Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “internal dose coefficients”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

106 records · Page 6

Determination of the Absorbed Dose Rate to Water for the 18-mm Helmet of a Gamma Knife

Purpose: To measure the absorbed dose rate to water of {sup 60}Co gamma rays of a Gamma Knife Model C using water-filled phantoms (WFP). Methods and Materials: Spherical WFP with an equivalent water depth of 5, 7, 8, and 9 cm were constructed. The dose rates at the center of an 18-mm helmet were measured in an 8-cm WFP (WFP-3) and two plastic phantoms. Two independent measurement systems were used: one was calibrated to an air kerma (Set I) and the other was calibrated to the absorbed dose to water (Set II). The dose rates of WFP-3 and the plastic phantoms were converted to dose rates for an 8-cm water depth using the attenuation coefficient and the equivalent water depths. Results: The dose rate measured at the center of WFP-3 using Set II was 2.2% and 1.0% higher than dose rates measured at the center of the two plastic phantoms. The measured effective attenuation coefficient of Gamma Knife photon beam in WFPs was 0.0621 cm{sup -1}. After attenuation correction, the difference between the dose rate at an 8-cm water depth measured in WFP-3 and dose rates in the plastic phantoms was smaller than the uncertainty of the measurements. Conclusions: Systematic errors related to the characteristics of the phantom materials in the dose rate measurement of a Gamma Knife need to be corrected for. Correction of the dose rate using an equivalent water depth and attenuation provided results that were more consistent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-JeP4-07: Evaluation of Intrafraction Motion Using 3D Surface Guided Radiation Therapy in Lung SBRT

Purpose: Surface guided radiation therapy (SGRT) uses stereoscopic video images in combination with patterns projected onto the patient’s surface to dynamically capture and reconstruct a 3D surface map. In this work, we used a C-RAD Catalyst HD system (C-RAD) to evaluate intrafraction motion in the delivery of lung SBRT. Methods: The surface acquired from the 4DCT images from our preliminary cohort of eight lung cancer patients treated with SBRT were matched to the surface images acquired prior to each treatment. Additionally, a CBCT image set was acquired. A linear regression model was established between the external and internal motion of tumor during pretreatment and used to predict the CBCT deviation during treatment. The shifts determined from CBCT and the shifts from surface map imaging were compared and assessed using Bland-Altman method. For intrafraction motion, we assessed the percentage of mean errors that fell outside of the threshold of 2 mm, 3 mm, and 5 mm along the translational directions. The required PTV margin was quantified over the course of treatment. The correlation between intrafraction treatment time and mean error of 3D displacement was evaluated using the Pearson coefficient, r Results: A total of 7971 data points were analyzed. Deviations of 2mm, 3mm, and 5mm were observed less than 7%, 2 %, and 0 % of the time along the translational direction. CBCT and Catalyst showed close agreement during patient positioning. Furthermore, the calculated PTV margins were less than our clinical tolerance of 5 mm. Using the Pearson coefficient r,the mean error of 3D displacement showed significant correlation with treatment time (r=0.69, p= 0.000002). Conclusion: SGRT can be used to ensure accurate patient positioning during treatment without an additional delivery of dose to the patient. This study shows that importance of treatment time as a consideration during the treatment planning process.

