Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A coded aperture with sub-mean-free-path thickness for implosion geometry imaging on ICF and IFE experiments

Inertial confinement fusion and inertial fusion energy experiments diagnose the geometry of the fusion region through imaging of the neutrons released through fusion reactions. Pinhole arrays typically used for such imaging require thick substrates to obtain high contrast along with a small pinhole diameter to obtain high resolution capability, resulting in pinholes that have large aspect ratios. This leads to expensive pinhole arrays that have small solid angles and are difficult to align. Here, we propose a coded aperture with scatter and partial attenuation (CASPA) for fusion neutron imaging that relaxes the thick substrate requirement for good image contrast. These coded apertures are expected to scale to larger solid angles and are easier to align without sacrificing imaging resolution or throughput. We use Monte Carlo simulations (Geant4) to explore a coded aperture design to measure neutron implosion asymmetries on fusion experiments at the National Ignition Facility (NIF) and discuss the viability of this technique, matching the current nominal resolution of 10 µm. The results show that a 10 mm thick tungsten CASPA can image NIF implosions with neutron yields above 10 14 with quality comparable to unprocessed data from a current NIF neutron imaging aperture. Furthermore, this CASPA substrate is 20 times thinner than the current aperture arrays for fusion neutron imaging and less than one mean free-path of 14.1 MeV neutrons through the substrate. Since the resolution, solid angle, and throughput are decoupled in coded aperture imaging, the resolution and solid angle achievable with future designs will be limited primarily by manufacturing capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polarimetric Geometric Modeling for mm-VLBI Observations of Black Holes

The Event Horizon Telescope (EHT) is a millimeter very long baseline interferometry (VLBI) array that has imaged the apparent shadows of the supermassive black holes M87* and Sagittarius A*. Polarimetric data from these observations contain a wealth of information on the black hole and accretion flow properties. In this work, we develop polarimetric geometric modeling methods for mm-VLBI data, focusing on approaches that fit data products with differing degrees of invariance to broad classes of calibration errors. We establish a fitting procedure using a polarimetric “m-ring” model to approximate the image structure near a black hole. By fitting this model to synthetic EHT data from general relativistic magnetohydrodynamic models, we show that the linear and circular polarization structure can be successfully approximated with relatively few model parameters. We then fit this model to EHT observations of M87* taken in 2017. In total intensity and linear polarization, the m-ring fits are consistent with previous results from imaging methods. In circular polarization, the m-ring fits indicate the presence of event-horizon-scale circular polarization structure, with a persistent dipolar asymmetry and orientation across several days. The same structure was recovered independently of observing band, used data products, and model assumptions. Despite this broad agreement, imaging methods do not produce similarly consistent results. Our circular polarization results, which imposed additional assumptions on the source structure, should thus be interpreted with some caution. Polarimetric geometric modeling provides a useful and powerful method to constrain the properties of horizon-scale polarized emission, particularly for sparse arrays like the EHT.

79 ASTRONOMY AND ASTROPHYSICS↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

A time-resolved imaging system for the diagnosis of x-ray self-emission in high energy density physics experiments

A diagnostic capable of recording spatially and temporally resolved x-ray self-emission data was developed to characterize experiments on the MAGPIE pulsed-power generator. The diagnostic used two separate imaging systems: a pinhole imaging system with two-dimensional spatial resolution and a slit imaging system with one-dimensional spatial resolution. The two-dimensional imaging system imaged light onto the image plate. The one-dimensional imaging system imaged light onto the same piece of image plate and a linear array of silicon photodiodes. This design allowed the cross-comparison of different images, allowing a picture of the spatial and temporal distribution of x-ray self-emission to be established. The design was tested in a series of pulsed-power-driven magnetic-reconnection experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallelized telecom quantum networking with an ytterbium-171 atom array

