Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometry observations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Effects of crystallographic orientation on calcite dissolution under alkaline conditions

Here, this study investigates the dissolution of calcite’s (104) and (100) surfaces under alkaline conditions (pH 8.8–13.1) using vertical scanning interferometry under flow-through conditions. The dissolution rate of (100) surfaces decreases with increasing pH. For example, the dissolution rate at pH 8.8 is more than 20 times higher than that at pH 13.1. In contrast, the dissolution rate of (104) surfaces is far less sensitive to pH. We explain these observations as being on account of the preferential adsorption of [OH – ] on (100) surfaces, inhibiting their dissolution. Particularly, this is because Ca-surface sites on (100) surfaces are less coordinated and have a stronger tendency for [OH – ] adsorption. As a result, (100) surfaces dissolve nearly twice as fast as (104) surfaces at pH 8.8, whereas (104) surfaces dissolved ~4.5 times faster than (100) surfaces at pH 13.1; indicating an inversion in dissolution behavior. The dissolution rate of (104) surfaces at pH 13.1 is 60 % of the rate at pH 10–12 because of the formation of slow dissolving microfacets of other orientations. The rhombohedral dissolution etch-pits formed on (104) surfaces, at lower pH’s, disappeared upon exposure to solutions with pH > 12 and were replaced by protrusions. The addition of up to 4m (molality) NaCl enhances the dissolution of (104) surfaces at pH 8.8–13.1 and (100) surfaces at pH 8.8–11.0, and inhibited the dissolution of (100) surfaces at pH = 12.0–13.1. In addition, the competing adsorption between OH – and CO 3 2– species mitigates the inhibition effects of CO 3 2– on both surfaces at pH 13.1 compared to pH 11, and the dissolution of (100) surfaces is far less affected by CO 3 2– than (104) surfaces. These results provide new insights into the rates and mechanisms of how crystallographic orientations affect calcite’s dissolution at alkaline pH conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Directionally asymmetric nonlinear optics in ferrorotational MnTiO 3

Ferrorotationally ordered materials possess a planar chiral lattice of electric dipoles that are a promising platform for exhibiting directionally asymmetric response functions. A key characteristic of such order is that enantiomorph conversion occurs when the solid is flipped by 180° about an in-plane axis. Using second-harmonic interferometry, we show here that when circularly polarized light is incident on MnTiO 3 , the generated harmonic intensity depends on whether the incident light is parallel or antiparallel to the ferrorotational axis. For a particular photon helicity, constructive interference occurs in one direction while destructive interference occurs in the other. Here, our observations represent a fundamentally new optical effect, associated with circularly polarized light in ferrorotational solids, that is distinct from conventional optical activity observed in three-dimensional chiral and Faraday media.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-resolution hypernuclear decay pion spectroscopy at MAMI and future

Hypernuclear decay pion spectroscopy was established in 2012 at MAMI as a mass spectroscopy method for light hypernuclei. A monochromatic pion peak from $^4_Λ$H was successfully observed, and the Λ binding energy was determined to be B Λ = 2.157±0.005(stat.)±0.077(syst.) MeV in the 2014 run. In 2022, an upgrade experiment for $^3_Λ$H spectroscopy was conducted using a newly developed Li target. The absolute electron beam energy will be measured by the synchrotron radiation interferometry, which will be applied with the spectrometer calibration to improve the systematic error. The decay pion spectroscopy is planned to be performed at JLab Hall-C, which would significantly increase the statistics thanks to the higher energy beam, the better K + identification, and the faster data acquisition system. This experiment has been submitted as a Letter of Intent in JLab PAC51. The upgraded decay pion spectroscopy method is expected to provide new, accurate hypernuclear data, which will contribute to the advancement of our understanding of hypernuclear physics

47 OTHER INSTRUMENTATION↗

Hugoniot states and optical response of soda lime glass shock compressed to 120 GPa

