Hybrid-Circuit Module For Dc-To-Dc Power Converter

Power hybrid module is general-purpose power-switching module providing flexibility in design and application. Complete dc-to-dc power converter constructed by adding input/output filters and feedback circuitry to module to suit specific application.

Vorperian, Vatche↗

A hybrid electrical power system for aircraft application.

Possible improvements to present aircraft electrical power systems for use in future advanced types of aircraft have been investigated. The conventional power system is examined, the characteristics of electric loads are reviewed, and various methods of power generation and distribution are appraised. It is shown that a hybrid system, with variable-frequency generation and high-voltage dc distribution, could overcome some of the limitations of the conventional system.

Lee, C. H.↗

Urban Air Mobility Network and Vehicle Type - Modeling and Assessment

This paper describes exploratory modeling of an on-demand urban air mobility (UAM) network and sizing of vehicles to operate within that network. UAM seeks to improve the movement of goods and people around a metropolitan area by utilizing the airspace for transport. Aircraft sizing and overall network performance results are presented that include comparisons of battery-electric and various hybrid-electric vehicles that are fueled with diesel, jet fuel, compressed natural gas, and liquefied natural gas (LNG). Hybrid-electric propulsion systems consisting of internal combustion engine-generators, turbine-generators, and solid oxide fuel cells are explored. Ultimately, the "performance" of the UAM network over a day for each of the different vehicle types, propulsion systems, and stored energy sources is described in four parameters: 1) the average cost per seat-kilometer, which considers the costs of the energy/fuel, vehicle acquisition, insurance, maintenance, pilot, and battery replacement costs, 2) carbon dioxide emission rates associated with vehicle operations, 3) the average passenger wait time, and 4) the average load factor, i.e., the total number of seats filled with paying passengers divided by the total number of available seats. Results indicate that the "dispatch model," which determines when and where aircraft are flown around the UAM network, is critical in determining the overall network performance. This is due to the often-conflicting desires to allow passengers to depart with minimal wait time while still maintaining a high load factor to reduce operating costs. Additionally, regardless of the dispatch model, hybrid-electric aircraft powered by internal combustion engines fueled with diesel or LNG are consistently the lowest cost per seat-kilometer. Battery-electric and future technology LNG/solid oxide fuel cell aircraft produce the lowest emissions (assuming the California grid) with LNG-fueled internal combustion engine-powered hybrids producing only slightly more carbon dioxide.

Assessment↗

Turbine Powered Simulator Calibration and Testing for Hybrid Wing Body Powered Airframe Integration

Propulsion airframe integration testing on a 5.75% scale hybrid wing body model us- ing turbine powered simulators was completed at the National Full-Scale Aerodynamics Complex 40- by 80-foot test section. Four rear control surface con gurations including a no control surface de ection con guration were tested with the turbine powered simulator units to investigate how the jet exhaust in uenced the control surface performance as re- lated to the resultant forces and moments on the model. Compared to ow-through nacelle testing on the same hybrid wing body model, the control surface e ectiveness was found to increase with the turbine powered simulator units operating. This was true for pitching moment, lift, and drag although pitching moment was the parameter of greatest interest for this project. With the turbine powered simulator units operating, the model pitching moment was seen to increase when compared to the ow-through nacelle con guration indicating that the center elevon and vertical tail control authority increased with the jet exhaust from the turbine powered simulator units.

Shea, Patrick R.↗

Parametric analysis on optimized design of hybrid solar power plants

There is increasing interest in utility-scale solar power plants with storage which can flexibly dispatch renewable energy to the grid. However, plant design possesses many degrees of freedom and non-obvious trade-offs in performance. Software tools can estimate or optimize the performance of a specific plant configuration under market and weather conditions of interest; the associated cost parameters and operating assumptions strongly influence estimates of plant performance and decisions regarding optimal sizing. We employ the National Renewable Energy Laboratory's Hybrid Optimization and Performance Platform, which incorporates optimal dispatch when evaluating plant performance, and investigate the sensitivity to weather and market conditions, operating limitations, and the presence of a capacity-based incentive. We demonstrate changes in plant performance and optimal sizing with respect to these inputs and discuss implications. Here results show that PV-with-battery designs are more profitable under our assumptions, but that designs including a concentrated solar power (CSP) system produce significantly greater annual energy; and that CSP-with-thermal energy storage designs maximizing the benefit-to-cost ratio have an input-dependent linear relationship between the CSP field solar multiple and the hours of storage as the project budget varies.

