High-resolution time-resolved experiments on mixing and entrainment of buoyant jets in stratified environments

Fluid jets interacting with a stratified layer play an important role in the safety of several reactor designs. In the containment of nuclear power plants, fluid jets dominate the transport and mixing of gaseous species and consequent hydrogen distribution in case of a severe accident. The mixing phenomena in the containment are driven by buoyant high-momentum injections (jets) and low momentum injection plumes. Mixing near the postulated break is initially dominated by high flow velocities. Plumes with moderate flow velocities are instead relevant in the break compartment during the long-term pressurization phase, or in any of the apertures between two connected compartments if the mass flows are sufficiently high and the density differences between efflux and ambient are sufficiently low. Phenomena of interest include free plumes (as produced by the efflux from the break compartment in a larger room or directly from a break flow), wall plumes (such those produced by low mass flows through inter-compartment apertures), and propagating stratification fronts in the ambient (for any stably stratified conditions). These phenomena have been highly ranked about nuclear reactor design, especially regarding of safety protocols. During a Pressurized Thermal Shock (PTS) scenario, the interaction between the cold ECCS injection plume and the stratified fluid present in the cold (or hot) leg is important in order to determine the temperature at the time-dependent temperature at the inlet of the reactor pressure vessel (RPV) and the potential to cause a thermal shock on the RPV wall. In sodium-cooled fast reactors (SFRs), core channels are typically hydro-dynamically isolated so that there exists a considerable temperature variation at the exit of adjacent fuel assemblies. All the above phenomena are characterized by the interaction of buoyant jets with the stratified flow. In stratified layers baroclinic forces create significant redistribution of turbulent kinetic energy and scales, which leads to anisotropy. This important physical phenomenon is highly three dimensional and is challenging to capture even with high-fidelity CFD simulations, due in part to lack of sufficiently resolved validation data. Furthermore, the experimental data available in the open literature do not feature the level of fidelity needed for an extensive validation of turbulence models in lower order CFD. To shed new lights into the crucial phenomena object of the present research project, it was proposed to conduct coordinated experiments and simulations at the University of Michigan and the George Washington University. The project has resulted in an experimental database of high-resolution time-resolved measurements of jets in uniform and stratified environments. The novel experimental data will be used to validate computational fluid dynamic (CFD) codes, including both Large Eddy Simulations (LES) and unsteady Reynolds-averaged Navier-Stokes equations (URANS) methodologies. In the Experimental and Multiphase flow (ECMF) laboratory at Univerisity of Michigan, we built two experimental facilities to investigate also the effect of scaling. The first facility, DESTROJER (DEnsity Stratified Turbulent ROund free Jet ExpeRiment), featuring a contoured jet nozzle with a diameter of D=12.7mm and a 1m×1m×1m cubic tank, which is made of acrylic glass for optical access. The ratio between the tank width and the nozzle diameter is equal to 78, which ensures that there is no direct interaction between the jet and the side walls. A second, modular experimental facility, features three different tank sizes of size 10×10×30, 20×20×30, 30×30×30 cm3 respectively (all tanks have the same height of 30 cm), and a jet diameter of 2mm. For the modular facility, tank-to-nozzle ratio of 50, 100, and 150 are obtained respectively. Experiments with different-density jet impactions and sharp interface with a density difference of 3.16% In the Laboratory at George Washington University, complementary experiments have been carried out at a facility featuring the same dimensions as DESTROYER. Experiments with different jet diameters have been carried out as well. High-resolution time-resolved measurements have been performed at all facilities using high-speed particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF). In this way, simultaneous measurements of velocity and density fields have been carried out. At the University of Michigan, wire-mesh sensors have been designed and built to gather high-resolution, time-dependent data of the stratified front in the tank. These measurements are important to provide accurate initial conditions for the CFD simulations. An important outcome of the project has been the development of novel techniques to achieve refractive index matching (RIM) of acqueous solutions with high density differences. RIM is crucial if optical techniques such as PIV are used to measure velocity fields. Previous to this project, experiments up to 3% density difference had been reported in the literature. With the methodology developed in this project, we have been able to push the envelop to density differences up to 9%. The experiments have been used to validate Reynolds Averaged Navier-Stokes (RANS) turbulence models and Large Eddy Simulations (LES) models. Both NEK5000 and the commercial CFD code STAR-CCM+ have been used. The experimental data will be made available to the community through the NE-KAMS databasehave been successfully conducted in the scaled facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Laser Doppler Velocimeter measurements in a 3-D impinging twin-jet fountain flow

