Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interconnections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Value of Nuclear Energy to the Reliability of the North American Power System: Results for Western and Eastern Interconnections

This report documents the fulfillment of a milestone for the United States (U.S.) Department of Energy Office of Nuclear Energy Light Water Reactor Sustainability Program: completing a baseline study of regional impact of nuclear power plants and hydrogen production in maintaining grid services and power quality. Models have been comprehensively demonstrated for the Western Interconnection, or Western Electric Coordinating Council area, and in the Eastern Interconnection for scenarios representative of past extreme events (e.g., drought and heat waves). Understanding the impact on the reliability of the bulk electric system of any reduction in generation capacity from nuclear power, for any reason, is the motivation of this work. Factors that might lead to the premature or unplanned closure of nuclear plants, extended outages, or repurposing of nuclear power include: • Aging infrastructure: Many nuclear power plants in the U.S. are nearing the end of their designed operating lives. Upgrading aging infrastructure can be expensive, and some utilities may choose to retire plants rather than invest in costly upgrades. • Low wholesale electricity prices: The deregulation of the electricity market in many states has led to increased competition and driven down wholesale electricity prices, causing nuclear power operators to seek other revenue sources for their heat and power such as clean hydrogen production. • Renewables growth: The rapid growth of renewable energy sources like solar and wind power is posing a challenge to traditional generation sources like nuclear. While many see renewables as a key part of the clean energy transition, their intermittent nature requires additional grid solutions for reliable power supply. • The potential for regulatory decisions to be in conflict: In its 2021 rulemaking, EPA rule (86 FR 880), the Environmental Protection Agency (EPA) set a compliance date for the ban on processing and distribution in commerce of Decabromodiphenyl Ether (DecaBDE). Since DecaBDE is in many components, particularly wiring, of nuclear power plants which are deemed safety-related or important to safety, three plants would not have been able to restart after their 2023 spring outages, and numerous others would have faced issues in the near future. Fortunately, in this case, the EPA provided relief to the nuclear energy industry. The report provides a summary of the significant role nuclear energy plays in the United States’ power generation mix, supplying around 20% of the nation’s electricity generation, spread across 28 U.S. states. Nuclear power is reliable, mostly unaffected by weather and seasonal changes, and provides a consistent source of baseload power. In terms of capacity, nuclear power plants account for as much as 26% of balancing area power generation capacity. Nuclear power also provides a substantial contribution (e.g., 10% of the inertia in the Eastern Interconnection) of the synchronous spinning mass/inertia that buffers the rate at which frequency changes when a load and generation imbalance occurs (e.g., a large plant trips or a load is suddenly shed due to a transmission outage). This contribution is critical for maintaining grid stability during sudden changes in load or generation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cloud-Based Demonstration of the Eastern Interconnection Situational Awareness Monitoring System (ESAMS)

This report describes a cloud-based implementation and field demonstration of the Eastern Interconnection Situational Awareness and Monitoring System (ESAMS). ESAMS was developed to support the detection and source localization of forced oscillations using synchrophasor measurements from tie-lines connecting areas served by different reliability coordinators (RCs), so that RCs could better coordinate their response to wide-area events. A previous effort had identified deployment barriers associated with hosting shared situational awareness tools at a single RC. To address these barriers, ESAMS was migrated to Amazon Web Services and evaluated in a six-month field demonstration. ISO New England (ISO-NE) and PJM streamed data to the platform using AWS Direct Connect and a site-to-site VPN, respectively. The resulting multi-utility measurement footprint enabled regional source localization across major portions of the U.S. Eastern Interconnection and supported routine identification of oscillation events. During the final three months of the trial, 24 events above 2 MW/MVAR were detected. The largest detected oscillation approached a 25 MW peak-to-peak amplitude, and the longest persisted intermittently for more than 11 hours. The demonstration also assessed operational considerations—including data transfer volumes, end-to-end latency, and cloud computing costs—and found that network and compute requirements were modest relative to typical cloud capabilities while providing performance comparable to prior on-premises deployments. Overall, the results indicate that cloud hosting can provide a practical path to shared interconnection-wide oscillation monitoring. The cloud ESAMS demonstration establishes a foundation for broader utility participation and for building future wide-area analytics that leverage measurements across organizational boundaries.