14 SOLAR ENERGY↗

Hybrid-Energy-Powered Electrochemical Ocean Alkalinity Enhancement Model: Plant Operation, Cost, and Profitability

Electrochemical ocean alkalinity enhancement is a form of marine carbon dioxide removal, a rapidly growing industry that is powered by efficient onshore or offshore energy sources. As more and larger deployments are being planned, it is important to consider how variable energy sources like tidal energy can impact plant performance and costs. An open-source Python-based generalizable model for electrodialysis-based ocean alkalinity enhancement has been developed that can capture key system-level insights of the electrochemistry, ocean chemistry, acid disposal, and co-product creation of these plants under various conditions. The model additionally accounts for hybrid energy system performance profiles and costs via the National Laboratory of the Rockies’ H2Integrate tool. The model was used to analyze an example theoretical plant deployment in North Admiralty Inlet, including how the plant is impacted by the available energy sources in the region and the scale at which plant costs are covered by the co-products it generates, such as recycled concrete aggregates, without requiring carbon credits. The results show that the example plant could be profitable without carbon credits at commercial scales of 100,000 to 1 million tons of carbon dioxide removal per year, so long as it uses low-cost electricity sources and either sells acid or recovers recycled concrete aggregates with about 1 molar acid concentrations, though more research is needed to confirm these results.

hybrid energy↗

A Compact 50kW High Power Density, Hybrid 3-Level Paralleled T-type Inverter for More Electric Aircraft Applications

The demand for high performing, lightweight, reliable inverters, increased the scope of wide bandgap and high-switching frequency based solutions. To achieve such high efficiency inverters, it is vital to focus on the system level design considerations to maximize the benefits of these advanced technologies. This paper presents an improved design based on considerations to further reap the benefits of choosing the right inverter topology; increased capabilities through paralleling devices, with reduced total number of switches; and designing a planarized inverter with PCB based busbar. Appropriate thermal analysis and heatsink design has aided in increased system power density along with the overall efficiency. Demonstration of a 50kW 3-phase 3-level paralleled T-type SiC inverter operating at 40kHz switching frequency for aircraft applications is shown to evaluate the benefits of proposed design methodology. Here, the prototype achieves a high power density of 11kW/L.

42 ENGINEERING↗

Establishment of quality, reliability and design standards for low, medium, and high power microwave hybrid microcircuits

Quality, reliability, and design standards for microwave hybrid microcircuits were established. The MSFC Standard 85M03926 for hybrid microcircuits was reviewed and modifications were generated for use with microwave hybrid microcircuits. The results for reliability tests of microwave thin film capacitors, transistors, and microwave circuits are presented. Twenty-two microwave receivers were tested for 13,500 unit hours. The result of 111,121 module burn-in and operating hours for an integrated solid state transceiver module is reported.

Robinson, E. A.↗

A 2023 Perspective: What Is the Value of Hybridization?

This report takes a wind developer's perspective and provides a summary of the current and future state of hybrid facilities, and ultimately seeks to answer the question: "Are hybrid power plants a pivotal tool for meeting future energy and decarbonization targets?" The intention is not to provide an in-depth system-level technical analysis of hybrid facilities, but to showcase a high-level overview of the hybrid facility ecosystem and its potential future directions. Lastly, the authors acknowledge and recognize that non-renewable generation technologies can be integrated into a hybrid facility, however these technologies are outside the scope of this report.

17 WIND ENERGY↗

Hybrid Solid Oxide Fuel Cell/Gas Turbine Model Development for Electric Aviation

A thermodynamic model was developed and validated to analyze a high-performance solid oxide fuel cell and gas turbine (SOFC-GT) hybrid power system for electric aviation. This study used a process simulation software package (ProMax) to study the role of SOFC design and operation on the feasibility and performance of the hybrid system. Standard modules, including compressor, turbine, heat exchanger, reforming reactor, and combustor were used from the ProMax tool suite while a custom module was created to simulate the SOFC stack. The model used an SOFC test data set as an input. Additional SOFC stack performance effects, such as pressure, temperature, and utilization of air and fuel, were added from open source data. System performance predictors were SOFC specific power, fuel-to-electricity conversion efficiency, and hybrid system efficiency. Using these input data and predictors, a static thermodynamic performance model was created that can be modified for different system configurations and operating conditions. Prior to creating the final aircraft performance model, initial demonstration models were developed to validate output results. We used the NASA SOFC model as a benchmark, which was created with their Numerical Propulsion System Simulator (NPSS) software framework. Our output results matched within 1% of both the NASA model and open source SOFC performance data. With confidence gained in the accuracy of this model, a 1-MW SOFC-GT hybrid power system was constructed for an aircraft propulsion concept. Overall hybrid system efficiencies of > 75% FTE were observed during standard 36,000 feet cruise flight conditions.

