PIC simulation of electrodeless plasma thruster with rotating electric field

For longer lifetime of electric propulsion system, an electrodeless plasma thruster with rotating electric field have been proposed utilizing a helicon plasma source. The rotating electric field may produce so-called Lissajous acceleration of helicon plasma in the presence of diverging magnetic field through a complicated mechanism originating from many parameters. Two-dimensional simulations of the Lissajous acceleration were conducted by a code based on Particle-In-Cell (PIC) method and Monte Carlo Collision (MCC) method for understanding plasma motion in acceleration area and for finding the optimal condition. Obtained results show that azimuthal current depends on ratio of electron drift radius to plasma region length, AC frequency, and axial magnetic field. When ratio of cyclotron frequency to the AC frequency is higher than unity, reduction of the azimuthal current by collision effect is little or nothing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helicon-Injected Inertial Electrostatic Confinement Neutron Source or Space Propulsion Device

Work is ongoing at the University of Illinois on a Helicon Injected Inertial Plasma Electrostatic (IEC) as a neutron source for neutron activation analysis. It is also of interest for use as an Helicon Injected IEC Rocket, or HIIPER. In both cases the use of the external plasma source allows a lower pressure in the IEC chamber, reducing inefficiency due to ion charge exchange losses. As a neutron source, the IEC grids serve to recirculate the deuterium ions such that fusion collisions can occur. For HIIPER asymmetry in the IEC grids forms a jet-like exhaust of accelerated plasma, producing a force. In both cases the IEC grid is designed to extract ions from the external radio frequency (RF) plasma generating stage run in the helicon mode. Because electrons have been measured in glow discharge mode for this grid design, the HIIPER exhaust plasma is potentially a neutralized plasma flow. This is a benefit over ion and Hall thrusters, which require electron generating cathodes to neutralize the accelerated ion exhaust. An additional benefit of this setup is that separating the plasma generating and plasma-accelerating stages is beneficial for space mission planning.

07 ISOTOPE AND RADIATION SOURCES↗

Measurements and modeling of radio frequency field structures in a helicon plasma

Measurements of the radio frequency (rf) field structure, plasma density, and electron temperature are presented for a 1 kW argon helicon plasma source. The measured profiles change considerably when the equilibrium magnetic field is reversed. The measured rf fields are identified as fields of radially localized helicon waves, which propagate in the axial direction. The rf field structure is compared to the results of two-dimensional cold plasma full-wave simulations for the measured density profiles. Electron collision frequency is adjusted in the simulations to match the simulated and measured field profiles. The resulting frequency is anomalously high, which is attributed to the excitation of an ion-acoustic instability. The calculated power deposition is insensitive to the collision frequency and accounts for most of the power supplied by the rf-generator.

74 ATOMIC AND MOLECULAR PHYSICS↗

Understanding carbon sourcing and transport originating from the helicon antenna surfaces during high-power helicon discharge in DIII-D Tokamak

The high-power helicon wave system in the DIII-D tokamak could potentially introduce new plasma–material interaction (PMI) challenges owing to rectified RF sheath potentials that develop near the antenna and surrounding plasma-facing components. We present the first application of the STRIPE (Simulated Transport of RF Impurity Production and Emission) framework to helicon-induced PMIs, extending previous STRIPE studies of ICRH antennas by incorporating net erosion, local re-deposition, and three-dimensional global impurity transport. The integrated workflow couples SOLPS, COMSOL, RustBCA, GITR, and GITRm to simulate carbon erosion, re-deposition, and impurity transport for two experimentally constrained DIII-D H-mode helicon operating scenarios with different antenna–plasma gaps, coupled RF powers, and edge plasma conditions. COMSOL predicts rectified RF sheath potentials of 1–5 kV localized near the lower portion of the antenna, where the magnetic field intersects the surface at grazing incidence. Carbon self-sputtering dominates the erosion source, whereas RF-accelerated D + ions contribute approximately 1% of the total gross erosion. The smaller-gap operating scenario exhibits substantially stronger gross erosion, enhanced local re-deposition (∼12%), and a larger confined carbon inventory owing to increased plasma accessibility and broader RF sheath coverage. Comparison with available DIII-D measurements shows no distinct change in the global carbon signal that correlates with the helicon RF pulse, consistent with the simulations indicating that the helicon-generated carbon source remains small compared with the existing background carbon inventory under the present graphite-wall operating conditions. These results demonstrate the capability of STRIPE to integrate RF sheath modeling, plasma transport, surface interaction physics, and three-dimensional impurity transport for the interpretation of helicon-induced PMIs. The study further identifies the principal sources of modeling uncertainty, including grazing-angle RF sheath physics, slow-wave resolution, plasma-background extrapolation, and trace-impurity transport assumptions, providing a framework for future validation and model development.

