Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Assessment of drug-induced arrhythmic risk using limit cycle and autocorrelation analysis of human iPSC-cardiomyocyte contractility

Cardiac safety assays incorporating label-free detection of human stem-cell derived cardiomyocyte contractility provide human relevance and medium throughput screening to assess compound-induced cardiotoxicity. In an effort to provide quantitative analysis of the large kinetic datasets resulting from these real-time studies, we applied bioinformatic approaches based on nonlinear dynamical system analysis, including limit cycle analysis and autocorrelation function, to systematically assess beat irregularity. The algorithms were integrated into a software program to seamlessly generate results for 96-well impedance-based data. Our approach was validated by analyzing dose- and time-dependent changes in beat patterns induced by known proarrhythmic compounds and screening a cardiotoxicity library to rank order compounds based on their proarrhythmic potential. We demonstrate a strong correlation for dose-dependent beat irregularity monitored by electrical impedance and quantified by autocorrelation analysis to traditional manual patch clamp potency values for hERG blockers. In addition, our platform identifies non-hERG blockers known to cause clinical arrhythmia. Our method provides a novel suite of medium-throughput quantitative tools for assessing compound effects on cardiac contractility and predicting compounds with potential proarrhythmia and may be applied to in vitro paradigms for pre-clinical cardiac safety evaluation. - Highlights: • Impedance-based monitoring of human iPSC-derived cardiomyocyte contractility • Limit cycle analysis of impedance data identifies aberrant oscillation patterns. • Nonlinear autocorrelation function quantifies beat irregularity. • Identification of hERG and non-hERG inhibitors with known risk of arrhythmia • Automated software processes limit cycle and autocorrelation analyses of 96w data.

60 APPLIED LIFE SCIENCES↗

Advances in image compression and automatic target recognition; Proceedings of the Meeting, Orlando, FL, Mar. 30, 31, 1989

Various papers on image compression and automatic target recognition are presented. Individual topics addressed include: target cluster detection in cluttered SAR imagery, model-based target recognition using laser radar imagery, Smart Sensor front-end processor for feature extraction of images, object attitude estimation and tracking from a single video sensor, symmetry detection in human vision, analysis of high resolution aerial images for object detection, obscured object recognition for an ATR application, neural networks for adaptive shape tracking, statistical mechanics and pattern recognition, detection of cylinders in aerial range images, moving object tracking using local windows, new transform method for image data compression, quad-tree product vector quantization of images, predictive trellis encoding of imagery, reduced generalized chain code for contour description, compact architecture for a real-time vision system, use of human visibility functions in segmentation coding, color texture analysis and synthesis using Gibbs random fields.

Tescher, Andrew G.↗

Twentieth-century hydroclimate changes consistent with human influence

Although anthropogenic climate change is expected to have caused large shifts in temperature and rainfall, the detection of human influence on global drought has been complicated by large internal variability and the brevity of observational records. Furthermore we address these challenges using reconstructions of the Palmer drought severity index obtained with data from tree rings that span the past millennium. We show that three distinct periods are identifiable in climate models, observations and reconstructions during the twentieth century. In recent decades (1981 to present), the signal of greenhouse gas forcing is present but not yet detectable at high confidence. Observations and reconstructions differ significantly from an expected pattern of greenhouse gas forcing around mid-century (1950–1975), coinciding with a global increase in aerosol forcing. In the first half of the century (1900–1949), however, a signal of greenhouse-gas-forced change is robustly detectable. Multiple observational datasets and reconstructions using data from tree rings confirm that human activities were probably affecting the worldwide risk of droughts as early as the beginning of the twentieth century.

54 ENVIRONMENTAL SCIENCES↗

Operator-in-the-Loop Study for a Computerized Operator Support System (COSS) – Cross-System and System-Independent Evaluations

The Computerized Operator Support System (COSS) is an operator assistive technology funded by the U.S. Department of Energy Office of Nuclear Energy and developed at Idaho National Laboratory. The project works in collaboration with an advanced prognostics system called PRO-AID developed at Argonne National Laboratory. The COSS provides a human-machine interface to help operators maintain situation awareness and detect faults earlier than would be possible using conventional control room technologies at nuclear power plants. This report represents a status report outlining third-year efforts to develop and validate the COSS. The COSS has now been implemented as a prototype system, with multiple interaction design concepts on multiple plant systems in the simulator from a commercial nuclear power plant. Two studies involving three licensed reactor crews were conducted to evaluate the COSS. This report captures insights into the development of COSS as well as operator feedback and future development guidance derived from the operator-in-the-loop simulator studies.

