Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Noise equivalent circuit of a semiconductor laser diode

A small-signal model of a semiconductor laser is extended to include the effects of intrinsic noise by adding current and voltage noise sources. The current noise source represents the shot noise of carrier recombination, while the voltage noise source represents the random process of simulated emission. The usefulness of the noise equivalent circuit is demonstrated by calculating the modulation and noise characteristics of a current-driven diode as a function of bias current and frequency.

Harder, C.↗

Obstacle detection for the Mars Rover by a two dimensional rapid estimation scheme

This paper discusses an obstacle detection system applicable to a Mars Rover mission forseen possible in the early 1980's. The sensing device on the rover will be a laser rangefinder which scans the surface ahead of the vehicle. Terrain range data information is stored in matrix form. The range varies from point to point along the surface with sharp changes due to the presence of obstacles. The noise contaminated laser rangefinder readings are processed by an algorithm involving a modified version of the Kalman Filter, along with a decision scheme, to obtain complete outlines of discrete obstacles.

Alland, S.↗

Design of a fiber-optic transmitter for microwave analog transmission with high phase stability

The principal considerations in the design of fiber-optic transmitters for highly phase-stable radio frequency and microwave analog transmission are discussed. Criteria for a fiber-optic transmitter design with improved amplitude and phase-noise performance are developed through consideration of factors affecting the phase noise, including low-frequency laser-bias supply noise, the magnitude and proximity of external reflections into the laser, and temperature excursions of the laser-transmitter package.

Logan, R. T., Jr.↗

Frequency References for Gravitational Wave Missions

The mitigation of laser frequency noise is an important aspect of interferometry for LISA-like missions. One portion of the baseline mitigation strategy in LISA is active stabilization utilizing opto-mechanical frequency references. The LISA optical bench is an attractive place to implement such frequency references due to its environmental stability and its access to primary and redundant laser systems. We have made an initial investigation of frequency references constructed using the techniques developed for the LISA and LISA Pathfinder optical benches. Both a Mach-Zehnder interferometer and triangular Fabry-Perot cavity have been successfully bonded to a Zerodur baseplate using the hydroxide bonding method. We will describe the construction of the bench along with preliminary stability results.

Preston, Alix↗

Shot noise limited detection of OH using the technique of laser-induced fluorescence

Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluoresence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the short-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.

Bakalyar, D. M.↗

Airborne tunable diode laser system for trace gas measurements

Sachse et al. (1976) have reported the development of an airborne tunable diode laser (TDL) system, named the Differential Absorption CO Monitor (DACOM). The absorption path was 10 m long and located in the free airstream along the fuselage of a C-54 aircraft. The present investigation is concerned with a modification of the DACOM instrument. Differences between the new instrument and the original one are related to a replacement of the external absorption path with a White cell. The instrument has the capability to suppress TDL excess noise. The laser refrigerator has been redesigned to permit an alternative method of cooling the TDL when electric power is not available.

Sachse, G. W.↗

Laser amplification of incoherent radiation

The amplification of noise in a laser amplifier is treated theoretically. The model for the active medium and its description using density-matrix techniques, are taken from the theory of laser operation. The spectral behavior of the radiation in the nonlinear regime is studied and the formalism is written from the onset in the frequency domain. The statistics of the light are gradually modified by the nonlinear amplification process, and expressions are derived for the rate of change of fluctuations in intensity as a measure of statistical changes. In addition, the range of validity of Litvak's Gaussian-statistics approximation is discussed. In the homogeneous-broadening case, the evolution of initially broadband Gaussian radiation toward quasimonochromatic oscillations with laserlike statistics is explored in several numerical examples. The connections of this study with the time-domain work on self-pulsing in a ring-laser configuration, are established. Finally, spectral-narrowing and -rebroadening effects in Doppler-broadened media are discussed both analytically and with numerical examples. These examples show the distinct contribution of pulsations in the population ('Raman-type terms'), and saturation phenomena.

Menegozzi, L. N.↗

Time Domain Simulations of Arm Locking in LISA

Arm locking is a technique that has been proposed for reducing laser frequency fluctuations in the Laser Interferometer Space Antenna (LISA). a gravitational-wave observatory sensitive' in the milliHertz frequency band. Arm locking takes advantage of the geometric stability of the triangular constellation of three spacecraft that comprise LISA to provide a frequency reference with a stability in the LISA measurement band that exceeds that available from a standard reference such as an optical cavity or molecular absorption line. We have implemented a time-domain simulation of arm locking including the expected limiting noise sources (shot noise, clock noise. spacecraft jitter noise. and residual laser frequency noise). The effect of imperfect a priori knowledge of the LISA heterodyne frequencies and associated "pulling" of an arm locked laser is included. We find that our implementation meets requirements both on the noise and dynamic range of the laser frequency.