Kumar, Atul [Oak Ridge National Laboratory (ORNL),↗

Recent Progress on the VASIMR

Experimental and theoretical studies on the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) have continued through a NASA led collaborative program involving several research groups. In the experimental area, performance characterization of the VASIMR helicon plasma source has been obtained over a portion of the parameter space, with helium and hydrogen propellant. Density (10(exp 18) - 10(exp 19)/ cubic meter) and temperature (5 eV) were measured at moderate degree of ionization in two separate experimental devices. Helicon design improvement and optimization will be discussed. Experiments with the ion cyclotron resonance heating (ICRH) subsection have begun and preliminary results will be discussed. Theoretical picture and integrated numerical simulation continue to be refined to account for the main physics elements of the VASIMR, including RF absorption and particle acceleration with subsequent detachment in the magnetic nozzle.

ChangDiaz, Franklin R.↗

MPEX AI Digital Twins

All magnetically confined plasma fusion power plant concepts (Tokamak, Spherical Tokamak, Stellarator, Mirror, ...) must exhaust the heat and plasma from the core confinement region to the material walls. The primary channel for this exhaust is through a plasma divertor which directs plasma along open magnetic field lines to a material target. The Material Plasma Exposure eXperiment (MPEX) illustrated in Figure 1, is a high-power, steady-state linear plasma device designed to produce the plasma material interaction (PMI) conditions of the divertor of future magnetic confinement fusion power plants: energy flux 20MW/m 2 , ion fluence 1031/m 2 , pulse duration 106 sec. These goals of plasma exposure in MPEX are well beyond those achieved in magnetic fusion experimental devices. Successfully achieving these high power steady state conditions for long pulses requires operational control of the heating and particle sources and the plasma flux to the walls and target. The MPEX AI Hot Spot Controller, proposed in this project, will help achieve the operational milestones of MPEX. The MPEX device will begin commissioning at the end of FY26. A smaller proto-MPEX was operated for 14,666 plasma discharges and will resume operation in September of 2025 as proto-MPEX-lite, with reduced capability, to test a new window for the Helicon plasma source. The proto-MPEX data has undergone surrogate modeling with machine learning methods (R. Archibald, 2022 IEEE International Conference on Big Data). This proto-MPEX data will be used to begin development of the AI digital twins described in this white paper. The scientific mission of MPEX is to qualify materials of different composition for use in the high energy and plasma flux conditions of a fusion power plant. The materials exposed in MPEX will in some cases be exposed to high neutron fluxes at other ORNL facilities to measure the changes to their PMI properties. The targets exposed in MPEX will be transported under vacuum to a Surface Analysis Station (SAS). The SAS will be equipped with the following diagnostics: Focused Ion Beam (FIB) for trench milling, 100-400 angstrom resolution scanning electron microscope (SEM), surface mapping x-ray spectrometer, high resolution camera, and a future upgrade to a laser induced breakdown spectroscopy quadruple mass spectrometer (LIBS-QMS). The MPEX experiments will generate diverse pre- and post-exposure measurement data of detailed material properties down to the crystal grain level in 3D for post-exposure assessment of PMI damage (e.g. cracking, melting, erosion and redeposition of the material). Physics models for the PMI, and how the material composition and manufacturing impact its performance under high energy plasma exposure, need to be validated with MPEX data to guide the selection of new candidate materials. Our vision for the MPEX AI Digital Twins project is to supply experimental and physics model simulation data to train Artificial Intelligence (AI) models for data processing, analysis, operational control, PMI and materials simulation to maximize the scientific output of the MPEX device. Ultimately, an AI digital twin of MPEX material assessment metrics for tested and synthetic material types with simulated PMI will be trained by the AI Modeling Teams on the experimental and physics simulation data submitted to the American Science Cloud by this project. A purely empirical search for the best material is inefficient given the finite number of samples that can be tested on MPEX. In order to expand the material properties database for training the MPEX Material Assessment AI Digital Twin, and to gain physics understanding of the PMI processes, physics models of the material properties and PMI processes are required. The physics simulations provide detailed simulation data, like impact angles for plasma ions, sputtering yields, transport of the ionized sputtered target material in the plasma, and redeposition locations. This simulation data expands the measurement data for deeper physics understanding. The experimental data is essential to validate the PMI and material structure simulation models. The validated models can then be used to generate new simulation data of MPEX material assessments for synthetic material compositions that have not been exposed in MPEX. These predictive simulations, plus the whole experimental dataset, will be used to train the MPEX Material Assessment AI Digital Twin allowing a rapid generative AI search for new materials with reduced PMI damage by interpolating the domain of the training set. These new optimum materials can be simulated with the physics codes and/or tested in MPEX. The ability of AI neural networks to interpolate multi-dimensional parameter spaces and generate virtual data is exploited for a more efficient search for optimum materials. The advent of the Transformational AI Models Consortium (TAIMC) is an opportunity to engage with state of the art private and public AI developers to achieve the goals of the AI digital twins and AI accelerated physics models proposed in this project. Our partners at ORNL from the Advance Scientific Computing Research (ASCR) organization will collaborate in accelerating the integrated plasma material interaction simulation framework. This simulation framework will provide a platform for generating simulation data across a range of physical fidelities, including hybrid methods that produce multi-fidelity results. This data will be leveraged for AI model development, both for generation of surrogates and the automation of simulation campaigns. A part of the research below will include collaborative efforts with the TAIMC to (i) adapt data storage approaches to ensure AI-readiness, (ii) provide a protypical exemplar to inform and exercise constructed workflows, and (iii) generate and share data, using the TAIMC unified AI data standard, for foundational models that will be trained from multiple sources across the DOE complex. We will also collaborate with the TAIMC, as well as the planned AI modeling teams, to develop approaches for reducing the cost of data generation. These include tailored multi-fidelity approaches as well as fine-tuning strategies to augment general, large-scale foundational models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface Plasma Source Electrode Activation by Surface Impurities

