Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “iodine management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Recommended Updates to Solubility Controls for Modeling Leaching of Technetium, Uranium, Neptunium, Plutonium, and Iodine from the Residual Waste Layer of Closed Savannah River Site High Level Waste Tanks

The objective of this report is to relate waste leaching experiments by the Savannah River National Laboratory (SRNL) to performance assessment modeling of release of several radionuclides from residual waste in closed high-level waste tanks. SRNL leached residual waste from Tanks 18F and 12H with solutions simulating the modeled evolution of pore fluids in residual waste layers of closed tanks through various stages of grout degradation. Tc-99, uranium isotopes, Np-237, plutonium isotopes, and I-129 were analyzed in the leachate multiple times over 90 days.

07 ISOTOPE AND RADIATION SOURCES↗

Vadose Zone Model for LLBG-218-E-10 for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort; carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for LW Crib Area for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort: carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensor Needs for Advanced Life Support

Sensors and feedback systems are critical to life support flight systems and life support systems research. New sensor capabilities can allow for new system architectures to be considered, and can facilitate dramatic improvements in system performance. This paper will describe three opportunities for biosensor researchers to develop sensors that will enable life support system improvements. The first opportunity relates to measuring physical, chemical, and biological parameters in the Space Station Water Processing System. Measuring pH, iodine, total organic carbon, microbiological activity, total dissolved solids, or conductivity with a safe, effective, stable, reliable microsensor could benefit the water processing system considerably. Of special interest is a sensor which can monitor biological contamination rapidly. The second opportunity relates to sensing microbiological contamination and water condensation on the surface of large inflatable structures. It is the goal of large inflatable structures used for habitation to take advantage of the large surface area of the structure and reject waste heat passively through the walls of the structure. Too much heat rejection leads to a cold spot with water condensation, and eventually microbiological contamination. A distributed sensor system that can measure temperature, humidity, and microbiological contamination across a large surface would benefit designers of large inflatable habitable structures. The third opportunity relates to sensing microbial bioreactors used for waste water processing and reuse. Microbiological bioreactors offer considerable advantages in weight and power compared to adsorption bed based systems when used for long periods of time. Managing and controlling bioreactors is greatly helped if distributed microsensors measured the biological populations continuously in many locations within the bioreactor. Nitrifying bacteria are of special interest to bioreactor designers, and any sensors that could measure the populations of these types of bacteria would help the control and operation of bioreactors. J

Graf, John C.↗

FY2021 Rotating Bed Reactor for Iodine Removal from ETF Feed to Support DFLAW Start-Up

In FY20, Washington River Protection Solutions, LLC (WRPS) began a program of work to evaluate potential technologies for removal of iodine from the ETF feed. Work at the Pacific Northwest National Laboratory (PNNL) focused on ion exchange media and conventional column based deployment while Atkins and VSL focused on ion exchange media in a Rotating Bed Reactor (RBR) system. In the RBR system, the ion exchange media is loaded into a packed bed, which is rotated in the liquid to be treated. The work described in this report builds on the results from FY20 work, in particular, with regard to improving iodate removal, extending the data set to support process modeling, further comparison of RBR versus column performance, and RBR scale-up testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dual-Bed Radioiodine Capture from Complex Gas Streams with Zeolites: Regeneration and Reuse of Primary Sorbent Beds for Sustainable Waste Management

Dual-sorbent systems are proposed for radioiodine management with a regenerated primary bed for multiple cycles of use in complex conditions and a secondary bed for disposal with higher waste loadings. Sorbent approaches for the effective capture of gaseous radioiodine (isotopes 129 I and 131 I) produced from a range of nuclear processes have been studied for over half a century. (1−5) Whether or not a sorbent (e.g., molecular sieve) is required to physically screen/trap or chemically bind a radionuclide of interest through chemisorption, the complexity of the gas stream has a large impact on the performance (e.g., loading capacity, selectivity) and active life of a sorbent bed. (3) Silver mordenite (AgZ), the U.S. Department of Energy baseline sorbent for radioiodine capture from nuclear processes, performs well within acidic conditions and at elevated temperatures (6) and can be consolidated into a chemically durable waste form for long-term disposal. (7,8) However, new sorbents are being sought because optimal capture performance of AgZ significantly decreases in dynamic oxidizing environments with competing species, and it is expensive and it contains Ag (a toxic metal). (9) Until a new sorbent is found to replace AgZ, the regeneration and reuse of AgZ is an attractive alternative to a single-use primary sorbent bed. In this regard, a primary sorbent could be designed for enhanced capture in complex gas streams and the ability to be regenerated for reuse. Here, a secondary sorbent could then be tailored for maximum iodine loading in the gas stream and chemical durability within a disposal facility.

