Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion mobility spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Identification of Unique Fragmentation Patterns of Fentanyl Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

The opioid crisis in the United States is being fueled by the rapid emergence of new fentanyl analogs and precursors that can elude traditional library-based screening methods, which require data from known reference compounds. Since reference compounds are unavailable for new fentanyl analogs, we examined if fentanyls (fentanyl + fentanyl analogs) could be identified in a reference-free manner using a combination of electrospray ionization (ESI), high-resolution ion mobility (IM) spectrometry, high-resolution mass spectrometry (MS), and higher-energy collision-induced dissociation (MS/MS). We analyzed a mixture containing nine fentanyls and W-15 (a structurally similar molecule) and found that the protonated forms of all fentanyls uniquely exhibited two baseline separated IM distributions that produced different MS/MS patterns. Upon fragmentation, both IM distributions of all fentanyls produced two high intensity fragments resulting from amine site cleavages. The higher mobility distributions of all fentanyls also produced several low intensity fragments, but surprisingly, these same fragments exhibited much greater intensities in the lower mobility distributions. This observation demonstrates that many fragments of fentanyls predominantly originate from one of two different gas-phase structures (suggestive of protomers). Furthermore, increasing the water concentration in the ESI solution increased the intensity of the lower mobility distribution relative to the higher mobility distribution, which further supports that fentanyls exist as two gas-phase protomers. In conclusion, our new observations on the IM and MS/MS properties of fentanyls can be exploited to positively identify them as fentanyls without requiring reference libraries and will hopefully assist first responders and law enforcement in combating new and emerging fentanyls.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mass spectrometry structural analysis of intrinsically disordered phosphoproteins

Phosphorylation is a ubiquitous protein modification that is known to play important roles in many biological phenomena including cell signaling, the opening and closing of membrane protein channels, and even triggering of amyloid protein aggregation. Despite the effects phosphorylation has on protein function, the impact phosphorylation has on the structure of proteins is not well understood. Here, to determine how phosphorylation affects the structure of proteins, top-down mass spectrometry (TD-MS) and ion mobility-mass spectrometry (IM-MS) were performed on various phosphorylated proteins and their dephosphorylated proteoforms. TD-MS with collision- and electron-based fragmentation techniques was utilized to locate phosphorylation sites on the intrinsically disordered amyloid proteins β-casein and α-synuclein. TD-MS also provided evidence that alkaline phosphatase dephosphorylates β-casein from the N-terminus to the C-terminus. Furthermore, IM-MS of common phosphorylated proteins such as β-casein, α-casein, ovalbumin, and phosvitin indicates that phosphorylation promotes compaction of protein structure in denaturing as well as native conditions. Increases in abundance of more compact conformers are also observed when the disease related amyloid protein α-synuclein is phosphorylated at serine 129. We interpret the increased abundance of more compact conformers when proteins are phosphorylated as evidence that salt bridges form between negatively charged phosphates and positively charged residues, which alters protein structure. Salt bridge formation due to phosphorylation could be a mechanism for regulating protein function and be responsible for many of the phenomena observed in nature.

Amyloid proteins↗

Separation of isobaric Amino Acids and Small Molecule Metabolites Using Multipass Ion Mobility Analysis

Amino acids along with small molecule metabolites are important biomarkers for the study and detection of diseases that are initially analyzed in untargeted omics fashion. Amino acids and many metabolites are isomeric, and their specific form can have a significant impact on biological function. Chromatographic separation of isomers is challenging, and they cannot be resolved by mass spectrometry alone. Ion mobility is a technique that allows the separation of ions based on their size, shape, and charge. Here we present the results of the separation of isobaric amino acids and small molecule metabolites using a system that allows for multi-pass ion mobility separation which, in turn, enhances the ion mobility resolution of the separation. Amino acid standards and small molecule metabolites commercially available were infused directly into a SELECT SERIES™ Cyclic™ IMS system. Solutions of individual and mixture of the isobaric species were used and the mobility conditions were optimized for multiple passes for each corresponding set of isobaric species. Both ionization polarities and various solvent adducts were tested to provide the best signal intensity and separation. Amino acids such as leucine and isoleucine have previously been separated with ion mobility in a system with lower ion mobility resolution (SYNAPT™ G2 mass spectrometer) rendering about 90% of valley and mobility resolution of around 40 Ω/ΔΩ. With the enhanced ion mobility resolution using the cyclic IMS technique we have obtained almost complete separation of those amino acids rendering a valley of about 10% after 15 passes. For this case, the mobility resolution is around 250 Ω/ΔΩ. Another example is the separation of glucose-6-phosphate from glucose-1-phosphate, and fructose-6phosphate which were separated after 10 passes. For this case, the mobility resolution is around 205 Ω/ΔΩ.

