Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kWh”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Engineering a Novel High Temperature Metal Hydride Thermochemical Storage

The goal of this project is to engineer novel metal hydride-based thermochemical energy storage (TCES) that exceeds the DOE’s performance and cost targets. During this three-year project, we aimed to design, fabricate and validate the TCES system with a bed sized to store 240 kWh of heat during 8 hours. Large-scale testing will demonstrate the metal hydride TCES capacity of 240 kWh with a 30 kW heat rate, with an efficiency projected to be >95% to validate a commercial path forward.

14 SOLAR ENERGY↗

Chippewa Cree Residential Solar Deployment Project

The overall project goal was to install clean energy systems in order to achieve the Chippewa Cree Tribe’s long-term goal of energy self-sufficiency, environmental protection, and better lives for our tribal members and community. This would be the first solar deployment project on the Rocky Boy’s Reservation. With 50% of the funding provided by the Office of Indian Energy, the Chippewa Cree Tribe teamed up with GRID Alternatives to install six grid-tied, solar electric systems for low-income single-family homes. The systems installed were estimated to provide 4,400 kWh annually with an estimated $451 dollar savings per household. After monitoring the systems for a year, we were almost able to obtain our goal with an average of 3,971 kWh and a $419 dollar average savings per household. We would have exceeded our goal but one of the units was without power for the majority of the year bringing down the average significantly. Another major component to the grant was workforce development. GRID Alternatives supplied training for students from Stone Child College on the installation process. With the collaboration and planning efforts from all of the departments, the installations were completed in October of 2016. Throughout the report you will see the six installations are diverse, and each needs to be considered in the context of the individual family structure, size, and energy consumption habits.

14 SOLAR ENERGY↗

Estimating the cost and energy demand of producing lithium manganese oxide for Li-ion batteries

Lithium Manganese Oxide (LMO) is one of the important cathode active materials used in lithium ion batteries of several electric vehicles. In this paper, the production of LMO cathode material for use in lithium-ion batteries is studied. Spreadsheet-based process models have been set up to estimate and analyze the factors affecting the cost of manufacturing, the energy demand, and the environmental impact. Two processes based on the solid-state synthesis method and a sol-gel method have been explored. Results show that the solid-state process is more cost-effective because of its lower cost of raw materials. The production cost for a solid-state process is $7 kg -1 and requires 6 kWh·kg -1 of energy. The pack level cost of electric vehicle battery using LMO as a primary active material is studied as a function of LMO production cost and other parameters. The potential for reducing the cost of automotive batteries to $100 per kWh is explored in terms of LMO price and plant production volume (economy of scale), using Argonne’s BatPaC spreadsheet tool.

25 ENERGY STORAGE↗

Comprehensive Assessment of On-And Off-Board Vehicle-To-Grid Technology Performance and Impacts on Battery and the Grid

This project defined, developed, and tested the open standards-based requirements, engineering design and system integration of on and off-vehicle Vehicle-to-Grid technologies both on the grid and on the PEV, to assess their effectiveness in implementing the use cases that create value for the grid, which in turn, can be passed on to the ratepayers and the PEV owners. The project comprised of three key categories of work and four key sub-areas of work. The three key categories were: On-Vehicle V2G, Off-Vehicle V2G, and impact of V2G operation on the battery capacity degradation. The four key sub-areas of work under each of these categories were: defining requirements, implementing the technology, performing system integration testing, and estimating the value of each of the grid services under specific assumptions, on a per-vehicle and on an aggregated basis. The technical implementation demonstrated the validity of standards-based approach to grid integration that led to interoperability, in addition to assessing the operational details with grid constraints imposed at the transformer level. The technology implementation also identified the subtle gaps in the standards definition to close the feedback loop on the accuracy of the standards as written, which are being implemented as revisions to the appropriate protocols. The battery impacts assessment developed a test cycle that the batteries from a real PHEV were subjected to for both the mobility-only and mobility with V2G specific energy cycling. While the battery impact results show a clear incremental degradation in response to additional throughput for V2G application purposes, the amount of additional kWh that can be made available without exceeding the end-of-life capacity definition of the battery at its 10-year warranty period was found to be significant. Given that the PEV battery being exercised during testing was a PHEV battery (smaller energy capacity), and 44% of its usable energy (i.e., SOC) was utilized daily for V2G applications, the EVs with much larger batteries will fare much better, either in terms of extracting more value in terms of incremental kWh for V2G, or in terms of relative incremental degradation of the capacity through the battery lifespan. Further, this battery was the second-generation Lithium-Ion chemistry circa 2015, which is at least two generations ago. Continual improvements in electrochemistry and manufacturing techniques as well as on-board capacity will enable the future batteries to provide even more energy for non-mobility-related services. Finally, the valuation of V2G energy services at the premise, distribution, and the ISO/market level was carried out for both the on-vehicle and off-vehicle cases, to understand both the GHG mitigation and operational efficiency improvements in quantitative terms. The analysis indicates that between $\$400$ and $\$1400$ per year of total value to the grid can be realized. When netted of costs to implement V2G either on or off-vehicle, the net value is available to be shared between the ratepayers and the EV owners. Over the life of the EV, therefore, this value becomes significant and can easily provide both ratepayer and EV owner benefits more than the cost of the equipment, either on or off-board, in addition to providing GHG mitigation benefits both on the grid and on the mobility sides. For these benefits to accrue, the key learnings from both the on- and off-vehicle V2G parts of the project indicate the need for at-scale demonstrations through involvement of real EV owners to validate both the technical feasibility, interoperability, as well as real grid benefits by performing extensive data collection and analysis. This will help inform the grid planners, the program designs, and tariff designers, as well as automotive and equipment manufacturers how best to create their products to maximize grid, ratepayer, and EV owner value.

