Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Upgrading and performance of the SAO laser ranging system in Matera

The performance of the SAO lasers was improved considerably in terms of accuracy, range noise, data yield, and reliability. With the narrower laser pulse (2.5-3.0 nsec) and a new analog pulse processing system, the systematic range errors were reduced to 3-5 cm and range noise has been reduced to 5-15 cm on low satellites and 10-18 cm on Lageos. Pulse repetition rate was increased to 30 ppm and considerable improvement has been made in signal-to-noise ratio by using a 3 Angstrom interference filter and by reducing the range gate window down to 200-400 nsec. The first upgraded system was installed in Arequipa, Peru in the spring of 1982. The second upgraded system is now in operation in Matera, Italy. The third system is expected to be installed in Israel during 1984.

Maddox, J.↗

Project Longshot: A mission to Alpha Centauri

Project Longshot, an exercise in the Advanced Design Program for Space, had as its destination Alpha Centauri, the closest star system to our own solar system. Alpha Centauri, a trinary star system, is 4.34 light years from earth. Although Project Longshot is impossible based on existing technologies, areas that require further investigation in order to make this feat possible are identified. Three areas where advances in technology are needed are propulsion, data processing for autonomous command and control functions, and reliability. Propulsion, possibly by antimatter annihilation; navigation and navigation aids; reliable hardware and instruments; artificial intelligence to eliminate the need for command telemetry; laser communication; and a reliable, compact, and lightweight power system that converts energy efficiently and reliably present major challenges. Project Longshot promises exciting advances in science and technology and new information concerning the universe.

West, Curtis↗

Quasi-CW Laser Diode Bar Life Tests

NASA's Goddard Space Flight Center is developing technology for satellite-based, high peak power, LIDAR transmitters requiring 3-5 years of reliable operation. Semi-conductor laser diodes provide high efficiency pumping of solid state lasers with the promise of long-lived, reliable operation. 100-watt quasi- CW laser diode bars have been baselined for the next generation laser altimeters. Multi-billion shot lifetimes are required. The authors have monitored the performance of several diodes for billions of shots and investigated operational modes for improving diode lifetime.

Stephen, Mark A.↗

Satellite tracking and Earth dynamics research programs

Following an upgrading program, ranging performance capabilities of a satellite-tracking pulsed laser system were assessed in terms of range accuracy, range noise, data yield, and reliability. With a shorter laser pulse duration (2.5 to 3.0 NSEC) and a new analog pulse processing system, the systematic range errors were reduced to 3 to 5 cm and range noise was reduced to 5 to 16 cm and range noise was reduced to 5 to 15 cm on Starlette and BE-C, and 10 to 18 cm on LAGEOS. Maximum pulse repetition rate was increased to 30 pulses per minute and significant improvement was made in signal to noise ratio by installing a 3 A interference filter and by reducing the range gate window to 200 to 400 nsec. The solution to a problem involving leakage of a fraction of the laser oscillator pulse through the pulse chopper was outlined.

Pearlman, M. R.↗

Independent Reliability Assessment and Progress Review of the NASA GSFC Laser Transmitter for the LISA Program

NASA Goddard Space Flight Center (GSFC) has been actively developing the laser transmitter for the Laser Interferometer Space Antenna (LISA) program since the late 2017. In 2021 we delivered a prototype laser transmitter to the LISA program for performance evaluation as well as performed an independent technology assessment on the laser design supported by the NASA Engineering and Safety Center (NESC). We continued to further develop the LISA laser with a goal of advancing the technology readiness level (TRL) of the laser to 6 by the end of 2023. In this paper, we report on the progress we made on the laser development for the LISA program as well as the technology assessment findings by the NESC.