chemisorption↗

Review of Experimental Decontamination Factors (DF) of Iodine in the Pilot-Scale Law Melter Off-Gas Systems

The Low Activity Waste (LAW) melters at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will convert low-activity tank wastes containing high concentrations of sodium salts into glass for onsite disposal. Much of the airborne particulates during the calcination/fusion of the feed solids will be removed by condensation and scrubbing of the melter exhaust in the Submerged Bed Scrubber (SBS) and Wet Electrostatic Precipitator (WESP)of the primary off-gas treatment system. The gases exiting the WESP enter a secondary off-gas treatment system, which includes a High-Efficiency Particulate Air (HEPA) filter, an activated carbon absorber, a Thermal Catalytic Oxidizer (TCO), a Selective Catalytic Reduction (SCR) unit, a caustic scrubber, and an exhauster. Much of the volatile organics and NOx will be removed in the TCO and SCR, respectively. Under WTP Direct Feed LAW (DFLAW) configuration, the liquid effluents from the SBS and WESP will be collected and evaporated under vacuum with the evaporator concentrate recycled back to the LAW melter, while the evaporator condensate will be merged with the caustic scrubber solution and sent to the Effluent Treatment Facility (ETF).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Models to Incorporate Reaction Mechanisms into DG-OSPREY: Fixed-Bed Simulations for Organic Iodides Capture Using Ag 0 Z

As one of the most potent radioisotopes released during spent nuclear fuel reprocessing, 129 I is strictly regulated and must be removed before discharge. Organic iodides (primarily alkyl iodides with different chain lengths, i.e., CH 3 I, C 4 H 9 I, and C 12 H 25 I) comprise ~2% of the total iodine in the reprocessing off-gases and are primarily present in vessel off-gas (VOG). Reduced silver mordenite (Ag 0 Z) is predominantly considered for the removal of radioiodine; however, its capture performance and underlying interaction processes with long-chain organic iodides are not fully understood. Two major tasks were accomplished in this study. First, to improve upon the previous experimental studies where Ag 0 Z was used to capture CH 3 I, C 4 H 9 I, and C 12 H 25 I at different concentrations, we comprehensively investigated the corresponding capture mechanisms by characterizing fully loaded Ag 0 Z samples. Second, computational codes were implemented to perform fixed-bed simulations that account for transport and reaction mechanisms. Scanning electron microscopy with energy dispersive X-ray analysis (SEM-EDX), powder X-ray diffraction (PXRD), UV-visible diffuse reflectance spectroscopy (UV-vis DRS), and thermogravimetric analysis (TGA) were conducted on Ag 0 Z samples that are saturated with I 2 , CH 3 I, C 4 H 9 I, and C 12 H 25 I), respectively. Results indicate that AgI is the predominant adsorption product regardless of the adsorbed iodine species, yet alkyl iodides with different carbon chain lengths may have different compositions of α- and γ-AgI. Synchrotron pair distribution function (PDF) measurements and TGA coupled with a Fourier transformed infrared detector (TGA FTIR) have been performed, and experimental data are currently analyzed. Results are expected to provide further insights into the adsorption mechanisms. The fixed-bed capture performance for CH 3 I was successfully simulated by solving mathematical equations that describe the underlying transport processes and adsorption reactions. The computational framework, Catalytic After Treatment System (CATS), that was originated in our research group, was used to solve the governing equations. Kinetic parameters, including the pore diffusivity and reaction rate constant were obtained by optimization techniques using data from thin-bed experiments performed at Oak Ridge National Laboratory. The performance of a deep bed predicted using the optimized parameters showed promising agreement with the experimental data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preparation of iodine-bearing waste forms for hot isostatic pressing

