Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hydrogen mass transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Detection of CO J = 2 goes to 1 emission from the polar rings of NGC 2685 and NGC 4650A

We report the detection of the J = 2 goes to 1 (230 GHz) line of carbon monoxide in the polar rings of the galaxies NGC 2685 and NGC 4650A, and we use the results in a simple analysis of the composition of the neutral interstellar medium therein. Only 17%-35% of the gas mass of the NGC 4650A ring is provided by molecular clouds, perhaps consistent with the conventional picture of the origin of polar rings in the capture of a dwarf galaxy or tidal mass transfer from a spiral galaxy. The polar ring of NGC 2685, however, is quite rich in molecular matter, with an H2 mass greater than the neutral atomic hydrogen mass. Such a composition may be difficult to explain with the picture that applies to NGC 4650A.

Watson, Dan M.↗

Final Test Results for the Ground Operations Demonstration Unit for Liquid Hydrogen

Described herein is a comprehensive project—a large-scale test of an integrated refrigeration and storage system called the Ground Operations and Demonstration Unit for Liquid Hydrogen (GODU LH2), sponsored by the Advanced Exploration Systems Program and constructed at Kennedy Space Center. A commercial cryogenic refrigerator interfaced with a 125,000 liter liquid hydrogen tank and auxiliary systems in a manner that enabled control of the propellant state by extracting heat via a closed loop Brayton cycle refrigerator coupled to a novel internal heat exchanger. Three primary objectives were demonstrating zero-loss storage and transfer, gaseous liquefaction, and propellant densification. Testing was performed at three different liquid hydrogen fill-levels. Data were collected on tank pressure, internal tank temperature profiles, mass flow in and out of the system, and refrigeration system performance. All test objectives were successfully achieved during approximately two years of testing. A summary of the final results is presented in this paper.

Zero Boil Off↗

Interfacial charge transfer driven by surface termination-controlled Ti 2 C MXene for enhanced hydrogen storage in magnesium

Two-dimensional transition metal carbides and nitrides (MXenes) with layered structure and high conductivity have been effectively utilized in various energy materials, including as a catalytic support of MgH 2 for hydrogen storage. However, the terminal groups formed on the surface during the etching step tend to deactivate reactive Mg metal and add dead mass, thereby deteriorating the catalytic role of MXene in hydrogen sorption of Mg. For this work, we exploited a molten-salt derived MXene with easily modifiable –Cl terminations, compared to conventional –O, –OH and –F groups, and synthesized a composite of Mg and delaminated Ti 2 CCl x MXene to improve the hydrogen storage performance of Mg through charge transfer. This strategy enables the formation of an intimate interface between Mg and MXene, facilitating charge transfer and thereby boosting the catalytic effect. The resulting composite demonstrates significantly enhanced hydrogen sorption kinetics by modulating Mg–H bond strength. This novel approach of modifying surface terminations leverages the unique properties of MXene as a superior support for active materials, offering broader applications in energy materials.

2D material↗

Numerical Modeling of Boiling in a Heated Tube

This paper presents numerical models of boiling in a heated tube using the Generalized Fluid System Simulation Program (GFSSP), a finite-volume-based general-purpose flow network code developed at NASA/Marshall Space Flight Center. The heated tube is discretized into a one-dimensional array of nodes and branches to represent the flow of liquid and vapor in a tube with a prescribed pressure differential. The solid wall is also discretized into solid nodes and conductors to allow for heat transfer between the wall and the fluid. The conservation equations of mass, momentum, and energy of the fluid are solved simultaneously with the energy conservation equation for the solid wall. Two experimental configurations of fluid flowing in a vertical tube have been simulated, one with water and the other with liquid hydrogen. This paper compares experimental data with numerical predictions based on four different published correlations for boiling heat transfer coefficients. Three of these correlations are applicable to the saturated vertical flow conditions of the experiments. One of them is applicable to film boiling and has been used for the liquid hydrogen experiment, which was in film boiling regime. For the case of boiling water, the predictions of wall temperatures using the boiling heat transfer correlations agreed well with the experimental results. However, in the case of boiling hydrogen larger discrepancies were observed between the experimental data and numerical predictions.