In contrast to relatively pure silica glass (fused silica-FS), commercial silica-rich glasses contain significant fractions of additional oxide components. In particular, soda-lime glass (SLG) consists of approximately 71% SiO 2 by weight, which raises the question: what is the effect of additional cations on the shock compression response of silica-rich glasses? To address this concern, plate impact experiments were conducted to determine the high-pressure Hugoniot states for shocked SLG (37 to 120 GPa) and compared with recently reported results on FS. Using laser interferometry, particle velocity profiles were measured at the impact surface and the SLG/LiF window interface. In all experiments, the transmitted profiles show a single shock wave, with no features indicative of a phase transformation. The Hugoniot states determined from the wave profiles are described well using a linear shock velocity–particle velocity relation. Interferometry measurements (using 1550-nm wavelength laser) at the impact surface show that SLG is transparent when shocked to 55 GPa, transparent for tens of nanoseconds after impact between 55 and 81 GPa, and opaque beyond 81 GPa. From impact surface measurements, a linear relationship between the apparent and true particle velocity was observed, resulting in a linear relationship between the refractive index (at 1550 nm) and density. At 120 GPa, the SLG density is nearly twice its ambient value, indicating that SLG can achieve highly dense amorphous states. When compared to FS, shocked SLG is much less compressible and likely does not transform to a crystalline phase. A plausible explanation for this difference is indicated.

58 GEOSCIENCES↗

Increasing Baselines and Precision of Optical Interferometers Using Two-Photon Interference

Observations using interferometers provide sensitivity to features of images on angular scales much smaller than any single telescope, on the order of Δθ ~ λ/b where b is the interferometric baseline. Present-day optical interferometers are essentially classical, interfering single photons with themselves. However, there is a new wave of interest in interferometry using multiple photons, whose mechanisms are inherently quantum mechanical, which offer the prospects of increased baselines and finer resolutions among other advantages. We will discuss recent ideas and results for quantum-assisted interferometry using the resource of entangled pairs, and specifically a two-photon amplitude technique aimed at improved precision in astrometry.

47 OTHER INSTRUMENTATION↗

Effect of injected flux and current temporal phasing on self-organization in the HIT-SI3 experiment

The HIT-SI3 device at the University of Washington uses three oscillating inductive helicity injectors to form and sustain spheromak plasma equilibria. By adjusting the temporal phase of the injector waveforms with respect to each other, the toroidal spectrum of the imposed perturbations can be controlled. Using a recently implemented GPU-based control system, the available mode spectra were explored experimentally by scanning the space of relative injector phasing. In this space, significant variation in the toroidal mode spectrum ($n$ = 1, 2, 3) of the perturbations was observed. Additionally, variation in characteristics of driven equilibria was also observed, including a ≈ $30$% range in toroidal current gain ($I$ $Φ$ / $I$ $Inj$ ). Experimental results are compared with both a composite-equilibria and nonlinear dynamic model, including extended MHD simulations using the NIMROD code and composite Taylor state equilibria computed using the PSI-Tet code. In conclusion, qualitative agreement is seen with the nonlinear models, but not with composite-equilibria models, suggesting the use of nonlinear models to better capture observed plasma dynamics and provide predictive use for future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Momentum-exchange interactions in a Bragg atom interferometer suppress Doppler dephasing

Large ensembles of laser-cooled atoms interacting through infinite-range photon-mediated interactions are powerful platforms for quantum simulation and sensing. Here we realize momentum-exchange interactions in which pairs of atoms exchange their momentum states by collective emission and absorption of photons from a common cavity mode, a process equivalent to a spin-exchange or XX collective Heisenberg interaction. The momentum-exchange interaction leads to an observed all-to-all Ising-like interaction in a matter-wave interferometer. A many-body energy gap also emerges, effectively binding interferometer matter-wave packets together to suppress Doppler dephasing in analogy to Mössbauer spectroscopy. The tunable momentum-exchange interaction expands the capabilities of quantum interaction–enhanced matter-wave interferometry and may enable the realization of exotic behaviors, including simulations of superconductors and dynamical gauge fields.

Science & Technology - Other Topics↗

Multiloop and multiaxis atomtronic Sagnac interferometry

We report the experimental realization of a large-area and multiaxis atomtronic interferometer in an optical waveguide for rotation sensing. A large enclosed area is achieved through multiloop operation in a guided-atom interferometer using Bose-Einstein condensates. We demonstrate a three-loop interferometer with a total interrogation time of ∼ 0.4 s and an enclosed area of 8.7 mm 2 —the largest reported in a fully guided or one-dimensional setup. High-contrast interference fringes are observed for up to five Sagnac orbits in a smaller loop-area configuration. Our approach enables interleaved rotation measurements about multiple arbitrary axes within the same experimental setup. We present results for area-enclosing interferometers in both horizontal and vertical planes, demonstrating that the interferometer contrast remains comparable across orthogonal orientations of the enclosed area vectors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Matter-wave interference of a native polypeptide