30 DIRECT ENERGY CONVERSION↗

Human-in-the-Loop Motion Control of a Two-DOF Hydraulic Backhoe Powered by the Hybrid Hydraulic Electric Architecture (HHEA)

Abstract The Hybrid Hydraulic-Electric Architecture (HHEA) combines the respective power density and control advantages of hydraulic and electric actuation to save energy for off-road vehicles. It uses a set of selectable common pressure rails to transmit the majority of power and electric actuation to modulate that power. As it is critical that off-road vehicles can perform tasks dexterously and exactly as commanded by the operator, the switchings between discrete pressure rails pose a potential challenge for smooth and precise motion. A control strategy consisting of a backstepping nominal control and least norm transition control has previously been developed to address this issue. It has been tested on 1 degree of freedom (DOF) testbeds where known trajectories were able to be tracked precisely. This paper presents the implementation of the HHEA motion control strategy on a 2-DOF backhoe operated by a human operator via a 2-DOF joystick. Unlike previous studies, the duty cycle is unknown beforehand and the decision to change pressure rails is taken in real-time. The efficacy of the motion control strategy has been validated experimentally. Several strategies to improve the user interface: control in workspace coordinates, pressure feedback, and velocity field-based task specification, have also been implemented and demonstrated to make operating the multiple DOF, HHEA actuated machine more intuitive to novice operators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Forming Control Tuning for a Hybrid Inverter-Based Resource Power Plant

A hybrid inverter-based resource (IBR) power plant consists of grid-following (GFL) and grid-forming inverter-based resources (GFM-IBR) connected in parallel. Here, this research focuses on how to design and tune GFM's control parameters to ensure stable operation of the hybrid power plant for weak and strong grid conditions. We consider two design cases: one where the GFL-IBR does not provide frequency support, and one where it does. It is found that the GFM's power-frequency synchronizing system can lose stability when the power-frequency droop constant is large and/or the grid is strong. Additionally, if the GFL has its frequency support enabled, oscillation stability worsens. To explain the mechanism of the interactions, we construct a feedback system for the synchronizing loop, which consists of the GFM's power-frequency droop control that generates the GFM's synchronizing angle, the GFL's phase-locked loop that measures the voltage phase angle, the GFL's frequency-power control that generates its power order, and the rest of the system. The feedback system is effective in illustrating the potential stability risks. Successful design ensures that the hybrid power plant can operate smoothly and ride through grid disturbances.

feedback systems↗

Development of Real-Time System Identification to Detect Abnormal Operations in a Gas Turbine Cycle

Here, we present a novel online system identification methodology for monitoring the performance of power systems. This methodology was demonstrated in a gas turbine recuperated power plant designed for a hybrid configuration. A 120-kW Garrett microturbine modified to test dynamic control strategies for hybrid power systems designed at the National Energy Technology Laboratory (NETL) was used to implement and validate this online system identification methodology. The main component of this methodology consists of an empirical transfer function model implemented in parallel to the turbine speed operation and the fuel control valve, which can monitor the process response of the gas turbine system while it is operating. During fully closed-loop operations or automated control, the output of the controller, fuel valve position, and the turbine speed measurements were fed for a given period of time to a recursive algorithm that determined the transfer function parameters during the nominal condition. After the new parameters were calculated, they were fed into the transfer function model for online prediction. The turbine speed measurement was compared against the transfer function prediction, and a control logic was implemented to capture when the system operated at nominal or abnormal conditions. To validate the ability to detect abnormal conditions during dynamic operations, drifting in the performance of the gas turbine system was evaluated. A leak in the turbomachinery working fluid was emulated by bleeding 10% of the airflow from the compressor discharge to the atmosphere, and electrical load steps were performed before and after the leak. This tool could detect the leak 7 s after it had occurred, which accounted for a fuel flow increase of approximately 15.8% to maintain the same load and constant turbine speed operations.

algorithms↗

The 10 kW power electronics for hydrogen arcjets

A combination of emerging mission considerations such as 'launch on schedule', resource limitations, and the development of higher power spacecraft busses has resulted in renewed interest in high power hydrogen arcjet systems with specific impulses greater than 1000 s for Earth-space orbit transfer and maneuver applications. Solar electric propulsion systems with about 10 kW of power appear to offer payload benefits at acceptable trip times. This work outlines the design and development of 10 kW hydrogen arcjet power electronics and results of arcjet integration testing. The power electronics incorporated a full bridge switching topology similar to that employed in state of the art 5 kW power electronics, and the output filter included an output current averaging inductor with an integral pulse generation winding for arcjet ignition. Phase shifted, pulse width modulation with current mode control was used to regulate the current delivered to arcjet, and a low inductance power stage minimized switching transients. Hybrid power Metal Oxide Semiconductor Field Effect Transistors were used to minimize conduction losses. Switching losses were minimized using a fast response, optically isolated, totem-pole gate drive circuit. The input bus voltage for the unit was 150 V, with a maximum output voltage of 225 V. The switching frequency of 20 kHz was a compromise between mass savings and higher efficiency. Power conversion efficiencies in excess of 0.94 were demonstrated, along with steady state load current regulation of 1 percent. The power electronics were successfully integrated with a 10 kW laboratory hydrogen arcjet, and reliable, nondestructive starts and transitions to steady state operation were demonstrated. The estimated specific mass for a flight packaged unit was 2 kg/kW.