Independent Reliability Assessment↗

Long-duration Operation of 2-micron Coherent Doppler Lidar in Space

The reliability and lifetime of laser remote sensing systems that can operate autonomously over a sufficiently long period are mainly constrained by the laser diode arrays (LDAs) used for pumping their laser transmitters. The lifetime of a 2-micron coherent lidar operating in space is particularly of concern in lieu of required pump pulse duration of Thulium and Holmium solid state lasers (approx. 1msec) that are considerably longer than those of more widely used 1-micron lasers (< 0.2 msec). A factor of 5 to 10 times longer pulse duration can easily translate to over an order of magnitude shorter lifetime for a typical commercially available high-power 2-D array. Therefore, it is imperative to address the lifetime and reliability of LDAs for pumping 2-micron lasers by exploring all the potential options that significantly prolong their life meeting the required operational lifetime of space-based coherent Doppler lidars. The leading causes of sudden failure and premature degradation of LDAs are intrinsic semiconductor defects, optical facet breakdown resulting from excessive localized heating, and thermo-mechanical stresses due to the extreme thermal cycling of the laser active regions1-2. Long pulse operation grossly amplifies the impact of these failure/degradation causes, particularly the thermo-mechanical stresses due to pulse-to-pulse thermal cycling. Therefore, several experimental setups have been developed to investigate each of the failure mechanisms and causes of premature degradation in order to evaluate various package designs, define the best operating parameters, and to guide the technology advancement, leading to highly reliable and very long lifetime LDAs5. Several areas of improvement in the packaging and fabrication process of laser diodes have already been identified and efforts towards implementing these improvements are well underway. These efforts include the use of advanced high thermal conductivity materials for packaging of laser diode arrays and new fabrication techniques for mechanically attaching laser diode bars and submounts. But even using the existing LDAs, it may be possible to increase the lifetime by careful selection of the package type, number of bars per package and their pitch, operational temperature, and operating parameters such repetition rate, pulsewidth, and applied current. Obviously, the LDA specification and operational parameters will involve a system level trade analysis to ensure that the lidar instrument meets its performance objectives. One goal of this work is to enable such trade analysis by evaluating LDAs from different suppliers in different package types and quantifying their performance as a function of their operational parameters.

Amzajerdian, Farzin↗

Reliability of constricted double-heterojunction AlGaAs diode lasers

Constricted double-heterojunction diode lasers have been life tested at 70 C heatsink temperature and 3-4 mW/facet in CW operation. A median life of 7800 h is obtained at 70 C, which extrapolates to 400,000 h median life at room temperature. The extrapolated mean time to failure at room temperature is in excess of 1,000,000 h. Single-longitudinal-mode CW operation is maintained after 10,000 h of accelerated aging at 70 C.

Botez, D.↗

Evaluation of a satellite laser ranging technique using pseudonoise code modulated laser diodes

Several types of Satellite Laser Ranging systems exist, operating with pulsed, high-energy lasers. The distance between a ground point and an orbiting satellite can be determined to within a few centimeters. A new technique substitutes pseudonoise code modulated laser diodes, which are much more compact, reliable and less costly, for the lasers now used. Since laser diode technology is only now achieving sufficiently powerful lasers, the capabilities of the new technique are investigated. Also examined are the effects of using an avalanche photodiode detector instead of a photomultiplier tube. The influence of noise terms (including background radiation, detector dark and thermal noise and speckle) that limit the system range and performance is evaluated.

Ball, Carolyn Kay↗

Plasma decay of nanosecond pulsed laser-produced Ar and Ar–H 2 O sparks at atmospheric pressure

Time-resolved diagnostics were applied to investigate free-electron properties in nanosecond laser-produced discharges generated in atmospheric pressure Ar and in Ar–3%H 2 O. The discharges were generated using 23 ns, 1064 nm laser pulses. Broadband plasma imaging and laser Thomson scattering were combined with optical emission spectroscopy, with particular emphasis on the Stark broadening of the H α and H β lines. The plasma exhibited a bright emission that persists for up to 30–40 µs after breakdown. Plasma emission was then followed by a very weak glow emission that persisted for up to 19 ms after breakdown. Peak electron number density of ∼2 × 10 17 cm −3 and electron temperature of ∼7 eV were measured. An excellent agreement between both techniques was obtained regarding absolute electron number densities. The inferred free-electron temporal decay dynamics are consistent with processes dominated by hydrodynamic expansion and two- and three-body electron–ion recombination. These results provide benchmark data for modeling nanosecond laser discharges and demonstrate the reliability of combining Thomson scattering with Stark broadening in atmospheric laser sparks.