30 DIRECT ENERGY CONVERSION↗

Senior Housing Complex Energy Efficiency and Solar Energy Project

As part of a longer-term energy efficiency and solar development program on the Coeur d'Alene reservation, the Coeur d'Alene Tribe completed energy efficiency measures and deployed a solar photovoltaic system at its Senior Housing Complex. The project generated nearly 68,000 kWh of solar energy in its first year, and reduced energy used at the senior housing complex by 95,192 kWh, saving $7,144.56 in energy costs, and saving 48.1 metric tons of carbon dioxide.

14 SOLAR ENERGY↗

Reducing Grid Costs while Abating Emissions: Opportunities for Flexible Building Loads

This study evaluates the value of technology-agnostic, shiftable flexible building loads in modeled 2030 and 2040 U.S. grids for four types of customers under three potential aggregated distributed energy resources programs. The value examined includes monetary value from providing grid services (e.g., energy, capacity, flexibility reserve, regulation reserve, contingency reserve) and from reducing greenhouse gas emissions. By comparing more than 845,164,800 simulated shifting opportunities, the study finds that the timing of consumption is critical for profit-driven customers. A program that is activated for 30 critical hours of system operation can result in to $73 per year in revenue for 1 kWh of shiftable load. Emission reduction, on the other hand, is best accumulated through a year-round program: 1 kWh of shiftable load can lead to up to 487.9 kg CO2e carbon reduction per year. The report also provides detailed insights on the trade-off between revenue and emissions, regional variation, short- versus medium- term value, and impacts from various building flexibility parameters, such as shifting window and dissipation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

San Xavier District Solar Energy Project for Administration Building and Education Center

The San Xavier District of the Tohono O’odham Nation (District) developed grid-tied solar photovoltaic (PV) systems for two tribal buildings: the San Xavier District Administration Building and Education Center. For the Administration Building, an approximately 182-kilowatt (kW) solar PV system is projected to produce roughly 310,000 kilowatt-hours (kWh) per year and displace about 80% of the energy use of the building. For the Education Center, an approximately 73.5-kw system is projected to produce roughly 130,000 kWh per year and displace about 95% of the building’s energy use. The anticipated 25-year cost savings from the combined 255-kW systems are estimated to be approximately $1,750,000 and $820,000 for the Administration Building and the Education Center, respectively.

14 SOLAR ENERGY↗

THERMS Technology Commercialization Fund Final Report

The technology commercialization fund assisted with the design and development of an intermediate scale packed be thermal energy storage system. Presented in this final report is the design, testing, and modeling of a 100 kWh th radial packed-bed. Air is used as a heat transfer fluid and 3/8” pea gravel is used as the storage medium. Testing has demonstrated the formation of a thermocline within the packed-bed. An air charging temperature of 450 °C was achieved resulting in a charging power of 26.5 kWh th . The radial packed-bed was charged for 5 hours and discharged for 5 hours. Minimal temperature variation was observed at the bottom, middle, and top axial locations of the radial packed-bed which suggests that buoyancy and hydrodynamics in the injection well had a minimal effect on the uniformity of air flow through the bed during charging and discharging. This indicates that the forced convection in a radial direction is dominating the flow regime compared to the buoyancy. The findings of this study suggest an increased air duct diameter through the air heater will increase the charging temperature and increase air mass flow through the system. Increased mass flow through the packed-bed is hypothesized to shorten the thermocline length. Modeled and measured results are compared, and it is here determined that a more comprehensive CFD model will aid in the understanding of air flow and thermocline evolution within the packed-bed.

