Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat transfer coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Heat Transfer and Pressure Drop Characteristics of Water Flow Boiling in Internally Enhanced Tubes

Flow boiling is a critical process for many thermal conversion processes such as HVAC&R, water heating, power generation and desalination applications. The major goal of this paper is to enhance the in-tube heat transfer for flow boiling of water and further improve the efficiency of the boiler. This paper presents an experimental investigation of the heat transfer and pressure drop characteristics for water under forced convection and boiling conditions inside both smooth and enhanced tubes. The results in the smooth copper tube are compared with several correlations and used as a baseline. The two-phase heat transfer and pressure drop performance of the water flow boiling in the internally enhanced tube is investigated, and the influence of internal surface pattern on the thermal characteristics is discussed. The relations of the heat transfer coefficient with mass flux, heat flux and vapor quality are analyzed according to the results.

Yang, Cheng-Min↗

Sensitivity study on the fin effect of thermocouple mounted on the heated surface under film boiling condition

In the reactivity-initiated accident (RIA) scenario, right after the power burst with the occurrence of departure from nucleate boiling (DNB), the cladding temperature quickly reaches its maximum and is maintained in a steady film boiling regime. Then, under limited heat transfer performance of film boiling, the local cooling effect by the thermocouple wire may not be neglected. A computational model is developed to estimate the local cooling effect of the thermocouple wire mounted on the cladding surface under film boiling condition. The model predicts the temperature profile along the cladding surface as physically expected and is verified against the benchmark problem. Sensitivity studies reveal the significant effects of the thickness of vapor film layer and the diameter of thermocouple on the temperature drop near the thermocouple, for they increase the heat transfer area to the liquid water region. The impact of film boiling heat transfer coefficient, however, is not significant, as the primary heat transfer mechanism near the thermocouple is the heat conduction to the wire. Future study will include the contribution of radiative heat transfer between the cladding surface and the vapor film layer, as well as a transient power history which represents an actual RIA scenario.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cast or Additively Manufactured Coils with End Turn Enhanced Heat Transfer Surfaces for Spray or Jet Cooling

Cast or additively manufactured coils present a new opportunity for creativity in thermal management of electric machines. Improvements to the heat transfer of spray or jet cooling of coil end turns through the incorporation of pins or enhanced heat transfer surfaces in the cast end turn surfaces is explored. The thermal response of cast copper half-turns is measured for a range of spray/jet volumetric flow rates and ohmic loss heat fluxes. A significant reduction, ~30%, in the steady state temperature and increased spray cooling heat transfer coefficients was experimentally measured when the pins or enhanced heat transfer surfaces are incorporated.

33 ADVANCED PROPULSION SYSTEMS↗

TRUST Sensors in Environments: Thermocouples (SE-TC), Release FY25

The Delivery Environments Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is a broad project intended to analyze simplified problems experimentally and with modeling and simulation. The purpose of analyzing these simplified problems is to extend solution methods to more complex problems, as well as understand deficiencies and gaps in knowledge of methods currently used in more complex analyses. The TRUST project encompasses several smaller testbeds intended to isolate individual phenomena. The testbed under consideration in this report is the Sensors in Environments: Thermocouples testbed. In previous years, the purpose of this testbed was to quantify uncertainty of thermocouple sensors. To accomplish this, an aluminum plate was placed in a thermal chamber and subject to various types of thermal loading. Thermocouples were placed in various locations on the aluminum plate in various configurations (e.g., embedded in the plate, placed under Kapton tape), and an effort was made to quantify uncertainty in these measurements. Finite element simulations were performed to investigate how sensitive these measurements were to parameters such as the boundary conditions on the plate and material properties. However, a fundamental source of uncertainty in this analysis was the convective heat transfer from the plate. Convective heat transfer is a complex physical phenomenon comprised of a number of interacting sub-processes and is difficult to predict accurately a priori. As such, the main purpose of this testbed in FY25 was to better understand, both experimentally and numerically, the convective heat transfer from the plate. This is a highly applicable problem to several more complex problems, as convective heat transfer occurs in nearly all problems where a body is moving through air. Numerically, this required a two-step approach. First, the air flow in the thermal chamber was in vestigated using computational fluid dynamics. The commercial solver Fluent was used to perform these simulations. From these simulations, a heat transfer coefficient over the surface of the plate was calculated. This heat transfer was then used as boundary conditions for finite element heat transfer simulations within the plate, which were performed using Abaqus. Significant effort was devoted to automating the handoff between these two solvers. Experimentally, previous thermocouple results in the plate were used to validate the time-dependent thermal profiles produced from Abaqus. Further experimental efforts were performed both to help validate the Fluent simulations and to inform its boundary conditions. For example, hot-wire anemometers were used to measure the velocity in the chamber, which would be particularly useful in understanding the chamber inlet velocity. Thermocouple measurements were also taken in the chamber, instead of only on the plate, to serve as validation evidence for the Fluent simulations. Numerical results showed that the Fluent to Abaqus workflow matched previous plate thermocouple measurements well. This type of handoff is useful for more complex experiments, or those that are not able to be examined in as great of detail as this testbed, as it was performed without any experimental input. Experimental results, however, were more mixed. The anemometers proved unreliable, with inconsistent measurements across all anemometers, even at locations that were nearly identical. On the other hand, the thermocouples provided a relatively rich view of the temperature field in the chamber.

