On-Board Propulsion System Analysis of High Density Propellants

The impact of the performance and density of on-board propellants on science payload mass of Discovery Program class missions is evaluated. A propulsion system dry mass model, anchored on flight-weight system data from the Near Earth Asteroid Rendezvous mission is used. This model is used to evaluate the performance of liquid oxygen, hydrogen peroxide, hydroxylammonium nitrate, and oxygen difluoride oxidizers with hydrocarbon and metal hydride fuels. Results for the propellants evaluated indicate that the state-of-art, Earth Storable propellants with high performance rhenium engine technology in both the axial and attitude control systems has performance capabilities that can only be exceeded by liquid oxygen/hydrazine, liquid oxygen/diborane and oxygen difluoride/diborane propellant combinations. Potentially lower ground operations costs is the incentive for working with nontoxic propellant combinations.

Schneider, Steven J.↗

BioSTEAMDevelopmentGroup/BLocS

BioSTEAM Location-Specific Evaluation. This module allows BioSTEAM users to consider the impacts of economic and environmental parameters that vary by location. Current location-specific data includes income, property, fuel producer, and sales tax rates; feedstock prices (corn, corn stover, and sugarcane); electricity prices; natural gas prices; location capital cost factors (LCCFs), and tax incentives (available as of February 2020) for all 50 states in the US. Stewart et al. is the first paper to utilize BLocS to explore the influence of policy incentives and location-specific economic parameters on the financial viability of three different biorefineries.

Stewart, Dalton↗

Effects of the U.S. inflation reduction act on SMR economics

The U.S. Inflation Reduction Act (IRA) of 2022 provides a wide array of tax credits and other incentives for low-carbon energy. The technology-neutral clean generation production tax credit (PTC) (Section 45Y of the U.S. Internal Revenue Code) and the technology-neutral investment tax credit (ITC) (Section 48E) lower the net cost of new electricity generation projects with zero or negative greenhouse gas emission rates. We evaluate the impact of the IRA legislation—specifically the PTC and ITC—on the cost-competitiveness of small modular reactors (SMRs). We use the Argonne Low-carbon Energy Analysis Framework (A-LEAF) model to calculate the capacity factor of an SMR with a range of hypothetical variable operating and maintenance (O&M) costs in the Electric Reliability Council of Texas (ERCOT) electricity market. We selected ERCOT for market modeling because of its competitive structure, available data, and extensive use in prior literature. We use a discounted cash flow model to calculate the SMR’s net present value based on the market prices and capacity factors from A-LEAF, hypothetical ranges of capital and variable O&M costs, and other input parameters, with or without the IRA tax credits. We determine the SMR owner’s optimal choice of PTC or ITC for the hypothetical ranges of capital and variable O&M costs. We also evaluate potential shifts in the SMR owner’s optimal choice of PTC or ITC based on historical patterns of nuclear capital cost overruns in the United States. We also assess the sensitivity of our results to longer PTC period and electricity prices from the New England market, which tend to be higher than electricity prices in ERCOT. We find that even with the IRA tax credits, only SMRs with low capital and variable O&M costs would be economically feasible in the low-price ERCOT market scenario modeled. A longer PTC period and higher-price market such as New England, however, would significantly expand the economic feasibility of SMRs in the United States.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Safe, Efficient, and Fair UTM Airspace Management

Unmanned Aircraft Systems (UAS) are increasingly used to perform crucial commercial activities such as various types of inspections (crops, railroads, and bridges), surveillance, and package delivery. Regulators have become interested in developing UAS Traffic Management (UTM) systems. One promising framework for UTM allocates airspace to UAS operators via an auction. To succeed, an airspace auction must be economically efficient, fair, scalable, incentive-aligned, simple, and capable of continuously modeling airspace and sharing bid status and pricing information. This paper introduces the first airspace auction mechanism that meets these criteria. In the process, we introduce new spatial-temporal fairness constraints and a new abstraction for communicating airspace pricing information, the airspace price field. We evaluate our mechanism on UAS delivery scenarios taken from a Japan Aerospace Exploration Agency(JAXA) study and show that it scales to 1000s of bids.

