Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Suppression of the Biermann Battery and Stabilization of the Thermomagnetic Instability in Laser Fusion Conditions

Magnetic field generated by the Biermann battery is thought to be one of the principal mechanisms behind the inhibition of heat flow in laser-plasma interactions, and is predicted to grow exponentially in some contexts due to the thermomagnetic instability [Tidman and Shanny, Phys. Fluids 17, 1207 (1974)]. In contrast to these predictions, however, here we have conducted Vlasov-Fokker-Planck simulations of magnetic field dynamics under a range of classically unstable laser-fusion conditions, and find field generation to be strongly suppressed, preventing magnetization of the transport, and stabilizing instability. By deriving new scaling laws, we show that this stabilization is a consequence of (i) heavy suppression of the Biermann battery under nonlocal conditions; (ii) rapid convection of magnetic field by the heat flow; and (iii) comparatively short field length scales. Our results indicate that classical models substantially overestimate the importance of magnetic fields generated by the Biermann battery, and the susceptibility of laser-fusion plasmas to the thermomagnetic instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental and modeling study of the effect of confinement on the thermal decomposition of organic materials

Simultaneous Thermal Analysis is widely used to study thermal decomposition of a variety of organic materials, and the choice of experimental conditions is very important to obtain reliable mass loss and heat flow curves. Here in this work we investigate the effect of confinement on the thermal decomposition of organic materials. As an example, we explore high-density polyethylene (HDPE) and one of its pyrolysis products, namely eicosane (C 20 H 42 ), through experiments and modeling in open crucibles and crucibles closed with a pierced lid. A new model is developed for evaporation and sublimation from open and pinhole thermal-analysis pans. It considers the kinetic resistance of evaporation at the liquid-vapor interface, inhibition of evaporation by buildup of vapor inside the pan, thermal expansion of vapor inside the pan, and diffusion of vapor from the pan. The model is validated using simultaneous heat-flow and mass-loss measurements of n-eicosane evaporation for various pinhole sizes, down to 50 µm. The importance of product evaporation inhibition for measuring polymer decomposition was demonstrated using HDPE. This study sheds light on the effect of confinement on the mass loss rate of organic materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transparent, High‐Charge Capacity Metal Mesh Electrode for Reversible Metal Electrodeposition Dynamic Windows with Dark‐State Transmission <0.1%

Abstract Dynamic windows allow user control over light and heat flow to save energy and maximize comfort. Reversible metal electrodeposition (RME) dynamic windows can uniquely tint to a color‐neutral privacy state (0.1% visible light transmission). The design parameters of transparent metal mesh counter electrodes for high‐contrast RME dynamic windows: high transparency, charge capacity and surface area with low haze, sheet resistance and cost are discussed, concluding that woven metal meshes meet these design parameters. Electroplated current is measured on an indium tin oxide electrode and two meshes with different wire spacings, showing the meshes’ cylindrical geometry enable them to draw more current per square area. The mesh material composition is analyzed to ensure cycling durability in a CuBi electrolyte by developing a transparent mesh with an inert core (stainless steel, SS), a thin Au coating, and a high charge‐capacity (1.5 C cm −2 ) CuBi outer coating. The study demonstrates that the films maintain a consistent Cu:Bi ratio and optical properties after 250 privacy cycles or 1500 cycles to 10% transmission, showing that the Cu and Bi coating is effective in keeping the films from becoming Cu rich with cycling. Finally, a 100 cm 2 device with excellent uniformity and color neutrality is demonstrated.