Follum, James D.↗

Interconnection Timelines and Costs for Distributed Energy Projects in the United States (2000-2025)

These slides summarize and explain empirical data on interconnection timelines and costs for distributed energy projects connected to U.S. utility distribution systems. The study explores how interconnection metrics vary across states, project sizes, technology types, and over time to indicate progress toward simple, fast, and affordable interconnection. Data encompasses 188 utilities in 24 states. Project types include biomass/biofuels, coal, hydropower, natural gas/oil, solar, storage, wind, hybrid, and

Chelminski, Kathryn↗

Evaluating the Impact of Retiring Synchronous Fossil Fuel Generators on Inter-Area Oscillations in the U.S. Western Interconnection

To facilitate the decarbonization of the power grid, fossil-fuel-based synchronous generators are gradually being retired and replaced by inverter-interfaced renewable energy resources. As synchronous machines get displaced, the characteristics of inter-area oscillation modes in electrical interconnections will change. This paper describes a model-based study of the impact of the retirement of synchronous fossil-fuel generators on the oscillatory characteristics of the US Western Interconnection (WI). Results show that if fossil-fuel-based synchronous machines are replaced by grid-forming inverters, then dominant inter-area modes seen in the WI today will change. New inter-area modes may appear due to the electromechanical energy exchange among remaining hydropower generators clustered in geographical proximity in the northwestern part of the WI. This observation indicates that the evolution in modal properties needs to be closely tracked as the resource mix in electrical interconnections changes.

grid forming inverter, wide area oscillation, Inte↗

IM3 Data Center Driven Grid Stress Dataset for the U.S. Western Interconnection

This dataset provides projected grid stress and reliability results (including all model inputs and outputs from an open-source grid operations modeling framework - GO), for the Integrated Multisector, Multiscale Modeling (IM3) project, under varying levels of data center demand growth between 2025 and 2035 in the U.S. Western Interconnection. The scenarios and sensitivity experiments are combinations of different data center demand growth rates and energy, weather, population and economic pathways. Data center demand growth projections were sourced from the Electric Power Research Institute (EPRI). The data center demand growth projection names are: Low (3.71% annual data center demand growth) Moderate (5% annual data center demand growth) High (10% annual data center demand growth) Higher (15% annual data center demand growth) Energy, weather, population and economic pathways are informed by two Shared Socioeconomic Pathways (SSP3 and SSP5) and two Representative Concentration Pathways (RCP4.5 and RCP8.5) following the hotter general circulation model (GCM) forcing group from a set of perturbed thermodynamics simulations. The resulting pathway names are: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The main scenarios and sensitivity experiments are detailed below. Reference scenario: The projected grid stress and reliability results for the U.S. Western Interconnection from a previous study. This scenario does not consider data center demand growth explicitly. Data center scenario: Building on the reference scenario, this scenario considers various data center growth rates and how they impact the U.S. Western Interconnection. Data center loads are modeled as flat 8760-hr profiles. This scenario does not consider new generation and transmission capacities specifically designed to meet the new data center demands. The related folder is named "flat". Delayed generator retirements sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different levels of natural gas and nuclear generator retirement delays. The resulting scenario names are: (1) postponing 100% nuclear retirements; (2) postponing 100% nuclear and 25% natural gas retirements; (3) postponing only 50% natural gas retirements; (4) postponing 100% nuclear and 50% natural gas retirements; (5) postponing 100% nuclear and 75% natural gas retirements; and (6) postponing 100% nuclear and 100% natural gas retirements. The related folder names are: no_gen_retire_0_gas, no_gen_retire_25_gas, no_gen_retire_50_gas, no_gen_retire_50_gas_only, no_gen_retire_75_gas, and no_gen_retire_100_gas. Demand response through curtailment sensitivity experiment: Building on the data center scenario, this experiment explores the impact of different participation and compensation levels of data center demand response. The resulting scenario names are: (1) 5% demand available for curtailment with 750 $/MWh compensation; (2) 5% demand available for curtailment with 500 $/MWh compensation; (3) 5% demand available for curtailment with 250 $/MWh compensation; (4) 15% demand available for curtailment with 750 $/MWh compensation; (5) 15% demand available for curtailment with 500 $/MWh compensation; and (6) 15% demand available for curtailment with 250 $/MWh compensation. The related folder names are: dr_cost_250_drup_0_drdown_5, dr_cost_250_drup_0_drdown_15, dr_cost_500_drup_0_drdown_5, dr_cost_500_drup_0_drdown_15, dr_cost_750_drup_0_drdown_5, and dr_cost_750_drup_0_drdown_15. Combination of delayed generator retirements and demand response through curtailment sensitivity experiment: The impact of combining postponing 100% nuclear and 25% natural gas retirements with 5% demand available for curtailment with 750 $/MWh compensation is simulated. The related folder is named "dr_cost_750_drup_0_drdown_5_nuc_100_gas_25". Please refer to the README file for a detailed description of the dataset including individual files and references.