Majumdar, Alok↗

Electrical gas heater with large flow range capability

Auxiliary heat transfer device in form to tightly-wound helical tube was incorporated into conventional heater design to provide hydrogen heater with turn-down ratio greater than 100. Device greatly increases low flow rate capacity of heater by providing maximum heat-transfer area for low mass flows.

Benson, B. A.↗

Calculation of Propulsive Nozzle Flowfields in Multidiffusing Chemically Reacting Environments

An advanced engineering model has been developed to aid in the analysis and design of hydrogen/oxygen chemical rocket engines. The complete multispecies, chemically reacting and multidiffusing Navier-Stokes equations are modelled, including the Soret thermal diffusion and the Dufour energy transfer terms. In addition to the spectrum of multispecies aspects developed, the model developed in this study is also conservative in axisymmetric flow for both inviscid and viscous flow environments and the boundary conditions employ a viscous, chemically reacting, reference plane characteristics method. Demonstration cases are presented for a 1030:1 area ratio nozzle, a 25 lbf film cooled nozzle, and a transpiration cooled plug and spool rocket engine. The results indicate that the thrust coefficient predictions of the 1030:1 and the 25 lbf film cooled nozzle are within 0.2 to 0.5 percent, respectively, of experimental measurements when all of the chemical reaction and diffusion terms are considered. Further, the model's predictions agree very well with the heat transfer measurements made in all of the nozzle test cases. The Soret thermal diffusion term is demonstrated to have a significant effect on the predicted mass fraction of hydrogen along the wall of the nozzle in both the laminar flow 1030:1 nozzle and the turbulent flow plug and spool nozzle analysis cases performed. Further, the Soret term was shown to represent an important fraction of the diffusion fluxes occurring in a transpiration cooled rocket engine.

Kacynski, Kenneth John↗

The prediction of nozzle performance and heat transfer in hydrogen/oxygen rocket engines with transpiration cooling, film cooling, and high area ratios

An advanced engineering computational model has been developed to aid in the analysis and design of hydrogen/oxygen chemical rocket engines. The complete multi-species, chemically reacting and diffusing Navier-Stokes equations are modelled, finite difference approach that is tailored to be conservative in an axisymmetric coordinate system for both the inviscid and viscous terms. Demonstration cases are presented for a 1030:1 area ratio nozzle, a 25 lbf film cooled nozzle, and transpiration cooled plug-and-spool rocket engine. The results indicate that the thrust coefficient predictions of the 1030:1 nozzle and the film cooled nozzle are within 0.2 to 0.5 percent, respectively, of experimental measurements when all of the chemical reaction and diffusion terms are considered. Further, the model's predictions agree very well with the heat transfer measurements made in all of the nozzle test cases. The Soret thermal diffusion term is demonstrated to have a significant effect on the predicted mass fraction of hydrogen along the wall of the nozzle in both the laminar flow 1030:1 nozzle and the turbulent plug-and-spool rocket engine analysis cases performed. Further, the Soret term was shown to represent a significant fraction of the diffusion fluxes occurring in the transpiration cooled rocket engine.

Kacynski, Kenneth J.↗

Flight Weight Design Nickel-Hydrogen Cells Using Lightweight Nickel Fiber Electrodes

The goal of this program is to develop a lightweight nickel electrode for advanced aerospace nickel-hydrogen cells and batteries with improved specific energy and specific volume. The lightweight nickel electrode will improve the specific energy of a nickel-hydrogen cell by >50%. These near-term advanced batteries will reduce power system mass and volume, while decreasing the cost, thus increasing mission capabilities and enabling small spacecraft missions. This development also offers a cost savings over the traditional sinter development methods for fabrication. The technology has been transferred to Eagle-Picher, a major aerospace battery manufacturer, who has scaled up the process developed at NASA GRC and fabricated electrodes for incorporation into flight-weight nickel-hydrogen cells.

