Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Neutron generator based on intense lithium beam driver

We are proposing a compact neutron generator based on a Li beam driver. The proposed neutron generator comprises a laser ion source, a radio-frequency quadrupole linear accelerator (RFQ linac), a drift tube linac, and a target containing protons. In the generator, the lithium ion is used as a projectile instead of protons to utilize the kinematic focusing technique. The technique enables us to enhance the neutron flux without increasing the beam energy, which is important to develop a clean compact neutron generator. Moreover, the combination of a laser ion source and a RFQ linac with the direct plasma injection scheme will provide several tens of mA of a fully ionized lithium beam, which is much higher than that of conventional heavy ion sources comparable with proton drivers. Neutrons are generated by the nuclear reaction of the lithium ions and protons in the beam target. In this paper, we reported the current status of the development. For RFQ, we designed the RFQ rods to accelerate 40 mA of 7Li3+. We fabricated and installed the rods into a cavity, and, as a first test, accelerated 10 mA of C6+ successfully.

Ikeda, Shunsuke (ORCID:0000000339800577)↗

Study on ion current density of different species in laser produced plasma in a solenoid magnet

A solenoid magnetic field along the expanding laser-produced plasma is an essential technique of the laser ion source. The solenoid field can increase ion beam current at beam extraction point by a factor of 2 to over 100 by confining moving laser produced plasma in transverse direction. This technique is used everywhere from development lab to operational machine for user operation. However, the motion of ions in laser produced plasma is not fully understood. In this study, we experimentally investigated the motion of ions in a solenoid magnet (inner diameter 102 mm, coil length 1980 mm) for Al, Fe, and Ta targets. Using the following three conditions: full solenoid bore, a φ51 mm collimator on the solenoid axis, and a thin-wall φ51 mm tube at the bottom of the solenoid, we found that extracting ions at off-axis position (20~30 mm from the solenoid axis in this study) can enhance ion intensity by a factor of three or more. We continue to investigate ion motion in a solenoid field to develop better laser ion source design.

43 PARTICLE ACCELERATORS↗

Status of CHIP-TRAP: The Central Michigan University High-Precision Penning Trap

Precise and accurate atomic mass data provide crucial information for applications in a wide range of fields in physics and beyond, including astrophysics, nuclear structure, particle and neutrino physics, fundamental symmetries, chemistry, and metrology. The most precise atomic mass measurements are performed on charged particles confined in a Penning trap. Here, we describe the development, status, and outlook of CHIP-TRAP: the Central Michigan University high-precision Penning trap. CHIP-TRAP aims to perform ultra-high precision (~1 part in 10 11 fractional precision) mass measurements on stable and long-lived isotopes produced with external ion sources and transported to the Penning traps. Along the way, ions of a particular m/q are selected with a multi-reflection time-of-flight mass separator (MR-TOF-MS), with further filtering performed in a cylindrical capture trap before the ions are transported to a pair of hyperbolic measurement traps. In this paper, we report on the design and status of CHIP-TRAP and present results from the commissioning of the ion sources, MR-TOF-MS, and capture trap. We also provide an outlook on the continued development and commissioning of CHIP-TRAP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Salt Effects on Li-Ion Exchange Kinetics of Na 2 Mg 2 P 3 O 9 N: Systematic In Situ Synchrotron Diffraction Studies

The kinetics and thermodynamics of solid-state ion exchange of Li+ into Na2Mg2P3O9N were investigated using in situ synchrotron X-ray diffraction methods for a series of Li-containing salts, allowing systematic trends with general applicability to ion exchange reactions to be elucidated. The collection of data for a wide range of reaction conditions was enabled through the use of a novel multiwell sample environment which leverages the ability of the synchrotron beamline to rapidly (similar to 1 s) collect high-quality data suitable for monitoring reaction progress. From these data, it was possible to resolve the influence of salt choice and salt concentration on the ion exchange reaction kinetics. Furthermore, by carrying out experiments at different temperatures, initial estimates of activation energies were obtained. It was generally found that the ion exchange reaction kinetics strongly depended on the salt chosen as the ion source rather than being primarily determined by the ion mobility of the ceramic.

Cosby, Monty R.↗

High Brightness High Duty Factor Negative Ion Beam Injector [Slides]

The high brightness negative ion injector combines multiple individual low-duty-factor H- ion sources (multiplexing) in a manner that allows flexibility in final pulse format and beam duty factor up to CW and increases reliability by eliminating an otherwise single-point failure usually associated with using a single ion source. The multiplexing of multiple beams in new injector system also preserves the beam quality of each individual ion source, eliminating a significant source of beam quality degradation usually associated with combining beams.

