Optical timing receiver for the NASA laser ranging system. Part 2: High precision time interval digitizer

The development of a high precision time interval digitizer is described. The time digitizer is a 10 psec resolution stop watch covering a range of up to 340 msec. The measured time interval is determined as a separation between leading edges of a pair of pulses applied externally to the start input and the stop input of the digitizer. Employing an interpolation techniques and a 50 MHz high precision master oscillator, the equivalent of a 100 GHz clock frequency standard is achieved. Absolute accuracy and stability of the digitizer are determined by the external 50 MHz master oscillator, which serves as a standard time marker. The start and stop pulses are fast 1 nsec rise time signals, according to the Nuclear Instrument means of tunnel diode discriminators. Firing level of the discriminator define start and stop points between which the time interval is digitized.

Leskovar, B.↗

Department of Defense Precise Time and Time Interval program improvement plan

The United States Naval Observatory is responsible for ensuring uniformity in precise time and time interval operations including measurements, the establishment of overall DOD requirements for time and time interval, and the accomplishment of objectives requiring precise time and time interval with minimum cost. An overview of the objectives, the approach to the problem, the schedule, and a status report, including significant findings relative to organizational relationships, current directives, principal PTTI users, and future requirements as currently identified by the users are presented.

Bowser, J. R.↗

Nonlogarithmic magnetization relaxation at the initial time intervals and magnetic field dependence of the flux creep rate in Bi2Sr2Ca(sub I)Cu2Ox single crystals

At the initial time intervals, preceding the thermally activated flux creep regime, fast nonlogarithmic relaxation is found. The fully magnetic moment Pm(t) relaxation curve is shown. The magnetic measurements were made using SQUID-magnetometer. Two different relaxation regimes exist. The nonlogarithmic relaxation for the initial time intervals may be related to the viscous Abrikosov vortices flow with j is greater than j(sub c) for high enough temperature T and magnetic field induction B. This assumption correlates with Pm(t) measurements. The characteristic time t(sub O) separating two different relaxation regimes decreases as temperature and magnetic field are lowered. The logarithmic magnetization relaxation curves Pm(t) for fixed temperature and different external magnetic field inductions B are given. The relaxation rate dependence on magnetic field, R(B) = dPm(B, T sub O)/d(1nt) has a sharp maximum which is similar to that found for R(T) temperature dependences. The maximum shifts to lower fields as temperature goes up. The observed sharp maximum is related to a topological transition in shielding critical current distribution and, consequently, in Abrikosov vortices density. The nonlogarithmic magnetization relaxation for the initial time intervals is found. This fast relaxation has almost an exponentional character. The sharp relaxation rate R(B) maximum is observed. This maximum corresponds to a topological transition in Abrikosov vortices distribution.

Moshchalcov, V. V.↗

ISEE 3 observations during the CDAW 8 intervals - Case studies of the distant geomagnetic tail covering a wide range of geomagnetic activity

Observations made by the ISEE 3 spacecraft in the distant geomagnetic tail during the eight CDAW 8 intervals are discussed, along with their relation to concurrent geomagnetic activity. This extensive multiinstrument case study of distant tail data covers a wide range of geomagnetic conditions from extended intervals of magnetic quiet with isolated substorms to prolonged periods of intense disturbance. Plasmoids are observed in the distant tail following disturbance enhancements, the time of their appearance being generally consistent with disconnection from the near-earth region at the time of the enhancement. Their structure is entirely consistent with the neutral line model. However, not all enhancements in geomagnetic activity result in the observation of plasmoids. In particular, the CDAW 8 data suggest that, during extended intervals of strong activity, a continuous neutral line may reside in the near-earth tail and some disturbance enhancements may then relate to an increase in the reconnection rate at a preexisting neutral line, rather than to new neutral line and plasmoid formation.