The de Broglie wave nature of matter is a paradigmatic example of quantum physics and it has been exploited in precision measurements of forces and fundamental constants. However, matter-wave interferometry has remained an outstanding challenge for natural polypeptides, building blocks of life, which are fragile and difficult to handle. Here, we demonstrate the wave nature of gramicidin, a natural antibiotic composed of 15 amino acids. Its center of mass is delocalized over more than 20 times the molecular size in our timedomain Talbot-Lau interferometer. We compare the observed interference fringes with a model that includes both a rigorous treatment of the peptide’s quantum wave nature as well as a quantum chemical assessment of its optical properties to distinguish our result from classical predictions. The realization of quantum optics with this prototypical biomolecule paves the way for quantum-assisted measurements on a large class of biologically relevant molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast quantum interferometry at the nanometer and attosecond scales with energy-entangled photons

In classical optical interferometry, loss and background complicate achieving fast nanometer-resolution measurements with illumination at low light levels. Conversely, quantum two-photon interference is unaffected by loss and background, but nanometer-scale resolution is physically difficult to realize. As a solution, we enhance two-photon interference with highly nondegenerate energy entanglement featuring photon frequencies separated by 177 THz. We observe measurement resolution at the nanometer (attosecond) scale with only O(10 4 ) photon pairs, despite the presence of background and loss. Our nondestructive thickness measurement of a metallic thin film agrees with atomic force microscopy, which often achieves better resolution via destructive means. With contactless, nondestructive measurements in seconds or faster, our instrument enables metrological studies in optically challenging contexts where background, loss, or photosensitivity are factors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Collective plasma effects of electron–positron pairs in beam-driven QED cascades

Understanding the interplay of strong-field QED and collective plasma effects is important for explaining extreme astrophysical environments like magnetars. It has been shown that QED pair plasma can be produced and observed by passing a relativistic electron beam through an intense laser field. This work presents in detail multiple sets of 3D QED-particle-in-cell simulations to show the creation of pair plasma in the QED cascade. The beam driven method enables a high pair particle density and also a low particle Lorentz factor, which both play equal roles on exhibiting large collective plasma effects. Finite laser frequency upshift is observed with both ideal parameters (24 PW laser colliding with a 300 GeV electron beam) and with existing technologies (3 PW laser colliding with a 30 GeV electron beam).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanoscale electrostatic control in ultraclean van der Waals heterostructures by local anodic oxidation of graphite gates

In an all-van der Waals heterostructure, the active layer, gate dielectrics and gate electrodes are assembled from two-dimensional crystals that have a low density of atomic defects. This design allows two-dimensional electron systems with very low disorder to be created, particularly in heterostructures where the active layer also has intrinsically low disorder, such as crystalline graphene layers or metal dichalcogenide heterobilayers. A key missing ingredient has been nanoscale electrostatic control, with existing methods for fabricated local gates typically introducing unwanted contamination. Here we describe a resist-free local anodic oxidation process for patterning sub-100 nm features in graphite gates, and their subsequent integration into an all-van der Waals heterostructure. We define a quantum point contact in the fractional quantum Hall regime as a benchmark device and observe signatures of chiral Luttinger liquid behaviour, indicating an absence of extrinsic scattering centres in the vicinity of the point contact. In the integer quantum Hall regime, we demonstrate in situ control of the edge confinement potential, a key requirement for the precision control of chiral edge states. In conclusion, this technique may enable the fabrication of devices capable of single anyon control and coherent edge-state interferometry in the fractional quantum Hall regime.

