Beyond MAP: A guide to dimensions of rainfall variability for tropical ecology
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Purpose: To characterize radiation therapy patient breathing patterns based on measured external surrogate information. Methods: Breathing surrogate data were collected during 4DCT from a cohort of 50 patients including 28 patients with lung cancer and 22 patients without lung cancer. A spirometer and an abdominal pneumatic bellows were used as the surrogates. The relationship between these measurements was assumed to be linear within a small phase difference. The signals were correlated and drift corrected using a previously published method to convert the signal into tidal volume. The airflow was calculated with a first order time derivative of the tidal volume using a window centered on the point of interest and with a window length equal to the CT gantry rotation period. The airflow was compared against the tidal volume to create ellipsoidal patterns that were binned into 25 ml × 25 ml/s bins to determine the relative amount of time spent in each bin. To calculate the variability of the maximum inhalation tidal volume within a free-breathing scan timeframe, a metric based on percentile volume ratios was defined. The free breathing variability metric (κ) was defined as the ratio between extreme inhalation tidal volumes (defined as >93 tidal volume percentile of the measured tidal volume) and normal inhalation tidal volume (defined as >80 tidal volume percentile of the measured tidal volume). Results: There were three observed types of volume-flow curves, labeled Types 1, 2, and 3. Type 1 patients spent a greater duration of time during exhalation withκ = 1.37 ± 0.11. Type 2 patients had equal time duration spent during inhalation and exhalation with κ = 1.28 ± 0.09. The differences between the mean peak exhalation to peak inhalation tidal volume, breathing period, and the 85th tidal volume percentile for Type 1 and Type 2 patients were statistically significant at the 2% significance level. The difference between κ and the 98th tidal volume percentile for Type 1 and Type 2 patients was found to be statistically significant at the 1% significance level. Three patients did not display a breathing stability curve that could be classified as Type 1 or Type 2 due to chaotic breathing patterns. These patients were classified as Type 3 patients. Conclusions: Based on an observed volume-flow curve pattern, the cohort of 50 patients was divided into three categories called Type 1, Type 2, and Type 3. There were statistically significant differences in breathing characteristics between Type 1 and Type 2 patients. The use of volume-flow curves to classify patients has been demonstrated as a physiological characterization metric that has the potential to optimize gating windows in radiation therapy.
In prokaryotes, RNA derived from type I and type III CRISPR loci direct large ribonucleoprotein complexes to destroy invading bacteriophage and plasmids. In Escherichia coli, this 405-kilodalton complex is called Cascade. We report the crystal structure of Cascade bound to a single-stranded DNA (ssDNA) target at a resolution of 3.03 angstroms. The structure reveals that the CRISPR RNA and target strands do not form a double helix but instead adopt an underwound ribbon-like structure. This noncanonical structure is facilitated by rotation of every sixth nucleotide out of the RNA-DNA hybrid and is stabilized by the highly interlocked organization of protein subunits. These studies provide insight into both the assembly and the activity of this complex and suggest a mechanism to enforce fidelity of target binding.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
MFiX (Multiphase Flow with Interphase eXchanges) is an open-source multiphase flow solver developed at the National Energy Technology Laboratory. Within the code, users have access to a single phase or interpenetrating continua-based multiphase two-fluid model (TFM), a discrete element model (DEM), and a particle-in-cell model (PIC). TFM, DEM, and PIC can all be used to create multiphase simulations that include hydrodynamics, chemical reactions, and heat transfer.
Abstract not provided.
Abstract The purpose of the current study is to find out the heat transfer and pressure drop phenomena of the cooling channel with dimples and guide vane and compare the results with the no guide vane dimpled cooling channel. The first leg of the cooling channel is 490 mm, and the second leg is 460 mm. The two legs relate to the 180 deg turn region. The guide vane was inserted at the bend region of the dimpled cooling channel. The study was conducted with two different guide vanes geometry at two different orientations, i.e., U-guide vane with protrusion and depression orientation and curve-guide vane with protrusion and depression orientations both experimentally and numerically. The numerical study was performed with the large eddy simulation method. The result shows that for both stationary and rotational motion, the U-guide vane with depression experiences the highest thermal performance. The friction factor is comparatively higher for curve-guide vane with protrusion under stationary motion. However, under rotation, the curve-protrusion guide encounters the highest friction factor, which is higher compared to the no guide vane cooling channel.