The integration of quantum computers and sensors into a quantum network enables new capabilities in quantum information science. Most networks with atom-like qubits operate at visible or near-ultraviolet wavelengths and require conversion to the telecom band for long-distance communication, which reduces efficiency and potentially introduces noise. In this article we report high-fidelity entanglement between ytterbium-171 atoms and optical photons generated directly in the telecommunication band, where fibre loss is low. The nuclear spin of the atom is entangled with a single photon in the time-bin basis, yielding a high atom-measurement-corrected atom–photon Bell state fidelity. This can be further improved by addressing photon measurement errors. By imaging the atom array onto an optical fibre array, we also implement a parallelized networking protocol that can increase the remote entanglement rate proportionately with the number of channels. We also preserve coherence on a memory qubit during operations on communication qubits. These results support the integration of atomic systems into scalable quantum networks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Internal structure of the San Jacinto fault zone at the Ramona Reservation, north of Anza, California, from dense array seismic data

SUMMARY We image the internal structure of the San Jacinto fault zone (SJFZ) near Anza, California, with seismic data recorded by two dense arrays (RA and RR) from ∼42 000 local and ∼180 teleseismic events occurring between 2012 and 2017. The RA linear array has short aperture (∼470 m long with 12 strong motion sensors) and recorded for the entire analysed time window, whereas the RR is a large three-component nodal array (97 geophones across a ∼2.4 km × 1.4 km area) that operated for about a month in September–October 2016. The SJFZ at the site contains three near-parallel surface traces F1, F2 and F3 from SW to NE that have accommodated several Mw > 6 earthquakes in the past 15 000 yr. Waveform changes in the fault normal direction indicate structural discontinuities that are consistent with the three fault surface traces. Relative slowness from local events and delay time analysis of teleseismic arrivals in the fault normal direction suggest a slower SW side than the NE with a core damage zone between F1 and F2. This core damage zone causes ∼0.05 s delay at stations RR26–31 in the teleseismic P arrivals compared with the SW-most station, and generates both P- and S-type fault zone trapped waves. Inversion of S trapped waves indicates the core damaged structure is ∼100 m wide, ∼4 km deep with a Q value of ∼20 and 40 per cent S-wave velocity reduction compared with bounding rocks. Fault zone head waves observed at stations SW of F3 indicate a local bimaterial interface that separates the locally faster NE block from the broad damage zone in the SW at shallow depth and merges with a deep interface that separates the regionally faster NE block from rocks to the SW with slower velocities at greater depth. The multiscale structural components observed at the site are related to the geological and earthquake rupture history at the site, and provide important information on the preferred NW propagation of earthquake ruptures on the San Jacinto fault.

Geochemistry & Geophysics↗

Fraction of broad absorption line quasars in different radio morphologies

ABSTRACT In this study, we investigated the orientation model of Broad Absorption Line (BAL) quasars using a sample of sources that are common in Sloan Digital Sky Survey (SDSS) Data Release (DR)-16 quasar catalogue and Very Large Array (VLA)-Faint Images of the Radio Sky at Twenty Centimeters (FIRST) survey. Using the radio cut-out images from the FIRST survey, we first designed a deep-learning model using convolutional neural networks (CNN) to classify the quasar radio morphologies into the core-only, young jet, single lobe, or triples. These radio morphologies are further sub-classified into core-dominated and lobe-dominated sources. The CNN models can classify the sources with a high precision of >98 ${{\ \rm per\ cent}}$ for all the morphological sub-classes. The average BAL fraction in the resolved core, core-dominated, and lobe-dominated quasars are consistent with the BAL fraction inferred from radio and infrared surveys. We also present the distribution of BAL quasars as a function of quasar orientation by using the radio core-dominance as an orientation indicator. A similar analysis is performed for HiBALs, LoBALs, and FeLoBALs. All the radio morphological sub-classes and BAL sub-classes show an increase in BAL fraction at high orientation angles of the jets with respect to the line of sight. Our analysis suggests that BAL quasars are more likely to be found in viewing angles close to the equatorial plane of the quasar. However, a pure orientation model is inadequate, and a combination of orientation and evolution is probably the best way to explain the complete BAL phenomena.