Artificial Intelligence↗

Method for forming an electrical interconnect

A method including forming an interconnect in a metal member. The interconnect includes multiple repeating, nested V-shaped structures forming a continuous central portion. A vertex of each of the multiple repeating, nested V-shaped structures adjoins a next vertex of a next V-shaped structure of the multiple repeating, nested V-shaped structures. The method further includes separating the interconnect from the metal member.

42 ENGINEERING↗

Path-synchronous performance monitoring of interconnection networks based on source code attribution

Examples disclosed herein relate to path-synchronous performance monitoring of an interconnection network based on source code attribution. A processing node in the interconnection network has a profiler module to select a network transaction to be monitored, determine a source code attribution associated with the network transaction to be monitored, and issue a network command to execute the network transaction to be monitored. A logger module creates, in a buffer, a node temporal log associated with the network transaction and the network command. A drainer module periodically captures the node temporal log. The processing node has a network interface controller to receive the network command and mark a packet generated for the network command to be temporally tracked and attributed back to the source code attribution at each hop of the interconnection network traversed by the marked packet.

Chabbi, Milind M.↗

Conductive trace interconnection tape

A conductive trace interconnect tape for use with a printed circuit board or a flexible circuit substrate comprises a top insulating layer, an electrically conductive layer, and a bottom insulating layer. The top insulating layer is formed from electrically insulating material and is configured to provide electrical isolation from electrically conductive objects that are positioned on top of the conductive trace interconnect tape. The electrically conductive layer is positioned underneath the top insulating layer. The electrically conductive layer is formed from electrically conductive material and includes electrical interconnect traces, electrical component pads, or electrically conductive planar portions. The bottom insulating layer is positioned underneath the electrically conductive layer. The bottom insulating layer is formed from electrically insulating material and is configured to provide electrical isolation from electrically conductive objects that are positioned on the printed circuit board or flexible circuit substrate.

Hatch, Stephen McGarry↗

Self-Sensing, Stretchable, Active Circuit Arrays: Liquid Metal Paste as a Combination Interconnect and Strain Sensor

Stretchable electrical interconnects and substrate materials are increasingly used to create flexible and con-formable electronic systems for soft robotics, smart textiles, and wearable devices. Wires fabricated using composite or liquid conductive inks encapsulated in silicone enable high strain and are mechanically robust. The resistance of these inter-connects increases with strain, which can present challenges for power delivery and signaling among electronic components. However, this effect can be used directly to estimate strain within a stretchable circuit without the need for additional sensor components. In this work, we present an approach for fabricating fully-stretchable, multi-layer active circuit arrays in silicone using liquid metal paste interconnects, in which power and data wires are re-purposed as strain sensors to estimate substrate deformation. As a proof-of-principle, we demonstrate a 3×3 active circuit array that self-senses relative voltage supply at each node to estimate deformation and consumes less than 10 mA per node. Each node is digitally addressable and performs both analog measurement and digital conversion. All interconnects are fabricated using liquid metal paste, and power, data, and sensing are performed over a shared, four-wire interface in this multi-layer stretchable printed circuit board.