Hamley, John A.↗

Small-RPS Enabled Mars Rover Concept

Both the MER and the Mars Pathfinder rovers operated on Mars in an energy-limited mode, since the solar panels generated power during daylight hours only. At other times the rovers relied on power stored in batteries. In comparison, Radioisotope Power Systems (RPS) offer a power-enabled paradigm, where power can be generated for long mission durations (measured in years), independently from the Sun, and on a continuous basis. A study was performed at PL to assess the feasibility of a small-RPS enabled MER-class rover concept and any associated advantages of its mission on Mars. The rover concept relied on design heritage from MER with two significant changes. First, the solar panels were replaced with two single GPHS module based small-RPSs. Second, the Mossbauer spectroscope was substituted with a laser Raman spectroscope, in order to move towards MEPAG defined astrobiology driven science goals. The highest power requirements were contributed to mobility and telecommunication type operating modes, hence influencing power system sizing. The resulting hybrid power system included two small-RPSs and two batteries. Each small-RPS was assumed to generate 50We of power or 62OWh/sol of energy (BOL), comparable to that of MER. The two 8Ah batteries were considered available during peak power usage. Mission architecture, power trades, science instruments, data, communication, thermal and radiation environments, mobility, mass issues were also addressed. The study demonstrated that a new set of RPS-enabled rover missions could be envisioned for Mars exploration within the next decade, targeting astrobiology oriented science objectives, while powered by 2 to 4 GPHS modules.

Mars exploration↗

Thermo-economic analysis of a solid oxide fuel cell-gas turbine hybrid with commercial off-the-shelf gas turbine

The thermodynamic and economic performance of a natural gas-fueled solid oxide fuel cell (SOFC)-gas turbine (GT) hybrid system with a commercial off-the-shelf GT is investigated. Until today, commercial GTs are primarily engineered for the direct use of energy dense fuels, such as natural gas, and the integration of commercial GTs into a SOFC-GT hybrid remains challenging. In this work technically feasible and economically viable GT operating modes are identified to gauge the technology’s competitiveness on the free market. Steady state, full load operating conditions were established for various GT operating modes: I) constant spool speed operation, II) variable spool speed operation and III) partially closed compressor inlet guide vanes. For each GT operating mode, the performance was investigated over a range of SOFC fuel utilization factors, while considering physical constraints inside the SOFC, such as local temperature gradients in flow direction as well as overall cell temperature differences. The results of the thermodynamic evaluation served as inputs for the economic analysis of the SOFC-GT hybrid power plant. The results show that the integration of an off-the-shelf GT not only results in a significant derating of the GT, but also substantially impacts the SOFC operation, the main power producer in this SOFC-GT hybrid. To maximize the SOFC power output it is desirable operate the GT in a region of high air mass flow rates and low pressure ratios, which increases the number of stacks that can be accommodated and reduces the SOFC cooling requirement. The lowest costs of electricity are obtained at constant spool speed operation, while the highest efficiencies are reached at variable spool speed operation. Critical for the integration of off-the-shelf GTs, which historically have been designed for natural gas, is the surge margin. The largest surge margins are obtained by closing the compressor inlet guide vanes. Furthermore, higher SOFC fuel utilization factors are shown to increase the surge margin as the turbine firing temperature is decreased.

25 ENERGY STORAGE↗

Operational compatibility of 30-centimeter-diameter ion thruster with integrally regulated solar array power source

System tests were performed in which Integrally Regulated Solar Arrays (IRSA's) were used to directly power the beam and accelerator loads of a 30-cm-diameter, electron bombardment, mercury ion thruster. The remaining thruster loads were supplied from conventional power-processing circuits. This combination of IRSA's and conventional circuits formed a hybrid power processor. Thruster performance was evaluated at 3/4- and 1-A beam currents with both the IRSA-hybrid and conventional power processors and was found to be identical for both systems. Power processing is significantly more efficient with the hybrid system. System dynamics and IRSA response to thruster arcs are also examined.

Gooder, S. T.↗