Thorpe, J. I.↗

Frequency-tunable Pre-stabilized Lasers for LISA via Sideband-locking

Laser frequency noise mitigation is one of the most challenging aspects of the LISA interferometric measurement system. The unstabilized frequency fluctuations must be suppressed by roughly twelve orders of magnitude in order to achieve stability sufficient for gravitational wave detection. This enormous suppression will be achieved through a combination of stabilization and common-mode rejection. The stabilization component will itself be achieved in two stages: pre-stabilization to a local optical cavity followed by arm-locking to some combination of the inter-spacecraft distances. In order for these two stabilization stages to work simultaneously, the lock-point of the pre-stabilization loop must be frequency tunable. The current baseline stabilization technique, locking to an optical cavity, does not provide tunability between cavity resonances, which are typically spaced by 100s of MHz. Here we present a modification to the traditional Pound-Drever-Hall cavity locking technique that allows the laser to be locked to a cavity resonance with an adjustable frequency offset. This technique requires no modifications to the optical cavity itself, thus preserving the stability of the frequency reference. We present measurements of the system performance and demonstrate that we can meet implement the first two stages of stabilization.

Livas, Jeffrey C.↗

Frequency-Tuneable Pre-Stabilized Lasers for LISA via Sideband Locking

Laser frequency noise mitigation is one of the most challenging aspects of the LISA interferometric measurement system. The unstabilized frequency fluctuations must be suppressed by roughly twelve orders of magnitude in order to achieve a stability sufficient for gravitational wave detection. This enormous suppression will be achieved through a combination of stabilization and common-mode rejection. The stabilization component will itself be achieved in two stages: pre-stabilization to a local optical cavity followed by arm-locking to some combination of the inter-spacecraft distances. In order for these two stabilization stages to work simultaneously, the lock-point of the pre-stabilization loop must be frequency tunable. The current baseline stabilization technique, locking to an optical cavity, does not provide tunability between cavity resonance, which are typically spaced by 100s of MHz. Here we present a modification to the traditional Pound-Drever-Hall cavity locking technique that allows the laser to be locked to a cavity resonance with an adjustable frequency offset. This technique requires no modifications to the optical cavity itself, thus preserving the stability of the frequency reference. We present measurements of the system stability, demonstrating that the pre-stabilization level satisfies LISA requirements. We also present a demonstration of a phase-lock loop which utilizes the tunable sideband locking technique as a pre-stabilizations tage. The performance of the pre-stabilized phase-lock-loop indicates that the tunable sideband technique will meet the requirements as an actuator for arm-locking in LISA.

Thorpe, James Ira↗

On-target uniformity of the OMEGA 60-beam inertial confinement fusion laser

Successful direct-drive inertial confinement fusion (ICF) experiments require excellent on-target laser 9 irradiance uniformity maintained over the duration of the pulse. Achieving this symmetry relies on maintaining an 10 energy, power, and fluence balance among all beams in a multibeam laser system. As a result of the improvements 11 described in this paper, the OMEGA 60-beam laser performance has been assessed at approximately 2% on-target 12 irradiance nonuniformity using an updated performance assessment metric that accounts for the laser diagnostic noise 13 floor. The performance is measurement-limited, prompting the need for an improved diagnostic suite. This manuscript 14 provides a comprehensive first-order assessment of extant status of on-target energy, power, and fluence uniformity 15 and explores avenues for improvements.

Diagnostics↗

Noise effects in an optical heterodyne spectrometer using tunable diode lasers

A comparison of measured and predicted signal-to-noise ratio is made in an optical heterodyne spectrometer utilizing a tunable diode laser which exhibited excess noise. It is shown that good agreement between predicted and measured signal-to-noise ratios results if excess noise effects due to tunable diode lasers are included in the predictions. The methods used to quantify excess noise and to incorporate their effects into predictions of signal-to-noise ratio are discussed.

Katzberg, S. J.↗

Transport of intensity equation: a tutorial

When it comes to “phase measurement” or “quantitative phase imaging”, many people will automatically connect them with “laser” and “interferometry”. Indeed, conventional quantitative phase imaging and phase measurement techniques generally rely on the superposition of two beams with a high degree of coherence: complex interferometric configurations, stringent requirements on the environmental stabilities, and associated laser speckle noise severely limit their applications in optical imaging and microscopy. On a different note, as one of the most well-known phase retrieval approaches, the transport of intensity equation (TIE) provides a new non-interferometric way to access quantitative phase information through intensity only measurement. Despite the insufficiency for interferometry, TIE is applicable under partially coherent illuminations (like the Köhler’s illumination in a conventional microscope), permitting optimum spatial resolution, higher signal-to-noise ratio, and better image quality. In this tutorial, we give an overview of the basic principle, research fields, and representative applications of TIE, focus particularly on optical imaging, metrology, and microscopy. The purpose of this tutorial is twofold. It should serve as a self-contained introduction to TIE for readers with little or no knowledge of TIE. On the other hand, it attempts to give an overview of recent developments in this field. These results highlight a new era in which strict coherence and interferometry are no longer prerequisites for quantitative phase imaging and diffraction tomography, paving the way toward new generation label-free three-dimensional microscopy, with applications in all branches of biomedicine.