Hernando J Olivos↗

Exploring new frontiers in type 1 diabetes through advanced mass-spectrometry-based molecular measurements

Type 1 diabetes (T1D) is a devastating autoimmune disease for which advanced mass spectrometry (MS) methods are increasingly used to identify new biomarkers and better understand underlying mechanisms. For example, integration of MS analysis and machine learning has identified multimolecular biomarker panels. In mechanistic studies, MS has contributed to the discovery of neoepitopes, and pathways involved in disease development and identifying therapeutic targets. However, challenges remain in understanding the role of tissue microenvironments, spatial heterogeneity, and environmental factors in disease pathogenesis. Recent advancements in MS, such as ultra-fast ion-mobility separations, and single-cell and spatial omics, can play a central role in addressing these challenges. Here, in this work, we review recent advancements in MS-based molecular measurements and their role in understanding T1D.

60 APPLIED LIFE SCIENCES↗

Introducing Molecular Hypernetworks for Discovery in Multidimensional Metabolomics Data

Orthogonal separations of data from high-resolution mass spectrometry can provide insight into sample composition and address challenges of complete annotation of molecules in untargeted metabolomics. “Molecular networks” (MNs), as used in the Global Natural Products Social Molecular Networking platform, are a prominent strategy for exploring and visualizing molecular relationships and improving annotation. MNs are mathematical graphs showing the relationships between measured multidimensional data features. MNs also show promise for using network science algorithms to automatically identify targets for annotation candidates and to dereplicate features associated with a single molecular identity. Here, this paper introduces “molecular hypernetworks” (MHNs) as more complex MN models able to natively represent multiway relationships among observations. Compared to MNs, MHNs can more parsimoniously represent the inherent complexity present among groups of observations, initially supporting improved exploratory data analysis and visualization. MHNs also promise to increase confidence in annotation propagation, for both human and analytical processing. We first illustrate MHNs with simple examples, and build them from liquid chromatography- and ion mobility spectrometry-separated MS data. We then describe a method to construct MHNs directly from existing MNs as their “clique reconstructions”, demonstrating their utility by comparing examples of previously published graph-based MNs to their respective MHNs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MZA: A Data Conversion Tool to Facilitate Software Development and Artificial Intelligence Research in Multidimensional Mass Spectrometry

Modern mass spectrometry-based workflows employing hybrid instrumentation and orthogonal separations collect multidimensional data, potentially allowing deeper understanding in omics studies through adoption of artificial intelligence methods. However, the large volume of these rich data challenges existing data storage and access technologies, therefore precluding informatics advancements. Here we present MZA™ (pronounced m-za), the mass-to-charge (m/z) generic data storage and access tool designed to facilitate software development and artificial intelligence research in multidimensional mass spectrometry measurements. Composed by a data conversion tool and a simple file structure based on the HDF5 format, MZA provides easy, cross-platform and efficient programmatic access to raw MS-data, enabling fast development of new tools in data science programming languages such as Python and R. The software executable and example Python and R scripts are freely available at https://github.com/PNNL-m-q/mza.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Critical amino acid residues in the N-terminal domain of NADPH-dependent assimilatory sulfite reductase flavoprotein mediate octameric assembly

