Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Development of microcomputer-based mental acuity tests

Recent disasters have focused attention on performance problems due to the use of alcohol and controlled substances in the workplace. Environmental stressors such as thermal extremes, mixed gases, noise, motion, and vibration also have adverse effects on human performance and operator efficiency. However, the lack of a standardized, sensitive, human performance assessment battery has probably delayed the systematic study of the deleterious effects of various toxic chemicals and drugs at home and in the workplace. The collective goal of the research reported here is the development of a menu of tests embedded in a coherent package of hardware and software that may be useful in repeated-measures studies of a broad range of agents that can degrade human performance. A menu of 40 tests from the Automated Performance Test System (APTS) is described, and the series of interlocking studies supporting its development is reviewed. The APTS tests, which run on several versions of laptop portables and desktop personal computers, have been shown to be stable, reliable, and factorially rich, and to have predictive validities with holistic measures of intelligence and simulator performances. In addition, sensitivity studies have been conducted in which performance changes due to stressors, agents, and treatments were demonstrated. We believe that tests like those described here have prospective use as an adjunct to urine testing for the screening for performance loss of individuals who are granted access to workplaces and stations that impact public safety.

Non-NASA Center↗

Using Apex To Construct CPM-GOMS Models

process for automatically generating computational models of human/computer interactions as well as graphical and textual representations of the models has been built on the conceptual foundation of a method known in the art as CPM-GOMS. This method is so named because it combines (1) the task decomposition of analysis according to an underlying method known in the art as the goals, operators, methods, and selection (GOMS) method with (2) a model of human resource usage at the level of cognitive, perceptual, and motor (CPM) operations. CPM-GOMS models have made accurate predictions about behaviors of skilled computer users in routine tasks, but heretofore, such models have been generated in a tedious, error-prone manual process. In the present process, CPM-GOMS models are generated automatically from a hierarchical task decomposition expressed by use of a computer program, known as Apex, designed previously to be used to model human behavior in complex, dynamic tasks. An inherent capability of Apex for scheduling of resources automates the difficult task of interleaving the cognitive, perceptual, and motor resources that underlie common task operators (e.g., move and click mouse). The user interface of Apex automatically generates Program Evaluation Review Technique (PERT) charts, which enable modelers to visualize the complex parallel behavior represented by a model. Because interleaving and the generation of displays to aid visualization are automated, it is now feasible to construct arbitrarily long sequences of behaviors. The process was tested by using Apex to create a CPM-GOMS model of a relatively simple human/computer-interaction task and comparing the time predictions of the model and measurements of the times taken by human users in performing the various steps of the task. The task was to withdraw $80 in cash from an automated teller machine (ATM). For the test, a Visual Basic mockup of an ATM was created, with a provision for input from (and measurement of the performance of) the user via a mouse. The times predicted by the automatically generated model turned out to approximate the measured times fairly well (see figure). While these results are promising, there is need for further development of the process. Moreover, it will also be necessary to test other, more complex models: The actions required of the user in the ATM task are too sequential to involve substantial parallelism and interleaving and, hence, do not serve as an adequate test of the unique strength of CPM-GOMS models to accommodate parallelism and interleaving.

John, Bonnie↗

Optical range and range rate estimation for teleoperator systems

Range and range rate are crucial parameters which must be available to the operator during remote controlled orbital docking operations. A method was developed for the estimation of both these parameters using an aided television system. An experiment was performed to determine the human operator's capability to measure displayed image size using a fixed reticle or movable cursor as the television aid. The movable cursor was found to yield mean image size estimation errors on the order of 2.3 per cent of the correct value. This error rate was significantly lower than that for the fixed reticle. Performance using the movable cursor was found to be less sensitive to signal-to-noise ratio variation than was that for the fixed reticle. The mean image size estimation errors for the movable cursor correspond to an error of approximately 2.25 per cent in range suggesting that the system has some merit. Determining the accuracy of range rate estimation using a rate controlled cursor will require further experimentation.

Shields, N. L., Jr.↗

Dynamical relations for left ventricular ejection - Flow rate, momentum, force and impulse

An investigation was carried out to quantitatively evaluate left ventricular volume flow rate, momentum, force and impulse derived from application of conservation principles for mass and momentum of blood within the ventricle during the ejection phase. An automated digital image processing system was developed and applied to left ventricular angiograms which are computer processed and analyzed frame by frame to determine the dynamical relations by numerical methods. The initial experience with force and impulse has indicated that neither quantity seemed to be a sensitive indicator of coronary artery disease as evaluated by qualitative angiography for the particular patient group studied. Utilization of the dynamical relations in evaluating human left ventricular performance requires improved means of measurement and interpretation of clinical studies.