60 APPLIED LIFE SCIENCES↗

Million Worker Study

Radiation health issues have been an important aspect of DOE's Worker Safety and Health programs. The goal is to ensure that workers are adequately protected from the various radiological hazards associated with DOE sites and operations. Since the early 1940’s DOE has supported the conduct of epidemiologic studies of practically every DOE (AEC) facility and collected these data, now managed by the Oak Ridge Associated Universities (ORAU), in remarkable detail. In the early 2000s, the Office of Health, Safety and Security authorized access to specific DOE worker datasets. Shortly thereafter, the DOE Office of Science provided funds for a pilot study that confirmed the feasibility of the Million Worker Study (MWS), and then additional resources were provided (with other agencies) to extend the follow-up of many populations, not just DOE workers, but also atomic veterans, industrial radiographers, nuclear power plant workers and medical radiation workers (the Million Persons Study (MPS)). This proposal was a continuation of support provided by DOE, specifically to extend the follow-up of the worker populations at the Mallinckrodt Chemical Works (MCW) and Los Alamos National Laboratory (LANL). The work addresses DOE’s interest in clarifying the health risks of their workers as well as contributing knowledge on radiation risks that is relevant today with regard to compensation schemes. The findings are also important for the US public in light of the increased population exposure to medical imaging, environmental circumstances such as hydraulic fracturing, increased exposures during high altitude flights, and with regard to nuclear accidents such as Fukushima and possible terrorist events. Furthermore, it is important to consider reducing the uncertainty in current risk estimates by developing risk coefficients based on healthy American workers who are more representative of U.S. workers and the general public than 1945 Japanese survivors of the atomic bombs living in a war-torn country which experienced deprivation, malnourishment, and increased rates of infections and other diseases. But more importantly, it is important to learn whether radiation exposures received gradually over time (e.g., years) are more or less effective in causing health effects, cancer in particular, than if the radiation dose is received all at once in a fraction of a second as experienced by the Japanese atomic bomb survivors. Finally, the ability to evaluate and combine large populations with intakes of radionuclides such as uranium, radium, plutonium, americium and polonium will provide new quantitative knowledge on human health effects that hitherto has not been possible. This cost-efficient study has built on the investments made and foundations laid by investigators and government agencies, including DOE, over the past 30-40 years, which have established early worker cohorts that can now provide answers to questions on the lifetime human health risks associated with low-level radiation exposures. Collaborating institutions included: International Epidemiology Institute, Oak Ridge Associated Universities, Oak Ridge National Laboratory, Los Alamos National Laboratory, Landauer, Inc., and Vanderbilt University. Follow-up of these two populations and the integration of them with the many other cohorts (now a total of 31) in the MPS continues under a separate DOE grant (DE-AU0000046).

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison between DVH-based doses and ICRU point-based doses to the rectum and the bladder using CT-based high-dose rate brachytherapy to the cervix

Traditionally, doses to the bladder and the rectum were quantified using the bladder and rectal reference points defined by the International Commission on Radiation Units and Measurements (ICRU) in Report No. 38. In this study, we compared the 0.1-, 1.0-, 2.0-cc doses to the bladder and the rectum with the corresponding ICRU point doses using computed tomography (CT)-based planning in the intracavitary brachytherapy of carcinoma of the cervix. CT datasets of 136 consecutive intracavitary brachytherapy insertions between January and May 2015 were analyzed. The bladder and the rectum were contoured on consecutive CT slices as per Groupe Europeen de Curietherapie and the European Socie Ty for Radiotherapy and Oncology recommendations. Dose volume histograms were generated and doses of 0.1, 1.0, and 2.0 cc to the bladder and the rectum were recorded. ICRU bladder and rectal points were identified in the treatment plan. Mean doses of 0.1, 1.0, and 2.0 cc to the bladder was found to be 2.02, 1.57, and 1.35 times the ICRU point dose, respectively. The maximum dose received by the bladder was found to be 5.83 times the average ICRU point dose. Mean doses of 0.1, 1.0, and 2.0 cc to the rectum were found to be 1.12, 0.90, and 0.78 times the ICRU rectal point dose, respectively. The maximum dose received by the rectum was 4.79 times the average ICRU point dose. The Pearson correlation coefficient value (r) was found to be 0.639 for D2cc and ICRU bladder point values. The Pearson correlation coefficient value was found to be 0.752 for D2cc and ICRU rectal point values. Our results show that the ICRU bladder points underestimated the dose to the bladder, which is in agreement with other studies. ICRU rectal point doses were higher than the corresponding D2cc doses. However, there was a good correlation between D2cc and ICRU point doses for both the bladder and the rectum.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear data needs for advanced reactor systems. A NEA nuclear science committee initiative.

The Working Party on Evaluation Cooperation (WPEC) of the OECD Nuclear Energy Agency Nuclear Science Committee has established an International Subgroup to perform an activity in order to develop a systematic approach to define data needs for Gen-IV and, in general, for advanced reactor systems. A methodology, based on sensitivity analysis has been agreed and representative core configurations for Sodium, Gas and Lead cooled Fast Reactors (SFR, GFR, LFR) have been defined as well as a high burn-up VHTR and a high burn-up PWR. In the case of SFRs, both a TRU burner (called in fact SFR) and a core configuration with homogeneous recycling of not separated TRU (called EFR) have been considered. The methodology, the systems considered and the sensitivity approach are consistent with the work reported in ref. [1]. For the present study, the approach has been extended to the ABTR Na-cooled core, recently studied within the GNEP initiative [2]. Sensitivity coefficients (in a 15 energy group structure) have been calculated at ANL with the ERANOS code system [3] for all reactors and for the parameters most sensitive to nuclear data uncertainties: Multiplication factor, Power peak, Burn-up {Delta}k/k, Coolant void reactivity coefficient, Doppler reactivity coefficient, Nuclide density at end of cycle (transmutation potential), Neutron source at fuel fabrication, Dose in a repository.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of SIAL{sup R} Solidification Technology for Processing of Problematic Waste Streams - 18267

