Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High Voltage EEE Parts for EMA/EHA Applications on Manned Launch Vehicles

The objective of this paper is an assessment of high voltage electronic components required for high horsepower electric thrust vector control (TVC) systems for human spaceflight launch critical application. The scope consists of creating of a database of available Grade 1 electrical, electronic and electromechanical (EEE) parts suited to this application, a qualification path for potential non-Grade 1 EEE parts that could be used in these designs, and pathfinder testing to validate aspects of the proposed qualification plan. Advances in the state of the art in high power electric power systems enable high horsepower electric actuators, such as the electromechnical actuator (EMA) and the electro-hydrostatic actuator (EHA), to be used in launch vehicle TVC systems, dramaticly reducing weight, complexity and operating costs. Designs typically use high voltage insulated gate bipolar transistors (HV-IGBT). However, no Grade 1 HV-IGBT exists and it is unlikely that market factors alone will produce such high quality parts. Furthermore, the perception of risk, the lack of qualification methodoloy, the absence of manned space flight heritage and other barriers impede the adoption of commercial grade parts onto the critical path. The method of approach is to identify high voltage electronic component types and key parameters for parts currently used in high horsepower EMA/EHA applications, to search for higher quality substitutes and custom manufacturers, to create a database for these parts, and then to explore ways to qualify these parts for use in human spaceflight launch critical application, including grossly derating and possibly treating hybrid parts as modules. This effort is ongoing, but results thus far include identification of over 60 HV-IGBT from four manufacturers, including some with a high reliability process flow. Voltage ranges for HV-IGBT have been identified, as has screening tests used to characterize HV-IGBT. BSI BS ISO 21350 Space systems Off-the-shelf item utilization, developed from Marshall Work Instruction MWI8060.1 OFF-THE-SHELF HARDWARE UTILIZATION IN FLIGHT HARDWARE DEVELOPMENTwas found to provide guidance for including commercial off-the-shelf (COTS) hardware for use in critical applications.

Griffin, Trent↗

Kinetically Dormant Ni‐Rich Layered Cathode During High‐Voltage Operation

Abstract The degradation of Ni‐rich cathodes during long‐term operation at high voltage has garnered significant attention from both academia and industry. Despite many post‐mortem qualitative structural analyses, precise quantification of their individual and coupling contributions to the overall capacity degradation remains challenging. Here, by leveraging multiscale synchrotron X‐ray probes, electron microscopy, and post‐galvanostatic intermittent titration technique, the thermodynamically irreversible and kinetically reversible capacity loss is successfully deconvoluted in a polycrystalline LiNi 0.83 Mn 0.1 Co 0.07 O 2 cathode during long‐term charge/discharge cycling in full cell configuration. Contradicting the dramatic capacity loss, the layered structure remains highly alive even after 1000 cycles at 4.6 V while undergoing a three‐order of magnitude reduction in the mass transfer kinetics, leading to almost fully recoverable capacity under kinetic‐free conditions. Such kinetic dormant behavior after cycling is not simply ascribed to poor chemical diffusion by reconstructed cathode surface but highly synchronizes with the lattice strain evolution stemming from the structural heterogeneity between deeply delithiated layered and degraded rock‐salt phases at high voltage. These findings deepen the degradation mechanism of high‐voltage cathodes to achieve long‐cycling and fast‐charging performance.

36 MATERIALS SCIENCE↗

Detecting Faults In High-Voltage Transformers

Simple fixture quickly shows whether high-voltage transformer has excessive voids in dielectric materials and whether high-voltage lead wires too close to transformer case. Fixture is "go/no-go" indicator; corona appears if transformer contains such faults. Nests in wire mesh supported by cap of clear epoxy. If transformer has defects, blue glow of corona appears in mesh and is seen through cap.