25 ENERGY STORAGE↗

Low Wind Speed Turbine Developments in Convoloid Gearing: Final Technical Report, June 2005 - October 2008

This report presents the results of a study conducted by Genesis Partners LP as part of the United States Department of Energy Wind Energy Research Program to develop wind technology that will enable wind systems to compete in regions having low wind speeds. The purpose of the program is to reduce the cost of electricity from large wind systems in areas having Class 4 winds to 3 cents per kWh for onshore systems or 5 cents per kWh for offshore systems. This work builds upon previous activities under the WindPACT project, the Next Generation Turbine project, and Phase I of the Low Wind Speed Turbine (LWST) project. This project is concerned with the development of more cost-effective gearing for speed increasers for wind turbines.

108-KW WIND TURBINE GEARBOXES↗

Improving the Power Outage Resilience of Buildings with Solar PV through the Use of Battery Systems and EV Energy Storage

Buildings with solar photovoltaic (PV) generation and a stationary battery energy storage system (BESS) may self-sustain an uninterrupted full-level electricity supply during power outages. The duration of off-grid operation is dependent on the time of the power fault and the capabilities of the home energy management system (HEMS). In this paper, building resilience is quantified by analyzing the self-sustainment duration for all possible power outages throughout an entire year. An evaluation method is proposed and exercised on a reference house in California climate zone 9 for which the detailed electricity usage is simulated using the EnergyPlus software. The influence of factors such as energy use behavioral patterns, energy storage capacity from the BESS, and an electric vehicle (EV) battery on the building resilience is evaluated. Varying combinations of energy storage and controllable loads are studied for optimally improved resilience based on user preferences. It is shown that for the target home and region with a solar PV system of 7.2 kW, a BESS with a capacity of 11 kWh, and an EV with a battery of 80 kWh permanently connected to the home, off-grid self-sustained full operation is guaranteed for at least 72 h.

14 SOLAR ENERGY↗

Binder Jet Additive Manufacturing Process and Material Characterization for High Temperature Heat Exchangers Used in Concentrated Solar Power Applications

The U.S. Department of Energy’s (DOE) Sunshot 2030 initiative has a goal of reducing the cost of concentrating solar power (CSP) to 5 cents per kWh for baseload power plants. One of the potential pathways to this goal includes a reduction in the cost of the supercritical CO2 (sCO2) power block to 0.9 cents per kWh. Recuperators—high and low temperatures, used in the sCO2 power cycle, contribute to >50% of the cost of the power cycle. This work studies the feasibility towards a ≥10% cost reduction for High Temperature Recuperators (HTR) used in the sCO2 power cycle. One way to address the cost reduction is by leveraging low-cost additive manufacturing, specifically, Binder Jet Additive Manufacturing (BJAM) to 3D print HTRs at scale. This study focuses on the development of a BJAM process towards 3D printing HTR cores using Stainless Steel alloy 316L (SS316L). To evaluate the suitability of the BJ process towards the HTR, high level specifications of the application are translated to materials capability requirements. Subsequently, at-temperature materials testing is conducted on as-printed and sintered additively manufactured coupons. Data from the coupons are compared against cast and wrought SS316L data obtained from the literature. Results show that the tensile properties from the BJ process compare well against cast properties. Furthermore, a baseline analysis of creep testing data is established for the BJ process, and insights are drawn from the results towards future improvements of the process.

14 SOLAR ENERGY↗

A comparison of GaAs and Si hybrid solar power systems

An analytical comparison of energy output from various silicon and gallium arsenide hybrid solar power systems, producing electric power and also thermal power for heating or cooling, is made. System performance indices in terms of capital cost, peak power, total power output, and electric power were evaluated. Limiting values for annual energy production from GaAs and Si solar concentrator systems were estimated to be 2 cents and 6.8 cents per kWh for GaAs concentrator systems and between 2.5 cents and 11 cents per kWh for Si concentrator systems.