Britton, Doris L.↗

Brown dwarfs and Jovian planets: A comparison

The recent detection of a subluminous companion to the M dwarf star VB8 has renewed interest in the characteristics of objects spanning the mass range from Jupiter to hydrogen burning stars. Atmospheric and interior models were constructed for objects in this mass regime, up to 30 Jupiter masses, with emphasis on understanding the relationship of brown dwarfs such as the VB8 companion to the better-studied Jovian planets. The atmospheric model solves the equation of radiative transfer assuming frequency dependent molecular opacity sources H2, He, H2O, CO, and CH4 which are important by virtue of the high cosmic abundance of their constituent atoms. Condensation of cosmochemically important materials, iron and silicates, in the atmosphere is possible, and the effect of such grains as opacity sources is assessed. The luminosity of the object is presumed due to degenerate cooling following a collapse phase and possibly deuterium burning and an interior model is constructed using as an outer boundary condition the temperature and pressure level at which the atmosphere becomes convective. The interior model is analogous to Jupiter, with a large liquid metallic-hydrogen core and a thinner molecular-hydrogen envelope. The oxidation state of carbon in the outer envelope of a brown dwarf of similar age to Jupiter is a function of the object's mass. This makes the wavelength dependence of the atmospheric opacity sensitive to the carbon to oxygen ratio, since the abundance of the primary source of molecular opacity, H2O, decreases as more oxygen is tied up as CO.

Lunine, J. I.↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents computational fluid dynamics (CFD) models with conjugate heat transfer that are used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34-liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, and wall temperature. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface.

Computational Fluid Dynamics↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management (CFM) technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34 liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, fluid temperatures, and wall temperatures. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface. Several sensitivity studies are considered due to notable uncertainties in the experiment.

Computational Fluid Dynamics↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction Using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management (CFM) technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34 liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, fluid temperatures, and wall temperatures. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface. Several sensitivity studies are considered due to notable uncertainties in the experiment.

Computational Fluid Dynamics↗

The COLD-SAT experiment for cryogenic fluid management technology

The COLD-SAT spacecraft design experiments are described. COLD-SAT will be placed into an initial 1300 km circular orbit by an Atlas commercial launch vehicle. Electric power, experiment control and data management, attitude control, and propulsive accelarations for the experiments will be provided by the three-axis-controlled spacecraft bus. To provide data on the effects that low gravity levels might have on the heat and mass transfer processes involved, low levels of accelaration will be created. The COLD-SAT experiment will be configured into a module. The spacecraft experiment module will include three liquid hydrogen tanks; fluid transfer, pressurization and venting equipment; and instrumentation. Since the largest tank has helium-purged MLI to prevent ingress and freezing of air on the launchpad, it will contain all the liquid hydrogen at the point of launching. The hydrogen tanking system used for the Centaur upper stage of the Atlas will load and top off this tank. Atlas, with its liquid hydrogen upper stage, large payload fairing, and large launch margin, simplifies COLD-SAT design and integration.

Schuster, J. R.↗

PtRu Catalysts on Nitrogen-Doped Carbon Nanotubes with Conformal Hydrogenated TiO 2 Shells for Methanol Oxidation

The methanol oxidation reaction (MOR) is the limiting factor in direct methanol fuel cells (DMFC). There is an urgent need to improve the catalytic activity and stability of MOR catalysts. This study reports a highly active PtRu catalyst for MOR based on a hybrid multifunctional catalyst support consisting of a conformal amorphous hydrogenated TiO 2 shell wrapped around the oxygenated N-doped carbon nanotube core, denoted as PtRu/TiO 2 / ONCNT-400. Both the TiO 2 shell and the subsequent PtRu nanoparticles are deposited by a rapid microwave-assisted synthesis processes. The hydrogenated TiO 2 shell is found to exhibit a strong interaction with the deposited PtRu catalyst nanoparticles and effectively prevent them from agglomeration during the postdeposition thermal annealing to form more active crystalline PtRu alloy catalysts. In addition, the defective hydrogenated TiO 2 shell enhances the PtRu catalyst activity by the synergistic effects of partial charge transfer from TiO 2 to PtRu and high oxophilicity, which improves the kinetics of oxidation of poisonous CO intermediate to CO 2 . The mass activity for MOR and long-cycling stability of the PtRu/TiO 2 /ONCNT-400 catalyst surpass the two benchmark commercial PtRu/C catalysts from Johnson Matthey (JM) and Tanaka KiKinzoku (TKK), respectively. Furthermore, the results demonstrate that PtRu/TiO 2 /ONCNT-400 can serve as an efficient catalyst for MOR in DMFC.