Richardson, I. G.↗

Interval polynomial positivity

It is shown that a univariate interval polynomial is globally positive if and only if two extreme polynomials are globally positive. It is shown that the global positivity property of a bivariate interval polynomial is completely determined by four extreme bivariate polynomials. The cardinality of the determining set for k-variate interval polynomials is 2k. One of many possible generalizations, where vertex implication for global positivity holds, is made by considering the parameter space to be the set dual of a boxed domain.

Bose, N. K.↗

Boundary implications for frequency response of interval FIR and IIR filters

It is shown that vertex implication results in parameter space apply to interval trigonometric polynomials. Subsequently, it is shown that the frequency responses of both interval FIR and IIR filters are bounded by the frequency responses of certain extreme filters. The results apply directly in the evaluation of properties of designed filters, especially because it is more realistic to bound the filter coefficients from above and below instead of determining those with infinite precision because of finite arithmetic effects. Illustrative examples are provided to show how the extreme filters might be easily derived in any specific interval FIR or IIR filter design problem.

Bose, N. K.↗

Interval prediction in structural dynamic analysis

Methods for assessing the predictive accuracy of structural dynamic models are examined with attention given to the effects of modal mass, stiffness, and damping uncertainties. The methods are based on a nondeterministic analysis called 'interval prediction' in which interval variables are used to describe parameters and responses that are unknown. Statistical databases for generic modeling uncertainties are derived from experimental data and incorporated analytically to evaluate responses. Covariance matrices of modal mass, stiffness, and damping parameters are propagated numerically in models of large space structures by means of three methods. The test data tend to fall within the predicted intervals of uncertainty determined by the statistical databases. The present findings demonstrate the suitability of using data from previously analyzed and tested space structures for assessing the predictive accuracy of an analytical model.

Hasselman, Timothy K.↗

ISEE 3 plasmoid and TCR observations during an extended interval of substorm activity

On April 9-11, 1983, the ISEE 3 spacecraft was continuously located within the earth's magnetotail for more than 36 hours at downstream distances of X = -76 to -80 R(e). During this span of time, 12 major intervals of substorm activity were observed in the AL index with good ISEE 3 telemetry coverage for 11 of them. In addition, there were two small substorms outside of these intervals, both with complete observations in the distant tail. This unusual ISEE 3 data set provides a unique opportunity to test the predictions of the near-earth neutral line model. In particular, the hypothesis that energy stored in the tail lobes during the growth phase is later dissipated, in part, through the release of one or more plasmoids following expansion phase onset is examined. Clear growth phase enhancements in the lobe magnetic field intensity preceded the onsets of nine of the substorms. Plasmoids, or their lobe signatures, traveling compression regions (TCRs), were observed at ISEE 3 in association with all 11 of the major substorm intervals for which there were ISEE observations, as well as for the two small substorms. No plasmoids or TCRs were observed in the absence of substorm activity. If these ISEE 3 observations are representative, then the release of plasmoids down the tail may be a feature common to all substorms.

Slavin, J. A.↗

Stability margins for multilinear interval systems by way of phase conditions: A unified approach

A simple way of checking the stability with respect to an arbitrary stability region of a family of polynomials containing a vector of parameters varying within prescribed intervals is discussed. It is assumed that the parameters appear affine multilinearly in the characteristic polynomial coefficients. The condition proposed is simply to check the phase difference of the vertex polynomials. This test based on the mapping theorem significantly reduces computational complexity. Mathematical proofs are omitted. The results can be used to determine various stability margins of control systems containing interconnected interval subsystems. These include the gain, phase, time-delay, H(sup infinity), and nonlinear sector bounded stability margins of multilinear interval systems.

Keel, L. H.↗

Interval estimates for closure-phase and closure-amplitude imaging in radio astronomy

Interval estimates for closure-phase and closure-amplitude imaging that enable the reconstruction of a radioimage from results of approximate measurements are presented. If the intervals for the measured values are known, the precision of the result of the reconstruction cannot be solved by standard interval methods, because the phase value is based on a circle but not on a real line. If the phase theta (x bar) is measured with precision epsilon, so that the closure phase theta (x bar) + theta (y bar) - theta (x bar + y bar) is known with precision 3 epsilon, then from these measurements theta can be reconstructed with precision 6 epsilon. Similar estimates are given for closure amplitude.

