Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Dirty dishes or dirty laundry? Comparing two methods for quantifying American consumers' preferences for load management in a smart home

One challenge of transitioning to renewable energy is that household electricity use and renewable generation are often misaligned. Smart home energy management systems hold promise for shifting usage to match generation, but these systems need to be designed with the occupants’ preferences in mind. The purpose of the present research is to compare two approaches for collecting and modeling consumers’ load management preferences, both of which are amenable to use in a home energy management system. Specifically, we examine the performance of Simple Multi-Attribute Rating Technique Exploiting Ranks (SMARTER) and Analytic Hierarchy Process (AHP) in quantifying consumers’ preferences regarding air temperature (air conditioning and heating), water heating, dishwashing, clothes washing and drying, monetary costs, environmental impacts, and comfort/convenience. Two studies are presented: Study 1 examines the SMARTER approach, and Study 2 focuses on the AHP approach. In both studies, online surveys (N SMARTER = 956 and N AHP = 1023) were conducted to elicit preferences from participants across the United States. The preferences modeled by both approaches were validated based on (a) their ability to predict participants’ choices in a Discrete Choice Experiment and (b) their convergence with previous research on load-shifting behavior. The validation procedure suggests that the SMARTER approach is superior in modeling consumers’ preferences for load management. Overall, this research lays the groundwork for designing a smart home interface capable of collecting occupants’ preferences and using those preferences to deliver improved occupant comfort, lower operating costs, reduced environmental impact, and more significant demand response than exists today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ground Source Heat Pump Screening Tool and Related Resources

This archive contains both a link to Oak Ridge National Laboratory's Ground Source Heat Pump (GSHP) Screening Tool and related resources documenting its development, technical features, and applications. The web-based screening tool is a techno-economic analysis resource designed to evaluate the feasibility, costs, and benefits of implementing GSHP systems in buildings across various U.S. climate zones. It is intended for use by building owners, HVAC system designers, and installers to support decision-making in residential and commercial applications, incorporating advanced modeling capabilities such as ground heat exchanger design. The included resources detail the tool's creation and use, covering topics such as innovative ground heat exchanger design methodologies, the development of an open library of g-functions for borehole configurations, and studies on GSHP performance and economic viability in retrofitting single-family homes.

15 GEOTHERMAL ENERGY↗

Final Technical Report

Statement of the problem or situation that is being addressed in your application. The DOE and its national laboratories developed the Home Energy Score™ (HES) to encourage homeowners to improve their energy performance, lower costs and to share energy information through the MLS listing, appraisal, and financing channels. While the HES is an instrumental tool, it is currently underutilized and consists of technical, structural and sector barriers which need to be addressed in order to scale and many energy efficiency contractors are understandably overwhelmed by the added time and effort and lack of incentive to sell and deliver deep retrofit projects while simultaneously meeting the DOE HES program requirements; consequently, contractors may decide to forgo participation. Home Energy Rating System (HERS) Raters have the opportunity to play the critical Assessor role in producing a Home Energy Score (HES); this role has immense potential but currently is unfulfilled. Lastly, while utilities are interested in their customer base achieving greater energy efficiency, especially to help offset growing residential loads in states like California that are accelerating electrification, utilities do not have access to the market actors who are on the front line of influence to homeowners or review and approve their permits: HERS Raters, assessors, contractors and building departments. General statement of how this problem is being addressed: ConSol will integrate the Home Energy Score™ (HES) to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California (CHEERS+HES). The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the utilities in supporting existing homes in their jurisdictions with HES and develop measures to improve energy efficiency and reduce emissions. How is this problem being addressed? What is the overall project approach? In effort to expand the Home Energy Score™ (HES) by increasing the use of aggregable home energy asset data, ConSol proposes to integrate the DOE HES via Application Programming Interface (API) to its State of California approved home energy rating services platform (CHEERS). Once the CHEERS platform and HES are integrated (CHEERS+HES), this enhanced platform will be instantly available and actively deployed via Phase 1 pilot to HERS Raters, assessors and contractors in California to market-test the solution, understand the rate of adoption and identify opportunities for improvement prior to scaling nationally. The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the building industry and homeowners with an easy-to-use assessment if energy and carbon impacts of existing homes, and assist the utilities in supporting existing homes in their jurisdictions with HES to improve energy efficiency and reduce emissions. What is to be done in Phase I? During Phase I of this proposed project, ConSol will (1) design software architecture that links CHEERS to the Home Energy ScoreTM via API, (2) solicit partnership from one or more California utilities for a regional pilot, (3) test the new software with its HERS Raters and contractor network in the partnership utility jurisdiction, (4) launch a pilot version of the newly developed software with HERS Raters and contractors in the utility territory, and (5) explore California’s GoGreen energy efficiency homeowner lending program in parallel with the pilot. Commercial Applications and Other Benefits. Summarize the future applications or public benefits if the project is carried over into Phase II or Phase III and beyond. The CHEERS+HES commercialized product will be ready for national market scale following a successful Phase 1 performance. The CHEERS+HES adoption is estimated to reach a 5% adoption growth rate versus the 110,000 baseline, starting in Year 1 after Phase I completion, and continuing each year. As a direct benefit to the DOE, CHEERS will set a goal of 100,000 Home Energy Score assessments for existing home alterations within the first 10 years following Phase 1 performance. The technical benefits of this proposed project include the harmonized, automated, and seamless integration of the DOE HES into the widely used and market leading California energy registry, CHEERS. The social benefits include the aggregate energy, cost and GHG savings by allowing the broader public streamlined access to the CHEERS+HES measurement and the energy efficiency recommended measures that may result. Key Words: Home Energy ScoreTM (HES); Application Programming Interface (API); Home Energy Rating Services (HERS); HERS Raters; contractors; assessors; existing homes, energy asset data; cost, energy, and emissions saving measures; energy code (Title 24) compliance; document repository; utilities; pilot; newly developed software; energy efficiency; homeowner. Summary for Members of Congress: The DOE Home Energy Score™ (HES) is a tool to encourage homeowners to improve their energy performance, lower costs and share energy information but is underutilized and consists of barriers which need to be addressed in order to scale. In effort to expand the HES, CHEERS, Inc. will integrate the HES to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California.