36 MATERIALS SCIENCE↗

Project LOCOST: Laser or Chemical Hybrid Orbital Space Transport

A potential mission in the late 1990s is the servicing of spacecraft assets located in GEO. The Geosynchronous Operations Support Center (GeoShack) will be supported by a space transfer vehicle based at the Space Station (SS). The vehicle will transport cargo between the SS and the GeoShack. A proposed unmanned, laser or chemical hybrid orbital space transfer vehicle (LOCOST) can be used to efficiently transfer cargo between the two orbits. A preliminary design shows that an unmanned, laser/chemical hybrid vehicle results in the fuel savings needed while still providing fast trip times. The LOCOST vehicle receives a 12 MW laser beam from one Earth orbiting, solar pumped, iodide Laser Power Station (LPS). Two Energy Relay Units (ERU) provide laser beam support during periods of line-of-sight blockage by the Earth. The baseline mission specifies a 13 day round trip transfer time. The ship's configuration consist of an optical train, one hydrogen laser engine, two chemical engines, a 18 m by 29 m box truss, a mission-flexible payload module, and propellant tanks. Overall vehicle dry mass is 8,000 kg. Outbound cargo mass is 20,000 kg, and inbound cargo mass is 6,000 kg. The baseline mission needs 93,000 kg of propellants to complete the scenario. Fully fueled, outbound mission mass is 121,000 kg. A regeneratively cooled, single plasma, laser engine design producing a maximum of 768 N of thrust is utilized along with two traditional chemical engines. The payload module is designed to hold 40,000 kg of cargo, though the baseline mission specifies less. A proposed design of a laser/chemical hybrid vehicle provides a trip time and propellant efficient means to transport cargo from the SS to a GeoShack. Its unique, hybrid propulsion system provides safety through redundancy, allows baseline missions to be efficiently executed, while still allowing for the possibility of larger cargo transfers.

Dixon, Alan↗

Thrust Enhancement in Hypervelocity Nozzles by Chemical Catalysis

In the hypersonic flight regime, the air-breathing supersonic combustion ramjet (scramjet) has been shown to be a viable propulsion system. The current designs of scramjet engines provide performance benefits only up to a Mach number of 14. Performance losses increase rapidly as the Mach number increases. To extend the applicability of scram'jets beyond Mach 14, research is being conducted in the area of inlet and wave drag reduction, skin-friction and heat-transfer reduction, nozzle loss minimization, low-loss mixing, and combustion enhancement. For high Mach number applications, hydrogen is the obvious fuel choice because of its high energy content per unit mass in comparison with conventional fuels. These flight conditions require engines to operate at supersonic internal velocities, high combustor temperatures, and low static pressures. The high static temperature condition enhances the production of radicals such as H and OH, and the low-pressure condition slows the reaction rates, particularly the recombination reactions. High-temperature and low-pressure constraints, in combination with a small residence time, result in a radical-rich exhaust gas mixture exiting the combustor. At high Mach number conditions (due to low residence time), H and OH do not have enough time to recombine ; thus, a significant amount of energy is lost as these high-energy free radical are exhausted. The objective of the present study is to conduct a flowfield analysis for a typical nozzle geometry for NASP-type vehicle to assess for thrust enhancement in hypervelocity nozzles by substituting small amount of phosphine for hydrogen.