99 GENERAL AND MISCELLANEOUS↗

Using populations of human and microbial genomes for organism detection in metagenomes

Identifying causative disease agents in human patients from shotgun metagenomic sequencing (SMS) presents a powerful tool to apply when other targeted diagnostics fail. Numerous technical challenges remain, however, before SMS can move beyond the role of research tool. Accurately separating the known and unknown organism content remains difficult, particularly when SMS is applied as a last resort. The true amount of human DNA that remains in a sample after screening against the human reference genome and filtering nonbiological components left from library preparation has previously been underreported. In this study, we create the most comprehensive collection of microbial and reference-free human genetic variation available in a database optimized for efficient metagenomic search by extracting sequences from GenBank and the 1000 Genomes Project. The results reveal new human sequences found in individual Human Microbiome Project (HMP) samples. Individual samples contain up to 95% human sequence, and 4% of the individual HMP samples contain 10% or more human reads. In conclusion, left unidentified, human reads can complicate and slow down further analysis and lead to inaccurately labeled microbial taxa and ultimately lead to privacy concerns as more human genome data is collected.

59 BASIC BIOLOGICAL SCIENCES↗

Telomerase Structure Paves the way for New Cancer Therapies

Inappropriate activation of a single enzyme, telomerase, is associated with the uncontrollable proliferation of cells observed in as many as 90% of all of human cancers. Since the mid-1990s, when telomerase activity was detected in human tumors, scientists have eyed the enzyme as an ideal target for developing broadly effective anticancer drugs. One of the missing links in the effort to identify such therapies has been the high-resolution structure of the enzyme, a powerful tool used for the identification and development of clinical drugs. A recent structure of the catalytic subunit of teleomerase from the Skordalakes laboratory, a major advancement in the field of telomeres, has opened the door to the development of new, broadly effective cancer drugs, as well as anti-aging therapies. Here we present a brief description of telomerase biology, current efforts to identify telomerase function modulators and the potential importance of the telomerase structure in future drug development.

59 BASIC BIOLOGICAL SCIENCES↗

Identification and interpretation of patterns in rocket engine data

The goal of our research is to analyze ground test data, to identify patterns associated with the anomalous engine behavior. On the basis of this analysis, it is the task of our project to develop a Pattern Identification and Detection System which detects anomalous engine behavior in the early stages of fault development significantly earlier than the indication provided by either redline detection mechanism or human expert analysis. Early detection of these anomalies is challenging because of the large amount of noise presence in the data. In the presence of this noise, early indication of anomalies becomes even more difficult to distinguish from fluctuations in normal steady state operation.

Lo, Ching F.↗

On the quantitative evaluation of edge detection schemes and their comparison with human performance

A technique for the quantitative evaluation of edge detection schemes is presented. It is used to assess the performance of three such schemes using a specially-generated set of images containing noise. The ability of human subjects to distinguish the edges in the presence of noise is also measured and compared with that of the edge detection schemes. The edge detection schemes are used on a high-resolution satellite photograph with varying degrees of noise added in order to relate the quantitative comparison to real-life imagery.

Fram, J. R.↗

Detectability of Neuronal Currents in Human Brain with Magnetic Resonance Spectroscopy.

Magnetic resonance spectroscopy has been used in a high-risk, high-payoff search for neuronal current (NC) signals in the free induction decay (FID) data from the visual cortex of human subjects during visual stimulation. If successful, this approach could make possible the detection of neuronal currents in the brain at high spatial and temporal resolution. Our initial experiments indicated the presence of a statistically significant change in the FID containing the NC relative to FIDs with the NC absent, and this signal was consistent with the presence of NC. Unfortunately, two follow-on experiments were not able to confirm or replicate the positive findings of the first experiment. However, even if the result from the first experiment were evidence of NC in the FID, it is clear that its effect is so small, that a true NC imaging experiment would not be possible with the current instrumentation and experimental protocol used here.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GraphCH: A Deep Framework for Assessing Cyber-Human Aspects in Insider Threat Detection