Thomson scattering↗

2.0 um Wavelength Injection Seed Semiconductor Laser for Lidar Transmitter for Global-Scale Measurements of CO2

Many of the high accuracy Earth science survey missions are planned to use laser-based remote sensing instruments. The 2-μm laser wavelength is of particular interest due to the presence of many CO2 and H20 absorption lines in its vicinity1. Transmitter architectures are typically composed of an optically pumped, frequency-stable, solid-state seed laser and a high-power optical amplifier.2, 3 Taking advantage of the reliability and relative simplicity of semiconductor lasers, this architecture can substantially improve by replacing the solid-state light source with semiconductor lasers of comparable performance. This approach will greatly improve the system reliability, and will simplify instrument integration and space qualification. There are currently very limited semiconductor lasers operating in the 2-m range with performance satisfactory enough for use as an injection seed in a laser absorption spectrometer. Optimally, seed lasers producing greater than 50 mW of continuous-wave (CW), with frequency jitter of less than 1 MHz are desired to reliably resolve the CO2 absorption lines near 2-µm. In this paper, we report the demonstration of high-power, single-longitudinal-mode laterally coupled distributed feedback (LC-DFB) lasers at 2.05 µm wavelength. We measured more than 80 mW of CW power at -10 ºC for devices with a 4-µm-wide ridge and 2-mm-long cavity.

Fradet, Mathieu↗

Environmental testing of a diode-laser-pumped Nd:YAG laser and a set of diode-laser-arrays

Results of the environmental test of a compact, rigid and lightweight diode-laser-pumped Nd:YAG laser module are discussed. All optical elements are bonded onto the module using space applicable epoxy, and two 200 mW diode laser arrays for pump sources are used to achieve 126 mW of CW output with about 7 percent electrical-to-optical conversion efficiency. This laser assembly and a set of 20 semiconductor diode laser arrays were environmentally tested by being subjected to vibrational and thermal conditions similar to those experienced during launch of the Space Shuttle, and both performed well. Nevertheless, some damage to the laser front facet in diode lasers was observed. Significant degradation was observed only on lasers which performed poorly in the life test. Improvements in the reliability of the Nd:YAG laser are suggested.

Hemmati, H.↗

CO2 laser cold cathode study

The procedure for evaluating reliable sputter-free cold cathodes for carbon dioxide lasers is discussed. The purpose of the development is to obtain cold cathodes with service life in excess of 10,000 hours. Discharge tubes are used to eliminate the materials which would be unsatisfactory for use as a cold cathode. A description of the facility for producing the discharge tubes is described. The gas monitoring technique for determining discharge tube performance is examined. Discharge characteristics of tubes with various metals for cathode material are presented in chart form.

Hochuli, U.↗

Reliable Determination of Pulses and Pulse-Shape Instability in Ultrashort Laser Pulse Trains Using Polarization-Gating and Transient-Grating Frequency-Resolved Optical Gating Using the RANA Approach