Singh, D. J.↗

Green hydrogen from microalgal liquefaction byproducts with ammonia recovery and effluent recycle for developing circular processes

Hydrothermal liquefaction is a promising technology for microalgae-based biofuel production. However, hydrothermal liquefaction’s aqueous wastes have little established reuse, and contain significant fractions of toxic ammoniacal nitrogen. Careful reuse of this waste can assure microalgae-based biofuels are produced with less environmental impact and larger energy efficiency. Microbial electrolysis cells were investigated to valorize this waste product by converting the leftover organics into hydrogen and remove ammonia. Waste hydrothermal liquefaction aqueous phase from two microalgal strains, Tetraselmis sp. and Chlorella sp. were used as feedstocks for hydrogen production in microbial electrolysis cells. Chlorella and Tetraselmis aqueous phase-fed microbial electrolysis cells reach an average current density of 5.1 ± 0.19 A/m 2 and 3.8 ± 0.08 A/m 2 . Compound removal rates and mass removal percentages were also investigated for each feedstock. Additionally, acetic acid, propionic acid, ethanol, and glycerol were effectively removed from the aqueous byproduct. Further, microbial electrolysis cells separated up to 34.3% of ammoniacal nitrogen present in the aqueous phase. Charge transfer analysis indicated that proton transfer, not ammonium transfer, contributed to the majority of the hydrogen production in the cathode. Finally, the microbial electrolysis cell effluent was reused to grow the same microalgal strains, leading to the development of a circular biofuel production system. Microalgae regrowth studies using microbial electrolysis cell effluent showed nearly complete removal of total organic carbon, but significantly less removal of total nitrogen. Tetraselmis sp. growth occurred with the Tetraselmis-derived MEC effluent, however, the control medium without effluent produced the most growth. These findings support the possibility of a circular biofuel framework using MECs, but additional constraints, including the removal of inorganic contaminants, are necessary to realize the circular processes.

09 BIOMASS FUELS↗

BOILING HEAT TRANSFER TO LIQUID HYDROGEN AND NITROGEN IN FORCED FLOW

Boiling heat transfer to liquid hydrogen and nitrogen was investigated experimentally. Results are presented from a study of bulk boiling inside a cylindrical tube under vertically upward forced-flow conditions. A 0.555-inch-inside-diameter and 16 (1/8)-inch-long electrically heated stainless-steel tube was used. The range of variables studied for hydrogen were mass velocity of 2850 to 17,000 pounds per hour per square foot, local heat flux of 3600 to 40,000 Btu per hour per square foot, inlet pressure of 30 to 74 pounds per square inch absolute, and inlet subcooling of 0° to 9° R. Nitrogen test conditions were mass velocity of 15,000 to 56,000 pounds per hour per square foot, local heat flux of 2300 to 40,000 Btu per hour per square foot, inlet pressure of 47 to 56 pounds per square inch absolute, and inlet sub cooling of 1° to 6° R. The axial distribution of the tube-wall temperatures is presented. A transition in the type of boiling heat transfer was obtained. The critical heat flux corresponding to this transition was determined over a range of flow and heating rates and local qualities. At specific combinations of flow and transition location, a range of critical-heat-flux values was obtained and maximum values were determined. The maximum critical heat flux increased with increasing fluid-flow rate and decreased with increasing length of tube before transition. Similar variations of the maximum critical heat flux have been reported for water. The tube-inner-wall temperatures upstream of transition were essentially uniform and were only slightly greater than the fluid saturation temperature. The Wall-temperature profiles downstream of transition generally resembled those obtained in film-boiling studies and appeared to be strongly dependent upon local quality at the point of transition. Maximum wall temperatures of 9000 and 18000 R were obtained with hydrogen and nitrogen, respectively. Fluctuations of pressure, flow rate, and temperature occurred during some of the boiling tests. Under some conditions, maximum critical-heat-flux values were attained during steady-state operation with fluctuations. In other cases the fluctuations became uncontrolled, and critical-flux values less than the maximum values were obtained upon restabilization of the test conditions. No measurable pressure drop across the test section was obtained at any condition.

LIQUID HYDROGEN↗