Insider threat is one of the most damaging cyber attacks that could cause the loss of intellectual property and enterprise data security breaches. Action sequence data such as host logs are used to investigate such threats and develop anomaly-based AI detectors. However, insider threat actions are similar to legitimate user activities, causing AI detectors to fail and suffer from high false alarm rates. Therefore, user cyber activity logs are inadequate to fully unfold insider threats. In this study, we adopt human psychological principles of risk-taking and impulsiveness along with host data to assess the influence and usefulness of human behavioral aspects in insider threat detection. Here, we hypothesize that individuals' impulsive and risk-taking behavior correlates with cyberspace activities. To validate our hypothesis, we conducted an IRB-approved study recruiting 35 participants who work in a large U.S. university and collected their cyber and psychological data for 90 days. Host and human-behavioral data analysis and mapping indicate that impulsive and risk-taking users trigger more system errors causing (un)intentional insider threats and are susceptible to attackers' social engineering and cognitive hacking. Utilizing cyber-human aspects, we introduce a Cyber-Human Graph Neural Network (GNN) based framework GraphCH to identify abnormal user behaviors and detect insider threats.

97 MATHEMATICS AND COMPUTING↗

On the Notional Impact of Background Noise on the Human Response to UAVs

Proponents of UAV-based industries would like to think that their aircraft will be incapable of causing annoyance (among other negative responses) in the communities that they serve due to the noise of their vehicles simply not being heard over the existing soundscape. No measures of noise that are in wide use today for aviation take background sound into consideration, and thus would not predict this outcome. This work is an attempt to bridge this gap by looking at past results from psychoacoustic research in which background sounds appear to play a significant role (not just for aviation sources). It includes information on the problem of human auditory detection in general – what is the transductive mechanism of the ear, how does one quantify detectability, etc., and it attempts to make the connection between detectability and annoyance. A notional schematic version of how measures/predictions of these two aspects may be incorporated into a single assessment of noise is given. Overall, detectability is shown to be very complex to predict relative to conventional noise metrics that are used to correlate with human response. Given this, the outlook for the use of measures of detectability in scientific, industrial, and regulatory applications is discussed.

UAV↗

Bisphenol A sulfonation is impaired in metabolic and liver disease

Background: Bisphenol A (BPA) is a widely used industrial chemical and suspected endocrine disruptor to which humans are ubiquitously exposed. The liver metabolizes and facilitates BPA excretion through glucuronidation and sulfonation. The sulfotransferase enzymes contributing to BPA sulfonation (detected in human and rodents) is poorly understood. Objectives: To determine the impact of metabolic and liver disease on BPA sulfonation in human and mouse livers. Methods: The capacity for BPA sulfonation was determined in human liver samples that were categorized into different stages of metabolic and liver disease (including obesity, diabetes, steatosis, and cirrhosis) and in livers from ob/ob mice. Results: In human liver tissues, BPA sulfonation was substantially lower in livers from subjects with steatosis (23%), diabetes cirrhosis (16%), and cirrhosis (18%), relative to healthy individuals with non-fatty livers (100%). In livers of obese mice (ob/ob), BPA sulfonation was lower (23%) than in livers from lean wild-type controls (100%). In addition to BPA sulfonation activity, Sult1a1 protein expression decreased by 97% in obese mouse livers. Conclusion: Taken together these findings establish a profoundly reduced capacity of BPA elimination via sulfonation in obese or diabetic individuals and in those with fatty or cirrhotic livers versus individuals with healthy livers. - Highlights: • Present study demonstrates that hepatic SULT 1A1/1A3 are primarily sulfonate BPA in mouse and human. • Hepatic BPA sulfonation is profoundly reduced steatosis, diabetes and cirrhosis. • With BPA-S detectable in urine under low or common exposures, these findings are novel and important.