Blow, Raymond K.↗

LDEF Space Plasma-High Voltage Drainage Experiment post-flight results

The Space Plasma-High Voltage Drainage Experiment (SP-HVDE) was comprised of two identical experimental trays. With one tray located on the leading (ram facing, B10) edge and the other located on the trailing (wake facing, D4) edge of the Long Duration Exposure Facility (LDEF), it was possible to directly compare the effects of ram and wake spacecraft environments on charged dielectric materials. Six arrays of Kapton dielectric samples of 2 mil, 3 mil, and 5 mil thicknesses maintained at +/- 300, +/- 500, and +/- 1000 voltage bias formed the experimental matrix of each tray. In addition, each tray carried two solar cell strings, one biased at +300 volts and the other at -300 volts, to study current leakage from High Voltage Solar Arrays (HVSA). The SP-HVDE provides the first direct, long-term, in-flight measurements of average leakage current through dielectric materials under electric stress. The experiment also yields information on the long term stability of the bulk dielectric properties of such materials. Data and findings of the SP-HVDE are an extension of those from shorter term flight experiments such as the PIX-1 (Plasma Interaction Experiment) and PIX-2 and are therefore valuable in the design and evaluation of long-lived space systems with high voltage systems exposed to the low earth orbital environment. A summary of the SP-HVDE post flight analysis final report delivered to the LDEF Project Office under contract to the National Aeronautics and Space Administration is presented.

Yaung, J. Y.↗

Electrometer system measures nanoamps at high voltage

Floating electrometer eliminates major source of error since any leakage from electrometer case, which is at high voltage, appears only as load on high voltage supply and not as part of current being measured. Commands to and data from floating electrometer are transferred across high voltage interface by means of optical channels.

Sturman, J. C.↗

Electrolyte-driven interphase stabilization in high-voltage sodium-ion full cells

Sodium-ion batteries with a high-voltage O3-type layered oxide cathode paired with a hard carbon anode can offer high energy density; however, significant interfacial instabilities driven by electrode/electrolyte reactions limit a broader industrial adoption. Localized high concentration electrolytes (LHCEs) are a rational choice as they promote salt decomposition over solvent, forming stable, inorganic-rich electrode-electrolyte interphases (EEIs). We present here a comparison of high-voltage (4.2 V) hard carbon | NaNi 1/3 Fe 1/3 Mn 1/3 O 2 pouch cells in LHCEs and in a standard carbonate-based electrolyte by (i) examining the influence of diluent choice on the electrochemical performance of LHCEs and (ii) investigating how the electrolyte chemistry affects the composition and structure of EEIs formed. Importantly, LHCEs demonstrate superior electrochemical performance, achieving 37% higher capacity after 200 cycles (119 vs. 87 mA h g -1 ) compared to the carbonate-based electrolyte. The enhanced stabilization provided by LHCEs at the interface with high-voltage sodium layered oxide cathode is revealed by gas evolution measurements obtained through online electrochemical mass spectrometry (OEMS). Time-of-flight secondary ion mass spectrometry paired with focused ion beam and advanced statistical analyses reveal that the superior performance of LHCE stems from a robust, thin cathode electrolyte interphase formed on the sodium layered oxide cathode and a homogeneous solid electrolyte interphase formation on the hard carbon anode. Furthermore, this study highlights the critical importance of electrolyte design in interphase stabilization, which plays a key role in advancing sodium-ion batteries toward commercial viability.

25 ENERGY STORAGE↗

Electro-Optical High-Voltage Sensors

Electro-optical sensors for measuring high voltages developed for use in automatically controlled power-distribution systems. Sensors connected to optoelectronic interrogating equipment by optical fibers. Because sensitive material and optical fibers are all dielectric, no problem in electrically isolating interrogating circuitry from high voltage, and no need for voltage dividers. Sensor signals transmitted along fibers immune to electromagnetic noise at radio and lower frequencies.

Gottsche, Allan↗

Electrochemical reactivity and passivation of organic electrolytes at spinel MgCrMnO 4 cathode interfaces for rechargeable high voltage magnesium-ion batteries