Kreinovich, Vladik↗

Precision Interval Estimation of the Response Surface by Means of an Integrated Algorithm of Neural Network and Linear Regression

The integration of Radial Basis Function Networks and Back Propagation Neural Networks with the Multiple Linear Regression has been accomplished to map nonlinear response surfaces over a wide range of independent variables in the process of the Modem Design of Experiments. The integrated method is capable to estimate the precision intervals including confidence and predicted intervals. The power of the innovative method has been demonstrated by applying to a set of wind tunnel test data in construction of response surface and estimation of precision interval.

Lo, Ching F.↗

Contributions of tidal lung inflation to human R-R interval and arterial pressure fluctuations

We studied the effects of mechanical lung inflation on respiratory frequency R-R interval and arterial pressure fluctuations in nine healthy young adults undergoing elective orthopedic surgery. We conducted this research to define the contribution of pulmonary and thoracic stretch receptor input to respiratory sinus arrhythmia. We compared fast Fourier transform spectral power during three modes of ventilation: (1) spontaneous, frequency-controlled (0.25 Hz) breathing, (2) intermittent positive pressure ventilation (0.25 Hz, with a tidal volume of 8 ml/kg) and (3) high frequency jet ventilation (5.0 Hz, 2.5 kg/cm2), after sedation and vecuronium paralysis. Mean R-R intervals, arterial pressures and arterial blood gas levels were comparable during all three breathing conditions. Respiratory frequency systolic pressure spectral power was comparable during spontaneous breathing and conventional mechanical ventilation, but was significantly reduced during high frequency jet ventilation (P < 0.05). Respiratory frequency R-R interval spectral power (used as an index of respiratory sinus arrhythmia) declined dramatically with sedation and muscle paralysis (P < 0.05), but was greater during conventional mechanical, than high frequency jet ventilation (P < 0.05). These results suggest that although phasic inputs from pulmonary and thoracic stretch receptors make a statistically significant contribution to respiratory sinus arrhythmia, that contribution is small.

Clinical Trial↗

Power law behavior of RR-interval variability in healthy middle-aged persons, patients with recent acute myocardial infarction, and patients with heart transplants

BACKGROUND. The purposes of the present study were (1) to establish normal values for the regression of log(power) on log(frequency) for, RR-interval fluctuations in healthy middle-aged persons, (2) to determine the effects of myocardial infarction on the regression of log(power) on log(frequency), (3) to determine the effect of cardiac denervation on the regression of log(power) on log(frequency), and (4) to assess the ability of power law regression parameters to predict death after myocardial infarction. METHODS AND RESULTS. We studied three groups: (1) 715 patients with recent myocardial infarction; (2) 274 healthy persons age and sex matched to the infarct sample; and (3) 19 patients with heart transplants. Twenty-four-hour RR-interval power spectra were computed using fast Fourier transforms and log(power) was regressed on log(frequency) between 10(-4) and 10(-2) Hz. There was a power law relation between log(power) and log(frequency). That is, the function described a descending straight line that had a slope of approximately -1 in healthy subjects. For the myocardial infarction group, the regression line for log(power) on log(frequency) was shifted downward and had a steeper negative slope (-1.15). The transplant (denervated) group showed a larger downward shift in the regression line and a much steeper negative slope (-2.08). The correlation between traditional power spectral bands and slope was weak, and that with log(power) at 10(-4) Hz was only moderate. Slope and log(power) at 10(-4) Hz were used to predict mortality and were compared with the predictive value of traditional power spectral bands. Slope and log(power) at 10(-4) Hz were excellent predictors of all-cause mortality or arrhythmic death. To optimize the prediction of death, we calculated a log(power) intercept that was uncorrelated with the slope of the power law regression line. We found that the combination of slope and zero-correlation log(power) was an outstanding predictor, with a relative risk of > 10, and was better than any combination of the traditional power spectral bands. The combination of slope and log(power) at 10(-4) Hz also was an excellent predictor of death after myocardial infarction. CONCLUSIONS. Myocardial infarction or denervation of the heart causes a steeper slope and decreased height of the power law regression relation between log(power) and log(frequency) of RR-interval fluctuations. Individually and, especially, combined, the power law regression parameters are excellent predictors of death of any cause or arrhythmic death and predict these outcomes better than the traditional power spectral bands.

