A Novel Steam Condenser with Loop Thermosyphons and Film-Forming Agents for Improved Heat Transfer Efficiency and Durability

In this DOE/NETL BAA program, Advanced Cooling Technologies, Inc. (ACT), with Suez Water Technologies & Solutions (Suez), developed film-forming amine coatings applied to condenser surfaces that incorporated loop thermosyphons to enhance steam surface condenser performance and efficiency for coal-fired power plants. The condensation phenomenon resulting from these coatings promotes efficient dropwise condensation without additional thermal resistance through the use of film-forming amines (FFA). The loop thermosyphon technology was being developed to supplant current pumped cooling water systems to reduce operations and maintenance issues, reduce energy use, and promote high thermal performance. Both of ACT’s advanced coating and loop thermosyphon technologies were developed for application to wet cooling and indirect dry cooling systems. Internal steam condensation and subsequent heat dissipation complete the thermodynamic power cycle used by power plant cooling systems. The successful 3-year project period delved into understanding the experimental performance gain using film-forming amines applied to flat and tubular condenser surfaces under realistic operating conditions. The performance gain was used to create a technoeconomic analysis to more clearly understand the market value for power plants using FFA coatings to achieve dropwise condensation on condenser surfaces. A tall (50 ft.) loop thermosyphon was designed, fabricated, and tested to optimize the performance characteristics by tuning the working fluid charge and determining the temperature drop across the loop at different heat loads. Commercialization opportunities were explored to transition the loop thermosyphon work into the building HVAC market.

20 FOSSIL-FUELED POWER PLANTS↗

Final Scientific/Technical Report-FREE-piston Zero Emissions Refrigerator (FREEZER)

The FREE-piston Zero Emissions Refrigerator (FREEZER™) is a natural refrigerant Stirling-cycle cooler developed by AMSC in partnership with Heatcraft, targeted as a replacement refrigeration system for walk-in coolers or freezers found commonly in restaurants, convenience stores, supermarkets, etc. The FREEZER™, combined with a closed-loop CO2 heat-transfer system, had the goal to provides an efficient (Target COP = 1.4), zero ODP (Ozone Depletion Potential) and near zero GWP (Global Warming Potential) refrigeration solution with no synthetic, flammable, or toxic refrigerants. Other near zero GWP refrigeration systems do not exist at the scale and performance level of FREEZER. ARPA-E Continuation Funding enabled the design and fabrication of one Advanced Development Unit (ADU) cooler and two Field Test Unit (FTU) coolers, and a new revised Field Test Unit (new FTU). Heatcraft was to extensively test the various coolers at their facilities, which closely simulate real-world conditions. The original plan was to install and operate FREEZER FTUs alongside a traditional cooling solution at one or more customer locations to obtain data on direct performance comparisons with existing commercial refrigeration systems. Success in this FREEZER refinement and field-test project will establish the basis for a new class of environmentally friendly refrigeration systems that will revolutionize the industry. The hardware developed under the program is shown below in Figure 1. Five Stirling-cycle machines were built within the program, with a sixth cooler still under construction. The original DU and the ADU coolers met the performance target with a coefficient of performance (COP) of 1.2. The FTU was underperforming during the initial tuning of the free-piston Stirling cycle dynamics when there was a catastrophic failure of the fasteners on pressure boundary. This caused a pause to the program while the failure mechanism was investigated. The root cause was an inadequate flange design that allowed an excessive cyclic loading on the fasteners, leading to a fatigue failure. It was determined that existing FTU design could not be reasonably salvaged in a safe manner, and that fact, combined with the lower-than-expected performance of the new experimental heat exchanger modules lead to the design of the “new FTU” with a more conventional shell-and-tube heat exchanger design which should get close to the design target COP of 1.4, but have a higher overall machine cost. The program ran out of time before the fabrication of the new FTU was completed, but AMSC is still working on the cooler, with the majority of the parts fabricated, and hopes to have the unit under test sometime in early 2022, after which it will be shipped to Heatcraft for additional testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermoelectric-enhanced, liquid-based cooling of a multi-component electronic system

Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled structure, a thermal conduction path coupling the electronic component and the liquid-cooled structure, a coolant loop in fluid communication with a coolant-carrying channel of the liquid-cooled structure, and an outdoor-air-cooled heat exchange unit coupled to facilitate heat transfer from the liquid-cooled structure via, at least in part, the coolant loop. The thermoelectric array facilitates transfer of heat from the electronic component to the liquid-cooled structure, and the heat exchange unit cools coolant passing through the coolant loop by dissipating heat from the coolant to outdoor ambient air. In one implementation, temperature of coolant entering the liquid-cooled structure is greater than temperature of the outdoor ambient air to which heat is dissipated.

42 ENGINEERING↗

Thermoelectric-enhanced, liquid-based cooling of a multi-component electronic system

Methods are provided for facilitating cooling of an electronic component. The methods include providing: a liquid-cooled structure, a thermal conduction path coupling the electronic component and the liquid-cooled structure, a coolant loop in fluid communication with a coolant-carrying channel of the liquid-cooled structure, and an outdoor-air-cooled heat exchange unit coupled to facilitate heat transfer from the liquid-cooled structure via, at least in part, the coolant loop. The thermoelectric array facilitates transfer of heat from the electronic component to the liquid-cooled structure, and the heat exchange unit cools coolant passing through the coolant loop by dissipating heat from the coolant to outdoor ambient air. In one implementation, temperature of coolant entering the liquid-cooled structure is greater than temperature of the outdoor ambient air to which heat is dissipated.

47 OTHER INSTRUMENTATION↗

Waste Heat Recovery from the Advanced Test Reactor Secondary Coolant Loop

This study investigated the feasibility of using a waste heat recovery system (WHRS) to recover heat from the Advanced Test Reactor (ATR) secondary coolant system (SCS). This heat would be used to preheat air for space heating of the reactor building, thus reducing energy consumption, carbon footprint, and energy costs. Currently, the waste heat from the reactor is rejected to the atmosphere via a four-cell, induced-draft cooling tower. Potential energy and cost savings are 929 kW and $285K/yr. The WHRS would extract a tertiary coolant stream from the SCS loop and pump it to a new plate and frame heat exchanger, from which the heat would be transferred to a glycol loop for preheating outdoor air supplied to the heating and ventilation system. The use of glycol was proposed to avoid the freezing issues that plagued and ultimately caused the failure of a WHRS installed at the ATR in the 1980s. This study assessed the potential installation of a new WHRS for technical, logistical, and economic feasibility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal and Mechanical Energy Performance Analysis of Closed-loop Systems in Hot-Dry-Rock and Hot-Wet-Rock Reservoirs

To understand the potential and limitations for recovering thermal and mechanical energy from closed-loop geothermal systems a collaborative study is underway that will investigate an array of system configurations, working fluids, geothermal reservoir characteristics, operational periods, and heat transfer enhancements. Closed-loop geothermal systems are distinguished from hydrothermal or enhanced geothermal systems (EGS) in that the working fluid only circulates through drilled boreholes. Principal objectives of this study are to determine upper limits for thermal and mechanical energy recovery and optimal operational and configuration parameters for each scenario. Teams of scientists and engineers are applying a suite of numerical simulation and analytical tools to model the heat recovery from closed-loop geothermal systems, and then optimizing operational and configuration parameters to maximize the thermal and mechanical energy recovery. Results from the suite of numerical simulators and analytical tools, such as outlet and inlet states and temperature profiles in the geothermal reservoir over time are intercompared to increase confidence in the analysis. This paper documents the study findings for closed-loop systems in hot-dry-rock and hot-wet-rock reservoirs, where water is the working fluid. The characteristics of the hot-dry-rock reservoir were based on the U.S. Department of Energy's Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site, near Milford Utah. Two objective functions are defined to optimize the operational and configuration parameters of the system, one each for the recovery of mechanical and thermal energy over the period of operation. For both objective functions, a surface plant thermal to mechanical energy conversion factor and an energy drilling cost is required. In keeping with the study objectives the surface plant conversion factor is determined from a second-law of thermodynamics analysis of a generic binary plant, and drilling costs are based on those from the Utah FORGE site and current national electrical costs.

