Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Single mode wavelength control of modulated AlGaAs lasers with external and internal etalon feedback

Single mode lasing without mode hops has been obtained for VSIS and CSP laser diodes with an external etalon attached to the laser's front facet for up to an 8 C range CW and a 4 C range pulsed, with .07 nm/C tuning. Tests of thin tapered-thickness (TTT) laser diodes show CW and pulsed single mode lasing over 10 C and 2 C ranges, respectively, with .08 nm/C tuning. An analysis of the TTT structure reveals the equivalent of an internal etalon. The time-resolved pulsed behavior for both types of lasers show single mode lasing within the proper temperature ranges with minor modes present only early in the optical pulse, if at all. The external etalon produces noticeable interference fringes in the farfield pattern, while those of the TTT lasers are smooth. Ongoing CW lifetest results indicate stability to within one longitudinal mode after a few hundred hours of operation, along with at least several thousand hours lifetime.

Maynard, William L.↗

Precluding nonlinear ISI in direct detection long-haul fiber optic systems

Long-distance, high-rate fiber optic systems employing directly modulated 1.55-micron single-mode lasers and conventional single-mode fiber suffer severe intersymbol interference (ISI) with a large nonlinear component. A method of reducing the nonlinearity of the ISI, thereby making linear equalization more viable, is investigated. It is shown that the degree of nonlinearity is highly dependent on the choice of laser bias current, and that in some cases the ISI nonlinearity can be significantly reduced by biasing the laser substantially above threshold. Simulation results predict that an increase in signal-to-nonlinear-distortion ratio as high as 25 dB can be achieved for synchronously spaced samples at an optimal sampling phase by increasing the bias current from 1.2 times threshold to 3.5 times threshold. The high SDR indicates that a linear tapped delay line equalizer could be used to mitigate ISI. Furthermore, the shape of the pulse response suggests that partial response precoding and digital feedback equalization would be particularly effective for this channel.

Swenson, Norman L.↗

Construction of a 2- by 2-foot transonic adaptive-wall test section at the NASA Ames Research Center

The development of a new production-size, two-dimensional, adaptive-wall test section with ventilated walls at the NASA Ames Research Center is described. The new facility incorporates rapid closed-loop operation, computer/sensor integration, and on-line interference assessment and wall corrections. Air flow through the test section is controlled by a series of plenum compartments and three-way slide vales. A fast-scan laser velocimeter was built to measure velocity boundary conditions for the interference assessment scheme. A 15.2-cm- (6.0-in.-) chord NACA 0012 airfoil model will be used in the first experiments during calibration of the facility.

Morgan, Daniel G.↗

Diffusion filter eliminates fringe effects of coherent laser light source

Diffusion filter comprised of small particles in colloidal suspension reduces the coherence of a laser beam used as a photographic light source. Interference patterns which obscure details in photographic film are eliminated, the intensity and collimation are moderately affected.

Olsasky, M. J.↗

Laser application to measure vertical sea temperature and turbidity, design phase

An experiment to test a new method was designed, using backscattered radiation from a laser beam to measure oceanographic parameters in a fraction of a second. Tyndall, Rayleigh, Brillouin, and Raman scattering all are utilized to evaluate the parameters. A beam from a continuous argon ion laser is used together with an interferometer and interference filters to gather the information. The results are checked by direct measurements. Future shipboard and airborne experiments are described.

Hirschberg, J. G.↗

Quantitative remote measurements of pollutants from stationary sources using Raman lidar

The several advantages of Raman lidar for remote measurements of stationary source emissions were quantitatively evaluated using a calibration tank at a distance of 300 m at night. Measurements of approximately 10 to the 3rd ppm SO2 with a 12% accuracy were demonstrated in an observation time of 15 min using a 1.5-J ruby laser at 30 pulses/min, 6-m range resolution, interference filters, photon counting detection, and a 20-cm receiver. Measurement accuracy was checked by measuring known concentrations of SO2 in the tank, by tuning the interference filters through the SO2 Raman line, and by varying the CO2 concentration to very high levels during the SO2 measurements. Evaluation of the seriousness of induced fluorescence from plume aerosols failed due to the inability to simulate the plume aerosols.