Strategic deconfliction↗

Fault tolerant system performance modeling

With the proliferation of complex digital systems on aircraft, the need to accurately predict system performance early in the system design cycle becomes imperative. In the past, system designers have relied on ad hoc methods for evaluating performance issues. This has produced systems that have not always worked as originally intended. To alleviate these design deficiencies, formal methods, with supporting tools, must be adhered to during the system design process. The use of performance modeling tools is becoming widely accepted as a way to address timing considerations of system design. An additional incentive for the use of these tools is that they allow the system architect to analyze system component interactions (i.e., bus contention, contention of functions for a processing site, and system repair activity on application performance). This inherent flexibility can result in an explicit specification of the system architecture. This paper addresses a method that supports performance modeling of fault tolerant systems using a discrete event simulation tool. An additional focus is on lessons learned from analyzing these classes of problems. The methodology and supporting work provide system architects with the capability to specify candidate architectures and accurately predict their performance in the early stages of design, where changes to system design is most cost effective. The work has been supported under NASA contract NAS1-18099. Integrated Airframe Propulsion Control System Architecture (IAPSA II). This contract addresses methodology, analysis, and detailed design of integrated control system architectures suitable for high-performance aircraft of the 1990's.

Discrete event simulation↗

Sustainable Aviation Fuel State-of-Industry Report: Hydroprocessed Esters and Fatty Acids Pathway

Climate change is a pressing issue that requires immediate and decisive action to ensure a sustainable future. To reduce CO 2 emissions and speed up the transition to net-zero aviation, the Biden administration has launched the "Sustainable Aviation Fuels (SAF) Grand Challenge" to scale up production of SAF. The challenge aims to achieve 20% reduction in aviation emissions by producing 3 billion gallons per year (BGPY) of SAF by 2030 and to meet 100% of aviation fuel demand by producing 35 BGPY of SAF by 2050. In this report, we provide an overview of the current state of the hydroprocessed esters and fatty acids (HEFA) SAF industry, guided by the perspectives of the interviewed experts. Currently, the HEFA pathway is the only commercially deployed method to produce significant amounts of SAF. As a result, SAF produced via the HEFA pathway is expected to make the largest contribution to achieving the 2030 production target and play a key role in boosting and establishing the SAF market. Announced SAF's total capacity, including alcohol-to-jet, FT, and power-to-liquid facilities, is expected to reach 2 BGPY by 2030 (1), with the expected from HEFA. Total HEFA capacity, including construction and planned projects, is expected to reach about 9 BGPY by 2030; if completely executed, this would contribute to renewable diesel (RD) and SAF. The production ratio of SAF and RD will depend on market conditions, incentives, and the capabilities of facilities. While some stakeholders believe that the 2030 goal may be achieved solely via HEFA, others believe that overly relying on HEFA may be detrimental to the development of other necessary pathways to meet 2050 goals. Our conclusion is that the HEFA pathway alone will not be sufficient to reach the 2030 target. It is crucial to implement additional pathways to reach the goal. This report conducts a comprehensive analysis and evaluation of the HEFA SAF value chain. Our aim is to provide current status of the industry and to identify potential challenges that could hinder the commercial production and use of SAF produced through the HEFA pathway. We have had extensive discussions, consultations, and collaborative sessions with stakeholders in the HEFA SAF value chain, including HEFA feedstocks, potential volume of HEFA SAF, economic and sustainability metrics when compared to petroleum, and assessment of the HEFA SAF industry's ability to grow and contribute to achieving the "SAF Grand Challenge." Since the HEFA pathway produces both SAF and RD, this report compares both pathways: HEFA to SAF and HEFA to RD.