42 ENGINEERING↗

Heat pulse testing at monitoring wells to estimate subsurface fluid velocities in geological CO 2 storage

Monitoring the injected CO 2 during geological CO 2 storage (GCS) is essential to assure containment and identify CO 2 leakage. Here in this work, a new approach is introduced to estimate the evolution of the downhole fluid velocity at a monitoring well and identify CO 2 arrival time using in-well heat pulse/tracer test. The proposed technique involves using a downhole heater to generate a series of heat pulses and measuring their corresponding temperature response. The surface temperature of the downhole heater is controlled by the supplied electrical power and the heat loss by convection to the surroundings. Convective heat transfer is well described using Newton's law of cooling in which the temperature difference between the heater and the surrounding fluids drives the heat transfer, for which the convection heat transfer coefficient (h) controls the magnitude of heat loss. Among various factors that control h, it depends on the type of the flowing fluid and its velocity. Through analyzing the measured temperature at different heat pulses, the changes in h - due to mobilization of the in-situ brine or CO 2 arrival - can be estimated. Consequently, the velocity of the flowing fluid across the heater can be obtained. Since heat transfer by convection is sensitive to the type of the surrounding fluid, intrusion of CO 2 can be detected from the relatively higher surface temperature obtained at CO 2 arrival. Churchill and Bernstein (1977)'s correlation is adopted to estimate the change of fluid velocity in terms of the change in h. To demonstrate the validity of the proposed technique, the results are applied and validated against those of COMSOL Multiphysics simulation tool for single-phase brine (before CO 2 arrival) and single-phase CO 2 (after CO 2 arrival). The observed temperature heating is sensitive to the flowing fluid velocity and fluid type. The temperature signal observed at CO 2 arrival is large and easily detectable using temperature monitoring tool which provides reliable indication for tracking CO 2 arrival at monitoring wells compared with passive temperature monitoring. The results obtained using the proposed technique agree very well with the numerical results obtained from the simulation tool with a maximum estimation error of 7 percent.

02 PETROLEUM↗

Enhanced Pool Boiling of Low-Pressure Refrigerants on Round Tubes- An Experimental Evaluation

Pool boiling heat transfer is one of the most effective heat transfer methos and crucial for several energy conversion processes such as electronic cooling, steam generation, water purification and thermal management. Enhancing boiling heat transfer around the tubes enables higher heat flux, which can improve the efficiency and lead to compact heat exchangers. Delaying the onset of critical heat flux (CHF) allows for higher CHFs and protects equipment during anomalous transient conditions. Growing interest in process intensification and delayed CHF has motivated the current study. An experimental approach has been deployed to investigate a potential technique to enhance the pool boiling performance around small diameter tubes by open cell metal foams. The findings for nucleate pool boiling of Novec HFE 7000 on the externally enhanced and smooth tubes are reported. The enhanced tube comprised of compressed aluminum foam brazed around. All the samples were horizontally oriented, and the experiments were performed under ambient pressure conditions. The heat transfer measurements for the smooth tubes were compared with several existing correlations and established the baseline. The preliminary results showed that the aluminum foam effectively enhanced the heat transfer coefficient and delayed the onset of critical heat flux. In addition, the pool boiling process around the round tube sample was visualized from both side and front views to comprehend the heat transfer mechanisms underlying substantial enhancement observed during experiments.