Heinbockel, J. H.↗

Solar cells for solar power satellites

The concept of a solar-cell array for a solar power satellite is developed to permit evaluation of its economic feasibility for generating power for delivery to public utilities on earth. Gallium arsenide solar cells were considered but it could not be assured that the world gallium resources could support constructions of two solar power satellites per year. Therefore, for preliminary design an array blanket made from 5 by 10 cm silicon solar cells, 50 microns thick, and electrostatically bonded between borosilicate glass sheets was adopted. In annealing experiments, a radiated 50 microns thick cell was restored to its initial performance in a 500 C. Solar-cell efficiency effects significantly the solar power satellite mass, which varies from 90,000 metric tons for 20 percent cells to 120,000 metric tons for 12 percent cells. The anticipated cost of delivered power, based on 1977 dollars, varies from 4 cents per kWh with 18 percent cells, to 5 cents per kWh for 12 percent efficient cells.

Oman, H.↗

The LiAl/FeS2 battery power source for the future

Advanced high power density rechargeable batteries are currently under development. These batteries have the potential of greatly increasing the power and energy densities available for space applications. Depending on whether the system is optimized for high power or high energy, values up to 150 Wh/kg and 2100 W/kg (including hardware) are projected. This is due to the fact that the system uses a high conductivity molten salt electrolyte. The electrolyte also serves as a separator layer with unlimited freeze thaw capabilities. Life of 1000 cycles and ten calendar years is projected. The electrochemistry consists of a lithium aluminum alloy negative electrode, iron disulfide positive electrode, and magnesium oxide powder immobilized molten salt electrolyte. Processed powders are cold compacted into circular discs which are assembled into bipolar cell hardware with peripheral ceramic salts. The culmination of the work will be a high energy battery of 40 kWh and a high power battery of 28 kWh.

Briscoe, J. Douglass↗

Renewable Energy at NASA's Johnson Space Center

NASA's Johnson Space Center has implemented a great number of renewable energy systems. Renewable energy systems are necessary to research and implement if we humans are expected to continue to grow and thrive on this planet. These systems generate energy using renewable sources - water, wind, sun - things that we will not run out of. Johnson Space Center is helping to pave the way by installing and studying various renewable energy systems. The objective of this report will be to examine the completed renewable energy projects at NASA's Johnson Space Center for a time span of ten years, beginning in 2003 and ending in early 2014. This report will analyze the success of each project based on actual vs. projected savings and actual vs. projected efficiency. Additionally, both positive and negative experiences are documented so that lessons may be learned from past experiences. NASA is incorporating renewable energy wherever it can, including into buildings. According to the 2012 JSC Annual Sustainability Report, there are 321,660 square feet of green building space on JSC's campus. The two projects discussed here are major contributors to that statistic. These buildings were designed to meet various Leadership in Energy and Environmental Design (LEED) Certification criteria. LEED Certified buildings use 30 to 50 percent less energy and water compared to non-LEED buildings. The objectives of this project were to examine data from the renewable energy systems in two of the green buildings onsite - Building 12 and Building 20. In Building 12, data was examined from the solar photovoltaic arrays. In Building 20, data was examined from the solar water heater system. By examining the data from the two buildings, it could be determined if the renewable energy systems are operating efficiently. Objectives In Building 12, the data from the solar photovoltaic arrays shows that the system is continuously collecting energy from the sun, as shown by the graph below. Building 12 has two solar inverters, located on the second floor, that collected the data from the solar photovoltaic arrays. The data displayed here is the total energy produced by the system. These are cumulative amounts, so the last point on the graph shows all of the energy collected from the system since the start of its operation. The data shown here was manually collected from the solar inverters. However, the data is also automatically recorded through EBI. Through analysis of both sets of data it was determined that the EBI data was faulty. For example, from the manually collected data it can be determined that a total of 73 kWh of energy was collected between the dates of 1/16/2014 – 1/22/2014. The EBI data reports that approximately 17800 kWh of energy was collected during the same time frame. Not only does this exceed the time frame examined, but it also exceeds the total energy collected from the start of collection as recorded from the inverters. This leads to the belief that there is a malfunction with the automatic recording of the energy. In Building 20, data was examined from the solar water heater dating back many months and found that the pump for the solar water heater system was not operating properly, as exhibited in the graph shown below. The pump operates on a solar energy system, meaning that it collects energy throughout the day from the sun. Because of this, the system would stop operating shortly after the sun set because of a lack of sunlight. At that point, the graph should show a zero flow rate, but as exhibited in the graph below, that is not the case. It is clearly shown that the pump is continuously operating, even during the night. It was also observed that the majority of the time the pump would not turn on at all, despite good weather conditions. This led to the conclusion that the pump is malfunctioning, and needs to be examined and fixed.