43 PARTICLE ACCELERATORS↗

Diagnostics for multiple frequency heating and investigation of underlying processes

The development of new facilities routinely challenges ion source designers to build and operate sources that can achieve ever higher beam intensities and energies. As shown in this work, electron cyclotron resonance ion sources have proven to be extremely capable in meeting these challenges through the production of intense beams of medium and high-charge state ions. As performance boundaries are pushed, source stability becomes an issue as does the technology required to meet the challenge. Multiple frequency heating, the simultaneous use of two or more plasma heating frequencies, is a powerful tool in meeting the simultaneous need of intensity and stability. Relatively straightforward to utilize, the technique has been employed at numerous facilities to increase beam current and achievable charge state while also stabilizing the plasma. Its application has expanded the operational boundaries of existing and next generation sources, demonstrating that these devices have not yet achieved their full operational potential. To better understand the underlying physics, the diagnostics used to probe the source operational boundaries and the plasma properties have become increasingly sophisticated. In concert with detailed modeling, they are beginning to provide insight into the heating mechanism and, with that, the prospect of future advances.

47 OTHER INSTRUMENTATION↗

Results of Speciation Determination Measurements of Insulating Sulfur Hexafluoride Gas

Under the direction of the NNSA NA-231 Mo-99 Program, SRNL has provided technical assistance to U.S. companies under cooperative agreements. One such area of technical assistance has been for the recommendation for contamination management methods in the eventuality that tritium contaminates the insulating gas of a high-voltage ion source used in the accelerator-based process developed by SHINE Medical Technologies to produce Mo-99. The SHINE accelerator process uses tritium as the target of a deuterium ion beam, where the ion beam is produced within a high-voltage ion source insulated with sulfur hexafluoride (SF 6 ), and is separated from the tritium target by an extensive pump train. Normal operating conditions preclude the conditions necessary for contamination of the insulating gas, however certain atypical conditions could result in a tritium contamination event. Accelerator based processes for medical isotope production represent an anomalous tritium contamination challenge due to the presence of SF 6 . SF 6 decomposes through normal use as an insulator gas, and the exact speciation of the decomposition byproducts depends on a variety of factors. This creates a scenario where the anticipation of species present in the insulating gas mixture is difficult. In turn, the fate of tritium within such a chemical system is unclear. This document discusses the results of measurements made in-situ of the SF 6 insulating gas in use within a SHINE Medical Technology’s high-voltage ion source. This was done in an effort to determine the chemical speciation of the gas, allowing for the recommendation of management strategies in the event that tritium contaminates the insulating gas. The results of the measurements reported in this work suggest that tritium contamination in the insulating gas may result in two chemical forms of tritium in the system, tritiated water and molecular tritium. These two forms of tritium would be captured by two methods. Tritiated water may be captured and removed from the SF 6 by an adsorbent canister already present within the pressure vessel that houses the insulating gas while in use. It may also be separated from the SF 6 during routine purification of the SF 6 , which is performed by SHINE personnel routinely. The purification cart will perform all non-embedded systems cleanup necessary to remediate tritiated species in the system. The purification cart passes the insulating gas through several filters, followed by the liquefication of the SF 6 . The filters will separate tritiated water from the SF 6 at this stage. It is expected that molecular tritium will accumulate in the gas-phase during the liquification step, which is separated and stored. Tritium may be recovered from this mixture through more conventional hydrogen purification methods such as a palladium diffuser.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Charge breeders: Development of diagnostic tools to probe the underlying physics

Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron-ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.

47 OTHER INSTRUMENTATION↗

Electromagnetic Radioisotope Separator for Methods Development, Testing, and Training

The major goal of the project is the construction and operation of an electromagnetic isotope separator. Included in that goal is the construction and installation of a high throughput surface ion source, with specific applicability to the Lanthanides. The surface ion source features a single-piece titanium crucible insert that mates with a tantalum hot surface ionizer. The titanium crucible, which does not readily activate, can be loaded with samarium and then irradiated simultaneously, greatly reducing operator dose.