closed-loop geothermal systems↗

Thermal and Mechanical Energy Performance Analysis of Closed-loop Systems in Hot-Dry-Rock and Hot-Wet-Rock Reservoirs

To understand the potential and limitations for recovering thermal and mechanical energy from closed-loop geothermal systems a collaborative study is underway that will investigate an array of system configurations, working fluids, geothermal reservoir characteristics, operational periods, and heat transfer enhancements. Closed-loop geothermal systems are distinguished from hydrothermal or enhanced geothermal systems (EGS) in that the working fluid only circulates through drilled boreholes. Principal objectives of this study are to determine upper limits for thermal and mechanical energy recovery and optimal operational and configuration parameters for each scenario. Teams of scientists and engineers are applying a suite of numerical simulation and analytical tools to model the heat recovery from closed-loop geothermal systems, and then optimizing operational and configuration parameters to maximize the thermal and mechanical energy recovery. Results from the suite of numerical simulators and analytical tools, such as outlet and inlet states and temperature profiles in the geothermal reservoir over time are intercompared to increase confidence in the analysis. This paper documents the study findings for closed-loop systems in hot-dry-rock and hot-wet-rock reservoirs, where water is the working fluid. The characteristics of the hot-dry-rock reservoir were based on the U.S. Department of Energy’s Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site, near Milford Utah. Two objective functions are defined to optimize the operational and configuration parameters of the system, one each for the recovery of mechanical and thermal energy over the period of operation. For both objective functions, a surface plant thermal to mechanical energy conversion factor and an energy drilling cost is required. In keeping with the study objectives the surface plant conversion factor is determined from a second-law of thermodynamics analysis of a generic binary plant, and drilling costs are based on those from the Utah FORGE site and current national electrical costs.

Closed-loop geothermal systems, hot-dry-rock, hot-↗

Thermal Control System of the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS)

The ECOSystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) is a thermal infrared imaging multispectral scanner science mission. ECOSTRESS is designed and built by the NASA Jet Propulsion Laboratory and will be deployed on the International Space Station (ISS). ECOSTRESS will measure the water loss from growing leaves and the evaporation from the soil by measuring the temperature of plants and will gather data on the health of the agriculture system on Earth. The ISS orbit will allow ECOSTRESS to take observations at different times during each day over the seasons to provide coverage over the contiguous United States. The ECOSTRESS Thermal Control System (TCS) consists of a combination of active and passive components to maintain the ECOSTRESS components within the allowable flight temperature (AFT) limits. The active thermal control systems include mechanical cryocoolers, heaters and a single-phase pumped fluid loop for Instrument and Payload. The focal plane detector is cooled to 65K by a pair of mechanical cryocoolers and a third mechanical cryocooler cools an intermediate cold shield to 130K. The pumped fluid loop transfers the instrument waste heat to JAXA’s Japanese Exposed Module External Facility (JEM-EF) provided external fluid loop before rejection to space from the ISS radiators. The passive TCS includes multi-layer and single layer insulations, flexible thermal links and coatings on the radiometer. This paper describes the ECOSTRESS instrument TCS architecture, instrument thermal requirements and key design drivers, the top level thermal design and analysis approach, and reports preliminary test results.

