Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat of absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Predicting Moisture Absorption in Composite Materials

Heat transport programs adaptable for absorption analysis. Lightweight sandwich panel specimen used for comparison of water absorption measurements with program predictions. In program model, moisture -- like heat in heat-transport problem moves through variety of materials and structures along complex paths.

Haines, J. R.↗

Moderate temperature control technology for a lunar base

A parametric analysis is performed to compare different heat pump based thermal control systems for a Lunar Base. Rankine cycle and absorption cycle heat pumps are compared and optimized for a 100 kW cooling load. Variables include the use or lack of an interface heat exchanger, and different operating fluids. Optimization of system mass to radiator rejection temperature is performed. The results indicate a relatively small sensitivity of Rankine cycle system mass to these variables, with optimized system masses of about 6000 kg for the 100 kW thermal load. It is quantitaively demonstrated that absorption based systems are not mass competitive with Rankine systems.

Swanson, Theodore D.↗

Solar energy absorption characteristics and the effects of heat on the optical properties of several coatings

The solar energy absorption characteristics of several high temperature coatings were determined and effects of heat on these coatings were evaluated. Included in the investigation were an electroplated alloy of black chrome and vanadium, electroplated black chrome, and chemically colored 316 stainless steel. Each of the coatings possessed good selective solar energy absorption properties at laboratory ambient temperature. Measured at a temperature of 700 K (800 F), the emittances of black chrome, black chrome vanadium, and colored stainless steel were 0.11, 0.61, and 0.15, respectively. Black chrome and black chrome vanadium did not degrade optically in the presence of high heat (811 K (1000 F)). Chemically colored stainless steel showed slight optical degradation when exposed to moderately high heat (616 K (650 F)0, but showed more severe degradation at exposure temperatures beyond this level. Each of the coatings showed good corrosion resistance to a salt spray environment.

Lowery, J. R.↗

The Langdon effect in laser plasmas: Absorption and conduction

A plasma heated by inverse bremsstrahlung absorption of laser light develops a non-Maxwellian electron distribution function, called the Langdon effect [A. B. Langdon, Phys. Rev. Lett. 44, 575 (1980)]. These non-Maxwellian distributions are sufficiently long-lived to impact the absorption processes itself as well as the transport of heat by electrons. The theory of the Langdon effect in a homogeneous plasma is reviewed to clarify some aspects of Langdon's derivation as well as to confirm that the widely used super-Gaussian approximation works fairly well to describe the shape of the distribution function and reduction of the absorption rate. The Langdon effect on thermal conduction in an inhomogeneous plasma is developed by considering perturbations in a homogeneous absorbing plasma, which develops a heat flux due to both temperature and density gradients. A practical theory of the heat flux is developed by fitting the results of Vlasov–Fokker–Planck simulations, which avoids several approximations that compromised the usefulness of past theoretical predictions, most critically, the effect of electron–electron collisions on the fluxes. The present fits parameterize the coefficients of the temperature gradient (thermal conductivity) and the density gradient for a plasma of any ionization state and for any laser intensity where the theory of the Langdon effect remains locally valid. It is expected that this generalized theory of heat flow in an absorbing plasma will improve the predictive capability of radiation-hydrodynamics simulations of laser-produced plasmas, especially those formed in inertial confinement fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved Heat-of-Fusion Energy Storage

Alkali metal/alkali-halide mixtures proposed for preventing solid buildup during energy recovery. When mixture melts (by absorption of heat of fusion), it forms two immiscible liquids. Salt-rich phase is heavier and has higher melting/recrysallization temperature; so during energy recovery salt crystallizes in this phase first. Since heat exchanger for energy recovery is in lighter metal-rich phase, solids do not form and there is no reduction of heat-recovery efficiency.

Chen, K. H.↗

Heating of solar coronal loops by resonant absorption of Alfven waves

Numerical calculations governing the efficiency of coronal loop heating by the resonant absorption of shear Alfven waves are reported. The loop structure is modeled by a class of axisymmetric force-free equilibria of a long straight cylinder, approximating a large aspect ratio loop. For a range of parameters characterizing the evolution of solar coronal loops, the absorption bandwidth falls in the frequency range of the photospheric motions due to granulation and p-modes. Resonant Alfven wave absorption is thus a viable mechanism for coronal loop heating.

Grossmann, William↗

Nonventing, Regenerable, Lightweight Heat Absorber

A lightweight, regenerable heat absorber (RHA), developed for rejecting metabolic heat from a space suit, may also be useful on Earth for short-term cooling of heavy protective garments. Unlike prior space-suit-cooling systems, a system that includes this RHA does not vent water. The closed system contains water reservoirs, tubes through which water is circulated to absorb heat, an evaporator, and an absorber/radiator. The radiator includes a solution of LiCl contained in a porous material in titanium tubes. The evaporator cools water that circulates through a liquid-cooled garment. Water vapor produced in the evaporator enters the radiator tubes where it is absorbed into the LiCl solution, releasing heat. Much of the heat of absorption is rejected to the environment via the radiator. After use, the RHA is regenerated by heating it to a temperature of 100 C for about 2 hours to drive the absorbed water back to the evaporator. A system including a prototype of the RHA was found to be capable of maintaining a temperature of 20 C while removing heat at a rate of 200 W for 6 hours.