How large, flexible enzymes assemble into defined oligomeric architectures remains a central question in biology. NADPH-dependent assimilatory sulfite reductase (SiR) forms a heterododecamer built on an octameric flavoprotein (SiRFP) core, yet the molecular basis for this assembly has been unresolved because of its disordered N-terminus. Here, we use ion mobility mass spectrometry, small-angle neutron scattering, and mutagenesis to define the mechanism of SiRFP oligomerization. We show that SiRFP forms a discrete, stable octamer in solution. We also report that its N-terminal 52-residue segment is necessary and sufficient to mediate assembly, also mediating oligomerization when fused to a heterologous protein. Structure-guided mutagenesis identifies four residues (Gln22, Tyr39, Phe40, and Gln47) whose substitution disrupts the octamer, producing concentration-dependent lower-order species while retaining catalytic activity. These findings define the determinants of SiRFP assembly with broader implications for engineering homomeric protein complexes.

Nagy, Gergely [ORNL] (ORCID:0000000327420198)↗

Proteomic assessment of serum biomarkers of longevity in older men

The biological bases of longevity are not well understood, and there are limited biomarkers for the prediction of long life. We used a high-throughput, discovery-based proteomics approach to identify serum peptides and proteins that were associated with the attainment of longevity in a longitudinal study of community-dwelling men age ≥65 years. Baseline serum in 1196 men were analyzed using liquid chromatography–ion mobility–mass spectrometry, and lifespan was determined during ~12 years of follow-up. Men who achieved longevity (≥90% expected survival) were compared to those who died earlier. Rigorous statistical methods that controlled for false positivity were utilized to identify 25 proteins that were associated with longevity. All these proteins were in lower abundance in long-lived men and included a variety involved in inflammation or complement activation. Lower levels of longevity-associated proteins were also associated with better health status, but as time to death shortened, levels of these proteins increased. Pathway analyses implicated a number of compounds as important upstream regulators of the proteins and implicated shared networks that underlie the observed associations with longevity. Overall, these results suggest that complex pathways, prominently including inflammation, are linked to the likelihood of attaining longevity. This work may serve to identify novel biomarkers for longevity and to understand the biology underlying lifespan.

60 APPLIED LIFE SCIENCES↗

Resolving Lipid Structures for Threat-Agnostic Signatures

Development of threat-agnostic biosignatures is critical for the detection of and response to biological threats that go beyond the historical list-based approach. Lipids are a class of structurally diverse biomolecules that hold great promise as relevant threat-agnostic biosignatures, yet the fundamental challenge of resolving and decoding structural differences among lipids remains an obstacle in the pursuit of signature development. Structural analysis of complex lipids remains stymied due to spectral complexity and the inability to resolve low abundance lipids. To address these challenges, we integrated ozonolysis with ion mobility mass spectrometry (IMS-MS) analysis to determine the structural information for complex lipid species and (2) reduced lipid sample complexity prior to introduction into the IMS-MS using normal phase high pressure liquid chromatography (HPLC) to enable the ozonolysis of low abundance lipids. We applied these new capabilities to define the lipid structures in antimicrobial resistant (AMR) and antimicrobial susceptible (AMS) biothreat organism Yersinia pestis and cells infected with Severe Acute Respiratory Syndrome coronavirus 2 (SARS-CoV-2) variants.

59 BASIC BIOLOGICAL SCIENCES↗

Ion Mobility Separations Using Cocentric Architecture

Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.

59 BASIC BIOLOGICAL SCIENCES↗

Discovery of a Ferromagnetic Nickel Chalcogenide Nanocluster Ni 3 S 3 H(PEt 3 ) 5