Carroll, Brian↗

Development of a Forced-Convection Liquid-Fluoride-Salt Test Loop

A small forced-convection molten-fluoride-salt loop is being constructed at Oak Ridge National Laboratory to examine the heat transfer behavior of FLiNaK salt in a heated pebble bed. Objectives of the experiment include reestablishing infrastructure needed for fluoride-salt loop testing, developing a unique inductive heating technique for performing heat transfer (or other) experiments, measuring heat transfer characteristics in a liquid-fluoride-salt-cooled pebble bed, and demonstrating the use of silicon carbide (SiC) as a structural component for salt systems. The salt loop will consist of an Inconel 600 piping system, a sump-type pump, a SiC test section, and an air-cooled heat exchanger, as well as auxiliary systems needed to pre-heat the loop, transport salt into and out of the loop, and maintain an inert cover gas over the salt. A 30,000 Hz inductive heating system will be used to provide up to 250 kW of power to a 15 cm diameter SiC test section containing a packed bed of 3 cm graphite spheres. A SiC-to-Inconel 600 joint will use a conventional nickel/grafoil spiral wound gasket sandwiched between SiC and Inconel flanges. The loop system can provide up to 4.5 kg/s of salt flow at a head of 0.125 MPa and operate at a pressure just above atmospheric. Pebble Reynolds numbers of up to 2600 are possible with this configuration. A sump system is provided to drain and store the salt when not in use. Instrumentation on the loop will include pressure, temperature, and flow measurements, while the test section will be instrumented to provide pebble and FLiNaK temperatures.

36 MATERIALS SCIENCE↗

A bi-directional two-phase/two-phase heat exchanger

This paper describes the design and test of a heat exchanger that transfers heat from one two-phase thermal loop to another with very small drops in temperature and pressure. The heat exchanger condenses the vapor in one loop while evaporating the liquid in the other without mixing of the condensing and evaporating fluids. The heat exchanger is bidirectional in that it can transfer heat in reverse, condensing on the normally evaporating side and vice versa. It is fully compatible with capillary pumped loops and mechanically pumped loops. Test results verified that performance of the heat exchanger met the design requirements. It demonstrated a heat transfer rate of 6800 watts in the normal mode of operation and 1000 watts in the reverse mode with temperature drops of less than 5 C between two thermal loops.

Ku, Jentung↗

Development of a contact heat exchanger for a constructable radiator system

A development program for a contact heat exchanger to be used to transfer heat from a spacecraft coolant loop to a heat pipe radiator is described. The contact heat exchanger provides for a connectable/disconnectable joint which allows for on-orbit assembly of the radiator system and replacement or exchange of radiator panels for repair and maintenance. The contact heat exchanger does not require the transfer of fluid across the joint; the spacecraft coolant loop remains contained in an all welded system with no static or dynamic fluid seals. The contact interface is also "dry' with no conductive grease or interstitial material required.

Howell, H. R.↗

Analysis & Tools to Spur Increased Deployment of “Waste Heat” Rejection/Recycling Hybrid Ground-source Heat Pump Systems in Hot, Arid or Semiarid Climates Like Texas