Application Programming Interface (API)↗

Low-Power, Load-Balancing Whole Home Electrification Solution: Cooperative Research and Development (Final Report)

Testing was conducted at the Systems Performance Laboratory in NREL’s Energy Systems Integration Facility to test the performance of 120V wall-mounted heat pumps, 120V heat pump water heaters (HPWH), Electric Vehicle Supply Equipment (EVSE), and other plug-in loads, using NeoCharge Smart Splitters and whole home energy software as appropriate. Four different simulated occupancy scenarios were used to evaluate the package of technology and controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

Automated fault detection of residential air-conditioning systems using thermostat drive cycles

Residential air conditioning equipment comprises a significant portion of the total energy consumption of a home. Unfortunately, air-conditioning systems can be susceptible to faulty operation either from installation errors or faults that accrue over the equipment’s lifetime. This paper presents a novel automated fault detection algorithm for residential air-conditioning systems that can alert the homeowner of the presence of these faults. The proposed algorithm utilizes only the home’s thermostat and outside air temperature to perform automated fault detection over the course of the equipment’s lifetime, including immediately after installation. The algorithm uses an extended Kalman filter approach to identify a three-resistor, two-capacitor (3R2C) electrical equivalent thermodynamic model. The identified 3R2C model is used to predict cooling times during a testing period comprising of a series of thermostat drive-cycle experiments. We tested the algorithm on an EnergyPlus™ model of a typical residential building in Orlando, Florida. Duct faults, indoor airflow faults, and refrigerant undercharge faults were introduced into the building model one at a time. The algorithm was able to accurately determine duct-leak faults, 40% airflow faults, 40% undercharge faults, and no-fault cases with an accuracy of 70%, 77%, 82%, and 87%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

