Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guide tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubes

Electrons accelerated in the nonlinear regime in a laser wakefield accelerator experience transverse oscillations inside the plasma cavity, giving rise to ultra-short pulsed x-rays, also called the betatron radiation. We show that the fluence of x-ray can be enhanced by more than one order of magnitude when the laser is guided by a 10 mm long capillary tube instead of interacting with a 2 mm gas jet. X-rays with a synchrotron-like spectrum and associated critical energy {approx}5 keV, with a peak brightness of {approx}1x10{sup 21} ph/s/mm{sup 2}/mrad{sup 2}/0.1%BW, were achieved by employing 16 TW laser pulses.

43 PARTICLE ACCELERATORS↗

CIRSE Standards of Practice Guidelines on Gastrostomy

PurposeSurgical Gastrostomy has been around since the 19th century but in 1980 the first successful percutaneous endoscopic gastrostomy was reported. A year later the first successful percutaneous gastrostomy was performed using fluoroscopic guidance. The technique for percutaneous insertion and the equipment used has been refined since then and it is now considered the gold standard for gastrostomy insertion. Here we present guidelines for image-guided enteral feeding tubes in adults.Material and MethodWe performed a review and analysis of the scientific literature, other national and international guidelines and expert opinion.ResultsStudies have shown fluoroscopic techniques have consistently higher success rates with lower rates of major complications than endoscopic techniques. However, the Achilles' heel of many fluoroscopic techniques is the requirement for smaller gastrostomy tube sizes resulting in them being more prone to blockages and thus requiring further intervention.ConclusionRadiological feeding tube insertion is a safe and effective procedure. Success rates are higher, and complication rates lower than PEG or surgical gastrostomy tube placement and innovative techniques for gastric and jejunal access mean that there are very few cases in which RIG is not possible. The principal weakness of radiologically inserted gastrostomies is the limitiation on tube size which leads to a higher rate of tube blockage. Per-oral image-guided gastrostomies have to an extent addressed this but have not been popularised. Currently many centres still consider endoscopic gastrostomies as the first line unless patients are too unwell to undergo this procedure or previous attempts have failed, in which case radioloically inserted gastrostomies are the technique of choice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57-93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 {+-} 13 (SD) min (range 24-78). The average follow-up time interval was 103 days (range 7-812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical modeling of multi-GeV laser wakefield electron acceleration inside a dielectric capillary tube

Numerical modeling of laser wakefield electron acceleration inside a gas filled dielectric capillary tube is presented. Guiding of a short pulse laser inside a dielectric capillary tube over a long distance (∼1 m) and acceleration of an externally injected electron bunch to ultra-relativistic energies (∼5-10 GeV) are demonstrated in the quasi-linear regime of laser wakefield acceleration. Two dimensional axisymmetric simulations were performed with the code WAKE-EP (Extended Performances), which allows computationally efficient simulations of such long scale plasma. The code is an upgrade of the quasi-static particle code, WAKE [P. Mora and T. M. Antonsen, Jr., Phys. Plasmas 4, 217 (1997)], to simulate the acceleration of an externally injected electron bunch (including beam loading effect) and propagation of the laser beam inside a dielectric capillary. The influence of the transverse electric field of the plasma wake on the radial loss of the accelerated electrons to the dielectric wall is investigated. The stable acceleration of electrons to multi-GeV energy with a non-resonant laser pulse with a large spot-size is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Particle charge spectrometer

An airflow through a tube is used to guide a charged particle through the tube. A detector may be used to detect charge passing through the tube on the particle. The movement of the particle through the tube may be used to both detect its charge and size.

Fuerstenau, Stephen D.↗

Performance and Commissioning of the BigBite Timing Hodoscope for Nucleon Form Factor Measurements at Jefferson Lab