99 GENERAL AND MISCELLANEOUS↗

Towards a Software Development Framework for Interconnected Science Ecosystems

The innovative science of the future must be multi-domain and interconnected to usher in the next generation of “self-driving” laboratories enabling consequential discoveries and transformative inventions. Such a disparate and interconnected ecosystem of scientific instruments will need to evolve using a system-of-systems (SoS) approach. The key to enabling application integration with such an SoS will be the use of Software Development Kits (SDKs). Currently, SDKs facilitate scientific research breakthroughs via algorithmic automation, databases and storage, optimization and structure, pervasive environmental monitoring, among others. However, existing SDKs lack instrument-interoperability and reusability capabilities, do not effectively work in an open federated architectural environment, and are largely isolated within silos of the respective scientific disciplines. Inspired by the scalable SoS framework, this work proposes the development of INTERSECT-SDK to provide a coherent environment for multi-domain scientific applications to benefit from the open federated architecture in an interconnected ecosystem of instruments. This approach will decompose functionality into loosely coupled software services for interoperability among several solutions that do not scale beyond a single domain and/or application. Furthermore, the proposed environment will allow operational and managerial inter-dependence while providing opportunities for the researchers to reuse software components from other domains and build universal solution libraries. We demonstrate this research for microscopy use-case, where we show how INTERSECT-SDK is developing the tools necessary to enable advanced scanning methods and accelerate scientific discovery.

Malviya, Addi Thakur↗

Validation of Interconnection and Interoperability of Grid-Forming Inverters Sourced by Hydrogen Technologies in View of 100% Renewable Microgrids

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

grid-forming↗

Conductive trace interconnection tape

A conductive trace interconnect tape for use with a printed circuit board or a flexible circuit substrate comprises a top insulating layer, an electrically conductive layer, and a bottom insulating layer. The top insulating layer is formed from electrically insulating material and is configured to provide electrical isolation from electrically conductive objects that are positioned on top of the conductive trace interconnect tape. The electrically conductive layer is positioned underneath the top insulating layer. The electrically conductive layer is formed from electrically conductive material and includes electrical interconnect traces, electrical component pads, or electrically conductive planar portions. The bottom insulating layer is positioned underneath the electrically conductive layer. The bottom insulating layer is formed from electrically insulating material and is configured to provide electrical isolation from electrically conductive objects that are positioned on the printed circuit board or flexible circuit substrate.

Hatch, Stephen McGarry↗

A Neural Lyapunov Approach to Transient Stability Assessment in Interconnected Microgrids

We propose a neural Lyapunov approach to assessing transient stability in power electronic-interfaced microgrid interconnections. The problem of transient stability assessment is cast as one of learning a neural network-structured Lyapunov function in the state space. Based on the function learned, a security region is estimated for monitoring the security of interconnected microgrids in real-time operation. The efficacy of the approach is tested and validated in a grid-connected microgrid and a three-microgrid interconnection. A comparison study suggests that the proposed method can achieve a less conservative characterization of the security region, as compared with a conventional approach.

Huang, Tong↗

Phase I Final Technical Report on Energy-Efficient Reconfigurable Universal Accelerator Interconnect

It is well known that application specific computing systems, optimally designed and configured for a given workload, offer much higher energy-efficiency and throughput than general purpose systems. In modern computing systems, heterogeneous computing systems have emerged that exploit the energy and performance benefits of combining various different domain-specific processor architectures. Application domains such as high-performance computing and machine learning now process terabyte-sized data sets, requiring enormous processing and memory resources. These applications have very high-power consumption due to bottlenecks in the electrical interconnection between processing units. This project aims to reduce both communication energy and latency by integrating universally available accelerators with silicon photonics. It also aims to increase system throughput by exploiting emerging technologies in silicon photonic reconfigurable interconnects; this will allow the system to balance itself in real time to accommodate changes in workloads and data flows.

2.5D/3D integration↗

Role of Scaffold Architecture and Excess Surface Polymer Layers in a 3D-Interconnected Ceramic/Polymer Composite Electrolyte

3D-interconnected ceramic/polymer composite electrolytes offer promise to combine the benefits of both ceramic and polymer electrolytes. However, an in-depth understanding of the role of the ceramic scaffold's architecture, and the associated polymer/ceramic interfaces on the electrochemical properties of such composite electrolytes is still incomplete. Here, these factors are systematically evaluated using an interconnected composite electrolyte with a tunable and well-defined architecture. The ionic conductivity of the ceramic scaffold is strongly dependent on its porosity and tortuosity, as demonstrated experimentally and via theoretical modeling. The connectivity of the ceramic framework avoids the high interfacial impedance at the polymer/ceramic electrolyte interface within the composite. However, this work discovers that the interfacial impedance between the bulk composite and excess surface polymer layers of the composite membrane dominates the overall impedance, resulting in a 1–2 order drop of ionic conductivity compared to the ceramic scaffold. Despite the high impedance interfaces, an improved Li + transference number is found compared to the neat polymer (0.29 vs 0.05), attributed to the ceramic phase's contributions toward ion transport. Further, this leads to flatter overpotentials in lithium symmetric cell cycling. These results are expected to guide future research directions toward scalable manufacturing of composite electrolytes with optimized architecture and interfaces.

