Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “images”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Fresnel zone plate point spread function approximation for zeroth order mitigation in millimetric field of view x-ray imaging

High spatial and temporal resolution x-ray radiography images are required at the National Ignition Facility (NIF) for high-energy density experiments. One technique that is in development to achieve the required resolution uses Fresnel zone plate (FZP) optics to image an object that is backlit by an x-ray source. The multiple FZP diffraction orders do not focus on the same plane, which increases the background and reduces the contrast. Understanding the point spread function of the different diffraction orders will allow the prediction of the expected background using simulations. We find that the two-dimensional point spread function of the FZP can be approximated by the addition of a sharp Gaussian with a disk. This allowed for the estimation of the background in NIF experimental images of Rayleigh–Taylor spikes and their interpretation. An alternative design of FZP is discussed to allow the inclusion of a zeroth order blocker to reduce the background.

Do, A. (ORCID:0000000174372147)↗

High-resolution ptychographic imaging enabled by high-speed multi-pass scanning

As a coherent diffraction imaging technique, ptychography provides high-spatial resolution beyond Rayleigh’s criterion of the focusing optics, but it is also sensitively affected by the decoherence coming from the spatial and temporal variations in the experiment. Here we show that high-speed ptychographic data acquisition with short exposure can effectively reduce the impact from experimental variations. To reach a cumulative dose required for a given resolution, we further demonstrate that a continuous multi-pass scan via high-speed ptychography can achieve high-resolution imaging. This low-dose scan strategy is shown to be more dose-efficient, and has potential for radiation-sensitive sample studies and time-resolved imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward inverse backscatter absorption gas imaging: imaging a dry gas plume with ambient H 2 O absorption

This paper introduces inverse backscatter absorption gas imaging (iBAGI), a transparent gas imaging technique based on absorption spectroscopy of gases naturally present in ambient air being displaced by transparent gases. We demonstrate reconstruction of a 2-D image of a dry gas plume by measuring light of a raster-scanned diode laser tuned to an absorption line of atmospheric H 2 O. We quantify the performance depending on the distance to the backdrop and show that the key transmission metric is independent of absorption path length. We conclude with an outlook toward calibration-free, single-ended iBAGI using scattering from low-reflectivity backdrops.

Klug, Joseph C.↗

Combining hyperspectral imaging and micro-X-ray fluorescence imaging methods for ultra-high-resolution biogeochemical analysis

Current non-destructive methods for high-resolution geochemical imaging open new avenues for high-resolution paleoenvironmental research. We discuss how two of these methods, hyperspectral imaging and micro-X-ray fluorescence imaging, can be combined for organic and inorganic geochemical analyses at a micrometer scale.

Zander, Paul [Lawrence Livermore National Laborato↗

Supplementary material for manuscript: Microcomputed X-ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives

This data contains the supplemental information that will be accessible to the public from the paper “Microcomputed X-ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives”. The data set contains the reconstructed slices for the 3D images of three different high explosives including: HMX-HTPB, PBX 9501 and PBX 9502. The data sets are folders of reconstructed tiffs showing the microstructure (crystals, binder, voids) and a segmented data set of each. Finally, a .gif movie is also present that plays the slices sequentially. The folders contain the voxel size information. See the manuscript for more details.

36 MATERIALS SCIENCE↗

A Uniform Analysis of Debris Disks with the Gemini Planet Imager. I. An Empirical Search for Perturbations from Planetary Companions in Polarized Light Images

The Gemini Planet Imager (GPI) has excelled in imaging debris disks in the near-infrared. The GPI Exoplanet Survey imaged 24 debris disks in polarized H-band light, while other programs observed half of these disks in polarized J and/or K1 bands. Using these data, we present a uniform analysis of the morphology of each disk to find asymmetries suggestive of perturbations, particularly those due to planet–disk interactions. The multiwavelength surface brightness, disk color, and geometry permit the identification of any asymmetries such as warps or disk offsets from the central star. We find that 19 of the disks in this sample exhibit asymmetries in surface brightness, disk color, disk geometry, or a combination of the three, suggesting that for this sample, perturbations, as seen in scattered light, are common. The relationship between these perturbations and potential planets in the system is discussed. We also explore correlations among stellar temperatures, ages, disk properties, and observed perturbations. We find significant trends between the vertical aspect ratio and the stellar temperature, disk radial extent, and the dust grain size distribution power law, q. We also confirm a trend between the disk color and stellar effective temperature, where the disk becomes increasingly red/neutral with increasing temperature. Such results have important implications for the evolution of debris disk systems around stars of various spectral types.