Oak Ridge National Laboratory (ORNL) has prepared a new set of iodine-bearing sorbents. The sorbent materials used for this activity were supplied by IONEX (NexSorb-99) or C&CS (AC6120-7%). Metal canisters were previously prepared by ORNL in 2022. They are 2 in. long by 1.5 in. in diameter and are made of 316 stainless steel.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Roadmap to Iodine and Mercury Abatement Materials Selection in Nuclear Waste Processing Off-Gas Streams

This work provides a guide for candidate mercury (Hg) and iodine-129 (129I) abatement material identification, screening, evaluation, technical gap identification, and bench-scale testing prioritization while also conceptualizing a materials deployment roadmap for implementation of new materials in the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility at Hanford in Richland, Washington, and elsewhere in the U.S. Department of Energy (DOE) complex for similar applications. The study was prompted by the need to replace the Kombisorb BAT-37 due to uncertainties in Hg and 129I capture performance and future availability for use in the WTP LAW Facility secondary off-gas system, specifically the Carbon Adsorber units. However, replacement of this material could also mitigate two other issues with Kombisorb BAT-37 (and its successor BAT II 37): (1) fire safety risk due to exothermic heat generated by adsorption reactions between the carbon material and Hg and (2) the risk of low retention of 129I in glass and subsequent downstream impacts on secondary liquid waste treatment at the Effluent Treatment Facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Contaminants and Mobility in WMA A-AX Boreholes D0006 and D0008

This study was initiated to determine if subsurface contaminants in the A-AX vadose zone at the Hanford site (boreholes D0006 and D0008) caused corrosion of nearby stainless steel well casings (299-E-24-19, 299-E25-46, and 299-E25-236) and, based on the type and distribution of contaminants, determine if contaminants are from one or more sources including a) the A-104 and/or A-105 tanks, b) the 242A evaporator, and c) the 200-E-286 ditch. A tiered approach was used for characterizing contaminants in vadose zone sediments starting with mobile and total contaminant concentrations (Tier 1), characterizing contaminant speciation (Tier 2), and measuring contaminant leaching (Tier 3). Total and mobile contaminant measurements at seven depths showed elevated sulfate and nitrate in all samples (130 to 280 ft depth), elevated chloride in five depths, and no elevated radionuclides except I-129 in D0006 at 206 to 208 ft depth. If these contaminants were initially acidic, stainless-steel corrosion would occur. However, because sediments likely have a high acid neutralization capacity, an acidic spill would have been neutralized within tens of feet, so casing corrosion would likely occur in shallow sediments. GEL labs data also shows low (but above natural) chromate from shallow to 170 ft depth, then higher chromate to 280 ft, suggesting a surface Cr spill or casing corrosion. GEL labs data also showed evidence of more than one plume, with deep nitrate, sulfate, and chloride migration, but only shallow tritium migration. Tritium should migrate nearly unretarded in the subsurface like nitrate and chloride. Elevated aqueous cations and anions in the D0006 206 to 208' depth pore water (SO 4 2- , NO 3 - , Na + , K + , Ca 2+ , Mg 2+ , Si) could be the result of acid disposal and calcite dissolution at shallow depth, with deeper migration of SO 4 2- , NO 3 - from acids and Ca 2+ and Mg 2+ from calcite. Elevated Si (160 mg/L) indicates dissolution of clays or other silicates, which can also occur in acids. Acid extractable metals did show elevated Cr (but not Fe, Ni, Mo, and Mn) above natural levels, which may indicate stainless-steel well corrosion or transport of metals from a shallow spill. The elevated I-129 in D0006 at 206 to 208' depth was low with 0.34 μg/g in pore water and 1.5 μg/g total extractable I-129 in the sediment, which indicates significant fraction of I-129 was bound in one or more precipitates. Although total I-129 was below detection limits in most extractions due to high molybdate interference, I-127 analysis provided some insight into potential precipitate phases. Total I-127 was mainly extracted by acetate or acetic acid (67%), which may be iodine in calcite. Inorganic carbon measurement identified 1.65% calcite, and total organic carbon (TOC) was below detection limits, so iodine was not associated with organic matter. Nearly all the I-127 was present as iodide. In 1-D leach experiments, I-127 as iodide leached from the sediment within 2 pore volumes. Due to high and dynamic molybdate leaching from the sediment and interference with I-129 analysis, there were few quantifiable I-129 measurements. The calculated molybdate release rates from the sediment suggested Mo was being released from the same precipitate phase, such as molybdate incorporated into calcite. Overall, because there was little radioactive contamination measured in D0006 and D0008 boreholes, potential releases from A-104 and A-105 did not reach this location south of the A tank farm. Elevated cations and anions found in D0006 and D0008 at depth as the result of acidic disposal could cause shallow stainless steel casing corrosion. The nearby 242A evaporator generally contained alkaline waste and tritium, but the nearby 200-E-286 ditch generally contained high Cl - liquid effluent, so these are unlikely to be acidic sources.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of oxidation and carbonation on the release rates of iodine, selenium, technetium, and nitrogen from a cementitious waste form