SIAL{sup R} is a proven, safe, cost-effective and licensed waste solidification technology that has been used successfully for 20 years in Slovakia and the Czech Republic for processing of various problematic radioactive waste streams. This abstract presents and summarises the most interesting performance records of the SIAL{sup R} geopolymer solidification technology, the applied mobile devices as well as the characteristics of final products. Radioactive waste solidification into matrix SIAL{sup R} is based on polycondensation of inorganic aluminosilicate components with chemical composition similar to average cement. The main components of matrix SIAL{sup R} are natural inorganic raw materials containing SiO{sub 2}, Al{sub 2}O{sub 3}, CaO, MgO, Na{sub 2}O, K{sub 2}O, Fe{sub 2}O{sub 3}, and TiO{sub 2}. The treatment/solidification process is modified for individual radioactive streams with different compositions. To determine the most appropriate composition, the SIAL{sup R} application technology is laboratory tested on real samples of each individual waste stream identified for solidification. Then an appropriate mixture of aluminosilicate composition and other inorganic compounds is defined for a given solidification application. When determining the most appropriate mixture, other requirements are taken into consideration: maximum dose rate on the drum with solidified product, mass, volume, alpha radionuclide content in the final product, need for a waste's dewatering before solidification, dry matter content in the solidification product as well as other specific waste acceptance criteria (i.e., compressive strength, leachability, diffusion coefficients, radiation stability, biodegradability of matrix, distribution and partition coefficients, influence of frost and water presence to the product stability including long term physical stability in water, dustiness, flammability, time dependence of compression strength and water reduction, product homogeneity and also radiolytic G-value for hydrogen release, GH{sub 2}). The Amec Foster Wheeler baseline approach to implementing the SIAL{sup R} waste treatment process is structured on three steps - waste characterization, waste retrieval and pre-treatment and at last the solidification of pre-treated waste itself. The equipment used for the solidification process is relatively small, lightweight and designed for the specific application on site, directly 'in situ' or local to the tanks storing the sludge's/resins/other waste streams. This mitigates the problems normally experienced by transferring sticky, tight waste through long pipes. The equipment is normally 'tailor-made' to take into account the real space conditions and other existing facility requirements. At Bohunice and Dukovany sites, the facilities for encapsulation were designed to occupy existing areas of the plants in close proximity to the tanks where the waste was being stored. This allowed for the removal of the waste using Remote Operated Vehicles and for the waste to be immediately treated on site without the need for transportation thus saving both, time and resource. To date, SIAL{sup R} has been used successfully to immobilize approximately 2 x 10{sup 6} kg of waste which includes sludge, resin, crystalline borates and contaminated organic waste from Bohunice and Mochovce, Slovakia and approximately 300 m{sup 3} of spent ion exchange resins and sludge from tanks on site at the Dukovany NPP (Nuclear Power Plant) in the Czech Republic. The technology now has a track record of over 20 years which includes on-going research and development. The International missions WANO (the World Association of Nuclear Operators) and OSART (the Operational Safety Review Team) evaluated the SIAL{sup R} matrix technology at Dukovany NPP as an example of good practice. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of Scopolamine in Human Saliva Using Solid Phase Extraction and LC/MS/MS

Purpose: Scopolamine is the preferred treatment for motion sickness during space flight because of its quick onset of action, short half-life and favorable side-effect profile. The dose administered depends on the mode of administration and usually ranges between 0.1 and 0.8 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids by using conventional HPLC methods. To measure scopolamine in saliva and thereby to evaluate the pharmacokinetics of scopolamine, we developed an LC/MS/MS method using off-line solid phase extraction. Method: Samples (0.5mL) were loaded onto Waters Oasis HLB co-polymer cartridges (10 mg, 1 mL) and eluted with 0.5 mL methanol without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 4 minutes. The mobile phase for separation was 90:10 (v/v) methanol: ammonium acetate (2 mM) in water, pH 5.0 +/- 0.1. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 yields 138.1 and internal standard (IS) hyoscyamine m/z = 290.2 yields 124.1. Results: The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at 1.7 and 3.2 min respectively. The linear range is 50-5000 pg/mL for scopolamine in saliva with correlation coefficients > 0.99 with a CV < 0.5 %. The intra-day and inter-day CVs are < 15 % for quality control samples with concentrations of 75, 300, 750 and 3000 pg/mL of scopolamine in human saliva. Conclusion: Solid phase extraction allows more rapid sample preparation and greater precision than liquid extraction. Furthermore, we increased the sensitivity and specificity by adjusting the LC mobile phase and using an MS/MS detector.