07 ISOTOPE AND RADIATION SOURCES↗

Impurity transport in PISCES-RF

Linear plasma devices (LPD) utilizing a helicon plasma source, a high density light ion source, can generate impurities due to progressive erosion of the radio frequency (RF) transmission window caused by rectified sheath voltage. These source-born impurities can entrain and be transported by the plasma toward a target, affecting plasma-material interaction studies. Earlier work on material testing in Prototype-Materials Plasma Exposure eXperiment at ORNL revealed significant source impurity deposition on downstream targets. However, using a similar RF source, no target impurity deposition is observed in Plasma Interaction Surface Component Experimental Station (PISCES)-RF despite evidence of RF window erosion in the source region, thereby motivating the present work. Experimentally, using various magnetic field configurations upstream of the PISCES-RF plasma source and seeding titanium (Ti) impurities at various axial locations, impurity transport and deposition along the machine axis were investigated. It was found that Ti deposition was localized to the side of the plasma source where the Ti impurity was seeded. In contrast, aluminum (Al) deposition, originating from the sputtering of the helicon window, occurred predominantly upstream of the plasma source, suggesting an asymmetry in the axial transport of eroded RF window material. These observations suggest a stagnation of the parallel plasma flow immediately downstream of the plasma source, with impurity ions remaining unmagnetized near the source upstream. Al deposition in magnetic field-free regions in PISCES-RF indicates that sputtered Al impurities likely remained neutral due to their large ionization mean-free path under PISCES-RF conditions. Plasma modeling and simulation supported this, indicating that Al-neutrals transport toward the helicon source upstream for low electron density cases. It was found that the Larmor radius of the Al ions was greater than the plasma radius towards the source upstream and remained weakly magnetized in PISCES-RF, meaning that plasma source-born impurities are not efficiently entrained in the plasma flow. These findings provide critical insights into impurity transport in helicon plasma-based LPDs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing the DIII-D co/counter off-axis neutral beam injected power and ability to balance injected torque

DIII-D has undergone a major upgrade and successfully injected high power off-axis neutral beams (~4 MW) in both co-current and counter-current directions. This capability of high power co/counter steerable off-axis neutral beams on a major tokamak opens a unique parameter space of broad pressure and current profiles for high beta steady-state advanced tokamak (AT) scenarios, while retaining the ability to balance the injected torque for low rotation studies. This co/counter off-axis neutral beam capability is being used to validate physics-based energetic particle and thermal transport models for designing next-step facilities based on the steady-state AT approach. This paper reports on the critical evaluation of the transmitted power and energetic ion population produced by this heating and current drive system, which is assessed through visible imaging, neutron measurements and rotation profile measurements at balanced torque. Minimal losses of neutral beam power have been achieved by optimizing the strongly focused ion sources required to pass through the aperture. Tilting of the ion source has been guided by fast visible imaging and resulted in neutral beam injection along the design centerline with empirical characterization of each beam's divergence derived from the imaging data and used in the NUBEAM description of the beam injection. Through exclusive power injection of each neutral beam into MHD quiescent plasmas across a range of neutral beam voltage, perveance and plasma current we conclude that a modest reduction (~10%–15%) of transmitted power compared to on-axis, standard focus has been incurred. We report corrections that more accurately represent the injected power. Good ability to balance the neutral beam torque has been demonstrated by injecting the new off-axis counter injecting beam against the existing off-axis co-injected beam in 2.0 T, 1.0 MA, MHD quiescent L-mode plasmas. Furthermore, the torque balance studies verify the ability to operate with balanced injection, which is critical for achieving low torque and low rotation operation for physics studies and in ITER demonstration discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Growth of Highly Transparent Amorphous Carbon Films Using Beam Plasma Source

A single beam plasma source was used to deposit hydrogenated amorphous carbon (a-C:H) coatings at room temperature. Using methane source gas, a-C:H coatings were deposited at different radio frequency (RF) power to fabricate transparent and durable coatings. The film deposition rate was almost linearly proportional to the ion source power. Hydrogenated amorphous carbon films of ~100 nm thickness appeared to be highly transparent from UV to the infrared range with a transmittance of ~90% and optical bandgap of ~3.7 eV. The coatings also possess desirable mechanical properties with Young’s modulus of ~78 GPa and density of ~1.9 g/cm3. The combined material properties of high transmittance and high durability make the ion-source-deposited a-C:H coatings attractive for many applications.