Non-NASA Center↗

Use of Data Comm by Flight Crew to Conduct Interval Management Operations to Parallel Dependent Runways

The Interval Management (IM) concept is being developed as a method to maintain or increase high traffic density airport arrival throughput while allowing aircraft to conduct near idle thrust descents. The Interval Management with Spacing to Parallel Dependent Runways (IMSPiDR1) experiment at NASA Langley Research Center used 24 commercial pilots to examine IM procedures to conduct parallel dependent runway arrival operations while maintaining safe but efficient intervals behind the preceding aircraft. The use of IM procedures during these operations requires a lengthy and complex clearance from Air Traffic Control (ATC) to the participating aircraft, thereby making the use of Controller Pilot Data Link Communications (CPDLC) highly desirable as the communication method. The use of CPDLC reduces the need for voice transmissions between controllers and flight crew, and enables automated transfer of IM clearance elements into flight management systems or other aircraft avionics. The result is reduced crew workload and an increase in the efficiency of crew procedures. This paper focuses on the subset of data collected related to the use of CPDLC for IM operations into a busy airport. Overall, the experiment and results were very successful, with the mean time under 43 seconds for the flight crew to load the clearance into the IM spacing tool, review the calculated speed, and respond to ATC. An overall mean rating of Moderately Agree was given when the crews were asked if the use of CPDLC was operationally acceptable as simulated in this experiment. Approximately half of the flight crew reported the use of CPDLC below 10,000 for IM operations was unacceptable, with 83% reporting below 5000 was unacceptable. Also described are proposed modifications to the IM operations that may reduce CPDLC Respond time to less than 30 seconds and should significantly reduce the complexity of crew procedures, as well as follow-on research issues for operational use of CPDLC during IM operations.

Baxley, Brian T.↗

Experiment Description and Results for Arrival Operations Using Interval Management with Spacing to Parallel Dependent Runways (IMSPiDR)

The predicted increase in the number of commercial aircraft operations creates a need for improved operational efficiency. Two areas believed to offer increases in aircraft efficiency are optimized profile descents and dependent parallel runway operations. Using Flight deck Interval Management (FIM) software and procedures during these operations, flight crews can achieve by the runway threshold an interval assigned by air traffic control (ATC) behind the preceding aircraft that maximizes runway throughput while minimizing additional fuel consumption and pilot workload. This document describes an experiment where 24 pilots flew arrivals into the Dallas Fort-Worth terminal environment using one of three simulators at NASA?s Langley Research Center. Results indicate that pilots delivered their aircraft to the runway threshold within +/- 3.5 seconds of their assigned time interval, and reported low workload levels. In general, pilots found the FIM concept, procedures, speeds, and interface acceptable. Analysis of the time error and FIM speed changes as a function of arrival stream position suggest the spacing algorithm generates stable behavior while in the presence of continuous (wind) or impulse (offset) error. Concerns reported included multiple speed changes within a short time period, and an airspeed increase followed shortly by an airspeed decrease.