Mean velocity and turbulence measurements were conducted on the three dimensional fountain flow field generated by the impingement of two axisymmetric jets on a ground plane with application to vertical takeoff and landing (VTOL) aircraft. The basic instantaneous velocity data were obtained using a two component laser Doppler velocimeter in a plane connecting the nozzle centerlines at different heights above the ground emphasizing the jet impingement region and the fountain upwash region formed by the collision of the wall jets. The distribution of mean velocity components and turbulence quantities, including the turbulence intensity and the Reynolds shear stress, were derived from the basic velocity data. Detailed studies of the characteristics of the fountain revealed self-similarity in the mean velocity and turbulence profiles across the fountain. The spread and mean velocity decay characteristics of the fountain were established. Turbulence intensities of the order of 50% were observed in the fountain.

Saripalli, K. R.↗

Afterglows from Binary Neutron Star Postmerger Systems Embedded in Active Galactic Nuclei Disks

Abstract The observability of afterglows from binary neutron star mergers occurring within active galactic nuclei (AGN) disks is investigated. We perform 3D GRMHD simulations of a postmerger system and follow the jet launched from the compact object. We use semianalytic techniques to study the propagation of the blast wave powered by the jet through an AGN disk-like external environment, extending to distances beyond the disk scale height. The synchrotron emission produced by the jet-driven forward shock is calculated to obtain the afterglow emission. The observability of this emission at different frequencies is assessed by comparing it to the quiescent AGN emission. In the scenarios where the afterglow could temporarily outshine the AGN, we find that detection will be more feasible at higher frequencies (≳10 14 Hz) and the electromagnetic counterpart could manifest as a fast variability in the AGN emission, on timescales less than a day.

79 ASTRONOMY AND ASTROPHYSICS↗

ELLERMAN BOMBS AT HIGH RESOLUTION. I. MORPHOLOGICAL EVIDENCE FOR PHOTOSPHERIC RECONNECTION

High-resolution imaging-spectroscopy movies of solar active region NOAA 10998 obtained with the Crisp Imaging Spectropolarimeter at the Swedish 1-m Solar Telescope show very bright, rapidly flickering, flame-like features that appear intermittently in the wings of the Balmer H{alpha} line in a region with moat flows and likely some flux emergence. They show up at regular H{alpha} blue-wing bright points that outline the magnetic network, but flare upward with much larger brightness and distinct 'jet' morphology seen from aside in the limbward view of these movies. We classify these features as Ellerman bombs and present a morphological study of their appearance at the unprecedented spatial, temporal, and spectral resolution of these observations. The bombs appear along the magnetic network with footpoint extents up to 900 km. They show apparent travel away from the spot along the pre-existing network at speeds of about 1 km s{sup -1}. The bombs flare repetitively with much rapid variation at timescales of seconds only, in the form of upward jet-shaped brightness features. These reach heights of 600-1200 km and tend to show blueshifts; some show bi-directional Doppler signature and some seem accompanied with an H{alpha} surge. They are not seen in the core of H{alpha} due to shielding by overlying chromospheric fibrils. The network where they originate has normal properties. The morphology of these jets strongly supports deep-seated photospheric reconnection of emergent or moat-driven magnetic flux with pre-existing strong vertical network fields as the mechanism underlying the Ellerman bomb phenomenon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Acoustic characteristics and dynamic structural loading of an ASTOVL aircraft in hover