Wang, Zuwei↗

SU-F-BRF-01: A GPU Framework for Developing Interactive High-Resolution Patient-Specific Biomechanical Models

Purpose: To develop a GPU-based framework that can generate highresolution and patient-specific biomechanical models from a given simulation CT and contoured structures, optimized to run at interactive speeds, for addressing adaptive radiotherapy objectives. Method: A Massspring-damping (MSD) model was generated from a given simulation CT. The model's mass elements were generated for every voxel of anatomy, and positioned in a deformation space in the GPU memory. MSD connections were established between neighboring mass elements in a dense distribution. Contoured internal structures allowed control over elastic material properties of different tissues. Once the model was initialized in GPU memory, skeletal anatomy was actuated using rigid-body transformations, while soft tissues were governed by elastic corrective forces and constraints, which included tensile forces, shear forces, and spring damping forces. The model was validated by applying a known load to a soft tissue block and comparing the observed deformation to ground truth calculations from established elastic mechanics. Results: Our analyses showed that both local and global load experiments yielded results with a correlation coefficient R{sup 2} > 0.98 compared to ground truth. Models were generated for several anatomical regions. Head and neck models accurately simulated posture changes by rotating the skeletal anatomy in three dimensions. Pelvic models were developed for realistic deformations for changes in bladder volume. Thoracic models demonstrated breast deformation due to gravity when changing treatment position from supine to prone. The GPU framework performed at greater than 30 iterations per second for over 1 million mass elements with up to 26 MSD connections each. Conclusions: Realistic simulations of site-specific, complex posture and physiological changes were simulated at interactive speeds using patient data. Incorporating such a model with live patient tracking would facilitate real time assessment of variations of the actual anatomy and delivered dose for adaptive intervention and re-planning.

60 APPLIED LIFE SCIENCES↗

A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.

Wang, Zuwei↗

Statistical Uncertainty of Inhalation Dose Coefficients: Impact of Particle Deposition in ICRP 66 Human Respiratory Tract Model

Inhaled radioactive materials can pose a long-term health concern, as the material can be incorporated into the body’s metabolic pathways and remain in organs and tissues for extended durations. During the retention period, the radioactive material may localize in a source organ and irradiate adjacent target organs and tissues. Distribution of these materials changes over time, requiring biokinetic modeling to evaluate their movement through various tissues and organs. The evolving distribution depends on multiple inputs characterizing the inhaled material, such as particle size and size distribution, particle density, aspect ratio, specific radionuclide, the chemical form, and solubility. In addition, biological parameters such as breathing rate, breathing type (nasal or nasal/oral), respiratory system morphometry, tidal volume, functional residual capacity, and anatomical dead space all influence material transport. These aerosol properties and physiological characteristics of the respiratory tract jointly define a range of initial conditions that influence the time-dependent distribution of radioactive material. To evaluate both uncertainty in the initial conditions of inhalation exposure and the final output (committed effective dose) from biokinetic models, a Python-based software tool, Radiological Exposure Dose Calculator (REDCAL), was developed to propagate uncertainty within the human respiratory tract model. Focusing on deposition fraction uncertainty, the primary objective was to characterize the initial activity distribution across respiratory regions as a function of anticipated particle sizes and distributions. The impact of the deposition fraction uncertainty was propagated to committed effective dose coefficients for selected radionuclides in a companion publication. For each particle size, a lognormal distribution, characterized by its geometric mean as defined within ICRP Publication 66, serves as the basis for introducing uncertainty into the physical processes governing deposition in various lung regions. Finally, this study addresses the deposition process and examines how uncertainty in deposition mechanisms affects activity distribution in the airways, ultimately presenting the expected range and standard deviation of deposited activity as a function of particle size.