In experiments with RF saddle antenna surface plasma sources (SPS), the efficiency of H- ion generation was increased by up to a factor of 5 by long time plasma electrode activation, without adding Cs from Cs supply, by heating the collar to high temperature using hot air flow and plasma discharge. Without cracking or heating the cesium ampoule, but likely with Cs recovery from impurities, the achieved energy efficiency was comparable to that of conventionally cesiated SNS RF sources with an external or internal Cs supply. In the experiments, perfect cesiation was produced (without additional Cs supply) by the collection and trapping of traces of remnant cesium compounds from SPS surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A DOE/Fusion Energy Sciences Research/Education Program at PVAMU Study of Rotamak Plasmas

During recent years (2004-2015), with DOE support, the PVAMU plasma research group accomplished new instrumentation development, conducted several new plasma experiments, and is currently poised to advance with standing-wave microwave plasma propulsion research. On the instrumentation development, the research group completed: (i) building a new plasma chamber with metal CF flanges, (ii) setting up of a 6kW/2450MHz microwave input system as an additional plasma heating source at our rotamak plasma facility, (iii) installation of one programmatic Kepco ATE 6-100DMG fast DC current supply system used in rotamak plasma shape control experiment, built a new microwave, standing-wave experiment chamber and (iv) established a new plasma lab with field reversal configuration capability utilizing 1MHz/200kW RF (radio frequency) wave generator. Some of the new experiments conducted in this period also include: (i) assessment of improved magnetic reconnection at field-reversed configuration (FRC) plasma, (ii) introduction of microwave heating experiments, and (iii) suppression of n = 1 tilt instability by one coil with a smaller current added inside the rotamak’s central pipe. These experiments led to publications in Physical Review Letters, Reviews of Scientific Instruments, Division of Plasma Physics (DPP) of American Physical Society (APS) Reports, Physics of Plasmas Controlled Fusion, and Physics of Plasmas (between 2004 and 2015). With these new improvements and advancements, we also initiated and accomplished design and fabrication of a plasma propulsion system. Currently, we are assembling a plasma propulsion experimental system that includes a 5kW helicon plasma source, a 25 cm diameter plasma heating chamber with 1MHz/200kW RF power rotating magnetic field, and a 60 cm diameter plasma exhaust chamber, and expect to achieve a plasma mass flow of 0.1g/s with 60km/s ejection. We anticipate several propulsion applications in near future as we advance our capabilities. Apart from scientific staff members, several students (more than ten undergraduate students and two graduate students from several engineering and science disciplines) were supported and worked on the equipment and experiments during the award period. We also anticipate that these opportunities with current expansions may result in a graduate program in plasma science and propulsion engineering disciplines. *Corresponding Author – Dr. Saganti, Regents Professor and Professor of Physics – pbsaganti@pvamu.edu

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pre-conceptual design activities for the materials plasma exposure experiment