This guide highlights operations and maintenance programs targeting energy and water efficiency that are estimated to save 5% to 20% on energy bills without a significant capital investment. The purpose of this guide is to provide you, the Operations and Maintenance (O&M)/Energy manager and practitioner, with useful information about O&M management, technologies, energy and water efficiency, and cost-reduction approaches. To make this guide useful and to reflect your needs and concerns, the authors met with O&M and Energy managers via Federal Energy Management Program (FEMP) workshops. In addition, the authors conducted extensive literature searches and contacted numerous vendors and industry experts. The information and case studies that appear in this guide resulted from these activities. It needs to be stated at the outset that this guide is designed to provide information on effective O&M as it applies to systems and equipment typically found at Federal facilities. This guide is not designed to provide the reader with step-by-step procedures for performing O&M on any specific piece of equipment. Rather, this guide first directs the user to the manufacturer's specifications and recommendations. In no way should the recommendations in this guide be used in place of manufacturer's recommendations. The recommendations in this guide are designed to supplement those of the manufacturer, or, as is all too often the case, provide guidance for systems and equipment for which all technical documentation has been lost. As a rule, this guide will first defer to the manufacturer's recommendations on equipment operation and maintenance.
An integral part of the National Institute of Standards and Technology Center for Neutron Research (NCNR) expansion project is the addition of five cold neutron guide tubes serving multiple experimental stations in an expanded guide hall. The guides have curved-straight arrangements in the horizontal plane, employing horizontally or vertically defocusing and focusing sections in some cases to improve transmission efficiency or for beam reshaping. The horizontally curved sections eliminate direct lines of sight between the source and the experimental stations, and the outer (concave) surfaces generally have higher critical angles than the inner (convex) surfaces. These features result in well-filtered cold neutron beams with no intensity losses at shorter wavelengths with respect to curved guides having the higher critical angle coatings on both surfaces. For all guides the critical angle of the outer coating of the curved section is selected to achieve a desirable characteristic wavelength, consistent with the instrument requirements. On guides where the scattering-plane beam divergence must be strictly limited, the inner radial coatings of the curved sections and the side coatings and lengths of the final straight sections are chosen to produce the desired beam divergence while the outer radial coating is selected so as to obtain a spatial-angular uniformity of the transmitted beam that is not achievable using a curved guide alone. The long-wavelength transmission of such guides tends to exceed that of equivalent straight guides using crystal filters.
The Light Water Reactor Sustainability Program began to evaluate technologies that could be used to perform online monitoring of piping and other secondary system structural components in commercial NPPs. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real-time measurements, rather than at a pre-determined inspection interval. This transition to condition-based, risk informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for most nuclear power generation costs. This report describes the current state of research related to ultrasonic guided wave testing and its application to defect detection in commercial nuclear power plants. The report analyses the applicability of the guided wave technology to secondary piping systems and also study the potential for expanding the range of guided wave technology to include bent piping and other piping components. The ultrasonic guided waves can inspect long stretches of straight piping, however more complex geometries such as elbows, welds, and tees are causing spurious reflections and coherent noise which significantly decrease the sensitivity of the technique. The report analyses two approaches to suppression of coherent noise in guided wave systems: advanced signal processing and pattern recognition based on independent component analysis and blind source separation and hardware-based technique of piezoelectric paint which can be used to facilitate the propagation of mechanical stress waves through piping. It is demonstrated on simulated guided wave data that the independent component analysis is capable of separating different coherent noise components and segregating them from useful signal. The piezoelectric paint approach seem to be a viable alternative to the signal processing methods, however it requires significantly more complicated logistics and initial financial outlay. The future efforts will be concentrated on applying the independent component analysis to real-world guided wave data recorded by the guided wave monitoring system installed on the shell of the low-pressure feedwater heater 13A at Exelon Corporation’s Braidwood Nuclear Generating Station. Also, the joint EPRI-INL research efforts will focus on experimental evaluation of piezoelectric paint as a technique to extend the range of guided wave technology.
PurposeThe purpose of this study was to determine the feasibility, safety, and early effectiveness of percutaneous image-guided ablation as second-line treatment for symptomatic soft-tissue vascular anomalies (VA).Materials and MethodsAn IRB-approved retrospective review was undertaken of all patients who underwent percutaneous image-guided ablation as second-line therapy for treatment of symptomatic soft-tissue VA during the period from 1/1/2008 to 5/20/2014. US/CT- or MRI-guided and monitored cryoablation or MRI-guided and monitored laser ablation was performed. Clinical follow-up began at one-month post-ablation.ResultsEight patients with nine torso or lower extremity VA were treated with US/CT (N = 4) or MRI-guided (N = 2) cryoablation or MRI-guided laser ablation (N = 5) for moderate to severe pain (N = 7) or diffuse bleeding secondary to hemangioma–thrombocytopenia syndrome (N = 1). The median maximal diameter was 9.0 cm (6.5–11.1 cm) and 2.5 cm (2.3–5.3 cm) for VA undergoing cryoablation and laser ablation, respectively. Seven VA were ablated in one session, one VA initially treated with MRI-guided cryoablation for severe pain was re-treated with MRI-guided laser ablation due to persistent moderate pain, and one VA was treated in a planned two-stage session due to large VA size. At an average follow-up of 19.8 months (range 2–62 months), 7 of 7 patients with painful VA reported symptomatic pain relief. There was no recurrence of bleeding at five-year post-ablation in the patient with hemangioma–thrombocytopenia syndrome. There were two minor complications and no major complications.ConclusionImage-guided percutaneous ablation is a feasible, safe, and effective second-line treatment option for symptomatic VA.