Magnesium transition metal oxides such as MgCr 2−x Mn x O 4 are promising high-voltage and high-capacity cathode materials for rechargeable magnesium batteries (RMBs). Understanding and improving the chemical and electrochemical stability of the cathode–electrolyte interface (CEI) has been the primary technical emphasis to enable this category of cathode materials, which has been significantly underexplored. Herein, in this study, we focus on investigating the fundamental mechanism of parasitic reactions at the charged surface of the high-voltage MgCrMnO 4 model cathode with different organic electrolytes. The aim is to reveal the underlying effect of anions and solvents responsible for the passivation behavior of the cathode by using three exemplary anions: [(CF 3 SO 2 ) 2 N] − (TFSI − ), Al[OC(CF 3 ) 3 ] 4 − (TPFA − ), and [CB 11 H 12 ] − (MC) and three solvents: diglyme (G2), triglyme (G3), and 3-methoxypropylamine (MPA). High precision leakage current measurements during potentiostatic hold reveal that the electrolyte solvent chemistry has a more profound impact than anion's on the passivation of the MgCrMnO 4 cathode surface during deintercalation of Mg 2+ . X-ray photoelectron spectroscopy exhibits the differences in CEI composition. Amine solvents like MPA show poor passivation due to a higher degree of solvent decomposition, while the thin and anion-derived CEI in glyme-based electrolytes is directly linked with the better passivation behavior on the cathode. Furthermore, we leverage the knowledge from these findings to modify the electrolyte structure by adding a solvent additive, with the goal of reducing the parasitic reaction.

25 ENERGY STORAGE↗

Exposed high-voltage source effect on the potential of an ionospheric satellite

A pulsed, high-voltage source, which is able to draw a current from the surrounding plasma, is seen to induce large changes in the potential of an ionospheric satellite (the Iowa Plasma Diagnostics Package flown on Space Shuttle flight STS-51F). This, in turn, may affect the operation of other instruments that use the chassis of the satellite as a ground for electrical circuits. The magnitude of the change in satellite potential is dependent upon both the orientation of the high-voltage source, relative to the plasma flow, and the characteristics of the high-voltage source. When the satellite is grounded to the Shuttle Orbiter, this effect is sufficient to change the potential of the Orbiter by a small, but noticeable, amount.

Tribble, A. C.↗

High voltage design guide. Volume 5: Spacecraft

This report supplies the technical background and design techniques needed by an engineer who is designing electrical insulation for high-voltage, high-power components, equipment, and systems on spacecraft. The data in this volume is in addition to the material in Volume 4 of the final report "High Voltage Design Guide: Aircraft' which is common to the electrical insulation design for both aircraft and spacecraft equipment. The common data includes testing, tracking, partial discharges and corona. Unique material involves the semi vacuum environment, spacecraft charging, and multipactor.

W G Dunbar↗

Modeling of Electro-Magneto-Thermo-Mechanical Interactions in High Voltage Materials and Structures for Electric Propulsion

The growing interest in developing high-voltage-, high-power-capable electrical components for electric aircraft propulsion requires a more in-depth understanding of their electrical characteristics, critical material responses, and their synergistic influence on the overall performance of the system. A model that can accurately replicate the electrical, magnetic, thermal, and mechanical operating stresses and successfully predict the performance of the components will help engineers optimize the system design for a given airframe and powertrain.

electric propulsion↗

High voltage battery cell scanner development

Battery cell voltage scanners have been previously used in low voltage spacecraft applications. In connection with future missions involving an employment of high-power high voltage power subsystems and/or autonomous power subsystem management for unattended operation, it will be necessary to utilize battery cell voltage scanners to provide battery cell voltage information for early detection of impending battery cell degradation/failures. In preparation for such missions, a novel battery cell voltage scanner design has been developed. The novel design makes use of low voltage circuit modules which can be applied to high voltage batteries in a building block fashion. A description is presented of the design concept and test results of the high voltage battery cell scanner, and its operation with an autonomously managed power subsystem is discussed.

Lepisto, J. W.↗

Cleaning High-Voltage Equipment With Corncob Grit

High electrical resistance of particles makes power shutdown unnecessary. New, inexpensive method of cleaning high-voltage electrical equipment uses plentiful agricultural product - corncob grit. Method removes dirt and debris from transformers, circuit breakers, and similar equipment. Suitable for utilities, large utility customers, and electrical-maintenance services.

Caveness, C.↗

High voltage delivery and distribution for the NEXT-100 Time Projection Chamber

A critical element in the realization of large liquid andgas time projection chambers (TPCs) is the delivery and distributionof high voltages into and around the detector. Such experimentsrequire of order tens of kilovolts to enable electron drift overmeter-scale distances. This paper describes the design andoperation of the cathode feedthrough and high voltage distributionthrough the field cage of the NEXT-100 experiment, an undergroundTPC that will search for neutrinoless double beta decay0νββ. The feedthrough has been demonstrated to holdpressures up to 20 bar and sustain voltages as high as -65 kV.The TPC is operating stably at its design high voltages. The systemhas been realized within the constraints of a stringent radiopuritybudget and is now being used to execute a suite of sensitive doublebeta decay analyses.