Measurements of surface dynamic loading and freestream acoustics were made for an ASTOVL model in hover, to quantify the effects of elevated temperature on the acoustic field and surface loading. Data were acquired for a many combinations of operating parameters: model height above the ground plane, nozzle pressure ratio, and jet exit stagnation temperature. For many conditions, strong tones were observed, with amplitudes up to 150 dB. The frequencies of the strongest tones were well predicted by a model assuming feedback between the nozzle exit and the ground plane. The model also accounts for many of the variations in frequency observed with changes in model height, nozzle pressure ratio, and jet temperature. Broadband sound pressure levels up to 170 dB were also recorded. The maximum levels occurred at approximately 3 equivalent jet diameters above the ground plane. For the majority of the cases, the increase in noise due to temperature was less than expected based on free jet correlations.

Mitchell, L. K.↗

Causes of and Solutions to Wind Speed Bias in NREL's 2020 Offshore Wind Resource Assessment for the California Pacific Outer Continental Shelf

This report provides the results of a detailed analysis into the causes of high wind speed bias in the 20-year wind resource data set for offshore California the National Renewable Energy Laboratory (NREL) released in 2020, herein called CA20. The data set was developed using the state-of-the-art Weather Research and Forecasting (WRF) model. Notably, no floating lidars were available at the time in offshore California to validate offshore hub-height wind speeds. In late 2020, the Pacific Northwest National Laboratory (PNNL) deployed two floating lidars in the California outer continental shelf (OCS), near the Bureau of Ocean Energy Management (BOEM) call areas of Humboldt and Morro Bay. Using these observations through 2021, NREL found considerable bias in modeled hub-height winds at both locations: up to +2 m/s at Humboldt over a 6-month period, and up to +1 m/s at Morro Bay over a one-year period. Upon the discovery of this bias, the Department of Energy (DOE) and BOEM funded NREL and PNNL to investigate the causes of, impacts of, and solutions to the bias in the CA20 data set. This report summarizes the findings of this research. We first investigated whether different WRF model setups could lead to reduced bias. We found that the choice of planetary boundary layer (PBL) scheme - which controls the vertical turbulent mixing of momentum, heat, and moisture in the lowermost part of the atmosphere - greatly affected hub-height wind speeds in the region. Specifically, switching from the Mellor-Yamada-Nakanishi-Niino (MYNN) scheme used in CA20 (and widely used across a range of operational and research weather models) to the less common Yonsei University (YSU) scheme nearly eliminated the bias at both the Humboldt and Morro Bay lidar locations. The large discrepancy between the MYNN- and YSU-modeled hub-height winds pointed towards the role of atmospheric stability. In general, PBL schemes agree well in conditions of high turbulence and mixing, normally referred to as "unstable" conditions. By contrast, PBL schemes start to diverge in "stable" conditions, where turbulence is low and thermal stratification (i.e., higher temperature air sitting on top of colder air) greatly suppresses vertical mixing. Under such conditions, winds aloft can decouple from surface effects and greatly accelerate, causing high wind speeds at hub-height and frequent low-level jets (LLJs). We determined that these stable conditions are in fact dominant in offshore California. The region is characterized by moderate-to-extreme stable stratification with a LLJ on average around 200 meters above sea-level. To our knowledge, no wind energy area globally has as strongly stable stratification as offshore California. Under these extreme conditions, we determined that the MYNN scheme models higher stability than YSU, resulting in less vertical turbulent mixing than YSU, allowing for the acceleration of hub-height winds, more intense LLJs, and higher-amplitude inertial oscillations. Using surface observations, we found that MYNN overestimates near-surface stability, whereas YSU tends to model stability better. We then considered several short-term case studies to assess additional meteorological drivers of the bias at Humboldt. We found that during synoptic scale northerly flows driven by the North Pacific High and inland thermal low, a coastal warm bias in the MYNN case studies contributes to the modeled wind speed bias by altering the boundary layer thermodynamics via a thermal wind mechanism. Given the strong performance of the YSU-based runs in offshore California, NREL has produced and published an updated version of the CA20 data set with YSU as the PBL scheme. This updated data set is now part of NREL's 2023 National Offshore Wind (NOW-23) data set, which covers all the U.S. offshore waters. The development and final validation of the NOW-23 data set in offshore California is documented in this report.