Yeang, Andrew L.↗

MnP Films with Desired Magnetic, Magnetocaloric, and Thermoelectric Properties for a Perspective Magneto-Thermo-Electric Cooling Device

A new magneto-thermo-electric cooling device (MTECD) comprising a central magnetocaloric (MC) material (e.g., Gd) sandwiched by two thermoelectric (TE) materials (e.g., MnP) is proposed. The presence of the TE materials in the MTECD guides the heat flow direction and enhances heat pulsation. Here in this case, the usage of a ferromagnetic TE material that combines large TE with small MC properties within a similar temperature region can enhance the magnetic flux density and heat exchange efficiency. Herein, it is shown that MnP nanorod-structured films with desired magnetic, MC, and TE properties are very promising for use in MTECDs. The films are grown on Si substrates at 300, 400, and 500 °C using molecular beam epitaxy. The 400 °C sample shows a desired TE and MC combination. A large power factor of 24.06 μW m -1 K -2 is achieved at room temperature. In this temperature region, the film exhibits a small MC effect (-ΔS M ≈0.64 J kg -1 K and ΔT ad ≈0.3 K at μ 0 H = 2 T) but ferromagnetism that gives rise to the enhanced MC effect of the central MC material. These properties can enable the MTECD to operate at high frequency.

36 MATERIALS SCIENCE↗

Hot-spot model for inertial confinement fusion implosions with an applied magnetic field

Imposing a magnetic field on inertial confinement fusion implosions magnetizes the electrons in the compressed fuel; this suppresses thermal losses, which increases temperature and fusion yield. Indirect-drive experiments at the National Ignition Facility with 12 and 26 T applied magnetic fields demonstrate up to 40% increase in temperature, 3× increase in fusion yield, and indicate that magnetization alters the radial temperature profile [Moody et al., Phys. Rev. Lett. 129, 195002 (2022); Lahmann et al., APS DPP (2022)]. In this work, we develop a semi-analytic hot-spot model, which accounts for the two-dimensional (2D) Braginskii anisotropic heat flow due to an applied axial magnetic field. First, we show that hot-spot magnetization alters the radial temperature profile, increasing the central peakedness, which is most pronounced for moderately magnetized implosions (with 8–14 T applied field), compared to both unmagnetized (with no applied field) and highly magnetized (with 26 T or higher applied field) implosions. This model explains the trend in the experimental data, which finds a similarly altered temperature profile in the 12 T experiment. Next, we derive the hot-spot model for gas-filled (Symcap) implosions, accounting for the effects of magnetization on the thermal conduction and in changing the radial temperature (and density) profiles. Using this model, we compute predicted central temperature amplification and yield enhancement scaling with the applied magnetic field. The central temperature fits the experimental data accurately, and the discrepancy in the yield suggests a systematic (independent of applied field) degradation, such as mix, and additional degradation in the reference unmagnetized shot, such as reduced laser drive, increased implosion asymmetry, or the magnetic field suppressing ablator mixing into the hot-spot.

Alpha particles↗

Circumferential flow foam heat exchanger

A heat exchanger is disclosed that includes a cold heat exchange zone including a foam material having an annular geometry and having fluid distribution and collection slots configured to distribute a cooling fluid circumferentially through the foam material.

Youchison, Dennis L.↗

Performance of Microreactor Test Article with Embedded Sensors During Testing in The Single Primary Heat Extraction and Removal Emulator

The nuclear industry is pursuing microreactors that can be factory assembled and deployed to remote regions for reliable power generation. One class of microreactors uses a monolithic metal core block coupled to heat pipes that use passive heat flow, increasing the surface area for heat transfer without requiring active coolant flow through the reactor core. Additional experimental testing is required to understand the heat rejection limitations of heat pipes and thermal stresses in the monolithic core block due to significant temperature gradients. This report describes the initial characterization and testing of a stainless-steel test article that was fabricated with embedded sensors to measure heat pipe performance limits, as well as spatially distributed temperatures and strains during electrically heated thermal testing to simulate nuclear heating. The electrically heated testing was performed in the Single Primary Heat Extraction and Removal Emulator facility located at Idaho National Laboratory. The ultimate goals of this work are to (1) accurately monitor temperature and strain distributions that result from differential thermal expansion in the test articles and (2) quantify the heat rejection limits of heat pipes as a function of operating temperature and working fluid during steady-state and transient operations. Initial tests focused on the feasibility of using advanced fiber-optic sensors and other sensor technologies to improve the understanding of temperature and strain distributions within the electrically heated experiments. However, these sensing capabilities could benefit the broader microreactor community if the sensors could be used to monitor component and system health during nuclear operations to inform a limited number of microreactor operators, ultimately reducing operation and maintenance costs and moving toward semiautonomous operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Magnetized directly-driven ICF capsules: increased instability growth from non-uniform laser drive