25 ENERGY STORAGE↗

MPC-based double-layer real-time conditional cSelf-restoration for interconnected microgrids

In this report, we propose a novel model predictive control(MPC)-based real-time conditional self-restoration energy management system (CSR-EMS) for interconnected microgrids (IMGs) integrated with renewable energy sources (RESs) and energy storage systems (ESSs). Superior to the existing IMG self-restoration methods, the “conditionality” of the proposed CSR-EMS can economically realize self-restoration and grid-assisted restoration during energy deficiency or faults, in both islanded and grid-connected modes. Cost minimization is implemented as the objective function to judge in real-time which restoration mode is economically preferred. The proposed CSR-EMS comprises two layers–the lower layer operates locally to eliminate electricity fluctuations created by RESs and ensure economic effectiveness within an MG, whereas the upper layer oversees the real-time operational status of the IMG system and determines power exchange among microgrids (MGs) during abnormalities. In detail, when a microgrid inside the IMG system experiences an energy deficiency, the CSR-EMS, on an MPC basis, intelligently optimizes power production from each dispatchable distributed generator (DG), ESS, power imported from the main grid, and power exchange among the IMGs to maintain the demand–supply balance, while considering system recovery cost, state of charge (SoC) of ESSs and operation modes of the IMGs (i.e., grid-connected or islanded mode). Simulation results and comparisons with existing IMG self-healing EMSs demonstrate the economic efficacy of the proposed CSR-EMS strategy during normal and abnormal operations, which can be used as an energy control framework for modern power systems with multiple interconnected microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance of stainless steel interconnects with (Mn,Co) 3 O 4 -Based coating for solid oxide electrolysis

Mixed transition-metal oxide coatings are commonly applied to stainless steel interconnects for solid oxide cell stacks. Such coatings reduce oxidation and Cr evaporation rates, leading to improved degradation rate and stack lifetime. Here, the ChromLok™ MCO-based composition (Mn,Co) 3 O 4 is applied to Crofer 22 APU stainless steel and evaluated specifically for application in solid oxide electrolyzer stacks operating around 800 °C and utilizing oxygen-ion-conducting solid oxide cells. The MCO coating is found to decrease the stainless steel oxidation rate by about one order of magnitude, and decrease the Cr evaporation rate by fourfold. Furthermore, the coating also dramatically lowers the rate of area-specific resistance increase for stainless steel coupons oxidized for 500 h with constant current applied, from 33 mΩ*cm 2 kh -1 for an uncoated coupon to less than 4 mΩ*cm2 kh -1 for coated coupons. The coating is demonstrated on full-scale interconnects for single-cells, where the coating dramatically reduces degradation rate, and for a stack, which displays stable operation for 700 h.

08 HYDROGEN↗

Dynamic oxidation of (Mn,Co) 3 O 4 -Coated interconnects for solid oxide electrolysis cells

Solid oxide electrolysis cell stacks are expected to experience dynamic conditions when using renewable electricity derived from wind or solar power. To address this scenario, (Mn,Co) 3 O 4 (MCO)-coated Crofer 22 APU interconnect coupons are subjected to thermal cycling, and intermittent current density, with gas compositions relevant to high-temperature electrolysis (elevated steam:hydrogen ratio and oxygen content). Defects are also intentionally introduced in the MCO coating, to assess whether the difference in oxidation properties of the adjacent coated and uncoated (defective) surfaces causes sufficient stress to damage the protective oxide scale. Specimens with defects are subjected to oxidation for 1000 h at 800 °C, or thermal cycling. Before thermal cycling, some specimens are pre-oxidized to create a thick oxide scale to mimic the scale thickness expected after ~30 kh operation. In all cases, the coating and oxide scale remain well adhered with no cracking observed. Area-specific resistance (ASR) is monitored in both single-atmosphere and dual-atmosphere conditions, and the ASR is stable and is not impacted by dynamic cycling of the current density. Finally, this work provides confidence that the MCO coated interconnect will function as needed in dynamic operation conditions, even with coating defects.

08 HYDROGEN↗