17 WIND ENERGY↗

Flammability and dispersion of tritium in confined release scenarios

Ignition of a flammable tritium-air mixture is the most probable means to produce the water form (T 2 O or HTO), which is more easily absorbed by living tissue and is hence ~10,000 times more hazardous to human health when uptake occurs compared to the gaseous form (T 2 or HT; per Mishima and Steele, 2002). Tritium-air mixtures with T 2 concentrations below 4 mol% are considered sub-flammable and will not readily convert to the more hazardous water form. It is therefore desirable from a safety perspective to understand the dispersion behavior of tritium under different release conditions, especially since tritium is often stored in quantities and pressures much lower than is typical for normal hydrogen. The formation of a flammable layer at the ceiling is a scenario of particular concern because the rate of dispersion to nonflammable conditions is slowest in this configuration, which maximizes the time window over which the flammable tritium may encounter an ignition source. This report describes the processes of buoyant rise and dispersion of tritium. Accumulation of flammable concentrations of tritium next to the ceiling is a common safety concern for hydrogen, but this situation can only occur if dispersion rates are slow with respect to rates of release and rise. Theory and simulations demonstrate that buoyancy does not cause regions with flammable concentrations to form within buildings from sources that have previously been mixed to sub-flammable concentrations. A simulated series of tritium release events with their associated dispersion behavior are reported herein; these simulations apply computational fluid dynamics to rooms with three different ceiling heights and a variety of tritium release rates. Safety related quantities from these simulations are reported, including the mass and volume of tritium occurring in a flammable mixture, the presence or absence of a flammable layer at the ceiling, and the time required for dispersion to nonflammable conditions after the end of the tritium release event. These safety metrics are influenced by the magnitude and rate of the tritium release with respect to the air volume in the room and also the momentum of the plume or jet with respect to the ceiling height. Several screening criteria are recommended to assess whether a specific tritium release scenario is likely to form a flammable layer at the ceiling. The methods and results in this modeling study have applicability to explosion safety analysis for other buoyant flammable gases, including the lighter isotopes of hydrogen.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

SINDA/FLUINT Stratified Tank Modeling for Cryrogenic Propellant Tanks

A general purpose SINDA/FLUINT (S/F) stratified tank model was created to simulate self-pressurization and axial jet TVS; Stratified layers in the vapor and liquid are modeled using S/F lumps.; The stratified tank model was constructed to permit incorporating the following additional features:, Multiple or singular lumps in the liquid and vapor regions of the tank, Real gases (also mixtures) and compressible liquids, Venting, pressurizing, and draining, Condensation and evaporation/boiling, Wall heat transfer, Elliptical, cylindrical, and spherical tank geometries; Extensive user logic is used to allow detailed tailoring - Don't have to rebuilt everything from scratch!!; Most code input for a specific case is done through the Registers Data Block:, Lump volumes are determined through user input:; Geometric tank dimensions (height, width, etc); Liquid level could be input as either a volume percentage of fill level or actual liquid level height