36 MATERIALS SCIENCE↗

High-Resolution Laser Spectroscopy on the Hyperfine Structure of 255Fm (𝑍=100)

We report on high-resolution laser spectroscopy of 255Fm (𝑇1/2=20 h), one of the heaviest nuclides available from reactor breeding. The hyperfine structures in two different atomic ground-state transitions at 398.4 nm and 398.2 nm were probed by in-source laser spectroscopy at the RISIKO mass separator in Mainz, using the perpendicularly illuminated laser ion source and trap (PI-LIST) high-resolution ion source. Experimental results were combined with hyperfine fields from various atomic ab initio calculations, in particular using multiconfiguration Dirac-Hartree-Fock theory, as implemented in grasp18. In this manner, the nuclear magnetic dipole and electric quadrupole moments were derived to be 𝜇=−0.75⁢(5) 𝜇N and 𝑄s=+5.84⁢(13) eb, respectively. The magnetic moment indicates occupation of the 𝜈⁢7/2⁢[613] Nilsson orbital, while the large quadrupole moment confirms strong, stable prolate deformation consistent with systematics in the heavy actinides. Comparisons with available expectation values from nuclear theory show good agreement, providing a stringent benchmark for the used theoretical models. These results revise earlier data and establish 255Fm as a reference isotope for future high-resolution studies.

Ezold, Julie [ORNL] (ORCID:0000000250550022)↗

Gas Stopper Developments for Improved Purity and Intensity of Low-Energy, Rare Isotope Ion Beams (Final Technical Report)

This final technical report summarizes the work of the Michigan State University (MSU) team supported by grant # DE-SC0021423 awarded by the Office of Nuclear Physics, Department of Energy. Objectives: The successful fulfillment of the FRIB science mission hinges on ensuring the availability of fast, stopped, and reaccelerated beams consisting of rare isotopes. This project's research and development focus was dedicated to supporting the advancement and creation of a cutting-edge linear gas stopper. The primary aim is to efficiently convert the high-intensity fast beams of rare isotopes provided by FRIB into high-quality, low-energy beams. These beams are essential for conducting stopped beam experiments or for subsequent reacceleration. The overarching goal is to advance technology, aiming to increase the beam rate capability of the linear gas stopper for medium-to-heavy-mass rare isotopes by more than tenfold compared to the currently most effective gas stopper in operation, and to improve the purity of the delivered beams. Project Description: The existing technology employed in gas stopping devices designed for low-energy, rare-isotope beams presents limitations in both the purity of extracted beams and the intensities of injected beams. These limitations are incompatible with the requirements of the recently commissioned rare isotope beam facility, FRIB. Our research and development efforts, aligned with the previously outlined objectives, focused on addressing the most critical aspects for enhancing beam-rate capability and purity. Specifically, advanced particle-in-cell simulations were developed and integrated into a simulation pipeline to explore the efficacy of multi-layer RF carpets on increasing ion transport efficiency with high incoming beam rates that generate space charge fields which can limit it. We also explored the possibility of using a collision-induced-dissociation (CID) gas cell to break up molecular contaminant ions that are generated during the stopping process. A prototype CID gas cell was constructed and tested with beams from an offline ion source, validating the concept with the successful demonstration of breaking of molecular ions. The outcome of this research enabled the formulation a conceptual design for a next-generation linear gas stopping device specifically tailored for FRIB. This device is envisioned to deliver rare-isotope-ion beams at a rate of 10 8 particles per second or higher, accompanied by advancements in purity. Methods employed: This project leverages advancements in technologies initially designed for the Advanced Cryogenic Gas Stopper (ACGS), the current state-of-the-art linear gas stopper, through the use of new simulations and beam purification via collision-induced-dissociation. The methods include: 1. Development of a prototype low-energy, low-pressure CID gas stopper. This prototype features a thin, approximately 20 nm, Si 3 N 4 entrance window designed for dissociating stable and rare-isotope molecular ions. The goal is to enhance beam purification and overall efficiency. 2. Creation of Particle-in-cell (PIC) simulations to assess the advantages of multi-layer RF carpets and multi-point extraction for ion transport efficiency. These simulations rely on the 3DCylPIC package, specifically designed for studying devices of this nature. The goal is to quantify and mitigate ion transport losses due to space charge generated in the stopping process of large numbers of ions. 3. Perform ion transport simulations across an RF carpet using an 8-phase travelling wave and evaluate its performance. Compared to the 4-phase RF carpets used in ACGS, the 8-phase carpets will double the wavelength of the generated traveling wave allowing for larger maximum RF amplitudes that could result in improved ion transport efficiency for high-intensity incoming beams when large space charge fields are present. Impact: Tackling the primary challenges associated with transforming high-energy projectile fragment beams into low-energy beams—specifically, addressing efficiency and purity—holds significant promise for advancing FRIB science. This advancement will particularly impact precision mass measurements, laser spectroscopy of short-lived nuclei, and studies in astrophysics and nuclear reactions using reaccelerated beams. These domains play a crucial role in addressing key questions outlined in the 2023 NSAC long-range plan, spanning nuclear structure, nuclear astrophysics, and fundamental symmetries. Additionally, they contribute to addressing 10 out of the 17 benchmarks identified by the NRC RISAC. The development of a next-generation gas stopping device capable of delivering low-energy, rare-isotope beams at a rate of 10 8 particles per second, or more, with high purity holds the potential to unlock experiments that would otherwise be unfeasible. Furthermore, it is expected to reduce the time required for experiments at FRIB, thereby maximizing scientific output. The research and development activities performed as part of this project bolstered essential competencies at FRIB in beam physics and ion source technologies, provided valuable training opportunities for junior scientists.

