Engineering PapersSearch

SEARCH · Engineering Papers

Results for “imaging diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Science & Technology Review: April/May 2026 R&D 100 Winners Issue

At Lawrence Livermore National Laboratory, we focus on science and technology research to ensure our nation’s security. We also apply that expertise to solve other important national problems in energy, bioscience, and the environment. Science & Technology Review is published eight times a year to communicate, to a broad audience, the Laboratory’s scientific and technological accomplishments in fulfilling its primary missions. The publication’s goal is to help readers understand these accomplishments and appreciate their value to the individual citizen, the nation, and the world. Each year, the R&D 100 Awards recognize the top 100 innovations from a pool of international entries. Technologies developed at Lawrence Livermore earned four 2025 R&D 100 Awards, raising the Laboratory’s total to 186. A series of articles beginning on p. 4 describes each winning innovation: monolithic telescopes, the flexible imaging diffraction diagnostic for laser experiments, the in-air drop encapsulation apparatus, and the metaoptics-enabled large-scale 3D nanolithography platform.

36 MATERIALS SCIENCE

Doppler instrumentation for measuring blood velocity and flow

Doppler ultrasonic blood flowmeters are reviewed in detail. The importance of measurement accuracy for transcutaneous flowmeters and their clinical application is stressed. Doppler imaging was combined with conventional pulse echo imaging, and diagnostic information was extracted from flow signals. The range and extent of applications of Doppler instruments was also presented.

Gill, R. W.

A simulation and diagnostic study of water vapor image dry bands

Limited Area Mesoscale Prediction System model simulation and a special 3-hr radiosonde data set were used to investigate warm bands in the 6.7-micron water-vapor satellite imagery on March 6-7, 1982. It was found that the model reproduces major characteristics of the observed blackbody temperature, T(B), field. A 'development' dry image feature was found to occur in conjunction with an upper level shortwave trough, and an 'advective' feature was found associated with a polar jet streak. Both model and observed T(B) features were associated with vorticity maxima.

Muller, Bradley M.

Rocket engine plume diagnostics using video digitization and image processing - Analysis of start-up

Video digitization techniques have been developed to analyze the exhaust plume of the Space Shuttle Main Engine. Temporal averaging and a frame-by-frame analysis provide data used to evaluate the capabilities of image processing techniques for use as measurement tools. Capabilities include the determination of the necessary time requirement for the Mach disk to obtain a fully-developed state. Other results show the Mach disk tracks the nozzle for short time intervals, and that dominate frequencies exist for the nozzle and Mach disk movement.

Disimile, P. J.

The Ultra High Resolution XUV Spectroheliograph. II - Predicted performance

The phenomena to be studied with the Ultra-High Resolution XUV Spectroheliograph (UHRXS) which will be included into the instrumental load of the Space Station Freedom are discussed together with the characteristics of the nine multilayer Ritchey-Chretien telescopes constituting the UHRXS system. The telescopes will cover a spectral range from about 70 A to about 300 A. Each telescope will be able to isolate emission line multiplets excited over a narrow temperature range, providing images of diagnostic quality covering structures in the solar atmosphere ranging from T of about 50,000 K to 30,000,000 K. One of the nine UHRXS telescopes is configured as a coronagraph to allow observations to 6 solar radii beyond the solar limb. The paper presents an analysis of the expected sensitivity and resolving power of the UHRXS telescopes, and the diagnostic response of the various UHRXS instruments to structures in the solar atmosphere between 10,000 K and 100,000,000 K.

Walker, Arthur B. C., Jr.

Space medicine - Answering the challenge

The development of Space Station Freedom (SSF) Health Maintenance Facility (HMF) is discussed. Attention is given to HMF subsystems; the diagnostic radiological imaging system; the physician instruments; the pharmacy and central supply; the Fluid Therapy Subsystem; the restraints to be used for medical procedures; and the Safe Haven mode, which is a mode of station operation in which it is assumed that the HMF has been lost and the medical needs must be provided by the emergency medical equipment and supplies located in the Portable Emergency Provisions. Special attention is given to the pharmaceutical issues involved, including such as the product selection, oral medications, injectable medications, the effect of exposing medications to high vacuum, and the product shelf life.

Lloyd, Charles W.

Inferior vena caval masses identified by echocardiography

The most common cause of an inferior vena caval mass is renal cell carcinoma that extends through the lumen, occurring in 47 of 62 patients (85%). Detection of an inferior vena caval mass affects the surgical approach requiring cardiopulmonary bypass for resection when the mass extends to the heart.