Axial Jet↗

Birth and growth of a granular jet

The interaction between fine grains and the surrounding interstitial gas in a granular bed can lead to qualitatively new phenomena not captured in a simple, single-fluid model of granular flows. This is demonstrated by the granular jet formed by the impact of a solid sphere into a bed of loose, fine sand. Unlike jets formed by impact in fluids, this jet is actually composed of two separate components, an initial thin jet formed by the collapse of the cavity left by the impacting object stacked on top of a second, thicker jet which depends strongly on the ambient gas pressure. This complex structure is the result of an interplay between ambient gas, bed particles, and impacting sphere. Here we present the results of systematic experiments that combine measurements of the jet above the surface varying the release height, sphere diameter, container size, and bed material with x-ray radiography below the surface to connect the changing response of the bed to the changing structure of the jet. We find that the interstitial gas trapped by the low permeability of a fine-grained bed plays two distinct roles in the formation of the jet. First, gas trapped and compressed between grains prevents compaction, causing the bed to flow like an incompressible fluid and allowing the impacting object to sink deep into the bed. Second, the jet is initiated by the gravity driven collapse of the cavity left by the impacting object. If the cavity is large enough, gas trapped and compressed by the collapsing cavity can amplify the jet by directly pushing bed material upwards and creating the thick jet. As a consequence of these two factors, when the ambient gas pressure is decreased, there is a crossover from a nearly incompressible, fluidlike response of the bed to a highly compressible, dissipative response. Compaction of the bed at reduced pressure reduces the final depth of the impacting object, resulting in a smaller cavity and in the demise of the thick jet.

42 ENGINEERING↗

Assessment of Differences in Phase 1 and Phase 2 Test Observations for Waste Treatment Plant Pulse Jet Mixer Tests with Non-Cohesive Solids

The purpose of this work was to assess the apparent discrepancy in critical suspension velocity (UCS) between M3 Phase 1 (Meyer et al. 2009) and Phase 2 testing conducted by Energy Solutions (ES) at Mid-Columbia Engineering (MCE) and to address the applicability of Phase 1 scale-up laws to Phase 2 test results. Three Phase 2 test sequences were analyzed in detail. Several sources of discrepancy were identified including differences in nominal versus actual velocity, definition of model input parameters, and definition of UCS. A remaining discrepancy was shown to not be solely an artifact of Phase 1 data correlations, but was fundamental to the tests. The non-prototypic aspects of Phase 1 testing were reviewed and assessed. The effects of non-prototypic refill associated with the closed loop operation of the jets, previously known to affect cloud height, can be described in terms of a modified settling velocity. When the modified settling velocity is incorporated into the Phase 1 “new” physical model the adjusted new physical model does a better job of predicting the Phase 2 test results. The adjusted new physical model was bench marked with data taken during three prototypic drive tests. Scale-up behavior of the Phase 1 tests was reviewed. The applicability of the Phase 1 scale-up behavior to Phase 2 prototypic testing was analyzed. The effects of non-prototypic refill caused measured values of UCS to be somewhat reduced at larger scales. Hence the scale-up exponents are believed to be smaller than they would have been had there been prototypic refill. Estimated scale-up exponents for the Phase 2 testing are 0.40 for 8-tube tests and 0.36 for 12-tube tests.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerodynamic levitation of laser-heated solids in gas jets

The aerodynamic levitation technique is developed for studies of high-temperature material properties and gas/condensed-phase reaction kinetics. Stable levitation is demonstrated in a supersonic jet from a 0.081 cm nozzle with 0.03-0.20 g 0.24-0.47 cm diameter solid spheres at a height between 0.7-2.0 cm above the nozzle and ambient pressures between 1.1-18 Torr. A model of supersonic jet levitation is developed which accurately predicts the values of height vs pressure over the full range of conditions investigated. It is found that the efficiency with which jet momentum is converted into levitation force decreases with the jet/specimen diameter ratio and the jet Reynolds number, and the rate of jet spreading with distance from the nozzle is found to agree with that measured by pitot tube traverses of the jet. In addition, laser heating is shown to reduce the jet momentum required for levitation at a given height and to increase levitation stability. Measurements of sphere levitation in subsonic gas jets show that the required jet momentum flow rate exceeds the specimen weight by about 2/the specimen drag coefficient at its terminal free-fall speed under ambient conditions.