43 PARTICLE ACCELERATORS↗

Record of Decision: LEBT Energy Change

The LAMP Conceptual Design (LCD), as described in the LAMP Conceptual Design Report incorporates multiple 100-keV low-energy beam transport (LEBT) lines between the ion sources and the radiofrequency quadrupole (RFQ). The LEBT lines transport H + and H - beams from their respective ion sources to the RFQ entrance, and provide the required manipulations (focusing, steering, chopping, etc.) to the ion beams to prepare them for injection into the RFQ and further acceleration.

43 PARTICLE ACCELERATORS↗

Generation of focusing ion beams by magnetized electron sheath acceleration

Abstract We present the first 3D fully kinetic simulations of laser driven sheath-based ion acceleration with a kilotesla-level applied magnetic field. The application of a strong magnetic field significantly and beneficially alters sheath based ion acceleration and creates two distinct stages in the acceleration process associated with the time-evolving magnetization of the hot electron sheath. The first stage delivers dramatically enhanced acceleration, and the second reverses the typical outward-directed topology of the sheath electric field into a focusing configuration. The net result is a focusing, magnetic field-directed ion source of multiple species with strongly enhanced energy and number. The predicted improvements in ion source characteristics are desirable for applications and suggest a route to experimentally confirm magnetization-related effects in the high energy density regime. We additionally perform a comparison between 2D and 3D simulation geometry, on which basis we predict the feasibility of observing magnetic field effects under experimentally relevant conditions.

42 ENGINEERING↗

Simulation study of ion beam used to produce Mo-99

An 820 mA CW positive ion source is being developed to produce Mo-99 using the fusion of deuterium and tritium ion beams on a rotating target to produce neutrons for use in the production of radiopharmaceuticals. The ion source consists of an RF plasma source, a multi-aperture extractor, and 300 kV accelerating column. This paper will describe a simulation study of the beam through the extractor grid and the accelerator to the target. The uniformity of beam distribution on the target is an important aspect of the simulation.

43 PARTICLE ACCELERATORS↗

The ion-gas-neutral interactions with surfaces-2 (IGNIS-2) facility for the study of plasma–material interactions

The Ion-Gas-Neutral Interactions with Surfaces-2 (IGNIS-2) surface science facility has been designed at the Pennsylvania State University with the specific purpose of enabling experiments to study plasma–material interactions. This in situ surface modification and characterization facility consists of multiple reconfigurable substations that are connected through a central transfer chamber. This fully connected vacuum system ensures that the physical and chemical properties of samples are not altered between surface modification and analysis. The modification techniques in IGNIS-2 include a low-energy (<300 eV), high-flux (up to 1016 cm−2 s−1) broad-beam ion source, a liquid metal dropper, a lithium injection system, an RF sputter source, and an evaporator. Its characterization techniques include charged particle-based techniques, such as low-energy ion scattering (enabled by two <5 keV ion sources) and x-ray photoelectron spectroscopy, and photon and light-based techniques, such as x-ray fluorescence, multi-beam optical stress sensors, and optical cameras. All of these techniques can be utilized up to mTorr pressures, allowing both in situ and in operando studies to be conducted. Results are presented on lithium wetting experiments of argon-irradiated tungsten-based composites, surface stress measurements of tungsten films during deuterium ion irradiation, and temperature-programmed desorption of deuterium-irradiated graphite to demonstrate the in situ capabilities of this new facility.

Instruments & Instrumentation↗