Baxley, Brian T.↗

Acceptability of Flight Deck-Based Interval Management Crew Procedures

The Interval Management for Near-term Operations Validation of Acceptability (IM-NOVA) experiment was conducted at the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) in support of the NASA Next Generation Air Transportation System (NextGen) Airspace Systems Program's Air Traffic Management Technology Demonstration - 1 (ATD-1). ATD-1 is intended to showcase an integrated set of technologies that provide an efficient arrival solution for managing aircraft using NextGen surveillance, navigation, procedures, and automation for both airborne and ground-based systems. The goal of the IM-NOVA experiment was to assess if procedures outlined by the ATD-1 Concept of Operations, when used with a minimum set of Flight deck-based Interval Management (FIM) equipment and a prototype crew interface, were acceptable to and feasible for use by flight crews in a voice communications environment. To investigate an integrated arrival solution using ground-based air traffic control tools and aircraft automatic dependent surveillance broadcast (ADS-B) tools, the LaRC FIM system and the Traffic Management Advisor with Terminal Metering and Controller Managed Spacing tools developed at the NASA Ames Research Center (ARC) were integrated in LaRC's Air Traffic Operations Laboratory. Data were collected from 10 crews of current, qualified 757/767 pilots asked to fly a high-fidelity, fixed based simulator during scenarios conducted within an airspace environment modeled on the Dallas-Fort Worth (DFW) Terminal Radar Approach Control area. The aircraft simulator was equipped with the Airborne Spacing for Terminal Area Routes algorithm and a FIM crew interface consisting of electronic flight bags and ADS-B guidance displays. Researchers used "pseudo-pilot" stations to control 24 simulated aircraft that provided multiple air traffic flows into DFW, and recently retired DFW air traffic controllers served as confederate Center, Feeder, Final, and Tower controllers. Pilot participant feedback indicated that the procedures used by flight crews to receive and execute interval management (IM) clearances in a voice communications environment were logical, easy to follow, did not contain any missing or extraneous steps, and required the use of an acceptable level of workload. The majority of the pilot participants found the IM concept, in addition to the proposed FIM crew procedures, to be acceptable and indicated that the ATD-1 procedures can be successfully executed in a near-term NextGen environment.

Murdock, Jennifer L.↗

Prediction Interval Development for Wind-Tunnel Balance Check-Loading

Results from the Facility Analysis Verification and Operational Reliability project revealed a critical gap in capability in ground-based aeronautics research applications. Without a standardized process for check-loading the wind-tunnel balance or the model system, the quality of the aerodynamic force data collected varied significantly between facilities. A prediction interval is required in order to confirm a check-loading. The prediction interval provides an expected upper and lower bound on balance load prediction at a given confidence level. A method has been developed which accounts for sources of variability due to calibration and check-load application. The prediction interval method of calculation and a case study demonstrating its use is provided. Validation of the methods is demonstrated for the case study based on the probability of capture of confirmation points.

Landman, Drew↗

Feasibility Criteria for Interval Management Operations as Part of Arrival Management Operations

Interval Management (IM) is a future airborne spacing concept that aims to provide more precise inter-aircraft spacing to yield throughput improvements and greater use of fuel efficient trajectories for arrival and approach operations. To participate in an IM operation, an aircraft must be equipped with avionics that provide speeds to achieve and maintain an assigned spacing interval relative to another aircraft. It is not expected that all aircraft will be equipped with the necessary avionics, but rather that IM fits into a larger arrival management concept developed to support the broader mixed-equipage environment. Arrival management concepts are comprised of three parts: a ground-based sequencing and scheduling function to develop an overall arrival strategy, ground-based tools to support the management of aircraft to that schedule, and the IM tools necessary for the IM operation (i.e., ground-based set-up, initiation, and monitoring, and the flight-deck tools to conduct the IM operation). The Federal Aviation Administration is deploying a near-term ground-automation system to support metering operations in the National Airspace System, which falls within the first two components of the arrival management concept. This paper develops a methodology for determining the required delivery precision at controlled meter points for aircraft that are being managed to a schedule and aircraft being managed to a relative spacing interval in order to achieve desired flow rates and adequate separation at the meter points.

Levitt, Ian M.↗