Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “inductive loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Half-Bridge On-State Voltage Sensor for In-Situ Measurements

Current prognostics for life expectancy of power semiconductors utilize off-line measurements of the on-state resistance. Presented is a half-bridge (HB) on-state voltage (VON) sensor capable of being utilized for in-situ measurements enabling continuous and real-time monitoring of the on-state resistance. The design provides a single VON measurement output that contains independent VON information of both high and low side devices in a HB leg. The measurement output is referenced from the middle point of the HB and combines the two complementary VON sensing outputs. This system reduces the number of components, required number of analog signal processing circuits, and ADC channels for in-situ health monitoring of a power electronics system. These reductions will facilitate integration of the VON sensor with the gate driver board and achieve low system profile. The experimental results demonstrate the proposed VON measurements while switching with inductive and resistive loads.

Roy, Chondon↗

A Soft-Switching Inverter for High-Temperature Advanced Hybrid Electric Vehicle Traction Motor Drives

The state-of-the-art hybrid electric vehicles (HEVs) require the inverter cooling system to have a separate loop to avoid power semiconductor junction over temperatures because the engine coolant temperature of 105°C does not allow for much temperature rise in silicon devices. The proposed work is to develop an advanced soft-switching inverter that will eliminate the device switching loss and cut down the power loss so that the inverter can operate at high-temperature conditions while operating at high switching frequencies with small current ripple in low inductance based permanent magnet motors. The proposed tasks also include high-temperature packaging and thermal modeling and simulation to ensure the packaged module can operate at the desired temperature. The developed module will be integrated with the motor and vehicle controller for dynamometer and in-vehicle testing to prove its superiority. This report will describe the detailed technical design of the soft-switching inverters and their test results. The experiments were conducted both in module level for the module conduction and switching characteristics and in inverter level for its efficiency under inductive and dynamometer load conditions. The performance will be compared with the DOE original specification.

33 ADVANCED PROPULSION SYSTEMS↗

Sensitivity Analysis of a Wireless Power Transfer (WPT) System for Electric Vehicle Application

This paper presents a detailed parametric sensitivity analysis for a wireless power transfer (WPT) system in electric vehicle application. Specifically, several key parameters for sensitivity analysis of a series-parallel (SP) WPT system are derived first based on analytical modeling approach, which includes the equivalent input impedance, active / reactive power, and DC voltage gain. Based on the derivation, the impact of primary side compensation capacitance, coupling coefficient, transformer leakage inductance, and different load conditions on the DC voltage gain curve and power curve are studied and analyzed. It is shown that the desired power can be achieved by just changing frequency or voltage depending on the design value of coupling coefficient. However, in some cases both have to be modified in order to achieve the required power transfer.

electric vehicle↗

AMAROK: A Radio Frequency Development Platform for High-Power, Full-Scale Positive Ion Sources for DIII-D Neutral Beam Injectors

Next-generation neutral beam injection (NBI) systems demand RF ion sources capable of efficiently coupling >120 kW at 2–4-MHz frequencies, yet existing designs face voltage standoff and impedance-matching challenges. To address this, the advanced multicoil antenna for RF operations at kilowatts (AMAROK) was developed as a high-power RF inductively coupled plasma (ICP) source delivering up to 200 kW in the 2–4-MHz range via four phase-controlled generators for flexible power sharing. Two antenna designs—a single-strap multiturn (MT) and a multistrap single-turn (ST) design—were evaluated to optimize resonance, impedance matching, and power coupling across plasma loads. Here, a semi-analytical self-resonant frequency (SRF) model, validated experimentally, predicts resonance trends for arbitrary turn counts and tubing diameters, enabling rapid antenna optimization. Strap-to-strap mutual inductance in the ST configuration showed strong spatial dependence, guiding generator operation and total load inductance. These insights informed a custom π -topology matching network, achieving stable impedance matching over a wide range of plasma-driven loads. Collectively, these results position AMAROK as a versatile testbed for advancing high-power RF source technology in fusion NBI applications.

DIII-D↗

Discrete Empirical Interpolation Method Based Dynamic Load Model Reduction

Dynamic load models add significant complexity to bulk power system time-domain simulations. The complexity is due to the large number of ordinary differential equations (ODEs) introduced by the dynamic load components such as induction motors. It is challenging to derive reduced-order models (ROMs) for dynamic loads due to the nonlinear functions in their governing equations. This paper applies the discrete empirical interpolation method enhanced proper orthogonal decomposition (DEIM-POD) to approximate the full dynamic load model with the ROM that minimizes the projection error of the nonlinear functions in dynamic load ODEs onto their dominant modes. This approach only requires evaluation of nonlinear functions at selected observation points. The observation points selected by DEIM also provide information for screening critical load buses where dynamic load model parameters contribute the most to the accuracy of ROM across multiple contingencies. The proposed approach is validated on IEEE 9-bus, WECC 179-bus and 2384-bus Polish systems.