The design of a replacement cold neutron guide system for the High Flux Isotope Reactor (HFIR) is presented. The proposed six-channel design uses the latest technologies and is optimally designed to account for operational and site constraints. These include the design of the cold source and the beam tube, the size and shape of the penetrations in the reactor confinement boundary, and the shape and orientation of the guide hall. The existing user instruments are a macromolecular diffractometer (IMAGINE), an IMAGING station, two small-angle neutron scattering (SANS) instruments (Bio-SANS and GP-SANS), and a cold triple-axis spectrometer (C-TAX). These instruments will all be reinstalled at end-of-guide positions with improved performance, and a position for a new high-performance neutron spin echo instrument will be created. The proposed guide design requires an extension to the guide hall toward the south. The calculated flux gain for a typical experiment is between a factor of 1.3 and 3 for all instruments, with the exception of the C-TAX instrument, which stands to gain a factor of >30 in flux at the sample. The new guide system will also offer additional performance gains, such as an increase in Q-range on Bio-SANS. The stated performance gains do not take into account any potential performance gains resulting from renewal and realignment of the guide system. The design of the guide system in the common sections up to about 25 m from the source is considered to be complete and ready for engineering design, while the designs of the instrument-specific guides are in some cases still a work in progress. The present report describes the current status of those designs.
There are many challenges associated with the inspections of double-shell storage tanks containing radioactive waste, including limited space for accessibility and maneuverability, environments with high radiation, temperature and toxicity, and unknown physical conditions. Contents of the tank and limited space may prevent access of scanning devices that employ conventional NDE techniques such as ultrasonics, eddy current, or magnetic based methods. Resolving these challenges will become more urgent as the nuclear industry is forced to address the complications of the aging nuclear infrastructure - specifically at tank storage locations on laboratory sites across the DOE complex. A powerful, new approach to inspecting and monitoring the structural integrity of large structures, such as double-shelled tanks, is being developed using ultrasonic guided waves. Acoustic waves that propagate in a plate or other structure where the wavelength is larger than the thickness of the structure are known as ultrasonic guided waves. Ultrasonic guided waves can potentially propagate distances of tens to hundreds of feet in plate-like structures, such as those that comprise the walls and bottom of a storage tank. Guided waves enable the examination of relatively large inspection volumes from the outside surface of the structure. In double-shell tanks, the technology offers promise for examining the floor of the structure or the walls by placing guided wave sensors at accessible locations in the annulus. This guided wave technology has the capability to detect and localize areas of damage or degradation. While guided wave has recently been used in the nuclear and oil and gas industries for inspecting one-dimensional piping systems, current research is developing methods to apply this technology to the two-dimensional surfaces of double-shell storage tanks. Permanently installed sensors are being developed which would remotely collect data that would be analyzed to monitor the structural condition of the tank. Initial tests have been conducted on single plate structures to study guided wave interaction with various shapes and sizes of pertinent simulated damage mechanisms, and the experimental results were compared with hybrid finite-element numerical models. Dispersion curves were calculated to study guided wave modes and their properties in carbon steel plates and to evaluate behaviors at joints between plates. The next steps in the research process include applying the transmitters and sensors to full scale mockups, developing more mature data interpretation, and then demonstrations at an actual site. (authors)
Purpose: To evaluate the usefulness of guided breathing for dose rate-regulated tracking (DRRT), a new technique to compensate for intrafraction tumor motion. Methods and Materials: DRRT uses a preprogrammed multileaf collimator sequence that tracks the tumor motion derived from four-dimensional computed tomography and the corresponding breathing signals measured before treatment. Because the multileaf collimator speed can be controlled by adjusting the dose rate, the multileaf collimator positions are adjusted in real time during treatment by dose rate regulation, thereby maintaining synchrony with the tumor motion. DRRT treatment was simulated with free, audio-guided, and audiovisual-guided breathing signals acquired from 23 lung cancer patients. The tracking error and duty cycle for each patient were determined as a function of the system time delay (range, 0-1.0 s). Results: The tracking error and duty cycle averaged for all 23 patients was 1.9 {+-} 0.8 mm and 92% {+-} 5%, 1.9 {+-} 1.0 mm and 93% {+-} 6%, and 1.8 {+-} 0.7 mm and 92% {+-} 6% for the free, audio-guided, and audiovisual-guided breathing, respectively, for a time delay of 0.35 s. The small differences in both the tracking error and the duty cycle with guided breathing were not statistically significant. Conclusion: DRRT by its nature adapts well to variations in breathing frequency, which is also the motivation for guided-breathing techniques. Because of this redundancy, guided breathing does not result in significant improvements for either the tracking error or the duty cycle when DRRT is used for real-time tumor tracking.