Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interval”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Confidence intervals for fitting of atomic models into low-resolution densities

This paper describes procedures for obtaining confidence intervals for coordinate locations resulting from the fitting of atomic models into low-resolution densities. The fitting of high-resolution structures into low-resolution densities obtained from techniques such as electron microscopy or small-angle X-ray scattering can yield powerful new insights. While several algorithms for achieving optimal fits have recently been developed, relatively little effort has been devoted to developing objective measures for judging the quality of the resulting fits, in particular with regard to the danger of overfitting. Here, a general method is presented for obtaining confidence intervals for atomic coordinates resulting from fitting of atomic resolution domain structures into low-resolution densities using well established statistical tools. It is demonstrated that the resulting confidence intervals are sufficiently accurate to allow meaningful statistical tests and to provide tools for detecting potential overfitting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-G-TeP1-02: Analytical Stopping Power and Range Parameterization for Therapeutic Energy Intervals

Purpose: To develop a simple, analytic parameterization of stopping power and range, which covers a wide energy interval and is applicable to many species of projectile ions and target materials, with less than 15% disagreement in linear stopping power and 1 mm in range. Methods: The new parameterization was required to be analytically integrable from stopping power to range, and continuous across the range interval of 1 µm to 50 cm. The model parameters were determined from stopping power and range data for hydrogen, carbon, iron, and uranium ions incident on water, carbon, aluminum, lead and copper. Stopping power and range data was taken from SRIM. A stochastic minimization algorithm was used to find model parameters, with 10 data points per energy decade. Additionally, fitting was performed with 2 and 26 data points per energy decade to test the model’s robustness to sparse Results: 6 free parameters were sufficient to cover the therapeutic energy range for each projectile ion species (e.g. 1 keV – 300 MeV for protons). The model agrees with stopping power and range data well, with less than 9% relative stopping power difference and 0.5 mm difference in range. As few as, 4 bins per decade were required to achieve comparable fitting results to the full data set. Conclusion: This study successfully demonstrated that a simple analytic function can be used to fit the entire energy interval of therapeutic ion beams of hydrogen and heavier elements. Advantages of this model were the small number (6) of free parameters, and that the model calculates both stopping power and range. Applications of this model include GPU-based dose calculation algorithms and Monte Carlo simulations, where available memory is limited. This work was supported in part by a research agreement between United States Naval Academy and Louisiana State University: Contract No N00189-13-P-0786. In addition, this work was accepted for presentation at the American Nuclear Society Annual Meeting 2016.

61 RADIATION PROTECTION AND DOSIMETRY↗

Confidence intervals with a priori parameter bounds

We review the methods of constructing confidence intervals that account for a priori information about one-sided constraints on the parameter being estimated. We show that the so-called method of sensitivity limit yields a correct solution of the problem. Derived are the solutions for the cases of a continuous distribution with non-negative estimated parameter and a discrete distribution, specifically a Poisson process with background. For both cases, the best upper limit is constructed that accounts for the a priori information. A table is provided with the confidence intervals for the parameter of Poisson distribution that correctly accounts for the information on the known value of the background along with the software for calculating the confidence intervals for any confidence levels and magnitudes of the background (the software is freely available for download via Internet).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectral observations of Venus in the frequency interval 18.5-24.0 GHz - 1964 and 1967-68.

During July 1964, Venus was observed with a tunable radiometer at eight frequencies in the interval 20.6-24.0 GHz and again at six frequencies in the interval 18.5-24.0 GHz during an eight-month period beginning approximately one month after the inferior conjunction of 1967. Microwave spectra for these frequency intervals were computed using the results from Mariner 5 and Veneras 4-7 and compared to these data. One block of data suggests a lower percentage of H2O than that reported by the Venera probes, while other blocks may be consistent with the probe data. These data therefore suggest that the distribution of water vapor down to atmospheric levels probed at these frequencies may vary with time or else the Venera probes may have detected localized enhancements in water vapor.

Jones, D. E.↗

Exact intervals and tests for median when one sample value possibly an outliner

Available are independent observations (continuous data) that are believed to be a random sample. Desired are distribution-free confidence intervals and significance tests for the population median. However, there is the possibility that either the smallest or the largest observation is an outlier. Then, use of a procedure for rejection of an outlying observation might seem appropriate. Such a procedure would consider that two alternative situations are possible and would select one of them. Either (1) the n observations are truly a random sample, or (2) an outlier exists and its removal leaves a random sample of size n-1. For either situation, confidence intervals and tests are desired for the median of the population yielding the random sample. Unfortunately, satisfactory rejection procedures of a distribution-free nature do not seem to be available. Moreover, all rejection procedures impose undesirable conditional effects on the observations, and also, can select the wrong one of the two above situations. It is found that two-sided intervals and tests based on two symmetrically located order statistics (not the largest and smallest) of the n observations have this property.