bulk power system↗

Single-Event Latchup Testing of the Micrel MIC4424 Dual Power MOSFET Driver

We conducted 47 exposures of four different MIC4424 devices and did not observe any SEL or high-current events. This included worst-case conditions with a LET of 81 MeV-sq cm/mg, applied voltage of 18.5 V, a case temperature greater than 120 C, and a final fluence of 1x10(exp 7)/sq cm. We also monitored both the outputs for the presence of SETs. While the period of the 1 MHz square wave was slightly altered in some cases, no pulses were added or deleted. 1. Purpose: The purpose of this testing is to characterize the BiCMOS/DMOS Micrel MIC4424 dual, non-inverting MOSFET driver for single-event latchup (SEL) susceptibility. These data will be used for flight lot evaluation purposes. 2. Devices Tested: The MIC4423/4424/4425 family are highly reliable BiCMOS/DMOS buffer/driver MOSFET drivers. They are higher output current versions of the MIC4426/4427/4428. They can survive up to 5V of noise spiking, of either polarity, on the ground pin. They can accept, without either damage or logic upset, up to half an amp of reverse current (either polarity) forced back into their outputs. Primarily intended for driving power MOSFETs, the MIC4423/4424/4425 drivers are suitable for driving other loads (capacitive, resistive, or inductive) which require low-impedance, high peak currents, and fast switching times. Heavily loaded clock lines, coaxial cables, or piezoelectric transducers are some examples. The only known limitation on loading is that total power dissipated in the driver must be kept within the maximum power dissipation limits of the package. Five (5) parts were provided for SEL testing. We prepared four parts for irradiation and reserved one piece as an un-irradiated control. More information about the devices can be found in Table 1. The parts were prepared for testing by removing the lid from the CDIP package to expose the target die. The parts were then soldered to small copper circuit adapter boards for easy handling. These parts are fabricated in a bulk BiCMOS/DMOS technology. Since we do not know the number of overlayers used in the fabrication processes, linear energy transfer calculations are determined based on the top-surface incident ion species and kinetic energy.

Power MOSFET↗

Characteristics of a molybdenum X-pinch X-ray source as a probe source for X-ray diffraction studies

X-ray emission from a molybdenum X-pinch has been investigated as a potential probe for the high pressure states made in dynamic compression experiments. Studies were performed on a novel 300 kA, 400 ns generator which coupled the load directly to a low inductance capacitor and switch combination. The X-pinch load consisted of 4 crossed molybdenum wires of 13 μm diameter, crossed at an angle of 62°. The load height was 10 mm. An initial x-ray burst generated at the wire crossing point, radiated in the soft x-ray range (hυ < 10 keV). This was followed, 2–5 ns later, by at least one harder x-ray burst (hυ > 10 keV) whose power ranged from 1 to 7 MW. Time integrated spectral measurements showed that the harder bursts were dominated by K-alpha emission; though, a lower level, wide band continuum up to at least 30 keV was also present. Initial tests demonstrated that the source was capable of driving Laue diffraction experiments, probing uncompressed samples of LiF and aluminium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchronizing Rotation Of A Heavy Load

Drive system rotates large-inertia load at constant low speed. Simple setup of motors, pulleys, and belts provides both torque and synchronism. Induction motor drives two loads: rotating instrument and slightly lagging synchronous motor. Provides ample torque to start and maintain rotation, and synchronous motor ensures rotation synchronized with ac power supply.

Ratliff, Roger↗

Energy saving concepts relating to induction generators

Energy saving concepts relating to induction generators are presented. The first describes a regenerative scheme using an induction generator as a variable load for prime movers under test is described. A method for reducing losses in induction machines used specifically as wind driven generators is also described.

Nola, F. J.↗

Fundamental-Frequency-Modulated Six-Level Diode-Clamped Multilevel Inverter for Three-Phase Stand-Alone Photovoltaic System

This paper presents a fundamental-frequency-modulated diode-clamped multilevel inverter (DCMLI) scheme for a three-phase stand-alone photovoltaic (PV) system. The system consists of five series-connected PV modules, a six-level DCMLI generating fundamental-modulation staircase three-phase output voltages, and a three-phase induction motor as the load. In order to validate the proposed concept, simulation studies and experimental measurements using a small-scale laboratory prototype are also presented. The results show the feasibility of the fundamental frequency switching application in three-phase stand-alone PV power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear dynamics of a plasma-filled diode in the presence of a magnetic field with loads