Experimental Plan for the Vermiculite Study

Homes in which vermiculite, which can contain asbestos, is present are often deferred under the DOE Weatherization Assistance Program (WAP) because of uncertainty in how to safely weatherize such homes from a client and worker perspective and the potential costs associated with alternative approaches. Recognizing this situation, the Department of Energy (DOE) tasked the Oak Ridge National Laboratory (ORNL) to perform a research project that scientifically identifies the asbestos exposure risks in weatherizing homes with existing vermiculite insulation. Current approaches being used by Grantees and Subgrantees to weatherize homes with existing vermiculite insulation were identified as part of the development of this experimental plan based on a review of Grantee Health and Safety Plans and communications with weatherization program staff from seven states. Other than deferral, these approaches include the following:1.) Abating (i.e., removing) the existing vermiculite using funding sources other than WAP (e.g., state funds, utility funds, the Zonolite Attic Insulation Trust Fund, and possibly homeowner contributions) because abatement is not allowed using WAP funds per Weatherization Program Notice (WPN) 17-7. 2.) Weatherizing the house as normal after testing reveals that the vermiculite contains less than 1% asbestos. 3.) Avoiding areas of the house where vermiculite is installed and weatherizing the remaining areas of the house as normal. 4.) Encapsulating the existing vermiculite insulation in an attic by blowing cellulose or other insulation over it. 5.) Weatherizing the areas of the house where vermiculite is installed using unique/alternative approaches developed specifically for that house. Blower door testing is also impacted by the presence of vermiculite due to the concern of bringing asbestos fibers into the space. Some states address this by performing pressurized blower door tests, whereas other states prohibit blower door testing entirely when vermiculite is present. This research project will focus on gathering data on home occupant and weatherization worker exposures to asbestos before, during, and/or after the weatherization of the homes containing vermiculite insulation using five of the six approaches identified above. Abatement of the existing vermiculite insulation will not be studied because it is not allowed using WAP funding per WPN 17-7 and, thus, is not a sustainable approach for WAP.

36 MATERIALS SCIENCE↗

A New Gold Mine? Achieving HVAC Energy Efficiency Through a System Metric

Washington State's Commercial Energy Code adopted a new energy metric called HVAC Total System Performance Ratio (TSPR) in 2019, a first in the codes world to regulate HVAC system efficiency. TSPR is a ratio of annual heating and cooling loads to the annual carbon emissions associated with the energy consumed by the HVAC system. TSPR provides a performance-based solution to evaluate and improve the overall HVAC design. The TSPR metric and its companion calculation tool were developed by Pacific Northwest National Laboratory (PNNL) with support from U.S. Department of Energy (DOE), Northwest Energy Efficiency Alliance (NEEA) and the City of Seattle. The new metric represents a significant shift in how HVAC design will meet code requirements. Utility programs can also leverage TSPR as a measure to determine energy savings and incentive amounts for HVAC retrofits. This paper describes the efforts by NEEA and its collaborators to prepare the market for TSPR adoption in code. This paper provides the pilot projects led by University of Washington Integrated Design Lab (IDL) to understand potential issues that could be faced by early adopters. This paper also covers how training and outreach provide engagement opportunities that can streamline code compliance, help address issues faced by early adopters and promote participation in utility programs. As Washington State works on the goals of 70% energy reduction and zero fossil-fuel greenhouse gas emission homes and buildings by the year 2031 , system level performance metrics will likely become increasingly more necessary and prevalent. This paper concludes that the HVAC TSPR requirement helps familiarize the HVAC industry with this approach and helps Washington achieve its long-term goals.

Liu, Bing↗

Human Performance Improvement Task Group Task 21-1 Best Practice: Using virtual capabilities or options for HPI application (to reduce errors, strengthening defenses, strengthening the organization, and/or increasing capacity)

In 2020 the world was impacted by COVID-19. How work is done was dramatically changed for a large portion of the workforce. Many have made the abrupt shift to working from their home while others have adapted to COVID protocols (such as social distancing and wearing facemasks). Fundamentally, Human and Organizational Performance Improvement concepts and science did not change – only the delivery method changed (in some cases). The primary effect has been to accelerate dynamics already present in society – from e-commerce to online education to remote healthcare. Change is never easy for humans. However, remote work should be viewed as an opportunity; not a fix to a problem. In this Best Practice paper, you’ll get practical suggestions to help you reduce errors and improve Human Performance in remote, socially-distanced “work-from-home” environments.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cooperative Research and Development Agreement With Georgetown University Report: National Institutes of Health, National Center for Advancing Translational Sciences Clinical and Translational Science Award