79 ASTRONOMY AND ASTROPHYSICS↗

Microscopy imaging device with advanced imaging properties

Systems, methods and devices are implemented for microscope imaging solutions. One embodiment of the present disclosure is directed toward an epifluorescence microscope. The microscope includes an image capture circuit including an array of optical sensor. An optical arrangement is configured to direct excitation light of less than about 1 mW to a target object in a field of view of that is at least 0.5 mm 2 and to direct epi-fluorescence emission caused by the excitation light to the array of optical sensors. The optical arrangement and array of optical sensors are each sufficiently close to the target object to provide at least 2.5 μm resolution for an image of the field of view.

Ghosh, Kunal↗

Microscopy imaging device with advanced imaging properties

Systems, methods and devices are implemented for microscope imaging solutions. One embodiment of the present disclosure is directed toward an epifluorescence microscope. The microscope includes an image capture circuit including an array of optical sensor. An optical arrangement is configured to direct excitation light of less than about 1 mW to a target object in a field of view of that is at least 0.5 mm2 and to direct epi-fluorescence emission caused by the excitation light to the array of optical sensors. The optical arrangement and array of optical sensors are each sufficiently close to the target object to provide at least 2.5 μm resolution for an image of the field of view.

Ghosh, Kunal↗

Systems, methods, and media for high dynamic range imaging using single-photon and conventional image sensor data

In accordance with some embodiments, systems, methods, and media for high dynamic range imaging using single-photon and conventional image sensor data are provided. In some embodiments, the system comprises: first detectors configured to detect a level of photons proportional to incident photon flux; second detectors configured to detect arrival of individual photons; a processor programmed to: receive, from the first detectors, first values indicative of photon flux from a scene with a first resolution; receive, from the second detectors, second values indicative of photon flux from the scene with a lower resolution; provide a first encoder of a trained machine learning model first flux values based on the first values, provide the second encoder of the model second flux values; receive, as output, values indicative of photon flux from the scene; and generate a high dynamic range image based on the third plurality of values.

Gutierrez Barragan, Felipe↗

The CLAS12 Ring Imaging Cherenkov Detector

A ring imaging Cherenkov (RICH) detector has been installed in the CLAS12 spectrometer at Jefferson Laboratory (JLab) to provide kaon identification in the momentum range between 3 GeV/c and 8 GeV/c. The detector adopts a hybrid optics solution with aerogel radiator, light planar and spherical mirrors, and highly segmented photon detectors. We report here on the design, construction, and initial performance of the RICH during the commissioning of the detector and the first physics data taking period

PID detectors↗

Photovoltaic Module Imaging for Hail Damage Assessment with Multi-Year Follow Up

Outdoor-aged photovoltaic modules that have experienced golf-ball sized hail are characterized by flash testing and photoluminescence, electroluminescence, thermal, and ultraviolet fluorescence imaging. These measurements were performed immediately after the hailstorm and then again after another two years and four years in the field. The modules originally experienced different ranges of hail damage with some having cracks on approximately half of the cells and some having few to no cracked cells. Flash testing shows that the hail-damaged modules with the most cracked cells have 3 to 4% less power than those with the least damage. After four more years in the outdoor climate of Golden, Colorado since the hailstorm, all of the modules still exhibit similar relative power and amounts of cell cracking, suggesting that the hail damage has only initially reduced power but has not yet increased the degradation rate.

electroluminescence↗

Investigation of near-field jet stability of a single-hole injector based on fast X-ray phase contrast imaging and image feature matching

Fuel spray is very effective in controlling the combustion process to improve engine performance and reduce emissions. Understanding the spray unstability during the injection process is of importance to improve the control of spray characteristics and engine operation. In this study, near-field biodiesel jets were recorded using fast X-ray phase contrast imaging and the flow features inside the jet were extracted using Speeded Up Robust Features (SURF) method. Here, the image similarity by feature matching was successfully used to represent the near-field jet stability. Based on the jet stability, an injection process can be divided into five stages: an unstable stage at needle opening, a partially stable transition stage at needle opening, a stable stage, a stable transition stage at needle closing and an unstable stage at needle closing. The ranges of needle lift for five stages were also determined. The jet unstability is highly related to the cavitation formation and gas purging process during needle opening. The variation of stable jet feature is dependent on the needle lift at needle closing. Higher needle lift for the similar jet feature at needle opening indicates a hydraulic delay compared to needle closing. Finally, the possible reasons of jet feature formation and feature detection used on the multi-hole injector are discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Chemical Imaging of Atmospheric Biomass Burning Particles from North American Wildfires