79 ASTRONOMY AND ASTROPHYSICS↗

First flight performance of the Micro-X microcalorimeter X-ray sounding rocket

The flight of the Micro-X sounding rocket on July 22, 2018, marked the first operation of transition-edge sensors and their superconducting quantum interference device readouts in space. Here, the instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia A supernova remnant. Although a rocket pointing malfunction led to no time on-target, data from the flight were used to evaluate the performance of the instrument and demonstrate the flight viability of the payload. The instrument successfully achieved a stable cryogenic environment, executed all flight operations, and observed X-rays from the on-board calibration source. The flight environment did not significantly affect the performance of the detectors compared with ground operation. The flight provided an invaluable test of the impact of external magnetic fields and the instrument configuration on detector performance. This flight provides a milestone in the flight readiness of these detector and readout technologies, both of which have been selected for future X-ray observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-resolved detectors for quantum ghost imaging

Quantum ghost imaging is a method that utilizes the correlated detection of two photons to generate an image. One photon is detected by an imaging sensor and the other by a single-element bucket detector. The selection of the imaging sensor and its capabilities relative to the bucket detector impact the quality of the ghost images. This work examines a SPAD array and a photocathode detector as imaging sensors for quantum ghost imaging. We discuss how to achieve optimal images using these two technologies. We also demonstrate that these devices are able to generate ghost images at 1Hz frame rates, expanding the technique to biologically relevant time scales.

36 MATERIALS SCIENCE↗

Stronger field-emission science via coupling novel nanoscale imaging techniques

We implemented a vacuum field emission electron microscope (FEM) using the electron optics of a low-energy /photoemission electron microscope (LEEM/PEEM). Historically, there have been other FEM hardware platforms, and the distinctive feature of our method is that it integrates with the LEEM/PEEM and associated techniques, enabling a powerful multi-capability toolset for studying fundamental materials properties underpinning field emission (FE) and vacuum arc initiation. Typically, LEEM is used to image surface structure, which influences both work function and electric field distribution near a surface, while PEEM is used to map photoelectric work function across a surface. Our FEM adds the capability for spatially-correlated coincident-site measurements of FE currents to go-along with structure and work function. LEEM, PEEM, and our FEM implementation achieve nanoscale spatial resolution relevant for materials studies in nanoscience/engineering. Our approach requires a straightforward calibration of the electron optics to enable focused FEM imaging under intentional electric field variation. We demonstrate the FEM approach by imaging field emitter arrays relevant for vacuum nanoelectronics. We demonstrate submicron spatial resolution and dynamic measurement of FE versus applied electric field. We anticipate this capability will enable fundamental structure-function studies of FE and arc initiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft X-ray measurements of transport and MHD activity in the core and edge NSTX plasma (Final Technical Report)

A comprehensive suite of innovative diagnostic instrumentation and techniques has been developed by the Johns Hopkins collaboration for measurements of transport and MHD activity in the core and edge of the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory (PPPL). These include ultrafast multi-energy poloidal soft X-ray arrays, high spatial resolution multi-energy tangential soft X-ray arrays, high spectral resolution transmission grating imaging VUV spectrometers and ultrafast bolometric arrays, which measure over a broad range of spatial, spectral, and temporal scales the emission from ohmic, RF, and beam driven NSTX plasmas. The instrumentation was designed to fulfill the specific measurement needs of the Spherical Torus (ST) magnetic fusion concept and is accompanied by a comprehensive set of numerical tools for data analysis and modeling, aimed at determining as many as possible plasma parameters and at extracting as much as possible physics information from NSTX experiments. The Johns Hopkins diagnostics have been and continue to be instrumental for essentially all the NSTX experiments. In addition, our own research and experiments using these diagnostics has led over the years to fundamental conclusions for the ST fusion physics, such as the establishment of near neoclassical impurity transport in the NSTX core and edge plasma, and the critical role of the Global Alfven Eigenmode (GAE) MHD activity for the ST core electron thermal transport. The Johns Hopkins Diagnostics continue to be operational on the upgraded NSTX-U and will provide key plasma information in its upcoming high field, current and power experimental campaigns. The present report summarizes the main technical characteristics and measurement capabilities of the diagnostic instrumentation and methods developed within our research and describes a key physics result achieved during this research. Success in our research was made possible also by the excellent support and cooperation of the NSTX research team and of PPPL researchers, who are warmly acknowledged here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing electron-collecting CdTe for use in a 77 ns burst-rate imager