Oak Ridge National Laboratory (ORNL) is participating with Georgetown University (GU) as a subrecipient in response to the National Institutes of Health (NIH), National Center for Advancing Translational Sciences (NCATS) Clinical and Translational Science Award (CTSA) (U54 Clinical Trial Optional) funding opportunity announcement. This Cooperative Research and Development Agreement is put in to place to facilitate the development and implementation of clinical interventions that demonstrably improve human health is currently a complex, recursive, and inefficient process that leads to delays of years or decades before discoveries in biomedical research result in health benefits for patients and communities. NCATS conducts and supports research in the science of translation, to discover the mechanistic and operational principles of the intervention development and dissemination process, thereby providing the scientific foundation for improvements in translational efficiency that will accelerate the realization of interventions that improve human health. Under NCATS’ leadership, the CTSA Program supports a national network of medical research institutions called hubs. GU is the lead institution in one of the NIH hubs that was created as a result of a previous NIH CTSA. The missions of the GU have historically included the advancement of health through research in the clinical and biomedical sciences, the education of future leaders in medical and nursing practice and academia, and the provision of compassionate and scientifically competent patient care and service to the Washington, DC community and the nation. GU is the lead institution for the Georgetown-Howard Universities Center for Clinical and Translational Science (GHUCCTS), a multi-institutional partnership of medical research institutions forged from a desire to promote clinical research and translational science. Through multiple collaborations among these institutions, GHUCCTS is transforming clinical research and translational science in order to bring new scientific advances to health care. Oak Ridge National Laboratory is the Department of Energy's (DOE) largest science and energy laboratory. Managed since April 2000 by a partnership of the University of Tennessee and Battelle, ORNL was established in 1943 as a part of the secret Manhattan Project to pioneer a method for producing and separating plutonium. During the 1950s and 1960s, ORNL became an international center for the study of nuclear energy and related research in the physical and life sciences. With the creation of DOE in the 1970s, ORNL's mission broadened to include a variety of energy technologies and strategies. Today the laboratory supports the nation with a peacetime science and technology mission that is just as important as, but very different from, its role during the Manhattan Project. ORNL is home to the world's premier center for high performance supercomputing to enable scientific discovery. ORNL has extensive expertise in various areas of computer science that are uniquely situated to support GU. Additionally, ORNL’s leading computational user facilities present a unique opportunity to leverage the largest scale machines for open science in support of the stated mission of the NCATS CTSA. ORNL's partnership with GU will offer unparalleled opportunity in data analytics, deep-learning, artificial intelligence, and urban dynamics.

59 BASIC BIOLOGICAL SCIENCES↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

This report, Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities , explores ways to automatically identify residential homes with enclosure retrofit opportunities; estimate prospective savings; and perform evaluation, measurement, and verification using interval data from communicating thermostats.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of wall assembly for DOE Efficient New Homes Program in HUD’s Climate Zones 2 and 3

Manufactured homes provide affordable housing for over 20 million Americans. The U.S. Department of Energy’s Efficient New Homes (ENH) program has introduced new energy certification requirements that manufacturers can optionally target to ensure outstanding levels of energy savings, comfort, health, and durability. In collaboration with Clayton Homes (under User Agreement (NN-23-1469)), Oak Ridge National Laboratory evaluated multiple wall assembly options to meet ENH requirements in HUD Climate Zones 2 and 3, with a target maximum cost premium of 5%. After analyzing thermal performance, cost, and manufacturability, insulated structural sheathing was identified as the most practical and effective solution. A full-scale manufactured home prototype demonstrated that this approach meets energy performance goals with minimal disruption to existing manufacturing processes and a cost premium of less than 10% with a path to further lower costs, offering a promising path forward for more efficient manufactured housing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Cost of Decarbonization and Energy Upgrade Retrofits for US Homes

Cost is a major barrier when upgrading homes to reduce carbon emissions required to meet DOE’s climate-related goals. This report summarizes a nationwide effort to gather home energy upgrade project cost data along with household energy performance data. The goal was to develop cost benchmarks and to guide future R&D efforts aimed at cost compression and scaling of the residential upgrade market. The cost data were compiled for both total project costs and costs of individual measures. The majority of energy savings were modeled, with some models using measured site data for calibration. The database was analyzed using clustering techniques to find common energy and CO2 reduction approaches. The individual measures were combined into archetypal solutions to determine least-cost approaches to maximizing energy and carbon savings. Several financial analyses were preformed to examine other cost metrics beyond first cost. Project data was obtained for 1,739 projects, from 15 states and 12 energy programs, with a total of 10,512 individual measures. The database includes a wide-array of projects, ranging from single-measure HVAC upgrades to net-zero energy whole home remodels. Projects were predominantly single-family detached dwellings with wood frame construction. Most of the data was obtained from energy programs because they had recorded the necessary information and were willing to share with this study. This sample of convenience can provide broad guidance and national cost benchmarks, but lacks sufficient detail to draw more disaggregated conclusions, such as geographical trends. The majority of data contributions were obtained without compensation from sources where the required data was already in some sort of structured format. We compensated sources to enter data from individual projects into a structured data format for about 500 projects, with an average cost of about $40 per project. The database was highly skewed to lower cost, lower impact projects due to the nature of the sample of convenience. Less than 10% of projects had savings greater than 50%. The cost data for individual measures in the database are being used in other DOE efforts on residential energy use/decarbonization. This data collection effort should continue in order to provide the best-informed guidance for DOE and industry R&D, as well as deployment efforts (including policy and program planning).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cold Climate Air-Source Heat Pump Demonstration and Analysis: Experimental Study on Cold Temperature Performance