Back, L. H.↗

STS-78 Flight Day 3

On this third day of the STS-78 mission, the flight crew, Cmdr. Terence T. Henricks, Pilot Kevin R. Kregel, Payload Cmdr. Susan J. Helms, Mission Specialists Richard M. Linnehan, Charles E. Brady, Jr., and Payload Specialists Jean-Jacques Favier, Ph.D. and Robert B. Thirsk, M.D., are shown performing human physiology tests that include the Direct Measurement of the Initial Bone Response to Space Flight. Various members of the crew can be seen exercising on the bicycle ergometer cardiovascular system.

Source record↗

Instrumentation for Non-Invasive Assessment of Cardiovascular Regulation

It is critically important to be able to assess alterations in cardiovascular regulation during and after space flight. We propose to develop an instrument for the non-invasive assessment of such alterations that can be used on the ground and potentially during space flight. This instrumentation would be used by the Cardiovascular Alterations Team at multiple sites for the study of the effects of space flight on the cardiovascular system and the evaluation of countermeasures. In particular, the Cardiovascular Alterations Team will use this instrumentation in conjunction with ground-based human bed-rest studies and during application of acute stresses e.g., tilt, lower body negative pressure, and exercise. In future studies, the Cardiovascular Alterations Team anticipates using this instrumentation to study astronauts before and after space flight and ultimately, during space flight. The instrumentation may also be used by the Bone Demineralization/Calcium Metabolism Team, the Neurovestibular Team and the Human Performance Factors, Sleep and Chronobiology Team to measure changes in autonomic nervous function. The instrumentation will be based on a powerful new technology - cardiovascular system identification (CSI) - which has been developed in our laboratory. CSI provides a non-invasive approach for the study of alterations in cardiovascular regulation. This approach involves the analysis of second-to-second fluctuations in physiologic signals such as heart rate and non-invasively measured arterial blood pressure in order to characterize quantitatively the physiologic mechanisms responsible for the couplings between these signals. Through the characterization of multiple physiologic mechanisms, CSI provides a closed-loop model of the cardiovascular regulatory state in an individual subject.

Cohen, Richard J.↗

The measurement and facilitation of cooperative task performance

Experiments were conducted to determine under what conditions jaw clenching will occur in humans as a response to stress exposure. The method for measuring reactions to stress involves a series of electrical recordings of the masseter and temporalis muscles. A high fixed-ratio response requirement in the first series of experiments shows that jaw clenching in humans occurs in situations analogous to those which produce biting in infrahuman subjects. In the second series, reduction in the amounts of money recieved by subjects is shown to cause increases in the jaw clench response and other negative effect motor behaviors. The third series demonstrates that perception of more favorable conditions existing for another person can increase anger and hostility in the subject.

Hutchinson, R. R.↗

Neurophysiological predictors of quality of performance

New signal processing technologies have been developed to measure spatiotemporal neurocognitive processes of the human brain. In one experiment, application of these technologies produced measurements of distributed preparatory sets which predicted the accuracy of subsequent performance. In another experiment, neuroelectric changes were found in Air Force test pilots during the incipient stages of fatigue before behavior had severely degraded.

Gevins, Alan S.↗

Behavioral Health and Performance Laboratory Standard Measures (BHP-SM)

The Spaceflight Standard Measures is a NASA Johnson Space Center Human Research Project (HRP) project that proposes to collect a set of core measurements, representative of many of the human spaceflight risks, from astronauts before, during and after long-duration International Space Station (ISS) missions. The term "standard measures" is defined as a set of core measurements, including physiological, biochemical, psychosocial, cognitive, and functional, that are reliable, valid, and accepted in terrestrial science, are associated with a specific and measurable outcome known to occur as a consequence of spaceflight, that will be collected in a standardized fashion from all (or most) crewmembers. While such measures might be used to define standards of health and performance or readiness for flight, the prime intent in their collection is to allow longitudinal analysis of multiple parameters in order to answer a variety of operational, occupational, and research-based questions. These questions are generally at a high level, and the approach for this project is to populate the standard measures database with the smallest set of data necessary to indicate further detailed research is required. Also included as standard measures are parameters that are not outcome-based in and of-themselves, but provide ancillary information that supports interpretation of the outcome measures, e.g., nutritional assessment, vehicle environmental parameters, crew debriefs, etc. The project's main aim is to ensure that an optimized minimal set of measures is consistently captured from all ISS crewmembers until the end of Station in order to characterize the human in space. -This allows the HRP to identify, establish, and evaluate a common set of measures for use in spaceflight and analog research to: develop baselines, systematically characterize risk likelihood and consequences, and assess effectiveness of countermeasures that work for behavioral health and performance risk factors. -By standardizing the battery of measures on all crewmembers, it will allow the HRP to evaluate countermeasures that work for one physiological system and ensure another system is not negatively affected. -These measures, named "Standard Measures," will serve as a data repository and be available to other studies under data sharing agreements.