International Commission on Radiological Protectio↗

Best practices for predictions of radionuclide activity concentrations and total absorbed dose rates to freshwater organisms exposed to uranium mining/milling

Predictions of radionuclide dose rates to freshwater organisms can be used to evaluate the radiological environmental impacts of releases from uranium mining and milling projects. These predictions help inform decisions on the implementation of mitigation measures. The objective of this study was to identify how dose rate modelling could be improved to reduce uncertainty in predictions to non-human biota. For this purpose, we modelled the activity concentrations of 210 Pb, 210 Po, 226 Ra, 230 Th, and 238 U downstream of uranium mines and mills in northern Saskatchewan, Canada, together with associated weighted absorbed dose rates for a freshwater food chain using measured activity concentrations in water and sediments. Differences in predictions of radionuclide activity concentrations occurred mainly from the different default partition coefficient and concentration ratio values from one model to another and including all or only some 238 U decay daughters in the dose rate assessments. Consequently, we recommend a standardized best-practice approach to calculate weighted absorbed dose rates to freshwater biota whether a facility is at the planning, operating or decommissioned stage. At the initial planning stage, the best-practice approach recommend using conservative site-specific baseline activity concentrations in water, sediments and organisms and predict conservative incremental activity concentrations in these media by selecting concentration ratios based on species similarity and similar water quality conditions to reduce the uncertainty in dose rate calculations. At the operating and decommissioned stages, the best-practice approach recommends relying on measured activity concentrations in water, sediment, fish tissue and wholebody of small organisms to further reduce uncertainty in dose rate estimates. This approach would allow for more realistic but still conservative dose assessments when evaluating impacts from uranium mining projects and making decision on adequate controls of releases.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

SU-F-303-12: Implementation of MR-Only Simulation for Brain Cancer: A Virtual Clinical Trial

Purpose: To perform a retrospective virtual clinical trial using an MR-only workflow for a variety of brain cancer cases by incorporating novel imaging sequences, tissue segmentation using phase images, and an innovative synthetic CT (synCT) solution. Methods: Ten patients (16 lesions) were evaluated using a 1.0T MR-SIM including UTE-DIXON imaging (TE = 0.144/3.4/6.9ms). Bone-enhanced images were generated from DIXON-water/fat and inverted UTE. Automated air segmentation was performed using unwrapped UTE phase maps. Segmentation accuracy was assessed by calculating intersection and Dice similarity coefficients (DSC) using CT-SIM as ground truth. SynCTs were generated using voxel-based weighted summation incorporating T2, FLAIR, UTE1, and bone-enhanced images. Mean absolute error (MAE) characterized HU differences between synCT and CT-SIM. Dose was recalculated on synCTs; differences were quantified using planar gamma analysis (2%/2 mm dose difference/distance to agreement) at isocenter. Digitally reconstructed radiographs (DRRs) were compared. Results: On average, air maps intersected 80.8 ±5.5% (range: 71.8–88.8%) between MR-SIM and CT-SIM yielding DSCs of 0.78 ± 0.04 (range: 0.70–0.83). Whole-brain MAE between synCT and CT-SIM was 160.7±8.8 HU, with the largest uncertainty arising from bone (MAE = 423.3±33.2 HU). Gamma analysis revealed pass rates of 99.4 ± 0.04% between synCT and CT-SIM for the cohort. Dose volume histogram analysis revealed that synCT tended to yield slightly higher doses. Organs at risk such as the chiasm and optic nerves were most sensitive due to their proximities to air/bone interfaces. DRRs generated via synCT and CT-SIM were within clinical tolerances. Conclusion: Our approach for MR-only simulation for brain cancer treatment planning yielded clinically acceptable results relative to the CT-based benchmark. While slight dose differences were observed, reoptimization of treatment plans and improved image registration can address this limitation. Future work will incorporate automated registration between setup images (cone-beam CT and kilovoltage images) for synCT and CT-SIM. Submitting institution holds research agreements with Philips HealthCare, Best, Netherlands and Varian Medical Systems, Palo Alto, CA. Research partially sponsored via an Internal Mentored Research Grant.