Space heating energy is the largest end use for U.S. residential buildings, accounting for nearly 45% of residential building energy consumption nationwide, and approximately 51% of space heating energy is consumed on-site by combusting natural gas (EIA 2020a). In Colorado, approximately 53% of the statewide residential building energy consumption goes to space heating, 76% of which is provided by natural gas (EIA 2020a). Heat pumps are an efficient, electric alternative space heating technology and have been proven viable for decades. However, historically air-source heat pumps (ASHPs) have been limited to temperate climates because of (1) subpar performance at extremely cold outdoor air temperatures, (2) the need for air conditioning in summer months, and (3) the availability of natural gas in colder climates. Relatively recent advances to cold climate ASHP technology, which typically relies on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance, enabling the technology to potentially save energy for many homes in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity Analysis of Occupant Preferences on Energy Usage in Residential Buildings: Preprint

Residential buildings, accounting for 37% of the total electricity consumption in the United States, are suitable for demand-side management (DSM) programs to support effective and economical operation of the power system. A home energy management system (HEMS) enables residential buildings to participate in such programs. It is important to account for occupant preferences in HEMS to ensure occupant satisfaction while participating in DSM programs. For example, people who prefer a higher thermal comfort level are likely to consume more energy. In this study, we used foresee™, a HEMS developed by the National Renewable Energy Lab (NREL), to perform a sensitivity analysis of occupant preferences with the following objectives: minimize utility cost, minimize carbon footprint, and maximize thermal comfort. To incorporate the preferences into the HEMS, the SMARTER method was used to derive a set of weighting factors for each objective. We performed week-long building energy simulations using a model of a home in Fort Collins, Colorado, where there is mandatory time-of-use electricity rate structure. The foreseeTM HEMS was used to control the home with six different sets of occupant preferences. The study shows that occupant preferences can have a significant impact and is important to consider when modeling residential buildings. Results show that the HEMS could achieve energy reduction ranging from 3% to 21%, cost savings ranging from 5% to 24%, and carbon emission reduction ranging from 3% to 21%, while maintaining a low thermal discomfort level ranging from 0.78 K-hour to 6.47 K-hour in a one-week period during winter. These outcomes quantify the impact of varying occupant preferences and will be useful for controlling the electrical grid and developing HEMS solutions.

carbon footprint↗

Analysis of predicted mean vote-based model predictive control for residential HVAC systems

Model Predictive Control (MPC) is an advanced process control method that has attracted much attention in building heating, ventilation, and air conditioning (HVAC) systems. Here, this paper analyzes the optimal precooling performance in residential buildings using MPC with two different comfort indices, namely, temperature and predicted mean vote (PMV). It first formulates, for each comfort index, an optimization problem that accounts for different factors, such as weather, home thermal condition, prediction horizon, time-of use (TOU) utility rate, and rated cooling capacity. The problem is then solved, resulting in an MPC strategy that determines the HVAC on/off control signal and minimizes energy cost over a receding time horizon while maintaining thermal comfort. The energy performance difference between temperature-based and PMV-based MPC strategies is subsequently investigated, especially in light of the interior wall surface temperature and under different combinations of the factors. Extensive simulation results demonstrated that the proposed MPC strategies are adaptive and their performances depend primarily on weather, home thermal condition, and prediction horizon, while the impact of TOU utility rate and rated cooling capacity is relatively small. Because the PMV-based MPC strategy can take advantage of the lower interior wall surface temperature due to precooling, it resulted in 8–45% cost savings for the scenarios investigated and an average increase of 0.042–0.113 in the absolute value of the PMV index compared to the temperature-based MPC strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