09 BIOMASS FUELS↗

Computational Tools and Workflows for Quantitative Risk Assessment and Decision Support for Geologic Carbon Storage Sites: Progress and Insights from the U.S. DOE’s National Risk Assessment Partnership

The 2005 Intergovernmental Panel on Climate Change (IPCC) Special Report on CCS raised the profile of CO2 capture and storage (CCS) as an important technology for reducing greenhouse gas (GHG) emissions. CCS is now recognized as a key component of most climate change mitigation scenarios. Since publication of that report the international research, development, and deployment (RD&D) community has advanced key technical aspects, clarified regulatory requirements, explored value chain and infrastructure solutions, and developed incentive paradigms to enable and promote large-scale deployment of CCS. These efforts have included research to better characterize geologic storage resources, to improve injection performance and storage efficiency, to assess and manage subsurface environmental risks, and to advance monitoring technologies to assure system conformance. These efforts have helped to build confidence in the viability of geologic carbon storage (GCS), but stakeholder concerns about long-term risks and liability associated with GCS remain a hurdle to broad acceptance and large-scale deployment of CCS. Since 2010, the U.S. DOE’s National Risk Assessment Partnership (NRAP) – a research collaboration between five contributing national laboratories – has worked to establish and demonstrate methods and tools to quantify and manage the subsurface environmental risks associated with GCS, amidst uncertainty. This work supports the Office of Fossil Energy and Carbon Management Carbon Transport and Storage Program’s goal of advancing safe and secure commercial-scale GCS deployment. To address the technical challenge of simulating the physical response of the GCS site to large-scale CO2 injection, NRAP has adopted an approach that relies on coupling computationally efficient reduced-order and/or data-driven proxy models of important system components (i.e., storage reservoir, sealing caprock, leakage pathways, intermediate formations, overlying groundwater aquifers, and the atmosphere) in integrated assessment framework. That integrated model of the physical system is complemented with fit-for purpose functionality to support site characterization and risk-related decisions. The recently released NRAP Phase II toolset includes the Open-Source Integrated Assessment Model (NRAP-Open-IAM) for evaluation of trends in leakage risk and potential impact, tools to support monitoring design optimization (Designs for Risk Evaluation and Management – DREAM v3.0 and Passive Seismic Monitoring Tool - PSMT), and tools for state of stress evaluation (State-of-Stress Analysis Tool - SOSAT) and forecasting induced seismicity risk. The NRAP team has also released a pair of reports describing conceptual workflows to incorporate physics-based, quantitative risk assessment into many of the design, planning, operation, and closure decisions for GCS projects. An online catalogue highlights published studies where these tools and methods are demonstrated. In this presentation, the utility of these products to assess risks and address key stakeholder questions will be highlighted through examples, and related insights about the safety and security of geologic carbon storage in qualified storage sites will be discussed. The prospect of rapid, large-scale deployment of GCS technology to aggressively reduce anthropogenic CO2 emissions requires careful consideration of interference between multiple commercial-scale storage projects within a basin. Going forward, NRAP is expanding and adapting site-scale risk quantification tools and methods to enable assessment of risks and inform management decisions for basin-scale deployment. Increasingly, this work will leverage next-generation approaches for surrogate modelling, fast prediction, and advanced visualization enabled by machine learning and artificial intelligence to promote virtual learning, scenario evaluation, and augment risk-based decision making.

quantitative risk assessment, geologic carbon stor↗

A Simplified Building Modeling Approach for Identifying Whole Building Retrofits

Building Energy Modeling (BEM) is an effective strategy for optimizing new and retrofit building design, evaluating its energy savings potential and rating its energy performance. However, because of the complexity and expense of modeling, only a small percentage of buildings are simulated. Over 80% of buildings are <25,000 ft2, and the cost associated with BEM can be a big deterrent for reaching this subsector, which usually ends up complying with energy codes and qualifying for incentives using prescriptive measures or generalized design guides. Similarly, efficiency considerations for small building retrofits are often identified through deemed measures or Technical Reference Manuals, which though a scalable and convenient approach, can limit innovation in design and optimization of measures. Simplification of the modeling process, where appropriate, can lead to increased energy savings and more informed decision making. This paper will discuss the development of a ruleset for a simplified approach based on the Performance Rating Method (PRM) contained in ASHRAE Standard 90.1. The approach aims to simplify and lower the cost of the energy modeling process in a controlled and documented manner. An anticipated outcome is an increased use of BEM and its effectiveness in the design, retrofit and operation of commercial buildings. In addition, simplification of the modeling process will result in fewer errors from misinterpretations of both program requirements and program intent in simulation software. The paper will discuss the need and advantages of a simplified modeling approach for whole building retrofits and the technical process for achieving the same.