60 APPLIED LIFE SCIENCES↗

Development of an Assessment Method for Radiation Exposure from NORM in Construction Materials - 19032

Once radiological impact is usually considered to be related to nuclear energy accidents and atomic bombs, most of the research on radiation protection has been focused on artificial radionuclides and radioactive waste. Less attention had been given to radiation exposure due to the presence of naturally occurring radioactive materials in raw materials usually considered as not radioactive and used in manufacturing of many building materials. At national level, radiological data from building materials is not available as the control of building materials regarding the content of naturally occurring radionuclides is addressed for the first time in the EU Directive 2013/59/EURATOM. At international level the research developed is largely incomplete: data on the activity concentration measurements of Ra-226, Th-232 and K-40 in building materials used in the construction industry in the EU is non-statistically representative. The data collected are not enough to have an idea of the European situation, but they confirm high concentration of Ra-226, Th-232 and K-40, in some cases. Moreover, most of the research studies carried out in the EU are based on the assessment of the activity concentration index, which was derived for practical monitoring purposes to identify whether a dose criterion is met; to be used only as a screening tool for identifying materials which might be of concern. The dose criterion considers only effective dose due to γ-radiation, but population at home is also exposed to Rn-222 (and Rn-220) from soil, water and building material itself, sometimes to β radiation from superficial materials, and even to Cs-137 from some types of wood. The indoors exposure can be actually much higher than the value assessed with the dose criterion method. Also, in most cases toxic and radioactive components are inseparably. Therefore, all technical questions related to the toxic part of these materials should be addressed: an integrated approach is needed to assess the impacts of using these materials (new materials, recyclates and by-products). Until recently, radiation from natural sources seemed both unremarkable and unalterable - a background phenomenon. It is now known that doses from natural sources and in particular, decay products of radon can be remarkably high within houses in some areas. Therefore, concerning exposure to natural radiation sources, special provisions have been laid down in the EU Directive 1996/28 EURATOM. Still, the radiological evaluation of building materials was not mandatory in this Directive. The most recent EU Directive 2013/59/EURATOM brings some changes concerning the exposure to natural occurring radioactive materials but the previous screening method was kept. An effective dose of 1 mSv/year was set, as a basis for the exposure to radionuclides of natural origin (except for radon). This work seeks to develop an integrated radiological and chemical-mineralogical assessment methodology for realistic exposure scenarios concerning different types of raw materials, by-products and recyclates and used as building materials. The methodology includes the characterization of selected materials accounting for radiological exposure - calculation of effective dose; toxicity assessment - determination of chemical composition and leaching tests, study of changes in the microstructure and consequently in the radon emanation coefficient. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dispersion of Radionuclides and Exposure Assessment in Urban Environments: A Joint CEA and LLNL Report

In the interest of promoting the international exchange of technical expertise, the US Department of Energy’s Office of Emergency Operations (NA-40) and the French Commissariat à l'Energie Atomique et aux énergies alternatives (CEA) requested that the National Atmospheric Release Advisory Center (NARAC) of Lawrence Livermore National Laboratory (LLNL) in Livermore, California host a joint table top exercise with experts in emergency management and atmospheric transport modeling. In this table top exercise, LLNL and CEA compared each other’s flow and dispersion models. The goal of the comparison is to facilitate the exchange of knowledge, capabilities, and practices, and to demonstrate the utility of modeling dispersal at different levels of computational fidelity. Two modeling approaches were examined, a regional scale modeling approach, appropriate for simple terrain and/or very large releases, and an urban scale modeling approach, appropriate for small releases in a city environment. This report is a summary of LLNL and CEA modeling efforts from this exercise. Two different types of LLNL and CEA models were employed in the analysis: urban-scale models (Aeolus CFD at LLNL/NARAC and Parallel- Micro-SWIFT-SPRAY, PMSS, at CEA) for analysis of a 5,000 Ci radiological release and Lagrangian Particle Dispersion Models (LODI at LLNL/NARAC and PSPRAY at CEA) for analysis of a much larger (500,000 Ci) regional radiological release. Two densely-populated urban locations were chosen: Chicago with its high-rise skyline and gridded street network and Paris with its more consistent, lower building height and complex unaligned street network. Each location was considered under early summer daytime and nighttime conditions. Different levels of fidelity were chosen for each scale: (1) lower fidelity mass-consistent diagnostic, intermediate fidelity Navier-Stokes RANS models, and higher fidelity Navier-Stokes LES for urban-scale analysis, and (2) lower-fidelity single-profile meteorology versus higher-fidelity three-dimensional gridded weather forecast for regional-scale analysis. Tradeoffs between computation time and the fidelity of the results are discussed for both scales. LES, for example, requires nearly 100 times more processor time than the mass-consistent diagnostic model or the RANS model, and seems better able to capture flow entrainment behind tall buildings. As anticipated, results obtained by LLNL and CEA at regional scale around Chicago and Paris look very similar in terms of both atmospheric dispersion of the radiological release and total effective dose. Both LLNL and CEA used the same meteorological data, Lagrangian particle dispersion models, and the same dose coefficients. LLNL and CEA urban-scale modeling results show consistent phenomenological behavior and predict similar impacted areas even though the detailed 3D flow patterns differ, particularly for the Chicago cases where differences in vertical entrainment behind tall buildings are particularly notable. Although RANS and LES (LLNL) models incorporate more detailed physics than do mass-consistent diagnostic flow models (CEA), it is not possible to reach definite conclusions about the prediction fidelity of the various models as experimental measurements were not available for comparison. Stronger conclusions about the relative performances of the models involved and evaluation of the tradeoffs involved in model simplification could be made with a systematic benchmarking of urban-scale modeling. This could be the purpose of a future US / French collaborative exercise.

