Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Field Test and Thermal Performance Comparison of a Novel Underground Thermal Battery with a Single U-tube Borehole Heat Exchanger for Geothermal Heat Pump Application

Geothermal Heat Pumps (GHP) are a proven technology to electrify and decarbonize space heating and cooling by utilizing the thermally consistent underground as a heat sink or source. However, the high drilling costs of conventional borehole heat exchangers (BHEs) associated with GHP systems and subsurface heterogeneity have been two major challenges to their widespread adoption. In this paper, we present results from a field-scale pilot of an Underground Thermal Battery (UTB) as a potential alternative to a conventional BHE. To benchmark the UTB performance, a side-by-side field test was conducted to compare the UTB with a conventional BHE installed at the same site. The UTB was installed in a 7.01-meter-deep borehole having a diameter of 0.9 meter, whereas the conventional BHE (with single U-tube loop) is in a borehole with 36.6-meter depth and 0.15-meter diameter. Both are integrated into a GHP system to meet the thermal energy demands of office space at the Illinois Energy Farm on the University of Illinois Urbana-Champaign campus. The system’s performance is compared in terms of heat transfer rate, outlet temperatures, and contributions to the overall thermal power of the GHP system under varying thermal demands and in different heat pump operation modes: heating only, cooling only, and hybrid (alternative, diurnal heating and cooling). Results to date indicate that the UTB delivers a more consistent response under during a time period of varying thermal demands. Its operational performance is better during short-term with higher thermal demands, while the conventional BHE performs better under continuous, long-term thermal demands.

Pokhrel, Sajjan [ORNL] (ORCID:0000000228523749)↗

Performance Assessment of a Heat Pump Integrated with Thermal Energy Storage in Cooling & Heating Modes

Thermal Energy Storage (TES) systems have demonstrated significant potential to manage the fluctuating nature of energy demand and shifting peak loads. This technology has made significant recent advances, including new research on the integration of TES with residential and commercial Heating, Ventilation, and Air-Conditioning (HVAC) systems. In this paper, we present the use of a novel laboratory assessment framework for a prototype heat pump system integrated with latent heat phase change material-based TES. The assessment framework consists of 22 total test points (11 heating, 11 cooling) using psychrometric conditions from AHRI Standard 210/240 and includes transient conditions to evaluate TES charging and discharging modes. In addition, both continuous mode and cyclic mode were evaluated for charging and discharging to explore the benefits to TES heat transfer from repeated transient operation. The ambient conditions evaluated include heating mode charging at cold-climate heat pump conditions when winter-peaking utilities may most require demand reduction (H4Full conditions, 5°F/-15°C) and cooling mode charging at high ambient temperature that may occur during times of day when excess solar power generation results in low-cost electricity (105°F/40.6°C). The work demonstrates the demand reduction capabilities of integrating TES with HVAC, including up to 44% in cooling mode and 60% in heating mode compared to conventional HVAC equipment without TES.

25 ENERGY STORAGE↗

A novel 3-D pulsating heat pipe module for high heat-flux applications

This study proposed a novel pulsating heat pipes (PHP) for high-flux thermal module. According to the open literature, the maximum value of the heat flux is 23.7 W∙cm –2 handled by PHP, which is far behind industry requirements. Therefore, the present study proposes a novel 3D PHP suitable for high heat-flux applications. The PHP were experimentally tested for different working fluids, including methanol and water. Furthermore, the experiments were performed to analyze the influence of various operating parameters, such as filling ratio (25–60%), heat load (100–800 W), and air flow rate 100–250 cubic feet per minute (CFM). In this work, the results showed that this PHP can sustain a heat flux up to 70 W∙cm –2 with the maximum case temperature under 80 °C, which is approximately three times higher than the available literature. Furthermore, the performance of the PHP module was compared against the commercial module with wicked heat pipe. The PHP exhibited about 7% higher heat dissipation compared to the commercial module. Since the proposed module uses simple copper tubes in its construction over the wicked structure used in commercial module, the novel 3D PHP module provides additional economic and mass production capability.

3D pulsating heat pipe↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Effect of Urban Heat Island and Global Warming Countermeasures on Heat Release and Carbon Dioxide Emissions from a Detached House

Urban air temperature rises induced by the urban heat island (UHIE) effect or by global warming (GW) can be beneficial in winter but detrimental in summer. The SCIENCE-Outdoor model was used to simulate changes to sensible heat release and CO 2 emissions from buildings yielded by four UHIE countermeasures and five GW countermeasures. This model can evaluate the thermal condition of building envelope surfaces, both inside and outside. The results showed that water-consuming UHIE countermeasures such as evaporative space cooling and roof water showering provided positive effects (decreasing sensible heat release and CO 2 emissions related to space conditioning) in summer. Additionally, they had no negative (unwanted cooling) effects in winter since they can be turned off in the heating season. Roof greening can provide the greatest space- conditioning CO 2 emissions reductions among four UHIE countermeasures, and it reduces the amount of heat release slightly in the heating season. Since the effect on reducing carbon dioxide (CO 2 ) emissions by UHIE countermeasures is not very significant, it is desirable to introduce GW countermeasures in order to reduce CO 2 emissions. The significance of this study is that it constructed the new simulation model SCIENCE-Outdoor and applied it to show the influence of countermeasures upon both heat release and CO 2 emissions.

