.
A solid-state apparatus for tracking the wavelength of a laser emission has a power splitter that divides the laser emission into at least three equal components. Differing phase shifts are detected and processed to track variations of the laser emission.
Temperature dependent extracavity and intracavity etalon effects in optical materials for carbon dioxide lasers
Broadly tunable and high-power operation of a Ti-doped sapphire laser is obtained with a diode-laser-pumped frequency-doubled Nd:YAG laser as the pump source. A maximum broadband (FWHM = 25 nm) output pulse energy of 720 microJ at 795 nm in a TEM00 mode is obtained for 1850 microJ of energy of 532-nm pump light. A minimum pulse duration of 7 nsec is obtained from a 40-mm-long cavity. With the use of an intracavity prism, the Ti:sapphire laser is tunable continuously over the 696-1000-nm spectral range (with three different mirror sets).
Contractor shall perform a complete analysis of the potential of the solid state laser in the very long pulse mode (100 ns pulse width, 10-30 hz rep-rate) and in the very short pulse mode (100 ps pulse width 10-30 hz rep rate) concentrating on the operation of the device in the 'hot-rod' mode, where no active cooling the laser operation is attempted. Contractor's calculations shall be made of the phase aberrations which develop during the repped-pulse train, and the results shall feed into the adaptive optics analyses. The contractor shall devise solutions to work around ORION track issues. A final report shall be furnished to the MSFC COTR including all calculations and analysis of estimates of bulk phase and intensity aberration distribution in the laser output beam as a function of time during the repped-pulse train for both wave forms (high-energy/long-pulse, as well as low-energy/short-pulse). Recommendations shall be made for mitigating the aberrations by laser re-design and/or changes in operating parameters of optical pump sources and/or designs.
Since the last report several things have happened to effect the research effort. In laser metrology, measurements using Michelson type interferometers with an FM modulated diode laser source have been performed. The discrete Fourier transform technique has been implemented. Problems associated with this technique as well as the overall FM scheme were identified. The accuracy of the technique is not at the level we would expect at this point. We are now investigating the effect of various types of noise on the accuracy as well as making changes to the system. One problem can be addressed by modifying the original optical layout. Our research effort was also expanded to include the assembly and testing of a diode pumped\Nd:YAG laser pumped\Ti sapphire laser for possible use in sounding rocket applications. At this stage, the diode pumped Nd:YAG laser has been assembled and made operational.
Crystallization calculations were performed in order to determine the possibility of forming a particular type of laser glass with the avoidance of devitrification in an outer space laboratory. It was demonstrated that under the homogenuous nucleating conditions obtainable in a zero gravity laboratory this laser glass may be easily quenched to a virtually crystal-free product. Experimental evidence is provided that use of this material as a host in a neodymium glass laser would result in more than a 10 percent increase in efficiency when compared to laser glass rods of a similar composition currently commercially available. Differential thermal analysis, thermal gradient oven, X-ray diffraction, and liquidus determination experiments were carried out to determine the basics of the crystallization behavior of the glass, and small-angle X-ray scattering and splat-cooling experiments were performed in order to provide additional evidence for the feasibility of producing this laser glass material, crystal free, in an outer space environment.
Nitric oxide, ozone, and ethylene were monitored over roads during periods of heavy traffic by transmitting several known laser wavelengths over an atmospheric path and measuring the differential absorption of the wavelengths. Heavy afternoon traffic between four and five o'clock over a 3.75 km path produced a noticeable increase in ethylene and a decrease in ozone. The changes occurred on a short time scale and correlated with the sudden traffic density increase. The ozone decrease occurs because of the sudden presence of large quantities of nitric oxide. Although the laboratory laser equipment used is rather cumbersome, the measurements did point out the potential of the laser absorption technique for monitoring large areas from one location.-