The development of next step fusion facilities such as DEMO or a Fusion Nuclear Science Facility (FNSF) requires first closing technology gaps in a few critical areas. Understanding the material-plasma interface is necessary to enable the development of divertors for long-pulse plasma facilities. A pre-conceptual design for a proposed steady-state linear plasma device, the Materials Plasma Exposure Experiment (MPEX), is underway. A helicon plasma source along with ion cyclotron and electron Bernstein wave heating systems will produce ITER divertor relevant plasma conditions with steady-state parallel heat fluxes of up to 40 MW/m 2 with ion fluxes up to 10 24 /m 2 s on target. Current plans are for the device to use superconducting magnets to produce 1–2 T fields. As a steady-state device, active cooling will be required for components that interact with the plasma (targets, limiters, etc.), as well as for other plasma facing components (transport regions, vacuum tanks, diagnostic ports). Design concepts for the vacuum system, the cooling system, and the plasma heating systems have been completed. The device will include the capability for handling samples that have been neutron irradiated in order to consider the multivariate effects of neutrons, plasma, and high heat-flux on the microstructure of divertor candidate materials. A vacuum cask, which can be disconnected from the high field environment in order to perform in-vacuo diagnosis of the surface evolution is also planned for the facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-beta plasma effects in a low-pressure helicon plasma

In this work, high-beta plasma effects are investigated in a low-pressure helicon plasma source attached to a large volume diffusion chamber. When operating above an input power of 900 W and a magnetic field of 30 G a narrow column of bright blue light (due to Ar II radiation) is observed along the axis of the diffusion chamber. With this blue mode, the plasma density is axially very uniform in the diffusion chamber; however, the radial profiles are not, suggesting that a large diamagnetic current might be induced. The diamagnetic behavior of the plasma has been investigated by measuring the temporal evolution of the magnetic field (B{sub z}) and the plasma kinetic pressure when operating in a pulsed discharge mode. It is found that although the electron pressure can exceed the magnetic field pressure by a factor of 2, a complete expulsion of the magnetic field from the plasma interior is not observed. In fact, under our operating conditions with magnetized ions, the maximum diamagnetism observed is {approx}2%. It is observed that the magnetic field displays the strongest change at the plasma centre, which corresponds to the maximum in the plasma kinetic pressure. These results suggest that the magnetic field diffuses into the plasma sufficiently quickly that on a long time scale only a slight perturbation of the magnetic field is ever observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion beam acceleration in a divergent magnetic field

Two-dimensional argon ion velocity distribution functions (IVDFs) in the expansion region of a helicon plasma source have been measured by laser-induced-fluorescence tomography. Below a threshold value of the magnetic field in the expansion region, the IVDFs show a bimodal structure comprised of a supersonic ion population axially moving away from the source and an isotropic, slow, background, ion population. Increasing the magnetic field divergence leads to an increase in the axial speed of the supersonic component. A maximum axial speed of {approx}2.9c{sub s} was obtained for a source/expansion magnetic field ratio of 43.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic steering of a helicon double layer thruster

The ion beam generated by a helicon double layer has been electrically steered up to 20 deg. off axis by using a solenoid placed normal to the two axial solenoids of the helicon plasma source without significantly changing the beam exhaust velocity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of neutral helium density in helicon plasmas

Laser-induced-fluorescence (LIF) is used to measure the density of helium atoms in a helicon plasma source. For a pump wavelength of 587.725 nm (vacuum) and laser injection along the magnetic field, the LIF signal exhibits a signal decrease at the Doppler shifted central wavelength. The drop in signal results from the finite optical depth of the plasma and the magnitude of the decrease is proportional to the density of excited state neutral atoms. Using Langmuir probe measurements of plasma density and electron temperature and a collisional-radiative model, the absolute ground state neutral density is calculated from the optical depth measurements. Optimal plasma performance, i.e., the largest neutral depletion on the axis of the system, is observed for antenna frequencies of 13.0 and 13.5 MHz and magnetic field strengths of 550-600 G.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two photon absorption laser induced fluorescence measurements of neutral density in a helicon plasma