A plasma-filled diode can be taken as a simplified model for the interaction space of some microwave oscillators, such as, virtual cathode oscillators. A magnetic field has played an important role in showing the nonlinear dynamics of the diode in a previous study. In the presence of a magnetic field, the diode is connected to various types of loads consisting of capacitance, inductance, and resistance in series. The nonlinear dynamics and chaos have been investigated by using both analytical analysis and particle-in-cell simulation. It has been shown that the diode can operate in different dynamical regimes: steady, oscillatory, chaotic, and unstable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mitigation of Motor Stalling and FIDVR via Energy Storage Systems with Temporal Logic Specifications

The fault-induced delayed voltage recovery (FIDVR) phenomenon has been very common from the distribution system through the transmission system. It causes a delay on recovering significantly depressed local voltage after the fault is cleared, and it can also lead to more widespread cascading system failures. Mitigating this event with current control approaches is challenging and becoming a crucial issue. Here, a model predictive control-based strategy employing signal temporal logic specifications is proposed to help mitigate FIDVR. To this end, it investigates and extends a dynamic performance model allowing analytic insights into the system-wide impact of motor stalling and FIDVR. The proposed controller provides richer descriptions of voltage specifications addressing both magnitude and time simultaneously. We consider different control specifications with reactive power support from energy storage systems to prevent the voltage during/after the fault from dropping too low, and reduce the delay time of voltage recovery. The simulation results conducted with the IEEE 57 bus test network validate the proposed method and demonstrate the effectiveness of the mitigation strategy on FIDVR.

25 ENERGY STORAGE↗

A HIGH BANDWIDTH BIPOLAR POWER SUPPLY FOR THE FAST CORRECTORS IN THE APS UPGRADE*

The APS Upgrade of a multi-bend achromat (MBA) storage ring requires a fast bipolar power supply for the fast correction magnets. The key performance requirement of the power supply includes a small-signal bandwidth of 10 kHz for the output current. This requirement presents a challenge to the design because of the high inductance of the magnet load and a limited input DC voltage. A prototype DC/DC power supply utilizing a MOSFET H-bridge circuit with a 500 kHz PWM has been developed and tested successfully. The prototype achieved a 10-kHz bandwidth with less than 3-dB attenuation for a signal 0.5% of the maximum operating current of 15 amperes. This paper presents the design of the power circuit, the PWM method, the control loop, and the test results.

A HIGH BANDWIDTH BIPOLAR POWER SUPPLY↗

Experimental Evaluation of PV Inverter Anti-Islanding with Grid Support Functions in Multi-Inverter Island Scenarios

As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1.) In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2.) The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness. Crucially, the multi-inverter anti-islanding tests described in this report examine scenarios with multiple inverters connected to multiple different points on the grid. While this so-called 'solar subdivision' scenario has been examined to some extent through simulation, this is the first known work to test it using hardware inverters. This was accomplished through the use of power hardware-in-the-loop (PHIL) simulation, which allows the hardware inverters to be connected to a real-time transient simulation of an electric power system that can be easily reconfigured to test various distribution circuit scenarios. The anti-islanding test design was a modified version of the unintentional islanding test in IEEE Standard 1547.1, which creates a balanced, resonant island with the intent of creating a highly challenging condition for island detection. Three common, commercially available single-phase PV inverters from three different manufacturers were tested. The first part of this work examined each inverter individually using a series of pure hardware resistive-inductive-capacitive (RLC) resonant load based anti-islanding tests to determine the worst-case configuration of grid support functions for each inverter. A grid support function is a function an inverter performs to help stabilize the grid or drive the grid back towards its nominal operating point. The four grid support functions examined here were voltage ride-through, frequency ride-through, Volt-VAr control, and frequency-Watt control. The worst-case grid support configuration was defined as the configuration that led to the maximum island duration (or run-on time, ROT) out of 50 tests of each inverter. For each of the three inverters, it was observed that maximum ROT increased when voltage and frequency ride-through were activated. No conclusive evidence was found that Volt-VAr control or frequency-Watt control increased maximum ROT. Over all single-inverter test cases, the maximum ROT was 711 ms, well below the two-second limit currently imposed by IEEE Standard 1547-2003. A subsequent series of 244 experiments tested all three inverters simultaneously in the same island. These tests again used a procedure based on the IEEE 1547.1 unintentional islanding test to create a difficult-to-detect island condition. For these tests, which used the two worst-case grid support function configurations from the single-inverter tests, the inverters were connected to a variety of island circuit topologies designed to represent the variety of multiple-inverter islands that may occur on real distribution circuits. The interconnecting circuits and the resonant island load itself were represented in the real-time PHIL model. PHIL techniques similar to those employed here have been previously used and validated for anti-islanding tests, and the PHIL resonant load model used in this test was successfully validated by comparing single-inverter PHIL tests to conventional tests using an RLC load bank.

24 POWER TRANSMISSION AND DISTRIBUTION↗