Goel, Supriya↗

Electric Vehicle Adoption in Illinois

Over 1.3 million plug-in electric vehicles (PEVs) have been sold in the United States since 2010 when the first Chevy Volt and Nissan Leaf vehicles came on the market. Currently, electric vehicles account for about 2% of monthly light-duty vehicle (LDV) sales. More than 40 different electric vehicle models are actively being marketed, and most of these are LDVs. Over the last few years, automakers have brought more models, with varying mileage ranges, to the market, including medium-duty and heavy-duty trucks and buses. Government agencies at the federal, regional, and state levels, as well as utilities across the United States, have provided financial and non-financial incentives to promote electric vehicle adoption and charging infrastructure deployment. Argonne National Laboratory, sponsored by the U.S. Department of Energy, has developed tools and collected data to quantify the energy, economic, and environmental benefits of electric vehicles. This project has three objectives. First, we summarize the policies and other actions of the federal government, various states/regions, and utilities to promote PEV adoption, and evaluate their relative effectiveness based on a review of the literature. Second, we identify possible PEV adoption paths or scenarios that would result in PEVs making up 15% of all on-road vehicles in Illinois, and we quantify the resulting impacts on petroleum consumption and electricity demand. We also summarize the possible reduction in greenhouse gas (GHG) and criteria pollutant emissions due to PEV adoption. The PEV scenarios include private and public adoption of electric cars, light trucks (e.g., sports utility vehicles [SUVs], vans, pickups), medium-duty vehicles (MDVs), and heavy-duty vehicles (HDVs). Third, we estimate hourly charging loads of light-duty PEVs in 2030 associated with these scenarios, incorporating assumptions about vehicle electric range, efficiency, and travel behavior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Addressing the split incentive challenge for rooftop solar PV and battery energy storage in multifamily rental buildings (CRADA 638 Final Report)

This project advances the understanding of how roof solar PV systems and battery energy storage systems (BESS) can be effectively deployed in multifamily residential buildings, a sector that has historically faced barriers due to misaligned incentives between landlords and tenants. By leveraging high-resolution building stock data and simulation tools, the research demonstrates how energy consumption patterns vary across building types, climates, and occupant characteristics, and how these variations influence the optimal sizing and operation of distributed energy resources. A key contribution is the development of a publicly accessible, web-based tool named RESIDE (Residential Energy Systems & Infrastructure Data Evaluation) that allows users to explore building energy use and evaluate solar and battery configurations without requiring specialized expertise. This significantly lowers the barrier to entry for stakeholders such as property owners, utilities, and policymakers. From a technical perspective, the project shows that integrating rooftop solar PV with battery energy storage can substantially reduce electricity costs and peak demand through strategies such as energy arbitrage and peak shaving. The modeling framework incorporates real-world constraints, including time-of-use electricity pricing and battery degradation, providing realistic and actionable insights. Economically, the results indicate that properly sized systems can deliver meaningful cost savings, improving the feasibility of energy investments in multifamily housing. More broadly, the project benefits the public by supporting the transition to affordable and reliable energy, particularly in rental multifamily housing where adoption has traditionally lagged.

14 SOLAR ENERGY↗

Method of Test for Evaluating Building Performance Simulation Software

ANSI/ASHRAE Standard 140 Method of Test for Evaluating Building Performance Simulation Software specifies the method to test the core competency of building performance simulation (BPS) software, a broad class of software which includes building energy modeling (BEM) software. Standard 140 has been widely used by BEM software vendors to help diagnose and compare the results from the program with other modeling programs. The Standard is also referenced by codes, standards, government programs, and other incentive programs as a part of minimum requirements for qualifying BEM software. The explanatory information, summary tables and figures in this 140 User’s Manual (referred to as “this Manual”) are provided to help users in implementing various suites of tests specified in Standard 140-2023 (referred to in this manual as “Standard 140” or “the Standard”).