This project team analyzed supplemental heat rejection/recovery (SHR) devices or systems that could be used in hybrid ground source heat pump (HGHP) systems located in arid or semi-arid regions in southwestern U.S. Identification of effective SHR solutions would enhance the deployment of ground source heat pumps (GHP) in these regions. In a parallel effort, the team developed integrated GHP models that coupled the building load, heat pump, and ground loop subsystems and which could be applied to residential and commercial office buildings. Then GHP and HGHP performances could be compared in terms of operational performance and life-cycle costs. Several potential SHR devices were analyzed by applying two strategies: 1) to remove heat directly from the water in the ground loop before it enters the ground and 2) to remove heat in the refrigerant loop of the vapor compression cycle (VCC) of the heat pump so less heat is transferred to the water loop at the condenser of the VCC. Cooling towers, adsorption coolers, and thermoelectric liquid coolers were included in strategy 1, and expanded desuperheaters, thermosyphons, and an optimized VCC were included in strategy 2. Of all SHR devices analyzed, only the cooling tower provided a cost-effective performance enhancement. For the integrated GHP model, the project team selected the building load model HAMBASE and its powerful computational Simulink/MatLab platform, empirical performance map models of the heat pumps based upon manufacturers’ performance data, and a ground loop model developed by Oklahoma State University and rewritten for this project in Simulink/MatLab. The design process used GLHEPRO, also from Oklahoma State University, to size the borehole fields. The building load and ground loop models were compared with simulations from eQuest, ASHRAE 140-2008 standards, EnergyPlus, and GLHEPRO and were found to predict those subsystems’ performance well. The integrated GHP model was applied to a 195m 2 (2100ft 2 ) residential building and a 4,982m 2 (53,628ft 2 ) three-story commercial office building, and it ran 10-15 year simulations. The integrated GHP model and its Simulink platform provided residential data, ranging from seconds to years, and commercial office building data, ranging from minutes to years. A cooling tower model was coupled to the base case integrated GHP model for the residential building and the resulting HGHP system provided a cost-effective solution for the Austin, TX location. Simulations for both the residential and commercial building models were run with varying degrees of SHR (device/system not identified) and the results were found to significantly decrease installation costs, increase heat pump efficiency (lower entering water temperature), and prolong the lifetime of the borehole field. Lifetime cycle costs were estimated from the simulation results. Sensitivity studies on system operating performance and lifetime costs were performed on design parameters, such as construction materials, borehole length, borehole configuration and spacing, grout conductivity, and effects of SHR. While some of the results are intuitive, these studies provided quantitative estimates of improved performance and cost. One of the most important results of this sensitivity study is that overall system performance is very sensitive to these design parameters and that modeling and simulation are essential tools to design cost-effective systems.

15 GEOTHERMAL ENERGY↗

Experimental study on heat transfer to supercritical water flowing through tubes

A test facility named SWAMUP (Supercritical Water Multi-Purpose Loop) has been constructed in Shanghai Jiao Tong Univ. to investigate heat transfer and pressure drop through tubes and rod bundles. SWAMUP is a closed loop with operating pressure up to 30 MPa, outlet-water temperature up to 550 deg. C, and mass flow rate up to 5 t/h. In this paper, experimental study has been carried out on heat transfer of supercritical water flowing vertically through tubes (ID=7.6 and 10 mm). A large number of test points in tubes has been obtained with a wide range of heat flux (200-1500 kw/m{sup 2}) and mass flux (450-2000 kg/m{sup 2}s). Test results showed that heat transfer deterioration (HTD) caused by buoyancy effect only appears in upward flow and HTD caused by acceleration effect appears both in upward flow and downward flow. The heat transfer coefficients (HTC) produced in tube tests were compared with existing heat transfer correlations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System-Level Heat Transfer Analysis, Thermal- Mechanical Cyclic Stress Analysis, and Environmental Fatigue Modeling of a Two-Loop Pressurized Water Reactor. A Preliminary Study

This report provides an update on an assessment of environmentally assisted fatigue for light water reactor components under extended service conditions. This report is a deliverable in April 2015 under the work package for environmentally assisted fatigue under DOE's Light Water Reactor Sustainability program. In this report, updates are discussed related to a system level preliminary finite element model of a two-loop pressurized water reactor (PWR). Based on this model, system-level heat transfer analysis and subsequent thermal-mechanical stress analysis were performed for typical design-basis thermal-mechanical fatigue cycles. The in-air fatigue lives of components, such as the hot and cold legs, were estimated on the basis of stress analysis results, ASME in-air fatigue life estimation criteria, and fatigue design curves. Furthermore, environmental correction factors and associated PWR environment fatigue lives for the hot and cold legs were estimated by using estimated stress and strain histories and the approach described in NUREG-6909. The discussed models and results are very preliminary. Further advancement of the discussed model is required for more accurate life prediction of reactor components. This report only presents the work related to finite element modelling activities. However, in between multiple tensile and fatigue tests were conducted. The related experimental results will be presented in the year-end report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Power Generation Cycle with RELAP-7