Williams, Thomas J.↗

An Illumination Modeling System for Human Factors Analyses

Seeing is critical to human performance. Lighting is critical for seeing. Therefore, lighting is critical to human performance. This is common sense, and here on earth, it is easily taken for granted. However, on orbit, because the sun will rise or set every 45 minutes on average, humans working in space must cope with extremely dynamic lighting conditions. Contrast conditions of harsh shadowing and glare is also severe. The prediction of lighting conditions for critical operations is essential. Crew training can factor lighting into the lesson plans when necessary. Mission planners can determine whether low-light video cameras are required or whether additional luminaires need to be flown. The optimization of the quantity and quality of light is needed because of the effects on crew safety, on electrical power and on equipment maintainability. To address all of these issues, an illumination modeling system has been developed by the Graphics Research and Analyses Facility (GRAF) and Lighting Environment Test Facility (LETF) in the Space Human Factors Laboratory at NASA Johnson Space Center. The system uses physically based ray tracing software (Radiance) developed at Lawrence Berkeley Laboratories, a human factors oriented geometric modeling system (PLAID) and an extensive database of humans and environments. Material reflectivity properties of major surfaces and critical surfaces are measured using a gonio-reflectometer. Luminaires (lights) are measured for beam spread distribution, color and intensity. Video camera performances are measured for color and light sensitivity. 3D geometric models of humans and the environment are combined with the material and light models to form a system capable of predicting lighting conditions and visibility conditions in space.

Huynh, Thong↗

Frequency Analysis Of Data On Telerobotic Tasks

Data on forces and torques measured in experiments with remote manipulators processed into spectral signatures via special frequency-analysis procedure. Spectral signatures complement other measures used to evaluate performances of telerobotic systems and human operators. Contributes to verification of some assumptions made in designing manipulator arms and control subsystems and used as feedback by operators engaged in realtime monitoring of telerobotic tasks. Also provides useful indications of flows of power between manipulators and their environments.

Fiorini, Paolo↗

The N2-P3 complex of the evoked potential and human performance

The N2-P3 complex and other endogenous components of human evoked potential provide a set of tools for the investigation of human perceptual and cognitive processes. These multidimensional measures of central nervous system bioelectrical activity respond to a variety of environmental and internal factors which have been experimentally characterized. Their application to the analysis of human performance in naturalistic task environments is just beginning. Converging evidence suggests that the N2-P3 complex reflects processes of stimulus evaluation, perceptual resource allocation, and decision making that proceed in parallel, rather than in series, with response generation. Utilization of these EP components may provide insights into the central nervous system mechanisms modulating task performance unavailable from behavioral measures alone. The sensitivity of the N2-P3 complex to neuropathology, psychopathology, and pharmacological manipulation suggests that these components might provide sensitive markers for the effects of environmental stressors on the human central nervous system.

Odonnell, Brian F.↗

The Unintended Consequences of Focusing on Human Error (And How You Can Help)

The literature on human performance is rich with findings of cognitive failures and methods to identify, label, and measure them. In many real-world contexts, however, outcomes are driven far more by successful than failed cognition. Designers of systems intended for human use, in an effort to be “data driven,” rely upon findings from the cognitive performance literature to inform their system designs. When most available data are about human error, data-driven designs focus on the human primarily as a source of failure. Designs intended to support or replace humans often fail to acknowledge or understand the capabilities that humans routinely contribute to successful performance. Consequently, designs intended to “protect” the system from “error-prone” humans can design-out the capability for the human to effectively intervene or adapt. The development of paradigms to study successful human performance represents a significant and largely untapped opportunity for research in cognition.

Jon Holbrook↗

A New Ablative Heat Shield Sensor Suite Project

A new sensor suite is developed to measure performance of ablative thermal protection systems used in planetary entry vehicles for robotic and human exploration. The new sensor suite measures ablation of the thermal protection system under extreme heating encountered during planetary entry. The sensor technology is compatible with a variety of thermal protection materials, and is applicable over a wide range of entry conditions.