97 MATHEMATICS AND COMPUTING↗

Designing Agent Collectives For Systems With Markovian Dynamics

The Collective Intelligence (COIN) framework concerns the design of collectives of agents so that as those agents strive to maximize their individual utility functions, their interaction causes a provided world utility function concerning the entire collective to be also maximized. Here we show how to extend that framework to scenarios having Markovian dynamics when no re-evolution of the system from counter-factual initial conditions (an often expensive calculation) is permitted. Our approach transforms the (time-extended) argument of each agent's utility function before evaluating that function. This transformation has benefits in scenarios not involving Markovian dynamics of an agent's utility function are observable. We investigate this transformation in simulations involving both hear and quadratic (nonlinear) dynamics. In addition, we find that a certain subset of these transformations, which result in utilities that have low opacity (analogous to having high signal to noise) but are not factored (analogous to not being incentive compatible), reliably improve performance over that arising with factored utilities. We also present a Taylor Series method for the fully general nonlinear case.

Wolpert, David H.↗

A New Gold Mine? Achieving HVAC Energy Efficiency Through a System Metric

Washington State's Commercial Energy Code adopted a new energy metric called HVAC Total System Performance Ratio (TSPR) in 2019, a first in the codes world to regulate HVAC system efficiency. TSPR is a ratio of annual heating and cooling loads to the annual carbon emissions associated with the energy consumed by the HVAC system. TSPR provides a performance-based solution to evaluate and improve the overall HVAC design. The TSPR metric and its companion calculation tool were developed by Pacific Northwest National Laboratory (PNNL) with support from U.S. Department of Energy (DOE), Northwest Energy Efficiency Alliance (NEEA) and the City of Seattle. The new metric represents a significant shift in how HVAC design will meet code requirements. Utility programs can also leverage TSPR as a measure to determine energy savings and incentive amounts for HVAC retrofits. This paper describes the efforts by NEEA and its collaborators to prepare the market for TSPR adoption in code. This paper provides the pilot projects led by University of Washington Integrated Design Lab (IDL) to understand potential issues that could be faced by early adopters. This paper also covers how training and outreach provide engagement opportunities that can streamline code compliance, help address issues faced by early adopters and promote participation in utility programs. As Washington State works on the goals of 70% energy reduction and zero fossil-fuel greenhouse gas emission homes and buildings by the year 2031 , system level performance metrics will likely become increasingly more necessary and prevalent. This paper concludes that the HVAC TSPR requirement helps familiarize the HVAC industry with this approach and helps Washington achieve its long-term goals.

Liu, Bing↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predicting the Impact of Utility Lighting Rebate Programs on Promoting Industrial Energy Efficiency: A Machine Learning Approach

Implementation costs are a major factor in manufacturers’ decisions to invest in energy-efficient technologies. Emerging technologies in lighting systems, however, typically require small investment costs and offer short, simple payback periods, due, in part, to federal, state, and utility incentive programs. Recently, however, certain state and federal mandates have reduced the support for and efficacy of electricity utility incentivizing programs. To determine the impact of such support programs, this study examined historical data regarding lighting retrofit savings, implementation costs, and utility rebates gathered from 13 years of industrial energy audits by a U.S. Department of Energy Industrial Assessment Center in a midwestern state. It uses a machine learning approach to evaluate the industrial energy and cost-saving opportunities that may have been lost due to decisions attributable to legislative mandates, utility policies, and manufacturers’ calculations and to evaluate the potential effect of lighting rebates on manufacturers’ decisions to implement industrial energy-efficient lighting retrofits. The results indicate that the decision not to implement lighting energy efficiency recommendations resulted in a loss of more than USD800,000 in potential rebates by industries during the study period and that the implementation of lighting energy assessment recommendations could have increased by about 50% if electric utility rebates had been available. These findings can help industries evaluate the benefits of implementing lighting efficiency improvements, and help utilities determine feasible lighting retrofit rebate values for incentivizing such changes by the industries they serve.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economic Case for Replacing High-Emitting Peaker Plants with Fuel Cells for Automotive Applications