Yang, Cheng-Min↗

In tube condensation of low global warming potential refrigerants in an axial micro-fin aluminum tube

Environmental regulations have driven the development of refrigerants with low global warming potential (GWP). To design heat exchangers using these new refrigerants, data are needed concerning the heat transfer coefficient and pressure drop in two-phase flow. Another change is the increasing use of aluminum tubes rather than copper tubes to reduce heat exchanger cost. Hence, this study presents an experimental investigation of flow condensation using an expanded axial micro-fin aluminum tube with a fin-tip diameter of 5.96 mm. Here, the experiments included single compounds R-32, R-1234yf, and R-1234ze(E), zeotropic mixtures with low glide (R-454B), and zeotropic mixtures with high-glide (R-454C and R-455A). Experiments were conducted at condensation temperatures ranging from 40 °C to 50 °C, reduced pressures ranging from 0.21 to 0.55, and mass fluxes ranging from 150 to 350 kg/(m 2 s). Data obtained for these refrigerants constitute one of the first reports for high-glide refrigerants using axial micro-fin aluminum tubes. An evaluation of heat transfer degradation of zeotropic mixtures due to mass transfer resistance at the liquid/vapor interface is presented. This information can be used to design heat exchangers for next generation air conditioning and refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods for Measuring and Computing the Reference Temperature in Newton’s Law of Cooling for External Flows

Newton’s law of cooling requires a reference temperature (𝑇 𝑟𝑒𝑓 ) to define the heat-transfer coefficient (ℎ). For external flows with multiple temperatures in the freestream, obtaining 𝑇 𝑟𝑒𝑓 is a challenge. One widely used method, referred to as the adiabatic-wall (AW) method, obtains 𝑇 𝑟𝑒𝑓 by requiring the surface of the solid exposed to convective heat transfer to be adiabatic. Another widely used method, referred to as the linear-extrapolation (LE) method, obtains 𝑇 𝑟𝑒𝑓 by measuring/computing the heat flux ($𝑞^{′′}_𝑠$) on the solid surface at two different surface temperatures (𝑇 𝑠 ) and then linearly extrapolating to $𝑞^{′′}_𝑠$ = 0. A third recently developed method, referred to as the state-space (SS) method, obtains 𝑇 𝑟𝑒𝑓 by probing the temperature space between the highest and lowest in the flow to account for the effects of 𝑇 𝑠 or $𝑞^{′′}_𝑠$ on 𝑇 𝑟𝑒𝑓 . This study examines the foundation and accuracy of these methods via a test problem involving film cooling of a flat plate where $𝑞^{′′}_𝑠$ switches signs on the plate’s surface. Results obtained show that only the SS method could guarantee a unique and physically meaningful 𝑇 𝑟𝑒𝑓 where 𝑇 𝑠 =𝑇 𝑟𝑒𝑓 on a nonadiabatic surface $𝑞^{′′}_𝑠$ = 0. The AW and LE methods both assume 𝑇 𝑟𝑒𝑓 to be independent of 𝑇 𝑠 , which the SS method shows to be incorrect. Though this study also showed the adiabatic-wall temperature, 𝑇 𝐴𝑊 , to be a good approximation of 𝑇 𝑟𝑒𝑓 (<10% relative error), huge errors can occur in ℎ about the solid surface where |𝑇 𝑠 −𝑇 𝐴𝑊 | is near zero because where 𝑇 𝑠 =𝑇 𝐴𝑊 , $𝑞^{′′}_𝑠$ ≠ 0.