Evaluation of the long-term retention mechanisms and potential release rates for the primary constituents of potential concern (COPCs) (i.e., Tc, I, Se, and nitrate) is necessary to determine if Cast Stone, a radioactive waste form, can meet performance objectives under near-surface disposal scenarios. In this work, a mineral and parameter set accounting for the solubility of I and Se in Cast Stone was developed based on pH-dependent and monolithic diffusion leaching test results, to extend a geochemical speciation model previously developed. The impact of oxidation and carbonation as environmental aging processes on the retention properties of Cast Stone for primary COPCs was systematically estimated. Physically, the effective diffusion coefficients of 4 COPCs in Cast Stone were increased after carbonation and/or oxidation, reflecting an increase in permeability to diffusion. Chemically, i) pH & pe conditions in the original Cast Stone were favorable for the stabilization of Tc, but not for I, Se, and N; ii) oxidation (with/without carbonation) of Cast Stone changed the pe & pH conditions to be detrimental for Tc stabilization; and iii) carbonation (with/without oxidation) of Cast Stone modified the pH & pe conditions to be beneficial for the stabilization of I (in system with Ag added) and Se.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification of Hanford Tank 241-AP-101 Waste and Simulant

Hanford tank 241-AP-101 (referred to herein as AP-101) is the second Hanford radioactive tank waste planned to be processed and vitrified. A simulant version of AP 101 waste was formulated from the best-basis inventory (BBI) for the Hanford Tank 241-AP-101 liquid with an assumed target dilution of the waste from the BBI sodium molarity of 8.61 M to the desired 5.5 M Na. After the addition of glass-forming chemicals (GFCs), the simulant melter feed was processed in a non-radioactive, continuous laboratory-scale melter (CLSM) system. The AP-101 simulant melter feed was charged into the CLSM for 6.11 h of processing, which produced 6.55 kg of glass, for an average glass production rate of 2275 kg m 2 d -1 . Since there were no processing issues with the AP-101 simulant melter feed, AP-101 melter feed made with actual waste was then processed in a CLSM system built into a contamination area in a radioactive environment. The melting behavior characteristics appeared similar for both the simulant and waste melter feeds. The AP-101 waste melter feed was charged into the CLSM for 12.14 h of processing, which produced 8.75 kg of glass, for an average glass production rate of 1530 kg m 2 d -1 . During the AP-101 waste melter feed charging, the pump used to move the feed reached a maximum and it is believed that if the pump had a greater capacity, a greater average glass production rate could have been achieved. A constituent of interest present in low quantities in the AP-101 waste is 99 Tc or its non-radioactive surrogate, Re, added to the AP-101 simulant. Analysis for the quantities of 99 Tc and Re in the AP-101 glass product resulted in an average single-pass retention from the melter feed during relative chemical steady state of 55 ± 2 % for 99 Tc and 45 ± 2 % for Re. Compared to the processing of other melter feeds, the retention of 99 Tc in the AP-101 glass was greater than in both AP-107 and AP-105 glass, while the retention of Re in the AP-101 was less than in the AP-107 glass, but greater than in the AP-105 glass. A spike of I was added into the AP-101 melter feed that could be detected above the analysis detection limits. However, the iodine was only detectable above the ~6 ppm limit in one glass pour: the pour immediately following the burn off of the cold cap, where the I level reached ~30 ppm. This event was significant because the glass was poured immediately after burn off and thus it is presumed that the iodine had yet to volatilize from the glass melt while idling. It is recommended to perform future tests with I spikes at greater levels so that it can be detected in additional glass pours to determine if the expected 50 % retention of I used in the Kim et al. glass models can be confirmed. Offgas liquid samples were analyzed for acetonitrile, which was present at greater concentrations in CLSM liquids than in other scaled melter systems. This result was expected based on unique conditions with the CLSM system including a small plenum space leading to low residence time for offgas and the rapidity of offgas cooling upon exiting the CLSM vessel due to the location and environment. About 90 % of the total acetonitrile captured during both the AP-101 simulant and waste CLSM runs was found in the offgas condensate and demister liquids, thus it is recommended that only those liquids be sent for analysis if future testing to study the presence of acetonitrile in offgas products is desired.