Balance of plant of a High-Temperature gas-cooled Reactor – Pebble bed Module (HTR-PM) is modeled using RELAP-7. The model includes the primary helium loop where the heat produced by the core is transferred to a helical-coil steam generator and the secondary loop where super-heated steam is fed to a turbine to extract power. The steam is then condensed to subcooled water and pumped back into the steam generator. Results demonstrate that RELAP-7 has the capability to model different regimes encountered in two-phase flow with wall boiling, superheated steam, subcooled liquid and condensation. RELAP-7 also has the capability of modeling different fluids with their own specific models in a very flexible way, without any code change. This also demonstrates the capability of modeling the transfer of fission power into electrical power.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Miniature Heat Transport System for Spacecraft Thermal Control

Loop heat pipes (LHP) are efficient devices for heat transfer and use the basic principle of a closed evaporation-condensation cycle. The advantage of using a loop heat pipe over other conventional methods is that large quantities of heat can be transported through a small cross-sectional area over a considerable distance with no additional power input to the system. By using LHPs, it seems possible to meet the growing demand for high-power cooling devices. Although they are somewhat similar to conventional heat pipes, LHPs have a whole set of unique properties, such as low pressure drops and flexible lines between condenser and evaporator, that make them rather promising. LHPs are capable of providing a means of transporting heat over long distances with no input power other than the heat being transported because of the specially designed evaporator and the separation of liquid and vapor lines. For LHP design and fabrication, preliminary analysis on the basis of dimensionless criteria is necessary because of certain complicated phenomena that take place in the heat pipe. Modeling the performance of the LHP and miniaturizing its size are tasks and objectives of current research. In the course of h s work, the LHP and its components, including the evaporator (the most critical and complex part of the LHP), were modeled with the corresponding dimensionless groups also being investigated. Next, analysis of heat and mass transfer processes in the LHP, selection of the most weighted criteria from known dimensionless groups (thermal-fluid sciences), heat transfer rate limits, (heat pipe theory), and experimental ratios which are unique to a given heat pipe class are discussed. In the third part of the report, two-phase flow heat and mass transfer performances inside the LHP condenser are analyzed and calculated for Earth-normal gravity and microgravity conditions. On the basis of recent models and experimental databanks, an analysis for condensing two-phase flow regimes, pressure gradients, and local heat transfer coefficients using ammonia, propylene, and R134, are carried out.

Ochterbeck, Jay M.↗

Analysis of ELAP and mitigation strategies in Maanshan PWR with PCTRAN

On March 11, 2011, the Fukushima Daiichi Nuclear Power Plant, owned by Tokyo Electric Power Company, encountered a beyond design basis earthquake/tsunami and the flood crippled the on-site emergency power and electric transmission systems. The ELAP (Extended Loss of Alternating Current Power) and LUHS (Loss of Ultimate Heat Sink) events severely damaged the core cooling systems and the safety functions of the containment. As a result, three reactor cores were damaged. Also, the cooling capability of nuclear spent fuel pools was lost due to loss of AC and DC power. Existing Station Blackout (SBO) analyses have demonstrated that even with leakage from Reactor Coolant Pump (RCP) seals, the core could maintain coolable only when heat transfer exists between primary loop and secondary loop. Depend on the availability of DC power in different plant designs, the SBO coping times were shown to be 4 to 16 hours. According to INPO event report, it is necessary to analyze the consequences if current coping times are extended with increased core water inventory loss from pump seals. In an ELAP scenario, all active system including Emergency Core Cooling System (ECCS) and motor driven AFW were out of power supply, results in degradation of core cooling capability. Moreover, the fuel exposed risk would increase due to continuously Reactor Coolant System (RCS) inventory loss through pump seals. Therefore, mitigation strategy must be applied prior to core uncovering to prevent its damage and assure plant safety. This research utilized a fast running NPP safety simulation code, PCTRAN, to assess reactor performances in the situations of ELAP of Maanshan PWR. Also, the sensitivity study of injection flow rates and effectiveness of mitigation strategy were demonstrated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