Poultney, S. K.↗

Cube-Corner Retroreflector Modeling

Collection of computer programs analyzes arrays of optical cube corners used in laser ranging. Programs compute impulse-response and interference effects of reflected pulses from optical cube corners and calculates interference-effects histogram and far-field diffraction patterns.

Kirk, J. G.↗

Measurement of atmospheric OH by titration of near-IR fluorescent dyes

Recent research has shown that certain polymethine dyes can be detected at ultratrace levels (greater than or equal to 6x10(exp -14) M) in solution by fluorimetry. These detection limits are possible because of the inherent sensitivity of fluorescence techniques, because the dyes fluoresce in the near infrared region where background interference is negligible, and because powerful infrared diode lasers are now available to improve the signal to noise ratio. Other work has shown that the hydroxyl radical destroys the ability of polymethine dyes to fluoresce. These observations form the basis for a new hydroxyl radical detector that is essentially a fluorometric titrator. Theoretically, the detector should show an acceptable sensitivity and response time. Assuming that the atmospheric HO concentration is about 10(exp -11) moles m(exp -3) (i.e. 10(exp 6) molecules cm(exp -3)), then 10 L of air 'titrated' with 20 mL of 10(exp -11) M dye solution (an easily detected concentration) should result in a drop in the fluorescent signal of 50 percent - a readily detectable change. At a flow rate of 3 L min(exp -1) the sampling time would be 3 minutes. The biggest potential problem is selectivity: other oxidants may also cause the fluorescence signal to be lost. The chemistry of polymethine dyes has not been studied in detail and so no quantitative data are available. However, a survey of the literature suggests that in general HO should react up to six orders of magnitude faster than HO2 and other radicals such as RO2 and RO. It should also react much more rapidly than H2O2 and O3. Thus it may be possible to discriminate kinetically against potential interfering substances. It was shown in the laboratory that 10(exp -4) M H2O2 has little effect on the absorption spectrum of the dye IR125 over a period of hours but that the band at 780 nm is slowly lost in water over a period of days even under argon in the dark. By contrast, DMSO solutions of IR125 are stable.

Betterton, Eric A.↗

A Characterization Of Alcohol Fuel Vapor For Wavelength Modulation Spectroscopy Applied To Microgravity Flame Spread

A diode laser diagnostic is being developed for use in an ongoing investigation of flame spread in microgravity at NASA Glenn Research Center. Flame spread rates through non-homogenous gas mixtures are significantly different in a microgravity environment because of buoyancy and possibly hydrostatic pressure effects. These effects contribute to the fuel vapor concentration ahead of the flame being altered so that flame spread is more rapid in microgravity. This paper describes spectral transmission measurements made through mixtures of alcohol, water vapor, and nitrogen in a gas cell that was designed and built to allow measurements at temperatures up to 500 C. The alcohols considered are methanol, ethanol, and n-propanol. The basic technique of wavelength modulation spectroscopy for gas species measurements in microgravity was developed by Silver et al. For this technique to be applicable, one must carefully choose the spectral features over which the diode laser is modulated to provide good sensitivity and minimize interference from other molecular lines such as those in water. Because the methanol spectrum was not known with sufficient resolution in the wavelength region of interest, our first task was to perform high-resolution transmission measurements with an FTIR spectrometer for methanol vapor in nitrogen, followed recently by ethanol and n-propanol. A computer program was written to generate synthesized data to mimic that expected from the experiment using the laser diode, and results from that simulation are also presented.