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for B-3A/B Pond for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort; carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP) simulator officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain. The Hanford Site Central Plateau was subdivided into 26 individual vadose zone models, with 13 in the 200 East Area and 13 in the 200 West Area. Waste sites that have a completed performance assessment (PA) or past-leak analysis were not included as sources of radionuclides. Instead the vadose zone to groundwater transfer rates of the Environmental Restoration Disposal Facility, Integrated Disposal Facility, US Ecology, and Waste Management Area C (WMA C) PAs and the past-leak analysis for WMA C were used as direct input to the P2R model. Each of the vadose zone models is documented in separate environmental calculation files (ECFs). This ECF describes the B-3A/B Ponds model. The scope of this ECF is to document the development and results of the B-3 A/B Ponds vadose zone model. CP-63515, Model Package Report: Central Plateau Vadose Zone Models, describes the approach, assumptions, process of determining the number of models required and domain of each model, input data, and processing common to all the models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for SALDS for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort: carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP1) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP) is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain. The Hanford Site Central Plateau was subdivided into 26 individual vadose zone models, with 13 in the 200 East Area and 13 in the 200 West Area. Waste sites that have a completed performance assessment (PA) or past-leak analysis were not included as sources of radionuclides. Instead the vadose zone to groundwater transfer rates of the Environmental Restoration Disposal Facility, Integrated Disposal Facility, US Ecology, and Waste Management Area C (WMA C) PAs and the past-leak analysis for WMA C were used as direct input to the P2R model. Each of the vadose zone models is documented in separate environmental calculation files (ECFs). This ECF describes the State-Approved Land Disposal Site (SALDS) model. The scope of this ECF is to document the development and results of the SALDS vadose zone model. CP-63515, Model Package Report: Central Plateau Vadose Zone Models, describes the approach, assumptions, process of determining the number of models required and domain of each model, input data, and processing common to all the models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for S Farms Area for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed "dry" in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort: carbon-14 (C-14), chloiine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thmium-230 (Th-230). The simulation time struts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP) simulator, officially named the exascale Subsurface Transport Over Multiple Phases ( eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user's guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User 's Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Composite Analysis: LLBG-200-W B Vadose Zone Model

The objectives of the vadose modeling for the updated Hanford Site Composite Analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates to the CA saturated zone model (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort: carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP 1 ) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the saturated zone model. The rates will be summed over the 100 by 100 m saturated zone model grid cells that fall within the vadose zone model source domain.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vadose Zone Model for B-63 Area for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort; carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP1) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