The BigBite Timing Hodoscope detector is the primary subject of this thesis. The Super BigBite Spectrometer is a Jefferson Lab Hall A Collaboration project that has and will continue to measure nucleon electromagnetic form factors. This spectrometer includes the Timing Hodoscope which provides high resolution particle timing data for scattered electrons in the electron arm of BigBite. The Timing Hodoscope utilizes 90, 25 × 25 × 600 mm3 scintillator bars stacked on top of each other to form a single detector plane, and these bars are connected to 180 photo-multiplier tubes via light guides. Particles collide with the scintillating material creating a shower of optical photons and these particle events in the bars are collected to generate signals that are readout by the data acquisition (DAQ) electronics. NINO ASIC amplifier-discriminator cards output signals from the photo-multiplier tubes into analogue and logic signals, which are sent to analogue-to-digital (ADC) and time-to-digital (TDC) converter data acquisition readout modules. This data is then used for analysis of the detector. The focus of this thesis is the construction, commissioning, calibration, and performance of the BigBite Timing Hodoscope before and during the first of five nucleon electromagnetic form factor experiments at Jefferson Lab Hall A. Before the neutron magnetic form factor, G n M, experiment, cosmic ray data was collected during commissioning to confirm proper operation of the Timing Hodoscope electronics by observing the ADC and TDC data. Commissioning studies for charge normalization, gain matching, and other ADC and TDC detector data variables were performed before moving the detector into Hall A. Following installation in Hall A, several calibration studies were implemented to fine-tune the detector in preparation for use in the experiment. The calibration studies included analysis of timing cuts, TDC alignment, the time-walk effect, time difference offsets, and scintillator velocity corrections. Once the Timing Hodoscope was well-calibrated, data-taking during the experiment commenced and the beam-on-target data was used to characterize the Timing Hodoscope performance during the G n M experiment run-time. The performance analysis included studies observing energy deposit, cluster size, rates, accidentals, pile-up, tracking efficiency, position resolution, and time resolution. After application of physics cuts to ensure a data set comprised of particle tracks corresponding to elastic electrons, which is the main data of interest for measurement of G n M, the Timing Hodoscope is shown on average across all kinematic settings to have a >98% tracking efficiency, a position resolution of 4-6 cm in the non-dispersive plane and 1.5-2 cm in the dispersive plane, and a time resolution of 500-750 ps. These performance results are compared to a GEANT4 based performance simulation of the BigBite Timing Hodoscope for reference, showing to what degree the measured performance values match those taken from the simulation.

Marinaro, Ralph↗

Ultrasonic guided waves in eccentric annular pipes

This paper studies the feasibility of using ultrasonic guided waves to rapidly inspect tubes and pipes for possible eccentricity. While guided waves are well established in the long range inspection of structures such as pipes and plates, studies for more complex cross sections are limited and analytical solutions are often difficult to obtain. Recent developments have made the Semi Analytical Finite Element (SAFE) method widely accessible for researchers to study guided wave properties in complex structures. Here the SAFE method is used to study the effect of eccentricity on the modal structures and velocities of lower order guided wave modes in thin pipes of diameters typically of interest to the industry. Results are validated using experiments. The paper demonstrates that even a small eccentricity in the pipe can strongly affect guided wave mode structures and velocities and hence shows potential for pipe eccentricity inspection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multistage depressed collector conceptual design for thin magnetically confined electron beams

The requirement of higher efficiency in high power microwave devices, such as traveling wave tubes and gyrotrons, guides scientific research to more advanced types of collector systems. First, a conceptual design approach of a multistage depressed collector for a sheet electron beam confined by a magnetic field is presented. The sorting of the electron trajectories, according to their initial kinetic energy, is based on the E × B drift concept. The optimization of the geometrical parameters is based on the analytical equations under several general assumptions. The analysis predicts very high levels of efficiency. Then, a design approach for the application of this type of collector to a gyrotron cylindrical hollow electron beam is also presented with very high levels of efficiency more than 80%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of electron acceleration and x-ray radiation as a function of plasma density in capillary-guided laser wakefield accelerators

Laser wakefield electron acceleration in the blow-out regime and the associated betatron X-ray radiation were investigated experimentally as a function of the plasma density in a configuration where the laser is guided. Dielectric capillary tubes were employed to assist the laser keeping self-focused over a long distance by collecting the laser energy around its central focal spot. With a 40 fs, 16 TW pulsed laser, electron bunches with tens of pC charge were measured to be accelerated to an energy up to 300 MeV, accompanied by X-ray emission with a peak brightness of the order of 10{sup 21} ph/s/mm{sup 2}/mrad{sup 2}/0.1%BW. Electron trapping and acceleration were studied using the emitted X-ray beam distribution to map the acceleration process; the number of betatron oscillations performed by the electrons was inferred from the correlation between measured X-ray fluence and beam charge. A study of the stability of electron and X-ray generation suggests that the fluctuation of X-ray emission can be reduced by stabilizing the beam charge. The experimental results are in good agreement with 3D particle-in-cell (PIC) simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EVIDENCE FOR SHEET-LIKE ELEMENTARY STRUCTURES IN THE SUN'S ATMOSPHERE?