Thermal Protection↗

Analysis of Aircraft Control Performance using a Fuzzy Rule Base Representation of the Cooper-Harper Aircraft Handling Quality Rating

The Cooper-Harper rating of Aircraft Handling Qualities has been adopted as a standard for measuring the performance of aircraft since it was introduced in 1966. Aircraft performance, ability to control the aircraft, and the degree of pilot compensation needed are three major key factors used in deciding the aircraft handling qualities in the Cooper- Harper rating. We formulate the Cooper-Harper rating scheme as a fuzzy rule-based system and use it to analyze the effectiveness of the aircraft controller. The automatic estimate of the system-level handling quality provides valuable up-to-date information for diagnostics and vehicle health management. Analyzing the performance of a controller requires a set of concise design requirements and performance criteria. Ir, the case of control systems fm a piloted aircraft, generally applicable quantitative design criteria are difficult to obtain. The reason for this is that the ultimate evaluation of a human-operated control system is necessarily subjective and, with aircraft, the pilot evaluates the aircraft in different ways depending on the type of the aircraft and the phase of flight. In most aerospace applications (e.g., for flight control systems), performance assessment is carried out in terms of handling qualities. Handling qualities may be defined as those dynamic and static properties of a vehicle that permit the pilot to fully exploit its performance in a variety of missions and roles. Traditionally, handling quality is measured using the Cooper-Harper rating and done subjectively by the human pilot. In this work, we have formulated the rules of the Cooper-Harper rating scheme as fuzzy rules with performance, control, and compensation as the antecedents, and pilot rating as the consequent. Appropriate direct measurements on the controller are related to the fuzzy Cooper-Harper rating system: a stability measurement like the rate of change of the cost function can be used as an indicator if the aircraft is under control; the tracking error is a good measurement for performance needed in the rating scheme. Finally, the change of the control amount or the output of a confidence tool, which has been developed by the authors, can be used as an indication of pilot compensation. We use a number of known aircraft flight scenarios with known pilot ratings to calibrate our fuzzy membership functions. These include normal flight conditions and situations in which partial or complete failure of tail, aileron, engine, or throttle occurs.

Tseng, Chris↗

Stable Chlorine Isotope Measurements of Astromaterials Using the Cs-Sputter Negative Ion Source of an Accelerator Mass Spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35Cl and 37Cl. Chlorine isotope variations (reported as δ37Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) [1] are documented to exceed 80‰ [2] between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history[3,4].The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements (Figure 1).This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ37Cl measurements using the Cs-sputter negative ion source of an existing accelerator mass spectrometer. A brief description of the methods used for this work is followed by the results of our δ37Cl measurements and a discussion of the technique’s possible applications.

Chlorine↗

Development Towards Stable Chlorine Isotope Measurements of Astromaterials Using the Modified Middleton Source of an Accelerator Mass Spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35Cl and 37Cl. Chlorine isotope variations (reported as δ37Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) are documented to exceed 80‰ between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history. The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements. This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ37Cl measurements using the modified Middleton ion source of an existing accelerator mass spectrometer. For samples with as little as 1 μg Cl–the equivalent of 2–4 mm3 of a typical lunar rock sample–the average cathode accuracy is ∼1‰. Cathode reproducibility is typically ∼1‰ (2σ) for samples with at least 10 μg of Cl, increasing to ∼3–6‰ for aliquots with ∼1–2 μg Cl, similar to published SIMS results and sufficient to study astromaterials from the Moon, Mars, or 4 Vesta, which have tens of ‰ observed variations.

Tyler S. Anderson↗

Autonomous Image Processing Algorithms Locate Region-of-Interests: The Mars Rover Application

In this report, we demonstrate that bottom-up IPA's, image-processing algorithms, can perform a new visual task to select and locate Regions-Of-Interests (ROIs). This task has been defined on the basis of a theory of top-down human vision, the scanpath theory. Further, using measures, Sp and Ss, the similarity of location and ordering, respectively, developed over the years in studying human perception and the active looking role of eye movements, we could quantify the efficient and efficacious manner that IPAs can imitate human vision in located ROIS. The means to quantitatively evaluate IPA performance has been an important part of our study. In fact, these measures were essential in choosing from the initial wide variety of IPAS, that particular one that best serves for a type of picture and for a required task. It should be emphasized that the selection of efficient IPAs has depended upon their correlation with actual human chosen ROIs for the same type of picture and for the same required task accomplishment.

Privitera, Claudio↗