NASA Discipline Cardiopulmonary

Fiber-Based Multi-Resolution Imaging and Multidimensional X-ray Diagnostics for Ejecta Dynamics in Plume Surface Interactions

The interaction of a rocket exhaust plume with a particulate-laden surface creates a complex, multiphase flow field that can destabilize the vehicle and damage nearby equipment. This study investigates two methods for capturing the particulate dynamics of plume-surface interaction (PSI): optical fiber-based multi-resolution Mie scattering and multi-dimensional X-ray radiography. Mie scattering was used to track PSI-interacted particles, trace their paths, and measure velocities. While effective for the jet periphery and early PSI stages, the technique becomes limited as the scattering cross-section increases over time due to particle displacement from the soil bed, causing the core to become optically dense and appear as a luminous, opaque region. To address this, X-ray radiography was explored as a complementary method for visualizing the optically dense core. PSI experiments were conducted with both reacting and non-reacting jets to evaluate these approaches across a range of optical and flow parameters. The results demonstrated the capability of the fiber-based multi-resolution imaging system to capture simultaneous fields of view at varying magnifications (1x, 2x, 4x), and the ability of X-ray imaging to penetrate the optically dense plume, revealing flow structures that would otherwise be obscured in scattering-based methods. Data were collected for various PSI parameters, including three different heights above the surface, to analyze the ejecta properties and the plume’s temporal evolution. These results provide the first imaging strategy capable of resolving flow structures over a wide spatial dynamic range while also offering the first visualization of the optically dense core.

Ejecta

X-ray phase-contrast imaging of strong shocks on OMEGA EP

The ongoing improvement in laser technology and target fabrication is opening new possibilities for diagnostic development. An example is x-ray phase-contrast imaging (XPCI), which serves as an advanced x-ray imaging diagnostic in laser-driven experiments. In this work, we present the results of the XPCI platform that was developed at the OMEGA EP Laser-Facility to study multi-Mbar single and double shocks produced using a kilojoule laser driver. Two-dimensional radiation-hydrodynamic simulations agree well with the shock progression and the spherical curvature of the shock fronts. It is demonstrated that XPCI is an excellent method to determine with high accuracy the front position of a trailing shock wave propagating through an expanding CH plasma that was heated by a precursor Mbar shock wave. Furthermore, the interaction between the rarefaction wave and the shock wave results in a clear signature in the radiograph that is well reproduced by radiation-hydrodynamic simulations.

47 OTHER INSTRUMENTATION

Polarization-separated double-imaging spectroscopy for weakly-ionized plasma diagnostics

Laser Thomson scattering, which provides thermal properties of electrons, has been extensively utilized in plasma diagnostics. However, being a non-resonant linear light scattering technique, it often encounters several challenges in weakly-ionized plasma diagnostics due to spectral overlap with different scatterings induced from other existing species, including Mie, Rayleigh, and rotational Raman scatterings. To address this challenge, we propose an imaging spectroscopy technique, polarization-separated double-imaging spectroscopy (PoDIS), which selectively separates specific scatterings based on their polarization characteristics. Using an atmospheric plasma jet as a plasma source for demonstration, we show that PoDIS can effectively separate rotational Raman and Thomson scatterings from a superimposed spectrum without prior knowledge or assumptions about the thermal properties of neutrals or electrons. This separation enables independent fitting of the rotational Raman and Thomson scattering spectra, allowing for precise determination of the thermal properties of neutral particles and electrons separately.

Bak, Junhwi [Texas A&M University, College Station

Image-Capture Devices Extend Medicine's Reach

Johnson Space Center, Henry Ford Hospital in Detroit, and Houston-based Wyle Laboratories collaborated on NASA's Advanced Diagnostic Ultrasound in Microgravity (ADUM) experiment, which developed revolutionary medical ultrasound diagnostic techniques for long-distance use. Mediphan, a Canadian company with U.S. operations in Springfield, New Jersey drew on NASA expertise to create frame-grabber and data archiving technology that enables ultrasound users with minimal training to send diagnostic-quality ultrasound images and video to medical professionals via the Internet in near real time allowing patients as varied as professional athletes, Olympians, and mountain climbers to receive medical attention as soon as it is needed.

Source record

Focal-Plane Imaging of Crossed Beams in Nonlinear Optics Experiments

An application of focal-plane imaging that can be used as a real time diagnostic of beam crossing in various optical techniques is reported. We discuss two specific versions and demonstrate the capability of maximizing system performance with an example in a combined dual-pump coherent anti-Stokes Raman scattering interferometric Rayleigh scattering experiment (CARS-IRS). We find that this imaging diagnostic significantly reduces beam alignment time and loss of CARS-IRS signals due to inadvertent misalignments.