Newton's law of cooling↗

High-Performance Thermoelectric Generators for Field Deployments

Thermoelectric power generation is a reliable energy harvesting technique for directly converting heat into electricity. Recent studies have reported the thermal-to-electrical energy conversion efficiency of thermoelectric generators (TEGs) up to 11% under laboratory settings. However, the practical effectiveness of TEGs deployed under real environments is still not more than a few percent. In this study, we provide fundamental insight on the operation of TEGs in realistic environments by illustrating the combinatory effect of thermoelectric material properties, device boundary conditions, and environmental thermal resistivity on TEG performance in conjunction with the module parameters. Using numerical and experimental studies, we demonstrate the existence of a critical heat transfer coefficient that dramatically affects the design and performance of TEGs. Results provide a set of concrete design criteria for developing efficient TEGs that meet the metrics for field deployments. High-performance TEGs demonstrated in this study generated up to 28% higher power and 162% higher power per unit mass of thermoelectric materials as compared to the commercial module deployed for low-grade waste heat recovery. This advancement in understanding the TEG operation will have a transformative impact on the development of scalable thermal energy harvesters and in realizing their practical targets for efficiency, power density, and total output power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel Patterned Surfaces for Improved Condenser Performance in Power Plants

In this project, we seek to improve the thermoelectric power plant performance through engi-neered nonwetting condenser tube surface designs that can enhance heat transfer performance by: (1) promoting dropwise condensation of the steam on the shell side and eliminating flooding of the surface structure by maintaining low droplet adhesion, thus increasing condensation heat transfer coefficient; (2) deterring fouling and corrosion, thereby reducing fouling resistance and improving heat transfer; (3) possibly reducing drag and increasing convective heat transfer inside coolant tubes; and (4) reducing the number of tubes, coolant water usage, and levelized cost of condenser.

20 FOSSIL-FUELED POWER PLANTS↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pool boiling heat transfer characteristics of low-GWP refrigerants in a horizontal tube bundle configuration

Heat transfer enhancement techniques have been adapted on the shell side to improve the overall performance of the flooded evaporators, such as finned tubes. In recent years, it has been demonstrated that the metal foam structure can offer enhanced heat transfer performance under pool boiling conditions. However, there are not much research in the open literature that examine the feasibility of metal foam embedded tubes in horizontal tube bundle configurations. Therefore, this paper proposed a novel metal foam embedded tube (i.e., foam embedded outside the tube) to improve the heat transfer behavior of flooded evaporators. Further, the experiments were performed on a horizontal tube bundle with a staggered arrangement. Moreover, the performance of low global warming potential (GWP) refrigerants (R-1234yf and R-1234ze(E)) is compared against R-134a for both plain tubes and metal foam tubes with porosities of 81%, 75%, and 62%. The results showed that a metal foam tube with a porosity of 62% showed a maximum heat transfer coefficient (HTC) enhancement of 291% compared to the plain tube. As compared with R-134a, the HTCs of R-1234yf and R-1234ze(E) are nearly 10% higher and 5% lower, respectively.

42 ENGINEERING↗

In Tube Condensation Heat Transfer and Pressure Drop for R454B and R32—Potential Replacements for R410A

The heating, ventilation and air conditioning (HVAC) industry in the United States seeks near-term alternative refrigerants to replace R-410A in unitary equipment. Two potential replacement refrigerants are R-454B and R-32. It is of interest to investigate the capability and accuracy of existing heat exchanger design methods when applied to these replacement refrigerants. To that end, this work presents empirical condensation quasi-local heat transfer coefficient and pressure drop data for R-454B and R-32. These data were obtained in a $\frac{3}{8}$ in. (9.52 mm) outside diameter (OD) smooth copper tube with a wall thickness of 0.032 in. (0.81 mm). The experimental variables and their ranges included refrigerant absolute pressure ( 1960 ≤ P a b s ≤ 3196 kPa), condensation temperature ( 35 ≤ T c o n d ≤ 50 °C), mass flux ( 100 ≤ G ≤ 200 kg m -2 s -1 ), vapor quality ( 0 ≤ x ≤ 1 ), and heat flux ( 32.9 ≤ q ″ ≤ 62.97 kW m -2 ). It was found that the heat transfer correlation developed by Cavallini et al. Cavallini et al. (2006) predicted the experimental condensation heat transfer data, for both R-454B and R-32, with the greatest accuracy. Using the Cavallini et al. correlation, it was found that the mean absolute percentage error (MAPE) was 10.5% and 15.1% for R-454B and R-32, respectively. Additionally, the pressure drop correlation developed by Friedel Friedel (1979) predicted the experimentally determined pressure gradient with a MAPE of 7.7% and 5.5% for R-454B and R-32, respectively. These results will assist the practicing thermal engineer to choose the most appropriate design correlation for these near-term replacement refrigerants.