Kulis, Michael J.↗

Suppression of biodynamic interference in head-tracked teleoperation

The utility of helmet-tracked sights to provide pointing commands for teleoperation of cameras, lasers, or antennas in aircraft is degraded by the presence of uncommanded, involuntary heat motion, referred to as biodynamic interference. This interference limits the achievable precision required in pointing tasks. The noise contributions due to biodynamic interference consists of an additive component which is correlated with aircraft vibration and an uncorrelated, nonadditive component, referred to as remnant. An experimental simulation study is described which investigated the improvements achievable in pointing and tracking precision using dynamic display shifting in the helmet-mounted display. The experiment was conducted in a six degree of freedom motion base simulator with an emulated helmet-mounted display. Highly experienced pilot subjects performed precision head-pointing tasks while manually flying a visual flight-path tracking task. Four schemes using adaptive and low-pass filtering of the head motion were evaluated to determine their effects on task performance and pilot workload in the presence of whole-body vibration characteristic of helicopter flight. The results indicate that, for tracking tasks involving continuously moving targets, improvements of up to 70 percent can be achieved in percent on-target dwelling time and of up to 35 percent in rms tracking error, with the adaptive plus low-pass filter configuration. The results with the same filter configuration for the task of capturing randomly-positioned, stationary targets show an increase of up to 340 percent in the number of targets captured and an improvement of up to 24 percent in the average capture time. The adaptive plus low-pass filter combination was considered to exhibit the best overall display dynamics by each of the subjects.

Lifshitz, S.↗

Coupling mechanism of gain-guided integrated semiconductor laser arrays

It is shown that a gain-guided laser array couples via propagating fields rather than the evanescent mode coupling typically responsible for directional coupling in passive (directional couplers) and active (laser array) devices. It is shown that these phase-locked modes exhibit an interference pattern, in the junction plane, which arises from the curvature of the phase fronts of optical fields of the interacting lasers. The experimental results are interpreted with the aid of a simple theoretical model, and the effect of the observed mode pattern on the coupling of gain-guided lasers is discussed.

Kapon, E.↗

Simultaneous amplification of terahertz difference frequencies by an injection-seeded semiconductor laser amplifier at 850 nm

Two-frequency operation of an 850 nm semiconductor optical amplifier was achieved by simultaneously injection seeding it with two diode lasers. The two frequencies could be independently amplified without strong interference when they were separated by more than 10 GHz, and the spectral purity was preserved by the amplification process. At frequency differences below 10 GHz, unbalanced two-frequency output was observed, which can be explained by a two-mode interaction driven by the refractive index modulation at the beat frequency. The laser system is suitable for the difference-frequency generation of coherent terahertz radiation in ultra-fast photoconductors or nonlinear optical media.

NASA Discipline Exobiology↗

Optical Tweezer Assembly and Calibration

An Optical Tweezer, as the name implies, is a useful tool for precision manipulation of micro and nano scale objects. Using the principle of electromagnetic radiation pressure, an optical tweezer employs a tightly focused laser beam to trap and position objects of various shapes and sizes. These devices can trap micrometer and nanometer sized objects. An exciting possibility for optical tweezers is its future potential to manipulate and assemble micro and nano sized sensors. A typical optical tweezer makes use of the following components: laser, mirrors, lenses, a high quality microscope, stage, Charge Coupled Device (CCD) camera, TV monitor and Position Sensitive Detectors (PSDs). The laser wavelength employed is typically in the visible or infrared spectrum. The laser beam is directed via mirrors and lenses into the microscope. It is then tightly focused by a high magnification, high numerical aperture microscope objective into the sample slide, which is mounted on a translating stage. The sample slide contains a sealed, small volume of fluid that the objects are suspended in. The most common objects trapped by optical tweezers are dielectric spheres. When trapped, a sphere will literally snap into and center itself in the laser beam. The PSD s are mounted in such a way to receive the backscatter after the beam has passed through the trap. PSD s used with the Differential Interference Contrast (DIC) technique provide highly precise data. Most optical tweezers employ lasers with power levels ranging from 10 to 100 miliwatts. Typical forces exerted on trapped objects are in the pico-newton range. When PSDs are employed, object movement can be resolved on a nanometer scale in a time range of milliseconds. Such accuracy, however, can only by utilized by calibrating the optical tweezer. Fortunately, an optical tweezer can be modeled accurately as a simple spring. This allows Hook s Law to be used. My goal this summer at NASA Glenn Research Center is the assembly and calibration of an optical tweezer setup in the Instrumentation and Controls Division (5520). I am utilizing a custom LabVIEW Virtual Instrument program for data collection and microscope stage control. Helping me in my assignment are the following people: Mentor Susan Wrbanek (5520), Dr. Baha Jassemnejad (UCO) and Technicians Ken Weiland (7650) and James Williams (7650). Without their help, my task would not be possible.