Keller, G. J.↗

A study to determine the usefulness of interval analysis in solving problems in celestial mechanics

This investigation was undertaken to determine the usefulness of interval analysis to numerical integration and matrix inversion techniques and to combine these results to determine the value of interval analysis in bounding computational errors in the two-body problem. Conclusions were that interval analysis may be worthwhile in certain small scale isolated problems, but its usefulness in any large scale problem is doubtful.

Walling, D.↗

Detectability of auditory signals presented without defined observation intervals

Ability to detect tones in noise was measured without defined observation intervals. Latency density functions were estimated for the first response following a signal and, separately, for the first response following randomly distributed instances of background noise. Detection performance was measured by the maximum separation between the cumulative latency density functions for signal-plus-noise and for noise alone. Values of the index of detectability, estimated by this procedure, were approximately those obtained with a 2-dB weaker signal and defined observation intervals. Simulation of defined- and non-defined-interval tasks with an energy detector showed that this device performs very similarly to the human listener in both cases.

Watson, C. S.↗

Optical timing receiver for the NASA laser ranging system. Part 2: High precision time interval digitizer

The development of a high precision time interval digitizer is described. The time digitizer is a 10 psec resolution stop watch covering a range of up to 340 msec. The measured time interval is determined as a separation between leading edges of a pair of pulses applied externally to the start input and the stop input of the digitizer. Employing an interpolation techniques and a 50 MHz high precision master oscillator, the equivalent of a 100 GHz clock frequency standard is achieved. Absolute accuracy and stability of the digitizer are determined by the external 50 MHz master oscillator, which serves as a standard time marker. The start and stop pulses are fast 1 nsec rise time signals, according to the Nuclear Instrument means of tunnel diode discriminators. Firing level of the discriminator define start and stop points between which the time interval is digitized.

Leskovar, B.↗

Department of Defense Precise Time and Time Interval program improvement plan

The United States Naval Observatory is responsible for ensuring uniformity in precise time and time interval operations including measurements, the establishment of overall DOD requirements for time and time interval, and the accomplishment of objectives requiring precise time and time interval with minimum cost. An overview of the objectives, the approach to the problem, the schedule, and a status report, including significant findings relative to organizational relationships, current directives, principal PTTI users, and future requirements as currently identified by the users are presented.

Bowser, J. R.↗

Nonlogarithmic magnetization relaxation at the initial time intervals and magnetic field dependence of the flux creep rate in Bi2Sr2Ca(sub I)Cu2Ox single crystals

At the initial time intervals, preceding the thermally activated flux creep regime, fast nonlogarithmic relaxation is found. The fully magnetic moment Pm(t) relaxation curve is shown. The magnetic measurements were made using SQUID-magnetometer. Two different relaxation regimes exist. The nonlogarithmic relaxation for the initial time intervals may be related to the viscous Abrikosov vortices flow with j is greater than j(sub c) for high enough temperature T and magnetic field induction B. This assumption correlates with Pm(t) measurements. The characteristic time t(sub O) separating two different relaxation regimes decreases as temperature and magnetic field are lowered. The logarithmic magnetization relaxation curves Pm(t) for fixed temperature and different external magnetic field inductions B are given. The relaxation rate dependence on magnetic field, R(B) = dPm(B, T sub O)/d(1nt) has a sharp maximum which is similar to that found for R(T) temperature dependences. The maximum shifts to lower fields as temperature goes up. The observed sharp maximum is related to a topological transition in shielding critical current distribution and, consequently, in Abrikosov vortices density. The nonlogarithmic magnetization relaxation for the initial time intervals is found. This fast relaxation has almost an exponentional character. The sharp relaxation rate R(B) maximum is observed. This maximum corresponds to a topological transition in Abrikosov vortices distribution.

Moshchalcov, V. V.↗

ISEE 3 observations during the CDAW 8 intervals - Case studies of the distant geomagnetic tail covering a wide range of geomagnetic activity

Observations made by the ISEE 3 spacecraft in the distant geomagnetic tail during the eight CDAW 8 intervals are discussed, along with their relation to concurrent geomagnetic activity. This extensive multiinstrument case study of distant tail data covers a wide range of geomagnetic conditions from extended intervals of magnetic quiet with isolated substorms to prolonged periods of intense disturbance. Plasmoids are observed in the distant tail following disturbance enhancements, the time of their appearance being generally consistent with disconnection from the near-earth region at the time of the enhancement. Their structure is entirely consistent with the neutral line model. However, not all enhancements in geomagnetic activity result in the observation of plasmoids. In particular, the CDAW 8 data suggest that, during extended intervals of strong activity, a continuous neutral line may reside in the near-earth tail and some disturbance enhancements may then relate to an increase in the reconnection rate at a preexisting neutral line, rather than to new neutral line and plasmoid formation.