Izenson, Michael G.↗

Calculations of Solar Shortwave Heating Rates due to Black Carbon and Ozone Absorption Using in Situ Measurements

Results for the solar heating rates in ambient air due to absorption by black-carbon (BC) containing particles and ozone are presented as calculated from airborne observations made in the tropical tropopause layer (TTL) in January-February 2006. The method uses airborne in situ observations of BC particles, ozone and actinic flux. Total BC mass is obtained along the flight track by summing the masses of individually detected BC particles in the range 90 to 600-nm volume-equivalent diameter, which includes most of the BC mass. Ozone mixing ratios and upwelling and partial downwelling solar actinic fluxes were measured concurrently with BC mass. Two estimates used for the BC wavelength-dependent absorption cross section yielded similar heating rates. For mean altitudes of 16.5, 17.5, and 18.5 km (0.5 km) in the tropics, average BC heating rates were near 0.0002 K/d. Observed BC coatings on individual particles approximately double derived BC heating rates. Ozone heating rates exceeded BC heating rates by approximately a factor of 100 on average and at least a factor of 4, suggesting that BC heating rates in this region are negligible in comparison.

Gao, R. S.↗

Modeling and Experiments on a Dedicated Outdoor Air System Using Liquid Desiccant Heat and Mass Exchangers

Liquid desiccants can provide efficient dehumidification but have yet to see widespread adoption. Most systems studied previously use natural gas-combustion to heat and regenerate the desiccant, and a central chiller plant or cooling tower for removing the heat of absorption. Here we present modeling and experimental results on a novel packaged air conditioner integrating liquid-desiccant heat and mass exchangers with a vapor compression cycle. The packaged system does not need cold or hot water from a central plant or cooling tower and is suitable for rooftop unit air conditioners. The system uses the evaporator to cool the liquid desiccant that is absorbing moisture from the air, and the condenser to heat the liquid desiccant to regenerate it. Efficiency is improved by reducing the load on the evaporator for a given supply-air dewpoint. This paper presents the measured dehumidification efficiency for a 10- ton packaged air conditioner, focusing on dehumidifying ventilation air. The paper also presents a numerical model to predict the outlet conditions and dehumidification efficiency, which we compare with the measured data.

air conditioning↗

Fuel cell on-site integrated energy system parametric analysis of a residential complex

The use of phosphoric acid fuel cell powerplant to provide all the electricity required by an 81-unit garden apartment complex is studied. Byproduct heat is recovered and provides some of the heat required by the complex. The onsite integrated energy system contains energy conversion equipment including combinations of compression and absorption chillers, heat pumps, electric resistance heaters, and thermal storage. The annual fuel requirement for several onsite integrated energy systems as well as the fuel cell breakeven cost for one specific system were calculated. It is found that electrical efficiency cannot be traded off against thermal efficiency without paying a penalty in system efficiency.

Simons, S. N.↗

Evaluation of Additively Manufactured Monolithic SiC and SiC Ceramic Matrix Composites for CSP- Fabrication and Testing of Receiver Design Feature Specimens in a Simulating Lab Test via Laser Heating

Critical to the creation of a multi-component SiC receiver design concept capable of meeting the SETO CST cost goal objectives of <$150/kWth is the optimal utilization of material for solar absorption and heat transfer to transport fluid. This is to maximize the solar-thermal efficiency in the techno-economic analysis of derived use case. As a first step in preparation of sub-component design for on-sun test evaluations we use different proposed SiC absorber element in a customized laser heat flux test to assess an effective heat transfer coefficient characteristic of the design. The test results are analyzed to extract the effective heat transfer coefficient, thus enable optimization of the geometry of receiver components for heat transfer, efficiency attributes and the thermo-structural management of the components. High intensity CO2 laser is used in combination with air flow through the test specimen to assess the effective heat transfer coefficient under heat flux conditions corresponding to high solar concentrations in the range of 1000-2000 suns.

14 SOLAR ENERGY↗

Optimal Design and Operation of Intensified Absorbers with 3D-Printed Packing for Solvent-Based CO 2 Capture

Many potential solvent-based carbon capture processes suffer from a high heat of absorption of CO 2 that adversely affects the thermodynamic driving force. While interstage coolers are often used for removing a portion of the generated heat by removing the solvent or a portion of the solvent from a stage and cooling and returning it back to the absorber, they can be placed only at discrete locations in the tower. This work investigates intensified absorbers with 3D-printed packing that includes an internal cooler and therefore can be potentially used for maximizing the operational efficiency of the absorbers for CO 2 capture. The intensified absorber is modeled by using a generic, first-principles, equation-oriented absorber column model. Since the placement of these intensified packings would cause a loss of area/volume used for mass transfer, optimization of the proposed intensified absorber is performed by optimally selecting the locations at which to place these devices and designing them such that the trade-off due to the addition of the heat removal area and the resulting loss in the mass transfer area is accounted for. Results show that optimally placed and designed intensified packings can lead to a significant increase in the capture efficiency of the process in comparison to a similar column with no internal cooling. It is also observed that by optimally placing and designing intensified packings, the lean solvent flow rate to the absorber can be decreased, and the CO 2 lean loading can be increased while still maintaining the same capture efficiency. These process changes can lead to a substantial reduction in the cost of capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrodynamic expansion and near-infrared absorption of x-ray heated aluminum plasmas