Collins, Timothy M.↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

Ten years in the making the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center is designed to be a cooperative analytical facility where novel techniques are developed and performed. Our team works collaboratively to operate this integrated lab suite comprising sample preparation, metal-free clean chemistry, and mass spectrometers to measure a wide variety of elements and isotopes in astromaterials. Contamination control is enacted throughout by a positive pressure cascade of HEPA filtered air, weekly surface cleaning and particle counting. Astromaterials processing is performed with application-specific mortar and pestles, heavy liquid separation, a Frantz magnetic separator, as well as hand-picking using optical microscopes in laminar flow boxes. Microsampling is also carried out using a New Wave MicroMill. Elements for isotopic analysis are isolated from acid-digested samples using ion-exchange chromatography. Cross-contamination is minimized with dedicated laminar flow boxes and labware for different purification protocols. Instrumentation includes a ThermoFisher Element XR inductively coupled plasma mass spectrometer (ICP-MS) for quantification of elemental concentrations in dissolved sample solutions. For in situ analysis, a Teledyne Photon Machines Analyte Excite+ laser ablation system is coupled to the Element XR. The ThermoFisher Triton thermal ionization mass spectrometer (TIMS) is used to measure the isotopic composition of elements such as CA, K, Cr, Rb, Sr, Sm, Nd at high precision in processed samples. For a more diverse range of isotopic analyses, CICG houses a Nu Sapphire 1700 multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), which is a large geometry instrument with a multi-pole collision cell for interference removal. An Applied Spectra Instruments J200 femto-second laser is planned for install this Fall and will be coupled to the Nu Sapphire 1700. NASA’s Internal Scientist Funding Model (ISFM)supports this facility. Advanced analytical geochemistry techniques are applied to targeted astromaterials to address important problems in planetary sciences, with a longer-term goal of preparing for samples collected and returned by space missions. CICG is open to collaborations on projects that utilize the facility’s unique capabilities and are within its research scope. We are particularly eager to support and share expertise with the next generation of planetary scientists.

Justin I Simon↗

Laser angle measurement system

The design and fabrication of a laser angle measurement system is described. The instrument is a fringe counting interferometer that monitors the pitch attitude of a model in a wind tunnel. A laser source and detector are mounted above the mode. Interference fringes are generated by a small passive element on the model. The fringe count is accumulated and displayed by a processor in the wind tunnel control room. Optical and electrical schematics, system maintenance and operation procedures are included, and the results of a demonstration test are given.

Pond, C. R.↗

Measurement of ultrasonic fields in transparent media using a scanning differential interferometer

An experimental system for the detection of three dimensional acoustic fields in optically transparent media using a dual beam differential interferometer is described. In this system, two coherent, parallel, focused laser beams are passed through the specimen and the interference fringe pattern which results when these beams are combined shifts linearly by an amount which is related to the optical pathlength difference between the two beams. It is shown that for small signals, the detector output is directly proportional to the amplitude of the acoustic field integrated along the optical beam path through the specimen. A water tank and motorized optical platform were constructed to allow these dual beams to be scanned through an ultrasonic field generated by a piezoelectric transducer at various distances from the transducer. Scan data for the near, Fresnel, and far zones of a uniform, circular transducer are presented and an algorithm for constructing the radial field profile from this integrated optical data, assuming cylindrical symmetry, is described.

Dockery, G. D.↗

Laser angle sensor

A laser angle measurement system was designed and fabricated for NASA Langley Research Center. The instrument is a fringe counting interferometer that monitors the pitch attitude of a model in a wind tunnel. A laser source and detector are mounted above the model. Interference fringes are generated by a small passive element on the model. The fringe count is accumulated and displayed by a processor in the wind tunnel control room. This report includes optical and electrical schematics, system maintenance and operation procedures.

Pond, C. R.↗

High-Speed Self-Aligned Focusing Schlieren and Background-Oriented Schlieren with Pulsed Laser Illumination

Laser light sources are commonly used in schlieren-based flow visualization techniques that are in development at NASA Langley Research Center. Of particular interest are high-intensity, low coherence sources that allow for high signal-to-noise schlieren imagery to be acquired without the laser speckle that typically occurs as a result of interference. Results from a self-aligned focusing schlieren system developed at NASA Langley and a background-oriented schlieren system are presented to highlight the effectiveness of these sources.

Schlieren↗