We have developed a new diagnostic based on two-photon absorption laser induced fluorescence (TALIF). We use a high intensity (5 MW/cm{sup 2}), narrow bandwidth (0.1 cm{sup −1}) laser to probe the ground state of neutral hydrogen, deuterium and krypton with spatial resolution better than 0.2 cm, a time resolution of 10 ns, and a measurement cadence of 20 Hz. Here, we describe proof-of-principle measurements in a helicon plasma source that demonstrate the TALIF diagnostic is capable of measuring neutral densities spanning four orders of magnitude; comparable to the edge neutral gradients predicted in the DIII-D tokamak pedestal. The measurements are performed in hydrogen and deuterium plasmas and absolute calibration is accomplished through TALIF measurements in neutral krypton. The optical configuration employed is confocal, i.e., both light injection and collection are accomplished with a single lens through a single optical port in the vacuum vessel. The wavelength resolution of the diagnostic is sufficient to separate hydrogen and deuterium spectra and we present measurements from mixed hydrogen and deuterium plasmas that demonstrate isotopic abundance measurements are feasible. Time resolved measurements also allow us to explore the evolution of the neutral hydrogen density and temperature and effects of wall recycling. We find that the atomic neutral density grows rapidly at the initiation of the discharge, reaching the steady-state value within 1 ms. Additionally, we find that neutral hydrogen atoms are born with 0.08 eV temperatures, not 2 eV as is typically assumed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct measurements of ion dynamics in collisional magnetic presheaths

Ion velocities and temperatures are measured in the presheath of a grounded plate downstream from an argon helicon plasma source using laser-induced fluorescence (P{sub rf}≈450→750 W, T{sub e}=2.5→5 eV, T{sub i}=0.1→0.6 eV, n{sub 0}≈1×10{sup 12}cm{sup −3}, p{sub n}=1→6.5 mTorr, λ=0.3→2 cm, ρ{sub i}≈ 0.5 cm). The plate is held 16°→60° relative to the 1 kG background axial magnetic field. The velocity profiles are compared to a 1D fluid model similar to those presented by Riemann [Phys. Plasmas 1, 552 (1994)] and Ahedo [Phys. Plasmas 4, 4419 (1997)] for the 1 mTorr dataset and are shown to agree well. The model is sensitive to parameters such as collision and ionization frequencies and simplified models, such one presented by Chodura [Phys. Fluids 25, 1628 (1982)], are shown to be inaccurate. E{sup →}×B{sup →} flows as large as 40% of c{sub s} at the sheath edge are inferred. Definitions for the term “magnetic presheath” and implications for ion flow to tokamak divertors and Hall thruster walls are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical validation of axial plasma momentum lost to a lateral wall induced by neutral depletion

Momentum imparted to a lateral wall of a compact inductively coupled plasma thruster is numerically investigated for argon and xenon gases by a particle-in-cell simulation with Monte Carlo collisions (PIC-MCC). Axial plasma momentum lost to a lateral wall is clearly shown when axial depletion of the neutrals is enhanced, which is in qualitative agreement with the result in a recent experiment using a helicon plasma source [Takahashi et al., Phys. Rev. Lett. 114, 195001 (2015)]. The PIC-MCC calculations demonstrate that the neutral depletion causes an axially asymmetric profile of the plasma density and potential, leading to axial ion acceleration and the non-negligible net axial force exerted to the lateral wall in the opposite direction of the thrust.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a spectroscopic diagnostic tool for electric field measurements in IShTAR (Ion cyclotron Sheath Test ARrangement)

IShTAR, Ion cyclotron Sheath Test ARrangement, is a linear device dedicated to the investigation of the edge plasma–ICRF (Ion Cyclotron Range of Frequencies) antenna interactions in tokamak edge-like conditions and serves as a platform for a diagnostic development for measuring the electric fields in the vicinity of ICRF antennas. We present here our progress in the development of an optical emission spectroscopy method for measuring the electric fields which concentrates on the changes in the helium spectral line profiles introduced by the external electrical field, i.e., the Stark effect. To be able to fully control the operating parameters, at the first stage of the study, the measurements are conducted on a planar electrode installed in the centre of the plasma column in IShTAR’s helicon plasma source. At the second stage, the measurements are performed in the vicinity of IShTAR’s ICRF antenna.

Kostic, Ana↗

Continuous-wave planar laser induced fluorescence with a fast camera

We present planar, laser induced fluorescence (PLIF) measurements of the velocity-resolved distribution function of ions in a plasma using a modulated, narrow linewidth, continuous-wave laser. Plasma emission is acquired with a high frame rate camera, and the laser light is spread into a thin sheet so that an entire plane of the plasma is imaged at each interrogation wavelength. Fourier analysis is conducted on each pixel of the images to separate the modulated fluorescent emission from the background light. Argon ion temperatures and bulk flow maps are reported in a helicon plasma source, and standard single-point LIF measurements provide validation of the PLIF measurement.

47 OTHER INSTRUMENTATION↗