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

36 MATERIALS SCIENCE↗

Task-specific sensor optical designs

A method and system architecture for designing a compressive sensing matrix for machine learning includes receiving an image associated with a classification task and; generating a sensing matrix. The sensing matrix includes an array of nonzero elements of the image. A prism array of prism elements is in communication with the sensing matrix. A row of values corresponding with an input angle of the prism array is mapped to a respective column corresponding with a detector. Then the detector detects light refracted at an output angle dictated by the physical shape of the prism element. A physical model of the detector is fabricated and generates a compressed representation of the image. A machine learning classification algorithm is applied to the compressed representation of the image and generates an optimized non-invertible final determination of the image.

Birch, Gabriel Carlisle↗

Temporal light modulation: A phantom array visibility measure

At temporal light modulation (TLM) frequencies between 80 Hz and 20 000 Hz observers may perceive a series of repeated images called the phantom array effect (PAE) when they move their eyes in large saccades across a modulating light source or across a scene lit by the modulating light source. To date, there is no well-established measure for quantifying PAE visibility, but there is growing awareness of the need for one among design professionals and sensitive populations. This paper documents a new measure, the phantom array visibility measure (PAVM), which is based on the results of recent human factors experiments. The measure follows the mathematical underpinning used by the flicker visibility measure and the stroboscopic visibility measure, where the time-domain TLM waveform is converted into its Fourier frequency components; each component is evaluated through a threshold curve of modulation depth, then summed through an equation employing a Minkowski exponent. This scales the PAVM so that a value of 1 indicates a waveform at a threshold visibility in the conditions of the underlying experiment.

Tan, J.↗

Evaluation of sequence tracking methods for Compton cameras based on CdZnTe arrays

In this study, the performance of sequence tracking methods for multiple interaction events in specific CdZnTe Compton imagers was evaluated using Monte Carlo simulations. The Compton imager consisted of a 6 × 6 array of virtual Frisch-grid CZT crystals, where the dimensions of each crystal were 5 × 5 × 12 mm 3 . The sequence tracking methods for another Compton imager that consists of two identical CZT crystals arrays were also evaluated. When 662 keV radiation was incident on the detectors, the percentages of the correct sequences determined by the simple comparison and deterministic methods for two sequential interactions were identical (~80 %), while those evaluated using the minimum squared difference method (55-59 %) and Three Compton method (45-55 %) for three sequential interactions, differed from each other. The reconstructed images of a 662 keV point source detected using single and double arrays were evaluated based on their angular resolution and signal-to-noise ratio, and the results showed that the double arrays outperformed single arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Internal Structure of the Central Garlock Fault Zone From Ridgecrest Aftershocks Recorded by Dense Linear Seismic Arrays

Abstract We provide high‐resolution seismic imaging of the central Garlock fault using data recorded by two dense seismic arrays that cross the Ridgecrest rupture zone (B4) and the Garlock fault (A5). Analyses of fault zone head waves and P ‐wave delay times at array A5 show that the Garlock fault is a sharp bimaterial interface with P waves traveling ∼5% faster in the northern crustal block. The across‐fault velocity contrast agrees with regional tomography models and generates clear P ‐wave reflections in waveforms recorded by array B4. Kirchhoff migration of the reflected waves indicates a near‐vertical fault between 2 and 6 km depth. The P ‐wave delay times imply a ∼300‐m‐wide transition zone near the Garlock fault surface trace beneath array A5, offset to the side with faster velocities. The results provide important constraints for derivations of earthquake properties, simulations of ruptures and ground motion, and future imaging studies associated with the Garlock fault.

58 GEOSCIENCES↗