McDowall, Lindsay↗

Measuring Degradation of Fielded Systems on an Ongoing Basis with RdTools

The solar investment community needs up-to-date and data-derived system degradation rates to use in financial models that calculate the risk and expectation of energy revenue. To date, the majority of financial models choose degradation rates from past studies that are limited and may not be representative of future solar assets (systems) they are financing. As the solar industry expands in all sectors (residential, commercial, and utility), there is a growing amount of energy production available to analyze. With the help of the open source degradation analysis code (RdTools) it is now possible to derive degradation on an ongoing basis and continuously provide up-to-date durability statistics to the investment community. Ongoing and accurate statistics of fielded photovoltaic systems allows financial stakeholders to constrain energy revenue projections, lower financial risk, and increase the bankability of solar. This poster will present considerations and software engineering best practices to encourage data owners to measure degradation of their own photovoltaic assets on an ongoing basis. This poster will also preview an upcoming DOE-funded kWh Analytics degradation project which involves applying RdTools analysis on kWh Analytics’ industry database, aggregating results across variables such as weather, hardware, system configurations etc., and sharing the aggregated results with the broader community.

14 SOLAR ENERGY↗

Deciphering Degradation: Machine Learning on Real-World Performance Data

The solar investment community is in need of up-to-date and data-derived system degradation rates to use in financial models that calculate the risk and expectation of energy revenue. To date, financial models choose degradation rates from past studies that are limited and may not be representative of solar projects in development today. As the solar industry expands in all sectors (residential, commercial, and utility), there is a growing amount of energy generation data available to analyze. With the help of the open source degradation analysis code (RdTools) it is now possible to derive degradation on an ongoing basis and continuously provide up-to-date durability statistics to the investment community. Ongoing and accurate statistics of fielded photovoltaic systems allows financial stakeholders to constrain energy revenue projections, lower financial risk, and increase the bankability of solar. This presentation will provide a mid-term progress update on a 2 year SETO-funded degradation project that involves applying RdTools analysis on kWh Analytics’ industry database. With results from the RdTools analysis in hand, machine learning methods are employed to quantify how much variance of system performance degradation can be explained by predictor variables such as environmental factors, equipment bill of materials characteristics, and system design information. The goal of this presentation is to promote the usage of RdTools on an ongoing to data owners and to solicit feedback from researchers and stakeholders on how to maximize impact of the SETO-funded kWh Analytics degradation project.

14 SOLAR ENERGY↗

NCSU Industrial Assessment Center

Renewable energy technologies are becoming more attractive and gaining more attention as the world becomes increasingly aware of the negative impacts of global warming and greenhouse gas (GHG) emissions. Two such emerging technologies are geothermal heat pumps (GHP) and solar thermal heating which can be used for heating and cooling of buildings. GHP systems are a well-studied technology that have been proven to be more efficient than traditional air-source heat pumps for space conditioning of buildings. Solar thermal heating has become more common as a way to heat domestic hot water (DHW) in homes, but the two technologies are not often combined. This study presents the findings of combining an open-loop GHP with 100 ft2 of flat plate solar thermal panels and a 5,655-gallon sensible water storage tank for space heating and DHW heating needs of a residential home in Bozeman, MT, USA. The goal of this system was to use energy from the solar panels and storage tank first to decrease pumping energy from the GHP well. The open loop system was designed to be a backup system to the solar thermal panels and sensible storage tank. An actual home was modeled to determine potential energy and cost savings of such a system compared to a traditional propane boiler. Then, a case study was performed on the installed system from January to June 2021. Results obtained from April 2nd to June 5th, 2021 indicated that the combination system supplied all necessary heat, and that heat was supplied from the thermal storage tank 55% of the time. This represents a savings of 330 kWh of energy and $36 compared to operating just the open loop geothermal system. From April 2nd to June 5th the combination system consumed a total of 2,510 kWh of energy and cost $274 to operate. Based on data obtained, there is significant potential for energy savings compared to a propane boiler, however only small potential for cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