Rossi-alpha Analysis of CURIE Experiment
Critical assembly measurement and operations are crucial to the development of benchmark data to support research into criticality safety, radiation-detection development, and the overall application of nuclear technologies. Accurate nuclear data are needed for accurate predictive simulations, and validation using critical experiments is an important part of the nuclear data pipeline. The accuracy of nuclear data are improved using more robust and targeted measurements. In particular, the intermediate energy range of uranium is of great interest. LANL has successfully performed the Zeus series of experiments on the Comet assembly to investigate the intermediate energy range for HEU with various moderators. A successor to these experiments is the benchmark for the Critical Unresolved Region Integral Experiment (CURIE), designed to be sensitive to the unresolved resonance region (URR). This experiment is designed using polytetrafluoroethylene, more commonly known as Teflon, moderators. The CURIE experiment was successfully conducted at the National Criticality Experiments Research Center (NCERC). The Rossi-alpha method was used to evaluate the propensity of the CURIE configurations to sustain fission chains by estimating the prompt neutron decay constant α. This work evaluates the α at delayed critical using Rossi-alpha for different Teflon moderator thicknesses in the CURIE experiment. These results will help improve understanding of the CURIE benchmark experiments.