54 ENVIRONMENTAL SCIENCES↗

Radiological Performance Modeling: Platform Comparison

Zapadnoe Uranium Mill Tailings Site, Pridneprovsky Chemical Plant Ukraine: Two exposure scenarios were utilized to develop performance assessment models in GoldSim and NORMALYSA. The first scenario is an onsite worker exposed to radioactivity through external ground irradiation as well as radon and radioactive dust inhalation. The second being an offsite Resident 300 years after institutional control exposed through the ingestion of garden vegetables irrigated by contaminated ground water, ingestion of fish from Konoplyanka River, and agricultural activities in contaminated garden. NORMALYSA utilizes a modular interface to connect extensive pre-created modules to develop contaminant transport and risk assessment models for safety assessments and performance assessments at NORM and legacy sites. Developed by Facilia AB, the program was tested with the creation of the Zapadnoe model under the International Atomic Energy Agency MODARIA Il Working Group 1 (WG1). Default values are provided for input parameters where site specific data and distributions lack. Probabilistic simulations and inputs are limited to parameters with assigned Gaussian probability functions. Similar results for transient worker inhalation dose were found in comparison with the Zapadnoe GoldSim model. However, the NORMALYSA model has results larger by an order of magnitude for external radiation in the transient worker and for aquatic food ingestion, inhalation, and garden food ingestion to the resident. Performance Assessment Modeling: Radiological performance models promote good management and support in remediation and environmental decision making by optimizing radioactive waste disposal site performance. a performance assessment model of the Zapadnoe uranium mill tailings site and a model for calculating authorized limits at Los Alamos National Laboratory are created to demonstrate and highlight the respective capabilities of three modeling platforms: GoldSim, NORMALYSA, and RESRAD-Onsite. GoldSim is a general-purpose modeling platform with the ability to simulate site-specific FT radionuclide transport and risk assessment using a graphical interface to create and link elements that act as indivisible building blocks of the model. The Zapadnoe performance assessment model created in GoldSim is composed of input parameters collected from site specific parameters from WG1 as well as standard assumptions seen in the Generic PA Model from Neptune and Company. The multivariate Zapadnoe simulation contains both deterministic and probabilistic simulation capabilities with the ability to quantitatively represent the uncertainty and associated risks of the site via the Monte Carlo simulation method. Model parameters, documentation, and assumptions are built directly into the model creating a transparent, reproducible, and more purposeful site specific model. To demonstrate this, an ingestion of water pathway was included in addition to the exposure pathways included in the NORMALYSA model. GoldSim offers a wide variety of probability distributions to choose from as well as many tools to visualize the uncertainty of the models and explore which pathways and radionuclides dominate dose. In contrast to the NORMALYSA model, the GoldSim model uses dynamic simulation to calculate tritium concentrations. Authorized limits support the evaluation of radiological health effects from radionuclides present in bulk contaminated soil in order to assist in the process of clearing land for release under different uses. Calculations of authorized limits in RESRAD-Onsite and GoldSim models support the evaluation for 15 radionuclides using a residential exposure scenario, indoor and outdoor inhalation of dust and vapor phase radionuclides (tritium), incidental soil ingestion, and ingestion grown fruits and Vegetables. RESRAD-Onsite, developed by Argonne National Laboratory is a dedicated computer code for calculating radiation doses and cancer risks to an individual located on top of radioactively contaminated soils. It can also be used to provide guidelines for deriving radionuclide soil levels corresponding to a specific dose criterion. The menu driven user interface facilitates selection of radionuclides and soil concentrations, as well as defines parameter values related to materials, environmental factors, and exposure pathways. The program contains radionuclide-specific data such as dose conversion factors and risk coefficients, as well as soil-water partition coefficients and transfer factors for biotic media. The GoldSim model successfully emulates the RESRAD-Onsite code using identical radiological decay and ingrowth factors, radiation dose conversion factors, and other input parameters. DE EEDE ETS Each model supports dynamic modeling of radionuclide ingrowth and decay over time, and integrate this capability with the transport of radionuclides in the environment via processes such as advection and/or diffusion in fluids, or within porous solid media, The applicability of each program is heavily dependent on project context. In the context of developing Authorized Limits, RESRAD-Onsite may be a more desirable option as it was developed for this particular application. For simple disposal or legacy sites or sites that do not need site-specific model structure, NORMALYSA may be a desirable modeling platform, GoldSim can be used to model any problem for which RESRAD or NORMALYSA is applicable, but its strength lies in its flexibility, analytical, and probabilistic capabilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A New Look at Historic CRAC 'Divergence' Experiments - Implications for a CAAS Minimum Accident of Concern