Nordine, P. C.↗

Global distribution of total ozone derived from Nimbus 3 satellite during April July, 1969 and its implication to upper tropospheric circulation

Utilizing a stepwise multiple regression scheme, monthly mean global maps of total ozone are produced from the spectral intensity measurements made by the infrared interferometer spectrometer (IRIS) onboard the Nimbus 3 satellite for the period April 18 to July 22, 1969. These maps show that over the equatorial regions total ozone increases steadily from April to July. Further, latitudinal variation of total ozone derived from these maps shows that the ozone increases at all latitudes over the Southern Hemisphere uniformly from April to July while over the Northern Hemisphere the monthly decrease at all latitudes is nonuniform. In general, these maps bear a close resemblance to the upper tropospheric circulation. It is observed that the total ozone is best correlated with the 200 mb geopotential heights. This relationship enables the utilization of total ozone as a quasi-stream function to determine geostrophic winds at 200 mb level. Further, even at low latitudes where the total ozone does not bear simple relationship to the geopotential heights the course of the easterly jet stream with the help of the ozone measurements can be identified.

Prabhakara, C.↗

Numerical predictions of residence times behind a rearward facing step with transverse injection

A numerical investigation of the two-dimensional recirculation zone formed between a rear-ward facing step and a transverse hydrogen jet in a supersonic flow is presented. Calculations were made using an elliptic flow computer code with a time-relaxation finite difference integration algorithm. Cases were examined for jet static pressures between 2 and 5 times mainstream with jets located 3 to 7 step heights downstream of the step. Nominal mainstream flow conditions were Mach 2.4 air at 1 atm pressure and 1000K (1800R) static temperature. Results in the form of mean properties in the recirculation zone and residence time are presented. Calculations of the decay of hydrogen mass from the steady state are presented for selected cases. The combustion potential for each case is assessed by comparison of computed conditions in the recirculation zone with the results from a well-stirred reactor theory.

Rogers, R. C.↗

Numerical predictions of residence times behind a rearward facing step with transverse injection

A numerical investigation of the two-dimensional recirculation zone formed between a rearward facing step and a transverse hydrogen jet in a supersonic flow is presented. Calculations were made using an elliptic flow computer code with a time-relaxation finite difference integration algorithm. Cases were examined for jet static pressures between 2 and 5 times mainstream with jets located 3 to 7 step heights downstream of the step. Nominal mainstream flow conditions were Mach 2.4 air at 1 atm pressure and 1000 K (1800 R) static temperature. Results in the form of mean properties in the recirculation zone and residence time are presented. Calculations of the decay of hydrogen mass from the steady state are presented for selected cases. The combustion potential for each case is assessed by comparison of computed conditions in the recirculation zone with the results from a well-stirred reactor theory.

Rogers, R. C.↗

Characteristics of Non-Premixed Turbulent Flames in Microgravity

The momentum of the fuel (and/or air) jet is important in classifying gas-jet diffusion flame behavior. Normal-gravity data on gas-jet flames show that the flame height (non-dimensionalized with respect to an effective diameter) can be correlated to a density weighted Froude number in the buoyancy-dominated limit. In the momentum-dominated limit this non-dimensional flame height asymptotes to a constant value. The momentum-dominated limit under normal gravity conditions is usually obtained for very high injection velocities which in turn results in high values of the injection Reynolds number. This results in a complicated flame structure because of the large number of turbulence scales involved. In order to gain better insight into the structure of these flames it would be useful to reduce the injection Reynolds number while still maintaining turbulent conditions. This can be done in microgravity where momentum-dominated turbulent flames are obtained at much smaller velocities than in normal gravity. In this paper, experimental results on the effects of nozzle diameter and fuel dilution on flame height are discussed. The experimental values are compared with predictions from a numerical procedure utilizing the standard k-epsilon turbulence model. Flame height scaling with nozzle size and dilution is established. Differences between model predictions and measurements are presented. In order to explain these differences, evolutions of turbulent spectra and Taylor microscale along the flame axis are considered.