Richardson, I. G.↗

Interval polynomial positivity

It is shown that a univariate interval polynomial is globally positive if and only if two extreme polynomials are globally positive. It is shown that the global positivity property of a bivariate interval polynomial is completely determined by four extreme bivariate polynomials. The cardinality of the determining set for k-variate interval polynomials is 2k. One of many possible generalizations, where vertex implication for global positivity holds, is made by considering the parameter space to be the set dual of a boxed domain.

Bose, N. K.↗

Boundary implications for frequency response of interval FIR and IIR filters

It is shown that vertex implication results in parameter space apply to interval trigonometric polynomials. Subsequently, it is shown that the frequency responses of both interval FIR and IIR filters are bounded by the frequency responses of certain extreme filters. The results apply directly in the evaluation of properties of designed filters, especially because it is more realistic to bound the filter coefficients from above and below instead of determining those with infinite precision because of finite arithmetic effects. Illustrative examples are provided to show how the extreme filters might be easily derived in any specific interval FIR or IIR filter design problem.

Bose, N. K.↗

Interval prediction in structural dynamic analysis

Methods for assessing the predictive accuracy of structural dynamic models are examined with attention given to the effects of modal mass, stiffness, and damping uncertainties. The methods are based on a nondeterministic analysis called 'interval prediction' in which interval variables are used to describe parameters and responses that are unknown. Statistical databases for generic modeling uncertainties are derived from experimental data and incorporated analytically to evaluate responses. Covariance matrices of modal mass, stiffness, and damping parameters are propagated numerically in models of large space structures by means of three methods. The test data tend to fall within the predicted intervals of uncertainty determined by the statistical databases. The present findings demonstrate the suitability of using data from previously analyzed and tested space structures for assessing the predictive accuracy of an analytical model.

Hasselman, Timothy K.↗

ISEE 3 plasmoid and TCR observations during an extended interval of substorm activity

On April 9-11, 1983, the ISEE 3 spacecraft was continuously located within the earth's magnetotail for more than 36 hours at downstream distances of X = -76 to -80 R(e). During this span of time, 12 major intervals of substorm activity were observed in the AL index with good ISEE 3 telemetry coverage for 11 of them. In addition, there were two small substorms outside of these intervals, both with complete observations in the distant tail. This unusual ISEE 3 data set provides a unique opportunity to test the predictions of the near-earth neutral line model. In particular, the hypothesis that energy stored in the tail lobes during the growth phase is later dissipated, in part, through the release of one or more plasmoids following expansion phase onset is examined. Clear growth phase enhancements in the lobe magnetic field intensity preceded the onsets of nine of the substorms. Plasmoids, or their lobe signatures, traveling compression regions (TCRs), were observed at ISEE 3 in association with all 11 of the major substorm intervals for which there were ISEE observations, as well as for the two small substorms. No plasmoids or TCRs were observed in the absence of substorm activity. If these ISEE 3 observations are representative, then the release of plasmoids down the tail may be a feature common to all substorms.

Slavin, J. A.↗

Stability margins for multilinear interval systems by way of phase conditions: A unified approach

A simple way of checking the stability with respect to an arbitrary stability region of a family of polynomials containing a vector of parameters varying within prescribed intervals is discussed. It is assumed that the parameters appear affine multilinearly in the characteristic polynomial coefficients. The condition proposed is simply to check the phase difference of the vertex polynomials. This test based on the mapping theorem significantly reduces computational complexity. Mathematical proofs are omitted. The results can be used to determine various stability margins of control systems containing interconnected interval subsystems. These include the gain, phase, time-delay, H(sup infinity), and nonlinear sector bounded stability margins of multilinear interval systems.

Keel, L. H.↗

Interval estimates for closure-phase and closure-amplitude imaging in radio astronomy

Interval estimates for closure-phase and closure-amplitude imaging that enable the reconstruction of a radioimage from results of approximate measurements are presented. If the intervals for the measured values are known, the precision of the result of the reconstruction cannot be solved by standard interval methods, because the phase value is based on a circle but not on a real line. If the phase theta (x bar) is measured with precision epsilon, so that the closure phase theta (x bar) + theta (y bar) - theta (x bar + y bar) is known with precision 3 epsilon, then from these measurements theta can be reconstructed with precision 6 epsilon. Similar estimates are given for closure amplitude.

Kreinovich, Vladik↗

Precision Interval Estimation of the Response Surface by Means of an Integrated Algorithm of Neural Network and Linear Regression

The integration of Radial Basis Function Networks and Back Propagation Neural Networks with the Multiple Linear Regression has been accomplished to map nonlinear response surfaces over a wide range of independent variables in the process of the Modem Design of Experiments. The integrated method is capable to estimate the precision intervals including confidence and predicted intervals. The power of the innovative method has been demonstrated by applying to a set of wind tunnel test data in construction of response surface and estimation of precision interval.

Lo, Ching F.↗