42 ENGINEERING↗

Designing slippery rough surfaces to enhance dropwise condensation of low surface tension fluid

Enhancing low surface tension liquid condensation is critical for achieving high energy efficiency and reducing the size of thermal energy systems. Extensive research has focused on promoting dropwise condensation of these liquids using state-of-the-art coatings on plain surfaces. However, maintaining dropwise condensation with low surface tension fluids is challenging due to rivulet formation, resulting in wetted tails that transition to filmwise condensation at elevated heat fluxes. Here, to address this issue, we uncover the role of surface structures and surface chemistry in the dropwise condensation of low surface tension ethanol on slippery rough surfaces (SRS). High-performance dropwise condensation has been achieved on slippery microchannels grafted with perfluoropolyether. The SRS uniquely facilitates rapid lateral droplet removal, enabling faster directional droplet shedding without rivulet formation. The resulting higher droplet removal frequency on SRS leads to heat transfer coefficients 100 % and 500 % higher than conventional dropwise and filmwise condensation on plain surfaces, respectively. Our findings uncover the pivotal role of rapid droplet removal through slippery microchannels in sustaining dropwise condensation of low surface tension liquids. This study introduces a new paradigm for promoting dropwise condensation using engineered SRS that incorporates surface structure and surface chemistry. The work will provide fundamental design guidelines to design efficient and compact condensers that use costly or flammable low global warming potential refrigerants in future refrigeration systems.

Dropwise condensation↗

Preliminary modeling of triply periodic minimal surface (TPMS) structures using RELAP5-3D

With the United States Department of Energy (DOE)’s goal of quadrupling the nation’s nuclear energy supply by 2050, and with the Advanced Fuels Campaign pushing for new types of advanced reactor fuels and geometries, the need has arisen for new nuclear fuel designs. One such design is to swap out current nuclear fuel geometries in exchange for another type of geometry, called a Triply Periodic Minimal Surface (TPMS). TPMSs are self-supporting, infinitely repeating lattices—attributes that lend themselves well to additive manufacturing. These surfaces also possess enhanced heat transfer properties thanks to their internal area changes and large surface-area-to-volume ratios. Their drawback, however, is an increased pressure drop. Given the small amount of correlations and data (Reynolds numbers in the 2,000–8,000 range), and the minimal amount of experience so far obtained by modeling TPMS structures using 1D systems codes such as the Reactor Excursion and Leak Analysis Program (RELAP5-3D), further research into this topic was needed. Using data from the University of Wisconsin - Madison (UW), curve fits were created for both a Heat Transfer Coefficient (HTC) correlation and a Darcy friction factor empirical coefficient correlation. The curves’ coefficients and multipliers were then output and utilized in RELAP5-3D models of two upcoming experiments—Flow Loop for INFLUX Pressure drop (FLIP) and Microreactor Agile Non-nuclear Experimental Test (MAGNET)—aimed at increasing the available data for Reynolds numbers to the 16,000–36,000 range for TPMS structures. The models were run under the conditions utilized by a Computational Fluid Dynamics (CFD) analysis performed by another group at Idaho National Laboratory. Only CFD pressure drop values were obtained from the FLIP test, and those values showed that the RELAP5-3D models had a lower rate of pressure increase in comparison to the CFD values. In addition, there seemed to be a vertical shift upward in the pressure drop for both models whenever the TPMS porosity decreased, and the RELAP5-3D models showed a higher vertical shift in comparison to the CFD values. The MAGNET results did not correspond to any CFD or experimental results against which they could be compared, so they were instead compared against the proposed CFD input conditions. These values were then compared with each other to make sure the model seemed to be performing as expected, paving the way for future tests that can be run for the purpose of further analyses and comparisons. The pressure drop increased with temperature and mass flow rate independently. The temperature change would decrease with increasing mass flow rate and temperature, which was just as we expected based on the fact that the lower viscosity and decreased density would result in higher friction and churning losses. The last metric that was assessed was the enthalpy flow change, which increased with increasing mass flow rate and decreasing temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A One-dimensional Heat Transfer Model for a Cooled Airfoil in a Direct-fired Supercritical CO 2 Turbine