54 ENVIRONMENTAL SCIENCES↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced absorber heat integration via heat exchange packings

A rate-based model of an absorption column was developed and used to analyze several intercooling strategies utilizing “heat exchange packings.” These packings are capable of removing heat from the column and transferring it to a cooling fluid within the packing. For absorption of CO 2 into aqueous monoethanolamine under industrial conditions, intercooling via heat exchange packings placed along 10–20% of the column could reduce the column height by ~15%. The height of these columns was close to the minimum theoretical value, calculated by numerically optimizing the temperature profile. Effective intercooling could also be achieved by using the cool, rich solvent as the cooling fluid. This reduces the cooling load and facilitates recovery of waste heat. Heat exchange packings could also be used to redistribute heat within the column, reducing the column height with no net cooling load. However, this approach requires larger heat transfer coefficients than have been experimentally observed.

20 FOSSIL-FUELED POWER PLANTS↗

Studies of the influence of heat pipe model and coupling strategy in heat pipe microreactor simulations using Sockeye

This work demonstrates various modeling approaches for thermally coupling heat pipes to a graphite monolithic block in a microreactor context, accounting for the presence of a gap. We show that heat pipe model selection has a significant impact on the transient behavior of a three-dimensional coupled microreactor assembly problem by comparing results obtained using different heat pipe models from the heat pipe code Sockeye. Additionally, we show that the choice of coupling strategy has significant consequences for both accuracy and performance. Furthermore, we found that our heat flux transfer strategy exhibited greater accuracy than our temperature transfer strategy, even when comparing a loose coupling of the heat flux transfer strategy to a tight coupling of the temperature transfer strategy. Although this research uses only theoretical test problems, it provides important insights in modeling thermal fluids phenomena in heat pipe microreactors.

Direwolf↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗

Heat pulse propagation and anomalous electron heat transport measurements on the optimized stellarator W7-X

The optimized stellarator Wendelstein 7-X (W7-X) is designed to have an approximately quasi-isodynamic magnetic configuration with reduced neoclassical transport in comparison to a classical stellarator, and turbulent transport is expected to be a significant source of anomalous heat transport across the plasma minor radius. The ion temperature gradient driven mode and the trapped electron mode (TEM) are thought to be responsible for the ion-scale turbulence in W7-X plasmas with volume averaged pressure below 1%. In this work, the electron temperature gradient driven turbulence is shown to be a good candidate for the explanation of the observed electron heat flux, in the inner plasma region where the density gradient is weak (in the outer region, a relatively stronger density gradient would drive additional TEM turbulence). Further, the experimental electron heat transport measured during electron cyclotron resonant heating power and plasma density scans is compared to neoclassical predictions, and the stiffness in the electron heat transport measured during transient transport experiments is presented in three common magnetic configurations of W7-X. In low-(β) plasma discharges, the stiffness in the electron heat flux, quantified by the ratio of the heat pulse to power balance diffusivity, ${\chi }_{\mathrm{e}}^{\mathrm{H}\mathrm{P}}/{\chi }_{\mathrm{e}}^{\mathrm{P}\mathrm{B}}$, is measured to be less than 2, and trend downwards with increasing collisionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design Considerations for Phase Change Material-Incorporated Heat Exchangers in Water Heating

In recent years, the buildings sector has seen major pushes towards decarbonization through innovations that promote deep electrification. 20% of an average household's energy use comes from water heating, and in the US, over half of all households still use gas water heaters. Of those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. However, HPWHs tend to have larger dimensions, preventing current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). This study outlines the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. To ensure optimal PCM utilization and tank storage capacity, this works seeks to co-maximize surface area and PCM volume; therefore, this research targets triply periodic minimal surface (TPMS) lattices, which boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives. Our current results indicate that tuning lattice properties can effectively produce geometries that provide enough energy storage to achieve a 50-gallon capacity out of a 40-gallon HPWH, even when placing the PCM heat exchanger inside the tank. Additionally, we demonstrate successful fabrication of lattices with these tuned properties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load Shifting with Space Conditioning Heat Pumps During Heating Season in the Pacific Northwest

Ductless mini- and multi-split heat pumps are commonly deployed in Pacific Northwest residences, which historically have inefficient space heating and no space cooling. Heat pumps provide these residences with more energy-efficient space heating in the winter and space cooling for increasingly warm summer periods. For many of these applications, heat pumps add a new electrical load at the residence, compelling regional utilities to seek to understand their impacts on the electrical grid and opportunities for load management. In coordination with regional utilities, this study examined the winter load-shifting potential of residential multi-split heat pumps with variable capacity technology. The study included nine residential sites with a total of 20 ductless indoor units, which underwent simulated smart grid control. Grid control functionality was provided through the CTA-2045 communication protocol and included offsetting temperature setpoints for individual indoor units in the study. Field data collection included whole-house and heating, ventilation, and air conditioning electrical power consumption; indoor zone temperatures; occupant surveys; and CTA-2045 curtailment data for both baseline and simulated load-shifting events by site. This paper provides an overview of the load-shifting strategies and aggregated results from winter data collection.