Narrow, thread-like structures in the Sun's chromosphere are currently understood to be plasma guided along narrow tubes of magnetic flux. We report on 1 s cadence imaging spectroscopic measurements of the H{alpha} line with the IBIS Fabry-Perot instrument at the Dunn Solar Telescope, obtained +0.11 nm from line center. Rapid changes grossly exceeding the Alfven speed are commonly seen along the full extent of many chromospheric threads. We argue that only an optical superposition effect can reasonably explain the data, analogous to striations of curtains blowing in the wind. Other explanations appear to require significant contrivances to avoid contradicting various aspects of the data. We infer that the absorbing plasma exists in two-dimensional sheet-like structures within the three-dimensional magnetofluid, related perhaps to magnetic tangential discontinuities. This interpretation demands a re-evaluation of basic assumptions about low-{beta} solar plasmas, as advocated by Parker, with broader implications in astrophysics and plasma physics. Diverse, high-cadence observations are needed to further define the relationship between magnetic field and thermal fine structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Laboratory Testing of the Temperature Sensor Qualification Device

The Temperature sensor Qualification Device (TQD) has been developed and tested under laboratory conditions to evaluate its thermal performance and the reliability of its retractable sensor system. The TQD is designed to provide an isothermal environment for temperature sensors in both test and reference zones during irradiation experiments. Initial testing revealed minimal radial and azimuthal temperature variations but identified a significant axial gradient. To address this, design modifications were implemented, including enhanced insulation and the addition of a small heater at the device's top. These changes are expected to produce a more uniform axial temperature profile, though further testing is recommended prior to irradiation. The retractable sensor mechanism was rigorously tested, achieving 1,350 cycles at room temperature and 332 cycles at 400°C before failure. The primary failure mechanism was the thermocouple becoming stuck in the wire guide or capillary tube. Based on these results, design improvements were proposed, such as incorporating a load cell for force monitoring and a stepper motor for precise sensor positioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-temperature ceramics for automobile gas turbines

The employment of the high operational temperatures makes it necessary to use, for the construction of the turbines, ceramic materials such as silicon nitride or silicon carbide. Investigations concerning the development of turbine components made of such materials are conducted by a German automobile manufacturer and the ceramics industry. The current status of these investigations is reviewed. Flame tubes and guide-vane rings have successfully passed tests lasting 20 hours. Prototype turbine wheels have withstood the effects of peripheral speeds of 450 m/s. They also showed resistance to thermal shocks which were as high as 6-0 K/s.

Walzer, P.↗

A reaction plane detector for PHENIX at RHIC

A plastic scintillator paddle detector with embedded fiber light guides and photomultiplier tube readout, referred to as the Reaction Plane Detector (RXNP), was designed and installed in the PHENIX experiment prior to the 2007 run of the Relativistic Heavy Ion Collider (RHIC). The RXNP's design is optimized to accurately measure the reaction plane (RP) angle of heavy-ion collisions, where, for mid-central {radical}s{sub NN} = 200 GeV Au+Au collisions, it achieved a 2nd harmonic RP resolution of {approx}0.75, which is a factor of {approx}2 greater than PHENIX's previous capabilities. This improvement was accomplished by locating the RXNP in the central region of the PHENIX experiment, where, due to its large coverage in pseudorapidity (1.0 < |{eta}| < 2.8) and {phi}(2{pi}), it is exposed to the high particle multiplicities needed for an accurate RP measurement. To enhance the observed signal, a 2-cm Pb converter is located between the nominal collision region and the scintillator paddles, allowing neutral particles produced in the heavy-ion collisions to contribute to the signal through conversion electrons. This paper discusses the design, operation and performance of the RXNP during the 2007 RHIC run.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bessel Tube to Capture Lunar Volatiles