Bivolaru, Daniel

Contrast and harmonic imaging improves accuracy and efficiency of novice readers for dobutamine stress echocardiography

BACKGROUND: Newer contrast agents as well as tissue harmonic imaging enhance left ventricular (LV) endocardial border delineation, and therefore, improve LV wall-motion analysis. Interpretation of dobutamine stress echocardiography is observer-dependent and requires experience. This study was performed to evaluate whether these new imaging modalities would improve endocardial visualization and enhance accuracy and efficiency of the inexperienced reader interpreting dobutamine stress echocardiography. METHODS AND RESULTS: Twenty-nine consecutive patients with known or suspected coronary artery disease underwent dobutamine stress echocardiography. Both fundamental (2.5 MHZ) and harmonic (1.7 and 3.5 MHZ) mode images were obtained in four standard views at rest and at peak stress during a standard dobutamine infusion stress protocol. Following the noncontrast images, Optison was administered intravenously in bolus (0.5-3.0 ml), and fundamental and harmonic images were obtained. The dobutamine echocardiography studies were reviewed by one experienced and one inexperienced echocardiographer. LV segments were graded for image quality and function. Time for interpretation also was recorded. Contrast with harmonic imaging improved the diagnostic concordance of the novice reader to the expert reader by 7.1%, 7.5%, and 12.6% (P < 0.001) as compared with harmonic imaging, fundamental imaging, and fundamental imaging with contrast, respectively. For the novice reader, reading time was reduced by 47%, 55%, and 58% (P < 0.005) as compared with the time needed for fundamental, fundamental contrast, and harmonic modes, respectively. With harmonic imaging, the image quality score was 4.6% higher (P < 0.001) than for fundamental imaging. Image quality scores were not significantly different for noncontrast and contrast images. CONCLUSION: Harmonic imaging with contrast significantly improves the accuracy and efficiency of the novice dobutamine stress echocardiography reader. The use of harmonic imaging reduces the frequency of nondiagnostic wall segments.

Non-NASA Center

Retrieval of Temperature and Species Distributions from Multispectral Image Data of Surface Flame Spread in Microgravity

Weight, size, and power constraints severely limit the ability of researchers to fully characterize temperature and species distributions in microgravity combustion experiments. A powerful diagnostic technique, infrared imaging spectrometry, has the potential to address the need for temperature and species distribution measurements in microgravity experiments. An infrared spectrum imaged along a line-of-sight contains information on the temperature and species distribution in the imaged path. With multiple lines-of-sight and approximate knowledge of the geometry of the combustion flowfield, a three-dimensional distribution of temperature and species can be obtained from one hyperspectral image of a flame. While infrared imaging spectrometers exist for collecting hyperspectral imagery, the remaining challenge is retrieving the temperature and species information from this data. An initial version of an infrared analysis software package, called CAMEO (Combustion Analysis Model et Optimizer), has been developed for retrieving temperature and species distributions from hyperspectral imaging data of combustion flowfields. CAMEO has been applied to the analysis of multispectral imaging data of flame spread over a PMMA surface in microgravity that was acquired in the DARTFire program. In the next section of this paper, a description of CAMEO and its operation is presented, followed by the results of the analysis of microgravity flame spread data.

Annen, K. D.

Smart Ultrasound Remote Guidance Experiment (SURGE) Preliminary Findings

To date, diagnostic quality ultrasound images were obtained aboard the International Space Station (ISS) using the ultrasound of the Human Research Facility (HRF) rack in the Laboratory module. Through the Advanced Diagnostic Ultrasound in Microgravity (ADUM) and the Braslet-M Occlusion Cuffs (BRASLET SDTO) studies, non-expert ultrasound operators aboard the ISS have performed cardiac, thoracic, abdominal, vascular, ocular, and musculoskeletal ultrasound assessments using remote guidance from ground-based ultrasound experts. With exploration class missions to the lunar and Martian surfaces on the horizon, crew medical officers will necessarily need to operate with greater autonomy given communication delays (round trip times of up to 5 seconds for the Moon and 90 minutes for Mars) and longer periods of communication blackouts (due to orbital constraints of communication assets). The SURGE project explored the feasibility and training requirements of having non-expert ultrasound operators perform autonomous ultrasound assessments in a simulated exploration mission outpost. The project aimed to identify experience, training, and human factors requirements for crew medical officers to perform autonomous ultrasonography. All of these aims pertained to the following risks from the NASA Bioastronautics Road Map: 1) Risk 18: Major Illness and Trauna; 2) Risk 20) Ambulatory Care; 3) Risk 22: Medical Informatics, Technologies, and Support Systems; and 4) Risk 23: Medical Skill Training and Maintenance.

Hurst, Victor