The identification of clean and cost-effective solutions to replace high-emitting peaker plants and support a just transition is a challenge faced by utilities across the US today. However, falling costs of hydrogen production as well as the widespread availability of fuel cells for automotive applications have made them an attractive option for a zero-emission peak power supply. This study evaluates the techno-economics, operation, and environmental justice impacts of siting a peaker plant based on fuel cells for automotive applications through the lens of the existing Intermountain Power Plant, in order to supply peak power to the Los Angeles basin. Compared to the fossil fuel-fired peakers in operation today, the fuel cell peaker would be lower-cost up to a 17% capacity factor with Inflation Reduction Act incentives while also reducing air pollution in environmental justice communities. With corresponding transmission upgrades, the Intermountain site could host up to a 5 GW fuel cell peaker in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Impinging Stream Vortex Chamber Concepts for Liquid Rocket Engine Applications

To pursue technology developments for future launch vehicles, NASA/Marshall Space Flight Center (MSFC) is examining vortex chamber concepts for liquid rocket engine applications. Past studies indicated that the vortex chamber schemes potentially have a number of advantages over conventional chamber methods. Due to the nature of the vortex flow, relatively cooler propellant streams tend to flow along the chamber wall. Hence, the thruster chamber can be operated without the need of any cooling techniques. This vortex flow also creates strong turbulence, which promotes the propellant mixing process. Consequently, the subject chamber concepts not only offer system simplicity, but also enhance the combustion performance. Test results have shown that chamber performance is markedly high even at a low chamber length-to-diameter ratio (LD). This incentive can be translated to a convenience in the thrust chamber packaging. Variations of the vortex chamber concepts have been introduced in the past few decades. These investigations include an ongoing work at Orbital Technologies Corporation (ORBITEC). By injecting the oxidizer tangentially at the chamber convergence and fuel axially at the chamber head end, Knuth et al. were able to keep the wall relatively cold. A recent investigation of the low L/D vortex chamber concept for gel propellants was conducted by Michaels. He used both triplet (two oxidizer orifices and one fuel orifice) and unlike impinging schemes to inject propellants tangentially along the chamber wall. Michaels called the subject injection scheme an Impinging Stream Vortex Chamber (ISVC). His preliminary tests showed that high performance, with an Isp efficiency of 9295, can be obtained. MSFC and the U. S. Army are jointly investigating an application of the ISVC concept for the cryogenic oxygen/hydrocarbon propellant system. This vortex chamber concept is currently tested with gel propellants at AMCOM at Redstone Arsenal, Alabama. A version of this concept for the liquid oxygen (LOX) hydrocarbon fuel (RP-1) system has been derived from the one for the gel propellant. An unlike impinging injector was employed to deliver the propellants to the chamber. MSFC is also conducting an alternative injection scheme, called the chasing injector, associated with this vortex chamber concept. In this injection technique, both propellant jets and their impingement point are in the same chamber cross-sectional plane. Long duration tests (approximately up to 15 seconds) will be conducted on the ISVC to study the thermal effects. This paper will report the progress of the subject efforts at NASA Marshall Space Flight Center. Thrust chamber performance and thermal wall compatibility will be evaluated. The chamber pressures, wall temperatures, and thrust will be measured as appropriate. The test data will be used to validate CFD models, which, in turn, will be used to design the optimum vortex chambers. Measurements in the previous tests showed that the chamber pressures vary significantly with radius. This is due to the existence of the vortices in the chamber flow field. Hence, the combustion efficiency may not be easily determined from chamber pressure. For this project, measured thrust data will be collected. The performance comparison will be in terms of specific impulse efficiencies. In addition to the thrust measurements, several pressure and temperature readings at various locations on the chamber head faceplate and the chamber wall will be made. The first injector and chamber were designed and fabricated based on the available data and experience gained during gel propellant system tests by the U.S. Army. The alternate injector for the ISVC was also fabricated. Hot-fire tests of the vortex chamber are about to start and are expected to complete in February of 2003 at the TS115 facility of MSFC.