Adams, C. [Argonne]↗

Radioimaging for real-time tracking of high-voltage breakdown

Development of a radioimaging diagnostic for high-voltage component reliability testing and electrical breakdown computational model validation is described. Radioimaging has its roots in radio astronomy, where aperture synthesis (also known as synthesis imaging) has been utilized for decades to image radio sources far from Earth. Radioimaging as described herein, in contrast, seeks to image radio sources in close proximity to its receivers (i.e., in a laboratory environment). Here it is shown that corona discharge, a non-destructive precursor to catastrophic (thermal) arc discharge, electromagnetically radiates strongly within a 250 kHz – 2.5 GHz bandwidth, and is readily detected and located by postprocessing the received radio signals. The ability of radioimaging to detect both corona and arc discharge (grouped together herein as high voltage breakdown or HVB) makes it a valuable tool for 100% HVB detection in materials, components, and devices, and has the ability to indicate electrical weakness (via corona detection) prior to a destructive arc discharge event. Radioimaging enables HVB to be located both internal and external to dielectric components under test in near-real-time, with multiple and/or extended HVB events located simultaneously. In contrast, existing non-destructive diagnostics (at the time of this writing) either indicate electrical breakdown without resolving failure locations (e.g., current, voltage, and chemical measurements), locate external HVB (e.g., high-speed optical and ultraviolet (UV) measurements or photography), or locate both external and internal HVB but with low fidelity (e.g., a single HVB source can be located by existing time-of-arrival (TOA) UHF or acoustic emissions). Radioimaging instead creates a sequence of high-fidelity images similar to an optical high-speed camera but at radiofrequencies (RF), and is not limited to two-dimensions. Moreover, radioimaging has already served one internal and two external industry customers, the results of which are detailed in this report. The radioimaging results described herein were part of a three-year effort funded by the Sandia Lab Directed Research and Development (LDRD) program within the Radiation, Electromagnetic, High Energy Density Science (REHEDS) investment area.

47 OTHER INSTRUMENTATION↗

Scattering Efficiency of High-Voltage Tethers in Space

Several concepts have been proposed to remediate the effect of artificial Radiation Belts (RB) in Space Plasma. Among them is the high-voltage electrostatic tether remediation technique. Preliminary analysis that has been carried out later by several groups showed, that this technique could be very efficient and is able to control relativistic electron energies of artificial RB population. The relativistic electron population is the one of the most important topic of US Space Weather studies and very dangerous to many civilian and military space assets, it is also important to study some fundamentals of scattering efficiency of high-voltage tethers in space plasma. There are several fundamental issues that should be examined in order to validate high-voltage tether artificial RB remediation concept. The most critical among them are: power consumption, the size and stability of the plasma sheath around the tether, and scattering efficiency of this high-voltage system that is ultimately related with the plasma sheath size. This study would be focused on the scattering process itself and artificial RB remediation assuming that power consumption and the size of the plasma sheath are known.

Krivorutsky, E. N.↗

Progresses in Developing Micro-Multilayer Multifunctional Electrical Insulation (MMEI) System for High Voltage Applications

Development of the novel patented high voltage insulation system, namely micro-multilayer multifunctional electrical insulation (MMEI) was continued particularly for the future hybrid or all electric aircraft applications. Initially, the concept and feasibility of the MMEI system were successfully demonstrated with its exceptionally high dielectric breakdown voltage via optimizing the multilayer structures of the Kapton® PI films and binder layers such as PFA in terms of individual film thickness and layer configuration. Overall, MMEI structures outperformed most of the state-of-the-art (SOA) polymer insulation materials or structures. Since then, further optimizations and improvement of the system were pursued with specific emphasis on multifunctionalities such as moisture blocking, partial discharge (PD) resistance, durability, etc. Efforts have been also continued to identify the controlling mechanisms for the major improvement in dielectric strength of the MMEI structures via 3-dimensional dielectric failure mode analysis. At the same time, significant progress has been made in scaling up the MMEI structures and assessing their commercial applicability and manufacturability by developing full-scale prototypes of electrical components, such as power cable and bus bar. Overall progresses on the MMEI development to date will be presented in this paper.

Novel Electrical Insulation↗