Devices that measure the presence of instability in the pulse shapes in trains of ultrashort laser pulses do not exist, so this task necessarily falls to pulse-measurement devices, like Frequency-Resolved Optical Gating (FROG) and its variations, which have proven to be a highly reliable class of techniques for measuring stable trains of ultrashort laser pulses. Fortunately, multi-shot versions of FROG have also been shown to sensitively distinguish trains of stable from those of unstable pulse shapes by displaying readily visible systematic discrepancies between the measured and retrieved traces in the presence of unstable pulse trains. However, the effects of pulse-shape instability and algorithm stagnation can be indistinguishable, so a never-stagnating algorithm—even when instability is present—is required and is generally important. In previous work, we demonstrated that our recently introduced Retrieved-Amplitude N-grid Algorithmic (RANA) approach produces highly reliable (100%) pulse-retrieval in the second-harmonic-generation (SHG) version of FROG for thousands of sample trains of pulses with stable pulse shapes. Further, it does so even for trains of unstable pulse shapes and thus both reliably distinguishes between the two cases and provides a rough measure of the degree of instability as well as a reasonable estimate of most typical pulse parameters. Here, we perform the analogous study for the polarization-gating (PG) and transient-grating (TG) versions of FROG, which are often used for higher-energy pulse trains. We conclude that PG and TG FROG, coupled with the RANA approach, also provide reliable indicators of pulse-shape instability. In addition, for PG and TG FROG, the RANA approach provides an even better estimate of a typical pulse in an unstable pulse train than SHG FROG does, even in cases of significant pulse-shape instability.

47 OTHER INSTRUMENTATION↗

Stable isotope laser spectroscopy

Recent advances in semiconductor laser technology have produced a reliable lightweight device ideally suited for a spacecraft high resolution molecular spectrometer. Lead-salt tunable diode lasers (TDL) emit in several spectral modes, each with a very narrow linewidth of -0.0003/cm. This spectral resolution is much narrower than typical Doppler broadened molecular linewidths in the mid-IR range. Thus it is possible to detect individual rotational lines within the vibrational band and measure their intensity, which can be used to determine gas concentration. The narrow spectral lines of any impurity gas tend to lie between the narrow lines of the gas of interest. This represents a major advantage over the accepted gas chromatograph mass spectrometer (GCMS) technique for measuring gas concentrations and isotope ratios. The careful and extensive gas purification procedures required to remove impurities for reliable GCMS measurements will not be required for an IR laser gas analysis. The infrared laser gas analysis technique is being developed to measure stable isotopic ratios of gases such as CO2, CH4, N2O, and NH3. This will eventually lead to development of instruments capable of in situ istopic measurements on planets such as Mars. The carbon (C-12, C-13) isotope ratio is indicative of the type of carbon fixation mechanisms (e.g., photosynthesis, respiration) in operation on a planet, while the nitrogen (N-14, N-15) isotope ratio can probably be used to date nitrogen-bearing Martian samples. The absorbance ratio of two adjacent lines of CO2 in the 2300/cm (4.3 micron) region of the spectrum was measured. The precision of the measurement is presently better than 1 percent and significant improvement is anticipated as rapid sweep-integration techniques and computer controlled data acquistion capabilities are incorporated.

Becker, J. F.↗

Measuring Atmospheric Turbulence With Lidar

Laser Doppler measurements promise reliably accurate indications of wind speed and turbulence. Report compares two kinds of measurements of wind and turbulence: from instruments aboard aircraft and from ground-based Doppler measurements by laser ranging equipment (lidar).

Frost, W.↗

Measurement in multiphase reacting flows

A survey is presented of diagnostic techniques and measurements made in multiphase reacting flows. The special problems encountered by the presence of liquid droplets, soot and solid particles in high temperature chemically reacting turbulent environments are outlined. The principal measurement techniques that have been tested in spray flames are spark photography, laser anemometry, thermocouples and suction probes. Spark photography provides measurement of drop size, drop size distribution, drop velocity, and angle of flight. Photographs are analysed automatically by image analysers. Photographic techniques are reliable, inexpensive and proved. Laser anemometers have been developed for simultaneous measurement of velocity and size of individual particles in sprays under conditions of vaporization and combustion. Particle/gas velocity differentials, particle Reynolds numbers, local drag coefficients and direct measurement of vaporization rates can be made by laser anemometry. Gas temperature in sprays is determined by direct in situ measurement of time constants immediately prior to measurement with compensation and signal analysis by micro-processors. Gas concentration is measured by suction probes and gas phase chromatography. Measurements of particle size, particle velocity, gas temperature, and gas concentration made in airblast and pressure atomised liquid spray flames are presented.