42 ENGINEERING↗

High-resolution infrared spectroscopy of supersonically cooled singlet carbenes: Bromomethylene (HCBr) in the CH stretch region

First high-resolution spectra of cold (~35 K) singlet bromomethylene HCBr in the CH stretching (v 1 ) region from 2770 to 2850 cm-1 are reported using near quantum shot-noise limited laser absorption methods in a slit jet supersonic discharge expansion source. Three rovibrational bands are identified at high S/N (20:1 - 40:1) and rotationally assigned to i) the CH stretch fundamental (v 1 ) band $\tilde{X}$(1,0,0) ← $\tilde{X}$ (0,0,0) and ii) vibrational hot bands ($\tilde{X}$(1,1,0) ← $\tilde{X}$(0,1,0) and $\tilde{X}$(1,0,1) ← $\tilde{X}$(0,0,1)) arising from vibrationally excited HCBr populated in the discharge with single quanta in either the H–C–Br bend (v 2 ) or C–Br stretch (v 3 ) modes. Precision rotational constants are reported for a total of six states, with an experimentally determined CH stretch vibrational frequency (2799.38 cm -1 ) in good agreement with previous low-resolution fluorescence studies. Detailed analysis of the fundamental v 1 band highlights the presence of perturbations in the $\tilde{X}$(1,0,0) level, which we tentatively attribute to arise from the nearby triplet state $\tilde{a}$(0,0,1) through spin-orbit interaction or the multiple quanta $\tilde{X}$(0,2,1) singlet state via c-type Coriolis coupling. Reduced-Doppler resolution (60 MHz) in the slit-jet IR spectrometer permits clear observation of nuclear spin hyperfine structure, with experimental line shapes well reproduced by nuclear quadrupole/spin-rotation coupling constants from microwave studies. Lastly, the a-type to b-type transition intensity ratio for the fundamental CH stretch band is notably larger than predicted by a bond-dipole model, which from high level ab initio quantum calculations (CCSD(T)/PVQZ) can be attributed to vibrationally induced “charge-sloshing” of electron density along the polar C–Br bond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-low loss visible light waveguides for integrated atomic, molecular, and quantum photonics

Atomic, molecular and optical (AMO) visible light systems are the heart of precision applications including quantum, atomic clocks and precision metrology. As these systems scale in terms of number of lasers, wavelengths, and optical components, their reliability, space occupied, and power consumption will push the limits of using traditional laboratory-scale lasers and optics. Visible light photonic integration is critical to advancing AMO based sciences and applications, yet key performance aspects remain to be addressed, most notably waveguide losses and laser phase noise and stability. Additionally, a visible light integrated solution needs to be wafer-scale CMOS compatible and capable of supporting a wide array of photonic components. While the regime of ultra-low loss has been achieved at telecommunication wavelengths, progress at visible wavelengths has been limited. Here, we report the lowest waveguide losses and highest resonator Qs to date in the visible range, to the best of our knowledge. We report waveguide losses at wavelengths associated with strontium transitions in the 461 nm to 802 nm wavelength range, of 0.01 dB/cm to 0.09 dB/cm and associated intrinsic resonator Q of 60 Million to 9.5 Million, a decrease in loss by factors of 6x to 2x and increase in Q by factors of 10x to 1.5x over this visible wavelength range. Additionally, we measure an absorption limited loss and Q of 0.17 dB/m and 340 million at 674 nm. This level of performance is achieved in a wafer-scale foundry compatible Si 3 N 4 platform with a 20 nm thick core and TEOS-PECVD deposited upper cladding oxide, and enables waveguides for different wavelengths to be fabricated on the same wafer with mask-only changes per wavelength. These results represent a significant step forward in waveguide platforms that operate in the visible, opening up a wide range of integrated applications that utilize atoms, ions and molecules including sensing, navigation, metrology and clocks.

Chauhan, Nitesh↗

Radio electronics

Low noise amplifiers, laser radar optics, gas lasers and holography, and microminiaturized solid state devices for radio electronics

LIDAR↗

Signal Quality Influence on Averaging Procedure for DIAL Pollution Monitoring

Presented here is an analysis of the relative effect of each stochastic phenomenon on the accuracy of LIDAR measurements. The preferred averaging procedure to be applied is noted. The analysis takes into account the temporal correlation of the transmitted power variations which are associated with laser modal noise, short term temporal correlation of atmospheric turbulence, and 'white' additive noise. A distinction is made between two types of systems, one that transmits a sequence of pulses tuned into two wavelengths, but with a relatively large time separation, and another that transmits pulses in two wavelengths almost coincidentally. This distinction is important because the effect of speckle noise can be minimized when the pulses at two wavelengths are sent within the correlation time of the atmospheric turbulence. The presented analysis compares the signal to noise ratio in the calculation of the ratio beta (sub 1)/beta (sub 2), as achieved by using two methods of calculations: first averaging the data related to each wavelength and then taking the ratio, and first taking the ratio and then averaging. For both methods, normalization with respect to the transmitted power is considered, either prior to or after the averaging of the signals in each wavelength.

Egert, S.↗