The effects of biomass burning aerosols (BBA) on radiative forcing and cloud formation depend on chemical composition and the internal structures of individual particles within smoke plumes. To improve our understanding of the chemical and physical properties of BBA emitted at different times of the day and their evolution during atmospheric aging, we conducted a study as a part of the Fire Influence on Regional to Global Environments and Air Quality field campaign. Particle samples were collected onboard a research aircraft from smoke plumes from a wildfire in eastern Oregon during late afternoon and nighttime flights on August 28, 2019. A time-resolved aerosol collector was used to collect samples on substrates for offline spectromicroscopic imaging to investigate the single-particle characteristics of BBA particles. Approximately 20,400 individual particles from 10 selected samples were analyzed using computer-controlled scanning electron microscopy coupled with energy-dispersive X-ray microanalysis, revealing their elemental composition, morphology, and viscosity. Elemental microanalysis indicated that aged potassium is likely found in the form of K 2 SO 4 , KNO 3 , and possible K-organic salts. Further chemical speciation and carbon bonding mapping within individual particles were conducted using synchrotron-based scanning transmission X-ray microscopy (STXM) coupled with near edge X-ray absorption fine structure (NEXAFS) spectroscopy. Real-time, water-soluble light absorption measurements were acquired using a particle-into-liquid sampler instrument coupled to a liquid waveguide capillary cell and total organic analyzer. In the late afternoon samples, 65% of the total particle number population consisted entirely of organic components, compared to 46% in the nighttime particles. These differences were attributed to discrepancies in composition at the time of emission and to the daytime condensation and accumulation of photochemically formed secondary organic material on existing BBA particles, a process that halts at night. Microscopy images indicated that particle viscosity was lower in the nighttime particles (<10 1 Pa·s), likely due to increased relative humidity and a higher contribution from hygroscopic inorganic components. The chemical heterogeneity of individual particles was quantified using STXM-derived mixing state parameters. The nature of carbon bonding within individual particles was inferred from the extent of carbon sp 2 hybridization derived from NEXAFS spectra. Average percentages of sp 2 hybridization range between 40% and 60%, with no noticeable differences between late afternoon and nighttime flights. These findings were compared with the online optical properties of both late afternoon and nighttime smoke plumes, providing valuable insights into the complex relationship between chemical composition and optical properties of BBA particles at different times of the day.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unimodal Imaging of Monovalent Metal-Chelator Complexes and Lipids by MALDI Imaging Mass Spectrometry

Careful regulation of monovalent metal ions (M + ) is necessary to maintain a functional cellular system. Of these ions, appropriate sodium (Na + ) and potassium (K + ) concentrations are particularly integral for electrochemical signaling, as well as the secondary transport of nutrients and waste. Dysregulation of M + homeostasis can disrupt these mechanisms, potentially influencing the metabolism of downstream biomolecules such as lipids. Thus, the relationship between M + abundances and related biomolecular distributions must be elucidated to better understand the physiology of healthy and disordered tissues. Traditional techniques for imaging biological metal distributions include SIMS, LA-ICP-MS, and XRF; however, these capabilities are limited to elemental analysis or the analysis of molecular fragments and must be paired with other modalities to visualize distributions of more complex biomolecules within the same or similar samples. Conversely, matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) is a powerful tool often used for mapping such biomolecular distributions, but current methods are unable to detect metals within tissue. This study illustrates a novel methodology that adds metal detection to the MALDI IMS repertoire through which the simultaneous detection of M + metals and lipids is achievable. Using a robotic sprayer for homogeneous application, on-tissue deposition of the chelator deferiprone (DEF) enables subsequent detection of the ionizable metal-chelator complex by MALDI without hindering lipid detection. Our work provides proof-of-concept data for the simultaneous detection of K + , Na + , and intact lipids using MALDI IMS.

59 BASIC BIOLOGICAL SCIENCES↗

4D Proxy Imaging of Fracture Dilation and Stress Shadowing Using Electrical Resistivity Tomography During High Pressure Injections into a Dense Rock Formation

Fluid flow through fractured rock systems is governed in large part by the distribution, interconnectivity, and size of fracture apertures. In-situ stress is one of the primary factors controlling fracture aperture, and one that is altered significantly during high-pressure fluid injections or extractions. Interactions between stress, pore pressure, aperture, and fluid flow can result in complex and evolving poroelastic behavior with significant implications regarding the predictability and risk of developing and managing deep subsurface reservoirs (geothermal, fossil energy, and geologic carbon sequestration). In saturated crystalline rocks, bulk electrical conductivity is highly sensitive to porosity, and therefore to fracture aperture size and distribution. We demonstrate the use of time-lapse 3D electrical resistivity tomography for remotely monitoring stress induced changes in aperture distribution during high pressure injections into a fractured rock system at a scale of tens of meters. Results reveal a complex and continuously evolving stress field involving aperture dilations in the natural fracture system and aperture contractions in adjacent zones of shadow stress. Results provide information about the spatiotemporal changes in the system behavior and point to the potential of electrical imaging for autonomously and remotely monitoring evolving stress conditions by proxy through changes in bulk electrical conductivity.

electrical resisitivity tomography, stress, 4D Tim↗