Atomically precise ligated nanoclusters (NC) are promising cluster-based materials with novel molecular architectures and tunable magnetic properties. Herein, the synthesis and characterization of a nickel sulfide NC Ni 3 S 3 H(PEt 3 ) 5 (PEt 3 = triethylphosphine) with distinct magnetic properties are reported. Magnetization measurements reveal its magnetic moment of 1.5 µ B in the solid phase, consistent with the existence of one unpaired electron predicted by density functional theory (DFT) calculations. Additionally, experimental measurements indicate the presence of ferromagnetic ordering within each Ni 3 S 3 H(PEt 3 ) 5 NC and strong coercivity at temperatures below 20 K. Ion mobility-mass spectrometry is employed in conjunction with DFT calculations and collision cross-section simulations to investigate the structure of the isolated Ni 3 S 3 H(PEt 3 ) 5 . Theoretical studies show that [Ni 3 S 3 H(PEt 3 ) 5 ] + has a planar Ni 3 S 3 core where three Ni atoms are arranged in a triangle with three bridging S atoms residing in the same plane. This structure is preserved in both solution and solid phases, which is confirmed by spectroscopic studies of Ni 3 S 3 H(PEt 3 ) 5 . Additionally, DFT calculations indicate that all spins at the Ni sites are aligned parallel, confirming the presence of ferromagnetic coupling. Overall, this study provides key insights into the structure and magnetic properties of Ni 3 S 3 H(PEt 3 ) 5 , which will facilitate the design of new NC-based magnetic materials.

Nickel sulfide nanocluster↗

High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features

Abstract High-resolution ion mobility (resolving power > 200) coupled with mass spectrometry (MS) is a powerful analytical tool for resolving isobars and isomers in complex samples. High-resolution ion mobility is capable of discerning additional structurally distinct features, which are not observed with conventional resolving power ion mobility (IM, resolving power ~ 50) techniques such as traveling wave IM and drift tube ion mobility (DTIM). DTIM in particular is considered to be the “gold standard” IM technique since collision cross section (CCS) values are directly obtained through a first-principles relationship, whereas traveling wave IM techniques require an additional calibration strategy to determine accurate CCS values. In this study, we aim to evaluate the separation capabilities of a traveling wave ion mobility structures for lossless ion manipulation platform integrated with mass spectrometry analysis (SLIM IM-MS) for both lipid isomer standards and complex lipid samples. A cross-platform investigation of seven subclass-specific lipid extracts examined by both DTIM-MS and SLIM IM-MS showed additional features were observed for all lipid extracts when examined under high resolving power IM conditions, with the number of CCS-aligned features that resolve into additional peaks from DTIM-MS to SLIM IM-MS analysis varying between 5 and 50%, depending on the specific lipid sub-class investigated. Lipid CCS values are obtained from SLIM IM ( TW(SLIM) CCS) through a two-step calibration procedure to align these measurements to within 2% average bias to reference values obtained via DTIM ( DT CCS). A total of 225 lipid features from seven lipid extracts are subsequently identified in the high resolving power IM analysis by a combination of accurate mass-to-charge, CCS, retention time, and linear mobility-mass correlations to curate a high-resolution IM lipid structural atlas. These results emphasize the high isomeric complexity present in lipidomic samples and underscore the need for multiple analytical stages of separation operated at high resolution. Graphical abstract

Reardon, Allison R. (ORCID:0000000165830134)↗

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-repeat and four-repeat tau isoforms form different oligomers

Different tauopathies are characterized by the isoform-specific composition of the aggregates found in the brain and by structurally distinct tau strains. Although tau oligomers have been implicated as important neurotoxic species, little is known about how the primary structures of the six human tau isoforms affect tau oligomerization because the oligomers are metastable and difficult to analyze. To address this knowledge gap, here, we analyzed the initial oligomers formed by the six tau isoforms in the absence of posttranslational modifications or other manipulations using dot blots probed by an oligomer-specific antibody, native-PAGE/western blots, photo-induced cross-linking of unmodified proteins, mass-spectrometry, and ion-mobility spectroscopy. We found that under these conditions, three-repeat (3R) isoforms are more prone than four-repeat (4R) isoforms to form oligomers. In this study, we also tested whether known inhibitors of tau aggregation affect its oligomerization using three small molecules representing different classes of tau aggregation inhibitors, Methylene Blue (MB), the molecular tweezer CLR01, and the all-D peptide TLKIVW, for their ability to inhibit or modulate the oligomerization of the six tau isoforms. Unlike their reported inhibitory effect on tau fibrillation, the inhibitors had little or no effect on the initial oligomerization. Our study provides novel insight into the primary–quaternary structure relationship of human tau and suggests that 3R-tau oligomers may be an important target for future development of compounds targeting pathological tau assemblies.

59 BASIC BIOLOGICAL SCIENCES↗