Current arts to create linear motion or acceleration of fine particles and molecules into devices such as mass spectrometers and vacuum pumps rely on the pressure difference created by a pinhole or mechanical processes. However, in an environment of vacuum, these approaches do not create such a pressure differential to drive and move fine particles and molecules. In some cases, electrostatic or magnetic processes may work to create the desired motion. A cylindrical harmonic of electric field, which is widely used in electron accelerators, offers a unique capability to capture and induce a linear motion of molecules and particles when electrically charged. Generally, lunar volatiles are electrostatically charged. The idea to capture and collect the lunar volatiles by creating a drift axis of motion using a cylindrical harmonic field has led to the development of a device concept, called a Bessel Tube. The Bessel Tube concept ingests fine particles, gaseous atoms, and gaseous molecules and guides them along an extraction tube for collection, separation, and analysis. The Bessel Tube concept for lunar volatile collection is discussed.

Bessel Tube↗

Atom Skimmers and Atom Lasers Utilizing Them

Atom skimmers are devices that act as low-pass velocity filters for atoms in thermal atomic beams. An atom skimmer operating in conjunction with a suitable thermal atomic-beam source (e.g., an oven in which cesium is heated) can serve as a source of slow atoms for a magneto-optical trap or other apparatus in an atomic-physics experiment. Phenomena that are studied in such apparatuses include Bose-Einstein condensation of atomic gases, spectra of trapped atoms, and collisions of slowly moving atoms. An atom skimmer includes a curved, low-thermal-conduction tube that leads from the outlet of a thermal atomic-beam source to the inlet of a magneto-optical trap or other device in which the selected low-velocity atoms are to be used. Permanent rare-earth magnets are placed around the tube in a yoke of high-magnetic-permeability material to establish a quadrupole or octupole magnetic field leading from the source to the trap. The atoms are attracted to the locus of minimum magnetic-field intensity in the middle of the tube, and the gradient of the magnetic field provides centripetal force that guides the atoms around the curve along the axis of the tube. The threshold velocity for guiding is dictated by the gradient of the magnetic field and the radius of curvature of the tube. Atoms moving at lesser velocities are successfully guided; faster atoms strike the tube wall and are lost from the beam.

Hulet, Randall↗

Feasibility of Lead Fast Reactor Heat Exchanger Tube Online Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, wedges vs. direct application of piezoelectric sensors, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

Progress Toward Molten Salt Reactor Heat Exchanger On-Line Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

WE-AB-BRA-10: Assessment of Fiber Bragg Grating (FBG)-Based Sensing for Real-Time Needle Tracking During MR-Guided Brachytherapy

Purpose: This study assesses the potential of Fiber Bragg Grating (FBG)-based sensing for real-time needle (including catheter or tube) tracking during MR-guided HDR brachytherapy. Methods: The proposed FBG-based sensing tracking approach involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. When the stylet is inserted inside the lumen of the needle, the FBG sensing system can measure the needle’s deflection. For localization of the needle in physical space, the position and orientation of the stylet base are mandatory. For this purpose, we propose to fix the stylet base and determine its position and orientation using a MR-based calibration as follows. First, the deflection of a needle inserted in a phantom in two different configurations is measured during simultaneous MR-imaging. Then, after segmentation of the needle shapes on the MR-images, the position and orientation of the stylet base is determined using a rigid registration of the needle shapes on both MR and FBG-based measurements. The calibration method was assessed by measuring the deflection of a needle in a prostate phantom in five different configurations using FBG-based sensing during simultaneous MR-imaging. Any two needle shapes were employed for the calibration step and the proposed FGB-tracking approach was subsequently evaluated on the other three needles configurations. The tracking accuracy was evaluated by computing the Euclidian distance between the 3D FBG vs. MR-based measurements. Results: Over all needle shapes tested, the average(standard deviation) Euclidian distance between the FBG and MR-based measurements was 0.79mm(0.37mm). The update rate and latency of the FBG-based measurements were 100ms and 300ms respectively. Conclusion: The proposed FBG-based protocol can measure the needle position with an accuracy, precision, update rate and latency eligible for accurate needle steering during MR-guided HDR brachytherapy. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.

61 RADIATION PROTECTION AND DOSIMETRY↗