Simulations anticipate increased perturbation growth from non-uniform laser heating for magnetized direct-drive implosions. At the capsule pole, where the magnetic field is normal to the ablator surface, the field remains in the conduction zone and suppresses non-radial thermal conduction; in unmagnetized implosions this non-radial heat-flow is crucial in mitigating laser heating imbalances. Single-mode simulations show the magnetic field particularly amplifying short wavelength perturbations, whose behavior is dominated by thermal conduction. The most unstable wavelength can also become shorter. 3D multi-mode simulations of the capsule pole reinforce these findings, with increased perturbation growth anticipated across a wide range of scales. Finally, the results indicate that high-gain spherical direct-drive implosions require greater constraints on the laser heating uniformity when magnetized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetocaloric refrigerator

The invention is for an apparatus and method for a refrigerator and a heat pump based on the magnetocaloric effect (MCE) offering a simpler, lighter, robust, more compact, environmentally compatible, and energy efficient alternative to traditional vapor-compression devices. The subject magnetocaloric apparatus alternately exposes portions of an MCE material to strong and weak magnetic field while coordinating the heat flow between the exposed portions by heat bridges to move the heat up the thermal gradient. The invention may be practiced with multiple MCE material portions or segments to attain large differences in temperature. Key applications include thermal management of electronics, as well as industrial and home refrigeration, heating, and air conditioning. The invention offers a simpler, lighter, compact, and robust apparatus compared to magnetocaloric devices of prior art. Furthermore, the invention may be run in reverse as a thermodynamic engine, receiving low-level heat and producing mechanical energy.

Vetrovec, Jan↗

A Finite Element Method for Compressible and Turbulent Multiphase Flow Instabilities with Heat Transfer

We present a new finite element framework for modeling compressible, turbulent multiphase flows with heat transfer. For two-fluid systems with a free surface, the Volume of Fluid (VOF) method is implemented without the need for interface reconstruction, while turbulence is resolved using a dynamic Vreman large eddy simulation (LES) model. Unlike most two-phase VOF studies, which neglect heat transfer, the present approach incorporates energy transport equations within the VOF formulation to account for heat exchange, an effect particularly important in turbulent flows. Conjugate heat transfer is often challenging in finite volume methods, which require explicit specification of heat fluxes at the solid–fluid interface, limiting accuracy and predictive capability. By contrast, the finite element formulation does not require heat flux inputs, allowing more accurate and robust simulation of heat transfer between solids and fluids. The method is demonstrated through three representative cases. First, a two-fluid instability with a single-mode perturbation is simulated and validated against analytical growth rates. Second, conjugate heat transfer is examined in a high-temperature flow over a cold metal cylinder, with validation performed both quantitatively—via pressure coefficient comparisons with experimental data—and qualitatively using vector field topology. Finally, compressible spray injection and breakup are modeled, demonstrating the ability of the framework to capture interfacial dynamics and atomization under turbulent, high-speed conditions. In the compressible spray injection and breakup case, the results indicate that the finite element formulation achieved higher predictive accuracy and robustness than the finite-volume method. With the same mesh resolution, the FEM reduced the root mean square error (RMSE) and mean absolute percentage error (MAPE) from 6.96 mm and 26.0% (for the FVM) to 4.85 mm and 12.7%, respectively, demonstrating improved accuracy and robustness in capturing interfacial dynamics and heat transfer. The study also introduced vector field topology to visualize and interpret coherent flow structures and instabilities, offering insights beyond conventional scalar-field analyses.

97 MATHEMATICS AND COMPUTING↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