A one-dimensional (1-D) heat transfer model was developed to predict the performance of a cooled airfoil for a supercritical carbon dioxide (sCO 2 ) turbine. The model included the effects of film cooling effectiveness, thermal barrier coating thickness, and internal Nusselt number augmentation. Trends for overall cooling effectiveness versus heat load parameter were obtained for over twelve unique thermal management schemes. The study found that adding a thermal barrier coating was the most effective scheme for increasing the airfoil overall cooling effectiveness. Internal cooling technologies have diminishing returns as the heat transfer coefficient augmentation increases past a factor of five, however the sensitivity of overall cooling effectiveness to heat transfer augmentation scales by a factor of 1.3 when a thermal barrier coating is introduced. Film cooling is seen as a long-term research area which will be inevitably explored as direct sCO 2 systems develop a market presence. However, the model indicates that realizable film cooling effectiveness levels yield a smaller improvement in overall cooling effectiveness than a thermal barrier coating.

42 ENGINEERING↗

Evaluation of Additively Manufactured Monolithic SiC and SiC Ceramic Matrix Composites for Concentrating Solar Receiver Applications

Supported by an award from the Solar Technology Office, US Department of Energy, GE Aerospace Research in collaboration with Heliogen Holdings Inc, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR). We report the results of our study of the effective heat transfer characteristic of several candidate structure motifs, or feature geometries, made of SiC via additive manufacturing in a simulative laboratory test. The SiC structure motifs studied include different permutations of three-dimensional periodic lattices and defined shapes. The solar-thermal simulating laboratory test setup is constructed using a 4kW CO2 laser system with beam shaping optics to apply radiative heating power on one face of 2”-diameter cylindrical feature specimens representing the structure motifs of interest for receiver element design. Using the test setup, simulative test conditions representative of a concentrated solar flux of up to ~2000 suns could be achieved in the lab tests under varying air flow through the test structure. A numerical analysis scheme is developed to extract an effective or compound heat transfer coefficient representative of the test structure under steady-state heat flow conditions.

14 SOLAR ENERGY↗

Role of Three-Dimensional Swirl in Forced Convection Heat Transfer Enhancement in Wavy-Plate-Fin Channels

The influence of wall-corrugation-induced swirl flow on enhanced forced convection in wavy-plate-fin cores has been investigated. Three-dimensional computational simulations were carried out for steady-state periodically developed air flow (Pr ~ 0.71; 50 ≤ Re ≤ 4000) with channel walls subject to constant-uniform temperature conditions. The recirculation that develops in the wall troughs and grows to have an axially helical character is scaled by the Swirl number Sw. As Sw increases with higher flowrate and/or corrugation severity, tornado-shaped vortices appear in the wave trough region midway of the interfin channel height, then extend longitudinally to encompass majority of the flow channel. The local wall-shear and heat transfer coefficient variations indicate that boundary-layer thinning upstream of the wave peak aids in intensifying momentum and heat transfer. However, the flow recirculation in wall trough impedes heat transfer at low Sw due to flow stagnation but promotes it at high Sw because of the vortices-induced augmented fluid mixing. The effects of this secondary flow are quantified by Φf(or j), which is seen to increase log-linearly as fin corrugation aspect ratio γ and/or fin spacing ratio ζ increases; the influence of cross section aspect ratio α is marginal. Moreover, the pressure drag penalty due to swirl critically affects overall pressure loss, and its proportion remains nearly constant when α varies, but grows as Sw, γ, and/or ζ increases and can be as much as 80% of the total pressure drop.

Engineering↗