This paper examines power history parameters and results based on historic fissile solution criticality 'divergence' experiments (referenced here as Divergence Experiments) from the 1960's-70's' Consequences Radiologiques d'un Accident de Criticite' (CRAC) campaign. The results from specific Divergence Experiments have implications for an ANSI/ANS-8.3 (1997) Criticality Accident Alarm System (CAAS) Minimum Accident of Concern (MAC). Specifically, this paper examines select CRAC Divergence Experiments in conjunction with 'qualifying reactivity additions' for a MAC defined by an absolute time constraint. A previous paper presented at the 2011 International Conference on Nuclear Criticality (ICNC 2011) illustrated the differences in 'qualifying reactivity additions' above delayed critical (and below prompt) for a variety of MAC constructs. That paper was the first to examine delayed critical kinetics in greater detail over a range of process and MAC considerations. The ICNC2011 work did not consider an absolute MAC time constraint from the excursion onset and assumed an initial excursion power. That study evaluated MAC constructs based on 'relative time differences' between reaching a specific fission rate and total fissions. The work presented here thus picks up where the ICNC2011 study left off. The primary focus of this work provides simulated power histories for specific Divergence Experiments that served as a basis for justifying a MAC noted in ANS-8.3 Appendix A. This paper documents computational modeling and dynamic multiphysics simulation with known Divergence Experiment parameters for reactivity additions at, below, and above the reported terminal reactivity. The initial step considers replicating what could be a reasonable power history for the terminal reactivity addition to the extent the same peak power and total fissions are obtained over the total time considered. Power histories for all other reactivity additions are simulated by varying the input reactivity and solution heights for the same model. A relationship is obtained between reactivity addition and the time to reach specific MAC power and fission levels within a given time constraint (e.g. 60 s). The 'qualifying reactivity addition' is determined for the total MAC fissions within that time. This value is then compared to the historic terminal value (e.g. $0.33) or any other values (e.g. 'excess reactivity of only a few cents') noted in ANS-8.3 Appendix A. In general, calculated MAC power levels have ranged from 1.8 kW to 173 kW depending on material type and form, H/U, enrichment, critical volume, and dose response function. A minimum accident consideration noted a SHEBA experiment with an excess reactivity 7 cents above delayed critical (TD ∼110 s). This excursion provided an additional 10{sup 15} fissions after an undetermined buildup time resulting in a 'few times 10{sup 15} fissions'. ICNC 2011 LEU solutions calculations show 0.2 Gy in air corresponds to 1.4 x10{sup 16} fissions. Thus, while historically, 0.2 Gy has been loosely associated with 'several times 10{sup 15} fissions', in reality, the actual total fissions could be an order of magnitude larger, and the power associated with 0.2 Gy/min (7.5 kW) larger as well. The reactivity addition required to obtain the actual 0.2 Gy total fissions over 60 s could be much larger than considered. Another reason the qualifying reactivity level could be larger than previously noted, involves temperature reactivity feedback. Compensated reactivity results in a departure from a pure exponential power rise, increasing the doubling time (TD) as the excursion approaches peak power. Uncompensated reactivity additions and constant TD have been traditionally assumed for a pure exponential power rise through the kW range to determine either total MAC fissions, power, or arrival time to these values.

42 ENGINEERING↗