Field dependence of gaseous-ion mobility - Theoretical tests of approximate formulas.

The approximate formulas considered include relations based on the Wannier free-flight theory, the Kihara medium-field expansion, and the Frost-Patterson interpolation formulas. A few accurate theoretical results are available for testing the foregoing formulas. Cases concerning high fields, intermediate fields, and resonant charge transfer are examined. It is found that of the formulas tested, the one based on the Wannier free-flight theory is the most flexible, since it can be used for all fields and all ion-neutral force laws and mass ratios.

Hahn, H.↗

Pyrolysis Vacuum-Assisted Plasma Ionization Ion Mobility–Mass Spectrometry for Insoluble Polymer Analysis

Wire-based metal additive manufacturing utilizes the ability of additive manufacturing to fabricate complex geometries with high deposition rates (above 7 kg/h), thus finding applications in the fabrication of large-scale components, such as stamping dies. Traditionally, the workhorse materials for stamping dies have been martensitic steels. However, the complex thermal gyrations induced during additive manufacturing can cause the evolution of an inhomogeneous microstructure, which leads to a significant scatter in the mechanical properties, especially the toughness. Therefore, to understand these phenomena, arc-based additive AISI 410 samples were fabricated using robotic gas metal arc welding (GMAW) and were subjected to a detailed characterization campaign. The results show significant scatter in the tensile properties as well as Charpy V-notch impact toughness data, which was then correlated to the microstructural heterogeneity and delta (δ) ferrite formation. Post-processing (austenitizing and tempering) treatments were developed and an ~70% reduction in the scatter of tensile data and a four-times improvement in the toughness were obtained. The changes in mechanical properties were rationalized based on the microstructure evolution during additive manufacturing. Based on these, an outline to tailor the composition of “printable” steels for tooling with isotropic and uniform mechanical properties is presented and discussed.

36 MATERIALS SCIENCE↗

Combined Experimental and Computational Efforts to Establish Ion Mobility, Solubility and Stability of Functional Liquids for Electrochemical Energy Storage

This work provides a computation-driven investigation of the stability of organic electrolytes for lithium-air batteries. Electrolyte instability is currently a key challenge that limits practical use of aprotic Li-air batteries, and the chemical processes that cause this instability are often kinetically-driven. Computational screening for kinetic stability involves the determination of reaction barriers for the numerous potential reaction mechanisms, barriers that are challenging to calculate due to the difficulty of locating transition state structures. Here we screen a broad set of substituted electrolytes for susceptibility to nucleophilic attack by superoxide. We find that carbonates are not typically expected to be stable and that sulfones are generally stable, validating literature trends. We study the effects of chemical functionalization with electron-donating and withdrawing groups and their interplay with steric factors, identifying functional groups and other chemical modifications that increase stability in these groups. User-input driven transition state identification is used for these initial calculations, and an automated computational pipeline is subsequently presented and validated as a means to perform further high-throughput searches across mechanisms and chemistries. The pipeline integrates cheminformatics-based reaction encoding, relaxed potential energy scans, and nudged elastic band calculations for an end-to-end approach to barrier calculations. We review this automated search approach and its current limitations, and discuss challenges and further work.

25 ENERGY STORAGE↗

The effect of sample holder material on ion mobility spectrometry reproducibility

When a positive detection of a narcotic occurs during the search of a vessel, a decision has to be made whether further intensive search is warranted. This decision is based in part on the results of a second sample collected from the same area. Therefore, the reproducibility of both sampling and instrumental analysis is critical in terms of justifying an in depth search. As reported at the 2nd Annual IMS Conference in Quebec City, the U.S. Coast Guard has determined that when paper is utilized as the sample desorption medium for the Barringer IONSCAN, the analytical results using standard reference samples are reproducible. A study was conducted utilizing papers of varying pore sizes and comparing their performance as a desorption material relative to the standard Barringer 50 micron Teflon. Nominal pore sizes ranged from 30 microns down to 2 microns. Results indicate that there is some peak instability in the first two to three windows during the analysis. The severity of the instability was observed to increase as the pore size of the paper is decreased. However, the observed peak instability does not create a situation that results in a decreased reliability or reproducibility in the analytical result.

Jadamec, J. Richard↗

Classification of Ion Mobility Data Using the Neural Network Approach

Determination of atmospheric and surface elemental and molecular composition of various solar system bodies is essential to the development of a firm understanding of the origin and evolution of the solar system. Furthermore, such data is needed to address the intriguing question of whether or not life exists or once existed elsewhere in the Solar System. As such, these measurements are among the primary scientific goals of NASA s current and future planetary missions. In recent years, significant progress toward both miniaturization and field portability of in situ analytical separation and detection devices have been made with future planetary explorations in mind. However, despite all these advances, accurate in situ identification of atmospheric and surface compounds remains a big challenge. In response to that we are developing various hardware and software tools which would enable us to uniquely identify species of interest in a complex chemical environment.

Duong, T. A.↗

Mobilities of polyatomic ions in gases - Core model.

A core model, consisting of a (12-4) central potential displaced from the origin, is suggested as a representation of the interaction of polyatomic ions with neutral molecules. The diffusion collision integral, which describes ion mobility, is computed and tabulated as a function of temperature and core size. The addition of the core reduces the maximum in the mobility against temperature curve, and eventually reduces the mobility below its polarization limit at all temperatures. These results are in accord with limited available experimental data. Comparison is made with other models of ion-neutral interactions.

Mason, E. A.↗

Development of a Structure for Lossless Ion Manipulations (SLIM) High Charge Capacity Array of Traps

Enhancing the sensitivity of low abundance ions in a complex mixture without sacrificing experiment throughput is highly desirable. This work demonstrates a way to greatly improve the sensitivity of ion mobility (IM) selected ions by accumulating them in an array of high-capacity ion traps located inside a novel structures for lossless ion manipulations ion mobility spectrometer (SLIM-IMS) module. The array of ion traps used in this work consisted of seven independently controllable traps. Each trap was 386 mm long and possessed a charge capacity of ~4.5×10 8 charges, with a linear range extending to ~2.5×10 8 charges. Each ion trap could be used to extract a peak (or ions over a mobility range) from an ion mobility separation based on arrival time. Ions could be stored without losses for long times (>100 s) and then released all at once or one trap at a time. It was possible to accumulate large ion populations by extracting and storing ions over repeated IM separations. We report enrichment of up to seven individual ion distributions could be performed using the seven independently controllable ion traps. Additionally, the ion trapping process effectively compressed ion populations into narrow peaks, which provides a greatly improved basis for subsequent ion manipulations. The array of high charge-capacity ion traps provides a flexible addition to SLIM and a powerful tool for IMS-MS applications requiring high sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