ASHRAE, Heat pump, energy effciency, residential b↗

Computational fluid dynamics investigations of flow, heat transfer, and oxidation in heat recovery steam generator

Modern heat recovery steam generators (HRSGs) operate at elevated temperatures, leading to the formation of oxides inside the tubes of heat exchangers (HXs). This oxide growth reduces the heat recovery efficiency. Moreover, after reaching a certain critical thickness, some oxide scales detach from the tube surface (exfoliation), causing erosion damage to the components downstream. Predicting the metal temperature distribution and associated oxide thickness in the HXs of an HRSG can aid in mitigating these problems. Here, a computational fluid dynamics (CFD) model was developed within the commercial code STAR-CCM+ for the prediction of fluid flow, conjugate heat transfer, and associated oxidation in HRSGs. Moreover, a new Porous Media Model (PMM) method was developed to model the fin effect on the heat transfer in HX, which can substantially reduce the prohibitive computational costs of fin meshes. The developed CFD model was used to conduct a high-fidelity simulation of a real-scale HRSG to investigate flow, heat transfer, and oxide growth. The calculated oxide thickness on different tubes can be used to identify HX regions that require oxide-resistant coatings to prevent exfoliation and ensuing damages. Furthermore, this CFD framework can serve as a reference for future studies that intend to model and investigate high-temperature oxidation in HXs used for any applications.

42 ENGINEERING↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

Understanding the heat generation mechanisms and the interplay between joule heat and entropy effects as a function of state of charge in lithium-ion batteries

The thermal performance of lithium-ion battery cells is critical for ensuring their safe and reliable operation across various applications. In this study, we employed an isothermal calorimetry method to investigate the heat generation of commercial 18650 lithium-ion battery fresh cells during charge and discharge at different current rates, ranging from 0.05C to 0.5C, and across various temperatures: 20 °C, 30 °C, 40 °C, and 50 °C. Our findings revealed a direct correlation between heat generation and current rates, indicating that higher current rates lead to increased heat generation within the cells. Conversely, we observed that heat generation remained relatively stable as the temperature rose, suggesting that temperature changes within this range may not significantly impact the heat generation of fresh cells during typical operations. Furthermore, our study explored irreversible heat generation, which depends on the applied current and overpotential, using the galvanostatic intermittent titration technique at 0.05C–0.5C and 30 °C. Additionally, electrochemical impedance spectroscopy was performed on the same cells during charge and discharge at 20 °C, 30 °C, and 40 °C to analyze cell impedance. Finally, our results indicated a consistent dependence of impedance on the state of charge and depth of discharge, with a significant increase in impedance observed at the end of the discharge process.

25 ENERGY STORAGE↗

Contribution of the Two Types of Ekman Pumping Induced Eddy Heat Flux to the Total Vertical Eddy Heat Flux

Based on eddy-rich (0.1° horizontal resolution for ocean) Community Earth System Model simulations, we compute the Ekman pumping induced vertical eddy heat flux using two formulations: the classical and the Stern-Ekman pumping. The two mechanisms yield similar patterns in the eddy-induced vertical heat flux, showing strong upward heat flux in ocean frontal regions such as the western boundary current regions. Using the Gulf Stream Extension region as an example, we estimate (1) the Stern-Ekman pumping induced eddy heat flux is 23% and 12% of the total vertical eddy heat flux at 50 m depth during summer and winter, respectively; (2) the classical Ekman pumping accounts for 82% and 88% of the Stern-Ekman pumping induced eddy heat flux at 50 m during summer and winter, respectively. The second finding indicates eddy current feedback on wind stress is the primary cause for the upward eddy heat flux generated by Ekman pumping.

58 GEOSCIENCES↗

The global dynamic of DNA methylation in response to heat stress revealed epigenetic mechanism of heat acclimation in Saccharina japonica

Saccharina japonica is an ecologically and economically important kelp in cold‐temperate regions. When it is cultivated on a large scale in the temperate and even subtropical zones, heat stress is a frequent abiotic stress. This study is the first attempt to reveal the regulatory mechanism of the response to heat stress from the perspective of DNA methylation in S. japonica . We firstly obtained the characteristics of variation in the methylome under heat stress, and observed that heat stress caused a slight increase in the overall methylation level and methylation rate, especially in the non‐coding regions of the genome. Secondly, we noted that methylation was probably one of factors affecting the expression of genes, and that methylation within the gene body was positively correlated with the gene expression (rho = 0.0784). Moreover, it was found that among the differentially expressed genes regulated by methylation, many genes were related to heat stress response, such as HSP gene family, genes of antioxidant enzymes, genes related to proteasome‐ubiquitination pathway, and plant cell signaling pathways. This study demonstrated that DNA methylation is involved in regulating the response to heat stress, laying a foundation for studying the acclimation and adaptation of S. japonica to heat stress from an epigenetic perspective.

Liu, Fuli↗