Hegde, U.↗

A Variable Resolution Stretched Grid General Circulation Model: Regional Climate Simulation

The development of and results obtained with a variable resolution stretched-grid GCM for the regional climate simulation mode, are presented. A global variable resolution stretched- grid used in the study has enhanced horizontal resolution over the U.S. as the area of interest The stretched-grid approach is an ideal tool for representing regional to global scale interaction& It is an alternative to the widely used nested grid approach introduced over a decade ago as a pioneering step in regional climate modeling. The major results of the study are presented for the successful stretched-grid GCM simulation of the anomalous climate event of the 1988 U.S. summer drought- The straightforward (with no updates) two month simulation is performed with 60 km regional resolution- The major drought fields, patterns and characteristics such as the time averaged 500 hPa heights precipitation and the low level jet over the drought area. appear to be close to the verifying analyses for the stretched-grid simulation- In other words, the stretched-grid GCM provides an efficient down-scaling over the area of interest with enhanced horizontal resolution. It is also shown that the GCM skill is sustained throughout the simulation extended to one year. The developed and tested in a simulation mode stretched-grid GCM is a viable tool for regional and subregional climate studies and applications.

Fox-Rabinovitz, Michael S.↗

Experimental Investigation of Normal Shock Boundary-Layer Interaction with Hybrid Flow Control

Hybrid flow control, a combination of micro-ramps and micro-jets, was experimentally investigated in the 15x15 cm Supersonic Wind Tunnel (SWT) at the NASA Glenn Research Center. Full factorial, a design of experiments (DOE) method, was used to develop a test matrix with variables such as inter-ramp spacing, ramp height and chord length, and micro-jet injection flow ratio. A total of 17 configurations were tested with various parameters to meet the DOE criteria. In addition to boundary-layer measurements, oil flow visualization was used to qualitatively understand shock induced flow separation characteristics. The flow visualization showed the normal shock location, size of the separation, path of the downstream moving counter-rotating vortices, and corner flow effects. The results show that hybrid flow control demonstrates promise in reducing the size of shock boundary-layer interactions and resulting flow separation by means of energizing the boundary layer.

Vyas, Manan A.↗

Simulations suggest offshore wind farms modify low-level jets

Abstract. Offshore wind farms are scheduled to be constructed along the East Coast of the US in the coming years. Low-level jets (LLJs) – layers of relatively fast winds at low altitudes – also occur frequently in this region. Because LLJs provide considerable wind resources, it is important to understand how LLJs might change with turbine construction. LLJs also influence moisture and pollution transport; thus, the effects of wind farms on LLJs could also affect the region’s meteorology. In the absence of observations or significant wind farm construction as yet, we compare 1 year of simulations from the Weather Research and Forecasting (WRF) model with and without wind farms incorporated, focusing on locations chosen by their proximity to future wind development areas. We develop and present an algorithm to detect LLJs at each hour of the year at each of these locations. We validate the algorithm to the extent possible by comparing LLJs identified by lidar, constrained to the lowest 200 m, to WRF simulations of these very low LLJs (vLLJs). In the NOW-WAKES simulation data set, we find offshore LLJs in this region occur about 25 % of the time, most frequently at night, in the spring and summer months, in stably stratified conditions, and when a southwesterly wind is blowing. LLJ wind speed maxima range from 10 m s−1 to over 40 m s−1. The altitude of maximum wind speed, or the jet “nose”, is typically 300 m above the surface, above the height of most profiling lidars, although several hours of vLLJs occur in each month in the data set. The diurnal cycle for vLLJs is less pronounced than for all LLJs. Wind farms erode LLJs, as LLJs occur less frequently (19 %–20 % of hours) in the wind farm simulations than in the no-wind-farm (NWF) simulation (25 % of hours). When LLJs do occur in the simulation with wind farms, their noses are higher than in the NWF simulation: the LLJ nose has a mean altitude near 300 m for the NWF jets, but that nose height moves higher in the presence of wind farms, to a mean altitude near 400 m. Rotor region (30–250 m) wind veer is reduced across almost all months of the year in the wind farm simulations, while rotor region wind shear is similar in both simulations.

17 WIND ENERGY↗