36 MATERIALS SCIENCE↗

TriWaSp: a multi-faceted visible spectroscopy diagnostic on the ST40 tokamak

Here, we present a new state-of-the-art Triple Wavelength Spectrometer (TriWaSp), recently deployed on ST40, a high field low aspect ratio spherical tokamak. The TriWaSp has a range of possible applications due to its flexible design; the current configuration focuses on charge exchange recombination spectroscopy from carbon and neon impurities in the ST40 plasma. This paper discusses the detailed setup of the system and presents initial charge exchange ion temperature measurements using a single line of sight, which show good agreement with other ion temperature diagnostics. Building on these commissioning results and forward modelling of the system, a new observation geometry has been implemented for the next experimental campaign which will considerably improve the localisation of ion temperature and velocity profile measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Free space Thomson scattering to study high energy density shocks

A free space collective Thomson scattering system has been developed to study pulsed power produced plasmas. While most Thomson scattering diagnostics on pulsed power machines use a bundle of fibers to couple scattered light from the plasma to the spectrometer, this system used free space coupling of the light, which enabled a spatially continuous image of the plasma. Initial experiments with this diagnostic were performed on an inverse wire array generated by a 200 kA, 1100 ns rise time pulse power generator. The capabilities of this diagnostic were demonstrated by using the low frequency ion acoustic wave feature of the Thomson scattering spectra to measure the plasma flow velocity. The diagnostic was demonstrated to measure velocities between 20 and 40 km/s with an error of 4.7 km/s when fitting with a 600 μm spatial resolution or 8.9 km/s when fitting with a 150 μm spatial resolution. In some experiments, the diagnostic observed a bow shock in the plasma flow as the scattering intensity increased and flow velocity decreased.

47 OTHER INSTRUMENTATION↗

Interferometric measurements of graphene-based membranes for micromechanical applications

Recent studies on piezoelectricity in 2D materials, such as graphene, have revealed their potential in multiple applications including microelectromechanical systems. Herein, we reveal piezoelectricity in few-layer graphene sheets deposited on amorphous Si 3 N 4 membranes. The response in the center of square membrane of 6.7 × 6.7 mm 2 size reaches about 14 nm at resonance and could be further enhanced by adjusting the composite structure. Resonance piezoelectric phenomena are fully consistent with the earlier piezoresponse force microscopy observations on free-standing piezoelectric graphene and open up a possibility of using 2D materials in micromechanical applications.

36 MATERIALS SCIENCE↗

Selective Dynamical Imaging of Interferometric Data

Recent developments in very long baseline interferometry (VLBI) have made it possible for the Event Horizon Telescope (EHT) to resolve the innermost accretion flows of the largest supermassive black holes on the sky. The sparse nature of the EHT’s (u, v)-coverage presents a challenge when attempting to resolve highly time-variable sources. We demonstrate that the changing (u, v)-coverage of the EHT can contain regions of time over the course of a single observation that facilitate dynamical imaging. These optimal time regions typically have projected baseline distributions that are approximately angularly isotropic and radially homogeneous. We derive a metric of coverage quality based on baseline isotropy and density that is capable of ranking array configurations by their ability to produce accurate dynamical reconstructions. We compare this metric to existing metrics in the literature and investigate their utility by performing dynamical reconstructions on synthetic data from simulated EHT observations of sources with simple orbital variability. We then use these results to make recommendations for imaging the 2017 EHT Sgr A* data set.

79 ASTRONOMY AND ASTROPHYSICS↗

ARMADA. I. Triple Companions Detected in B-type Binaries α Del and ν Gem

Ground-based optical long-baseline interferometry has the power to measure the orbits of close binary systems at ∼10 μas precision. This precision makes it possible to detect “wobbles” in the binary motion due to the gravitational pull from additional short-period companions. We started the ARrangement for Micro-Arcsecond Differential Astrometry (ARMADA) survey with the Michigan Infra-Red Combiner (MIRC)/MIRC-X instrument at the Center for High Angular Resoloution Astronomy (CHARA) array for the purpose of detecting giant planets and stellar companions orbiting individual stars in binary systems. We describe our observations for the survey, and introduce the wavelength calibration scheme that delivers precision at the tens of microarcseconds level for <02 binaries. We test our instrument performance on a known triple system, κ Peg, and show that our survey is delivering a factor of 10 better precision than previous similar surveys. We present astrometric detections of tertiary components to two B-type binaries: a 30 day companion to α Del, and a 50 day companion to ν Gem. We also collected radial velocity data for α Del with the Tennessee State University Automated Spectroscopic Telescope at Fairborn Observatory. We are able to measure the orbits and masses of all three components in these systems. We find that the previously published radial velocity orbit for the inner pair of ν Gem is not consistent with our visual orbit. The precision achieved for these orbits suggests that our ARMADA survey will be successful at discovering new compact triple systems to A/B-type binary systems, leading to better statistics of hierarchical system architectures and formation history.

47 OTHER INSTRUMENTATION↗