Chigier, N. A.↗

Design and Applications of Tethered Spacecraft Simulators

Small, tethered spacecraft, or space tugs, are a promising space capability. They can be deployed on tethers and used for a wide variety of in-space activities; a large portion of which fall under in-space servicing, assembly, manufacturing (ISAM) functions. This includes functions such as structural mating and assembly, servicing, proximity operations, capture, docking, mating, and relocation. However, there is a great deal of work to be done to raise the Technology Readiness Level (TRL) of the capabilities needed to fully realize these capabilities. The Flat Floor Robotics Lab (FFRL) at NASA’s Marshall Spaceflight Center (MSFC) has been working on space tug development for several years. The eponymous floor is 44 by 86 feet, made from a self-leveling epoxy. This creates an extremely smooth surface that air bearings can float on with very little friction, creating a simulation of zero gravity in a two-dimensional plane. The lab has several platforms of various sizes that act as vehicle simulators for testing sensors, control algorithms, mechanisms, etc. One of these platforms is a small spacecraft simulator, which can be tethered to simulate a space tug. In the last several months, the FFRL team has been working with MSFC’s welding group to conduct a laser beam welding demonstration on air bearing platforms. This demo is utilizing a space tug simulator to fly up to a floating weld platform, where two parts are clamped together and laser welded. The space tug simulator has an air bearing to provide float, as well as several actuated air thrusters to provide propulsion and make the simulator maneuverable. Currently, flights of this simulator are completed by a human operator. An RF hand controller sends signals to both actuate and fire three sets of thrusters on the simulator. This makes any maneuvers of the space tug highly subject to human error, and operators must have dedicated practice time before being able to perform maneuvers with any sufficient reliability. For the current laser welding demonstration, human operated performance is sufficient, but future implementations of in-space welding and other ISAM efforts will require higher precision, reliability, and autonomy. MSFC has funded a project that will allow a small team in the FFRL to develop the next generation of space tug simulator, which will be automated. Closed loop control will allow a user to command a position, or set of positions, that the simulator will be able to “fly” to on its own. This Maneuverable Automated Tethered Spacecraft (MATS) simulator will have configurable design, to allow a variety of payloads and mission configurations to be demonstrated on the air bearing floor. This will be an invaluable test bed for low and mid TRL advancement for space tether mission subsystems, such as more advanced demonstrations of in-space welding. Once one MATSS is constructed and demonstrated effectively, several more can be built, enabling more advanced tether missions; Electric Sail test beds, sensor arrays, and other science-enabling missions. This paper will detail the design and test of the FFRL’s MATS simulator, including efforts to establish closed loop control and autonomous capabilities. It will also detail use cases for this technology, and how it will further develop both develop science and exploration missions.

Space Tethers↗

The Global Ecosystem Dynamics Investigation (GEDI) Lidar Laser Transmitter

The Global Ecosystems Dynamics Investigation (GEDI) Lidar, is an Earth Science remote sensing instrument aboard the International Space Station (ISS) and the Japanese Experiment Module (JEM). Its core mission is to measure the global carbon balance of Earth's forests by using a set of three solid state laser transmitters in a multibeam waveform capture lidar technique. GEDI's laser transmitters and precision optical system transmits over 3.4 million laser pulses to the Earth every hour, each pulse producing an individual 3-D biomass column measurement. To enable a successful two-year mission, the lasers had to be reliable, highly repeatable in performance with each measurement power cycle, and designed with minimal part count for reduced manufacture complexity and cost. These transmitters are in-house products; developed, constructed, qualified, and fully integrated into the GEDI instrument at NASA's Goddard Space Flight Center. We will present the lasers' path from initial design to flight operation, with emphasis on the major milestones, critical issues, and lessons learned. Full credit goes to the excellent team effort that led to the successful commissioning and initiation of full-time science operations in March 2019.

Coyle, D. Barry↗