60 APPLIED LIFE SCIENCES↗

Hybrid printing of wearable piezoelectric sensors

Piezoelectricity provides an ideal electromechanical mechanism with emerging applications in wearable devices due to its simplicity and self-powered nature. However, the 3D printing of piezoelectric devices still faces many challenges, including material printability, high energy poling process, and low dimensional accuracy. This study demonstrates, for the first time, a tellurium nanowire-based piezoelectric device fabricated by a hybrid printing method integrating highly complementary aerosol jet printing and extrusion printing in a single printing platform. The aerosol-jet-printed tellurium nanowire demonstrates piezoelectric properties without the need for any poling processing due to the unique properties of the tellurium nanowires. The silver nanowire electrodes printed by aerosol jet printing demonstrate excellent conductivity and stretchability without the need for sintering. An extrusion method is employed to print the silicone films, which serve as the stretchable substrate and the electrical insulation layers between the printed tellurium and silver. The printed wearable piezoelectric devices were attached to a human wrist to detect different hand gestures and to a human neck to detect heartbeat without using an external power source. In conclusion, the fully printed, sintering-free and poling-free, and stretchable piezoelectric device opens enormous opportunities for facile integration with a broad range of printed electronics and wearable devices.

47 OTHER INSTRUMENTATION↗

Protective effect of nuclear factor E2-related factor 2 on inflammatory cytokine response to brominated diphenyl ether-47 in the HTR-8/SVneo human first trimester extravillous trophoblast cell line

Polybrominated diphenyl ethers (PBDEs) are widely used flame retardants, and BDE-47 is a prevalent PBDE congener detected in human tissues. Exposure to PBDEs has been linked to adverse pregnancy outcomes in humans. Although the underlying mechanisms of adverse birth outcomes are poorly understood, critical roles for oxidative stress and inflammation are implicated. The present study investigated antioxidant responses in a human extravillous trophoblast cell line, HTR-8/SVneo, and examined the role of nuclear factor E2-related factor 2 (Nrf2), an antioxidative transcription factor, in BDE-47-induced inflammatory responses in the cells. Treatment of HTR-8/SVneo cells with 5, 10, 15, and 20 μM BDE-47 for 24 h increased intracellular glutathione (GSH) levels compared to solvent control. Treatment of HTR-8/SVneo cells with 20 μM BDE-47 for 24 h induced the antioxidant response element (ARE) activity, indicating Nrf2 transactivation by BDE-47 treatment, and resulted in differential expression of redox-sensitive genes compared to solvent control. Pretreatment with tert-butyl hydroquinone (tBHQ) or sulforaphane, known Nrf2 inducers, reduced BDE-47-stimulated IL-6 release with increased ARE reporter activity, reduced nuclear factor kappa B (NF-κB) reporter activity, increased GSH production, and stimulated expression of antioxidant genes compared to non-Nrf2 inducer pretreated groups, suggesting that Nrf2 may play a protective role against BDE-47-mediated inflammatory responses in HTR-8/SVneo cells. These results suggest that Nrf2 activation significantly attenuated BDE-47-induced IL-6 release by augmentation of cellular antioxidative system via upregulation of Nrf2 signaling pathways, and that Nrf2 induction may be a potential therapeutic target to reduce adverse pregnancy outcomes associated with toxicant-induced oxidative stress and inflammation. - Highlights: • BDE-47 stimulated ARE reporter activity and GSH production. • BDE-47 resulted in differential expression of redox-sensitive genes. • Nrf2 inducers upregulated Nrf2-mediated oxidative stress responses. • Nrf2 inducers reduced BDE-47-stimulated IL-6 release and NF-κB activity.

60 APPLIED LIFE SCIENCES↗

Carbon Nanostructures in Biological Sensors for Space and Terrestrial Applications

Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.

carbon nanotubes↗

Carbon Nanomaterials for Biosensing Applications

Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.

carbon nanotubes↗

Detecting Faults By Use Of Hidden Markov Models

Frequency of false alarms reduced. Faults in complicated dynamic system (e.g., antenna-aiming system, telecommunication network, or human heart) detected automatically by method of automated, continuous monitoring. Obtains time-series data by sampling multiple sensor outputs at discrete intervals of t and processes data via algorithm determining whether system in normal or faulty state. Algorithm implements, among other things, hidden first-order temporal Markov model of states of system. Mathematical model of dynamics of system not needed. Present method is "prior" method mentioned in "Improved Hidden-Markov-Model Method of Detecting Faults" (NPO-18982).

Smyth, Padhraic J.↗