We use x-ray pulses from dense argon plasmas at the Z Machine (Sandia National Laboratories) to generate hypersonic aluminum plasmas akin to material ejecta during proposed planetary defense missions, fusion reactor wall excursions, and other high-energy density processes. Near-infrared absorption is used to diagnose the controlled expansion of the plasmas through cylindrical cavities following their generation from x-ray heating of solid aluminum 7075 alloy. The data are compared to multidimensional radiation hydrodynamics simulations utilizing the ALEGRA multiphysics code, accounting for the dynamics of radiation scattering, material phase change, plasma expansion, thermal re-irradiation, and interactions with the cavity and with the infrared beams. To allow for accurate simulation, density functional theory is used to apply the Hagen–Rubens relation for the far-infrared and is adjoined with a detailed configuration accounting model using the Propaceos code, producing opacities spanning 10 −1 –10 4 eV photon energy for aluminum 7075 alloy, and in comparison with pure aluminum. The model is found to agree with experimental data in the higher-fluence regime when the Hagen–Rubens relation is applied. The ejected material, which is observed to travel up to 55 km/s, is comprised of a strongly ionized, non-LTE plasma front at ∼10 eV temperature followed by a weakly ionized LTE gas at higher density. The present findings lend some confidence to the broad-range equation of state and infrared opacity models for weakly ionized aluminum plasmas while demonstrating an approach to their future refinement, with potential application to astrophysical plasmas and other extreme processes.

Adiabatic process↗

Polar thermospheric Joule heating, and redistribution of recombination energy in the upper mesosphere

Kellogg (1961), suggested that transport of atomic oxygen from the summer into the winter hemisphere and subsequent release of energy by three body recombination, O+O+N2 yields O2+N2+E, may contribute significantly to the so-called mesopause temperature anomaly. Earlier model calculations have shown that Kellogg's mechanism produces about a 10-percent increase in the temperature from summer to winter at 90 km. This process, however, is partly compensated by differential heating from absorption of UV radiation associated with dissociation of O2. In the auroral region of the thermosphere, there is a steady energy dissipation by Joule heating causing a redistribution and depletion of atomic oxygen due to wind-induced diffusion. With the removal of O, latent chemical energy normally released by three body recombination is also removed, and the result is that the temperature decreases by almost 2 percent near 90 km. Through dynamic feedback, this process reduces the depletion of atomic oxygen by about 25 percent and the temperature perturbation in the exosphere from 10 to 7 percent at polar latitudes. Under the influence of the internal dynamo interaction, the prevailing zonal circulation in the upper thermosphere changes direction when the redistribution of recombination energy is considered.

Mayr, H. G.↗

Simulation Studies of Electromagnetic Energy Absorption by Hydride Materials

This paper investigates the key parameters that contribute to electromagnetic (EM) energy absorption and heating of hydride materials which could be used to release hydrogen for use as a fuel. Our simulation study using COMSOL focuses on EM energy absorption and resulting temperature rise in a thin circular slab of hydride material using resonant dipole and loop antennas. Presented results delineate the effects of conductivity, relative permeability, antenna type and slab size on temperature rise when the distance and amount of RF power are kept fixed.

Brown, Michael A.↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Interstellar grains in elliptical galaxies

We consider the evolution and heating of dust embedded in the hot interstellar medium of isolated elliptical galaxies. We first construct a new set of galaxy models spanning a decade in luminosity which we use to study the evolution of dust as it is ejected by stellar sources, merges and flows with the interstellar gas, and is sputtered away due to the presence of the hot gas. We find that although grains can flow a considerable distance from the parent star in some cases before being sputtering away, the grain size distribution at a given location is accurately determined by assuming in situ sputtering of dust grains as they are ejected by the parent star. We find that dust heating is dominated by absorption of ambient starlight. Heating due to collisions with energetic electrons in the hot gas and absorption of thermal X-rays is smaller by orders of magnitude. We also find that for the largest galaxy considered (L(sub B) approximately 10 (exp 11) solar luminosity) the energy lost from the hot gas due to electronic collisions with the dust is about an order of magnitude less than that lost due to thermal emission in X-rays. The gas in smaller galaxies loses even less of its energy via heating of grains. In deriving this result, we find that the inclusion of grain sputtering is a crucial ingredient of the calculation. The presence of dust grains is therefore energetically unimportant for elliptical galaxy cooling flow models.

Tsai, John C.↗